lib/openstudio-standards.rb in openstudio-standards-0.2.14 vs lib/openstudio-standards.rb in openstudio-standards-0.2.15.pre.rc1
- old
+ new
@@ -50,10 +50,13 @@
require_relative "#{stds}/necb/NECB2015/lighting"
require_relative "#{stds}/necb/NECB2015/hvac_systems"
# NECB2017 Code
require_relative "#{stds}/necb/NECB2017/necb_2017"
require_relative "#{stds}/necb/NECB2017/hvac_systems"
+ # NECB2020 Code
+ require_relative "#{stds}/necb/NECB2020/necb_2020"
+ require_relative "#{stds}/necb/NECB2020/building_envelope"
# BTAPPRE1980
require_relative "#{stds}/necb/BTAPPRE1980/btap_pre1980"
require_relative "#{stds}/necb/BTAPPRE1980/building_envelope"
require_relative "#{stds}/necb/BTAPPRE1980/hvac_systems"
@@ -65,17 +68,21 @@
require_relative "#{stds}/necb/BTAP1980TO2010/btap_1980to2010"
# NECB QAQC
require_relative "#{stds}/necb/NECB2011/qaqc/necb_qaqc.rb"
require_relative "#{stds}/necb/NECB2015/qaqc/necb_2015_qaqc.rb"
+ require_relative "#{stds}/necb/common/btap_data.rb"
+ require_relative "#{stds}/necb/common/btap_datapoint.rb"
+
# ECM development
require_relative "#{stds}/necb/ECMS/ecms.rb"
require_relative "#{stds}/necb/ECMS/erv.rb"
require_relative "#{stds}/necb/ECMS/hvac_systems.rb"
require_relative "#{stds}/necb/ECMS/nv.rb"
require_relative "#{stds}/necb/ECMS/pv_ground.rb"
+ require_relative "#{stds}/necb/ECMS/loads.rb"
require_relative "#{stds}/ashrae_90_1/ashrae_90_1"
require_relative "#{stds}/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980"
require_relative "#{stds}/ashrae_90_1/doe_ref_pre_1980/comstock_doe_ref_pre_1980/comstock_doe_ref_pre_1980"
require_relative "#{stds}/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004"
@@ -434,10 +441,12 @@
require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.FanVariableVolume"
require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model"
require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Model.elevators"
require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.hvac_systems"
require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat"
+ require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Pump"
require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.PumpVariableSpeed"
+ require_relative "#{proto}/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.Space"
# DOE Ref 1980-2004
require_relative "#{proto}/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.AirTerminalSingleDuctVAVReheat"
require_relative "#{proto}/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.Model.elevators"
require_relative "#{proto}/ashrae_90_1/doe_ref_1980_2004/doe_ref_1980_2004.refrigeration"
# DOE Ref Pre-1980