lib/openstudio-standards.rb in openstudio-standards-0.2.14 vs lib/openstudio-standards.rb in openstudio-standards-0.2.15.pre.rc1

- old
+ new

@@ -50,10 +50,13 @@ require_relative "#{stds}/necb/NECB2015/lighting" require_relative "#{stds}/necb/NECB2015/hvac_systems" # NECB2017 Code require_relative "#{stds}/necb/NECB2017/necb_2017" require_relative "#{stds}/necb/NECB2017/hvac_systems" + # NECB2020 Code + require_relative "#{stds}/necb/NECB2020/necb_2020" + require_relative "#{stds}/necb/NECB2020/building_envelope" # BTAPPRE1980 require_relative "#{stds}/necb/BTAPPRE1980/btap_pre1980" require_relative "#{stds}/necb/BTAPPRE1980/building_envelope" require_relative "#{stds}/necb/BTAPPRE1980/hvac_systems" @@ -65,17 +68,21 @@ require_relative "#{stds}/necb/BTAP1980TO2010/btap_1980to2010" # NECB QAQC require_relative "#{stds}/necb/NECB2011/qaqc/necb_qaqc.rb" require_relative "#{stds}/necb/NECB2015/qaqc/necb_2015_qaqc.rb" + require_relative "#{stds}/necb/common/btap_data.rb" + require_relative "#{stds}/necb/common/btap_datapoint.rb" + # ECM development require_relative "#{stds}/necb/ECMS/ecms.rb" require_relative "#{stds}/necb/ECMS/erv.rb" require_relative "#{stds}/necb/ECMS/hvac_systems.rb" require_relative "#{stds}/necb/ECMS/nv.rb" require_relative "#{stds}/necb/ECMS/pv_ground.rb" + require_relative "#{stds}/necb/ECMS/loads.rb" require_relative "#{stds}/ashrae_90_1/ashrae_90_1" require_relative "#{stds}/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980" require_relative "#{stds}/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980" require_relative "#{stds}/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004" @@ -434,10 +441,12 @@ require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume" require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model" require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators" require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems" require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat" + require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump" require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed" + require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space" # DOE Ref 1980-2004 require_relative "#{proto}/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat" require_relative "#{proto}/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators" require_relative "#{proto}/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration" # DOE Ref Pre-1980