lib/openstudio-standards.rb in openstudio-standards-0.6.0.rc2 vs lib/openstudio-standards.rb in openstudio-standards-0.6.3
- old
+ new
@@ -22,20 +22,24 @@
require_relative 'openstudio-standards/constructions/materials/information'
require_relative 'openstudio-standards/constructions/materials/modify'
# Infiltration Module
require_relative 'openstudio-standards/infiltration/infiltration'
+ require_relative 'openstudio-standards/infiltration/nist_infiltration'
# Daylighting Module
require_relative 'openstudio-standards/daylighting/space'
# Schedules Module
require_relative 'openstudio-standards/schedules/create'
require_relative 'openstudio-standards/schedules/modify'
require_relative 'openstudio-standards/schedules/information'
require_relative 'openstudio-standards/schedules/parametric'
+ # ServiceWaterHeating Module
+ require_relative 'openstudio-standards/service_water_heating/component'
+
# Space Module
require_relative 'openstudio-standards/space/space'
# Thermal Zone Module
require_relative 'openstudio-standards/thermal_zone/thermal_zone'
@@ -224,21 +228,15 @@
require_relative "#{stds}/cbes/cbes_t24_1992/cbes_t24_1992"
require_relative "#{stds}/cbes/cbes_t24_2001/cbes_t24_2001"
require_relative "#{stds}/cbes/cbes_t24_2005/cbes_t24_2005"
require_relative "#{stds}/cbes/cbes_t24_2008/cbes_t24_2008"
- # Files with modules
- require_relative "#{stds}/Standards.Fan"
+ # Base Model Objects
require_relative "#{stds}/Standards.CoilDX"
- require_relative "#{stds}/Standards.Pump"
require_relative "#{stds}/Standards.CoolingTower"
- require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower"
- require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2013/ashrae_90_1_2013.CoolingTower"
- require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2016/ashrae_90_1_2016.CoolingTower"
- require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.CoolingTower"
- require_relative "#{stds}/ashrae_90_1/nrel_zne_ready_2017/nrel_zne_ready_2017.CoolingTower"
- require_relative "#{stds}/ashrae_90_1/ze_aedg_multifamily/ze_aedg_multifamily.CoolingTower"
+ require_relative "#{stds}/Standards.Fan"
+ require_relative "#{stds}/Standards.Pump"
require_relative "#{stds}/ashrae_90_1_prm/ashrae_90_1_prm.Fan"
# Model Objects
require_relative "#{stds}/Standards.AirLoopHVAC"
require_relative "#{stds}/Standards.AirTerminalSingleDuctParallelPIUReheat"
@@ -247,21 +245,18 @@
require_relative "#{stds}/Standards.ChillerElectricEIR"
require_relative "#{stds}/Standards.CoilCoolingDXMultiSpeed"
require_relative "#{stds}/Standards.CoilCoolingDXSingleSpeed"
require_relative "#{stds}/Standards.CoilCoolingDXTwoSpeed"
require_relative "#{stds}/Standards.CoilCoolingWaterToAirHeatPumpEquationFit"
- require_relative "#{stds}/Standards.CoilDX"
require_relative "#{stds}/Standards.CoilHeatingDXMultiSpeed"
require_relative "#{stds}/Standards.CoilHeatingDXSingleSpeed"
require_relative "#{stds}/Standards.CoilHeatingGasMultiStage"
require_relative "#{stds}/Standards.CoilHeatingGas"
require_relative "#{stds}/Standards.CoilHeatingWaterToAirHeatPumpEquationFit"
- require_relative "#{stds}/Standards.CoolingTower"
require_relative "#{stds}/Standards.CoolingTowerSingleSpeed"
require_relative "#{stds}/Standards.CoolingTowerTwoSpeed"
require_relative "#{stds}/Standards.CoolingTowerVariableSpeed"
- require_relative "#{stds}/Standards.Fan"
require_relative "#{stds}/Standards.FanConstantVolume"
require_relative "#{stds}/Standards.FanOnOff"
require_relative "#{stds}/Standards.FanVariableVolume"
require_relative "#{stds}/Standards.FanZoneExhaust"
require_relative "#{stds}/Standards.FluidCooler"
@@ -269,11 +264,10 @@
require_relative "#{stds}/Standards.HeaderedPumpsVariableSpeed"
require_relative "#{stds}/Standards.HeatExchangerSensLat"
require_relative "#{stds}/Standards.Model"
require_relative "#{stds}/Standards.PlanarSurface"
require_relative "#{stds}/Standards.PlantLoop"
- require_relative "#{stds}/Standards.Pump"
require_relative "#{stds}/Standards.PumpConstantSpeed"
require_relative "#{stds}/Standards.PumpVariableSpeed"
require_relative "#{stds}/Standards.ScheduleRuleset"
require_relative "#{stds}/Standards.Space"
require_relative "#{stds}/Standards.SpaceType"
@@ -303,9 +297,10 @@
# 90.1-2010
require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirLoopHVAC"
require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.BoilerHotWater"
require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.AirTerminalSingleDuctVAVReheat"
require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.ChillerElectricEIR"
+ require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTower"
require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTowerSingleSpeed"
require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTowerTwoSpeed"
require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.CoolingTowerVariableSpeed"
require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.FanVariableVolume"
require_relative "#{stds}/ashrae_90_1/ashrae_90_1_2010/ashrae_90_1_2010.Model"