lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb in openstudio-standards-0.2.14 vs lib/openstudio-standards/standards/Standards.CoilCoolingWaterToAirHeatPumpEquationFit.rb in openstudio-standards-0.2.15.pre.rc1

- old
+ new

@@ -1,10 +1,11 @@ class Standard # @!group CoilCoolingWaterToAirHeatPumpEquationFit # Finds capacity in W # + # @param coil_cooling_water_to_air_heat_pump [OpenStudio::Model::CoilCoolingWaterToAirHeatPumpEquationFit] coil cooling object # @return [Double] capacity in W to be used for find object def coil_cooling_water_to_air_heat_pump_find_capacity(coil_cooling_water_to_air_heat_pump) capacity_w = nil if coil_cooling_water_to_air_heat_pump.ratedTotalCoolingCapacity.is_initialized capacity_w = coil_cooling_water_to_air_heat_pump.ratedTotalCoolingCapacity.get @@ -18,21 +19,36 @@ return capacity_w end # Finds lookup object in standards and return efficiency # + # @param coil_cooling_water_to_air_heat_pump [OpenStudio::Model::CoilCoolingWaterToAirHeatPumpEquationFit] coil cooling object # @param rename [Bool] if true, object will be renamed to include capacity and efficiency level # @return [Double] full load efficiency (COP) - def coil_cooling_water_to_air_heat_pump_standard_minimum_cop(coil_cooling_water_to_air_heat_pump, rename = false) + def coil_cooling_water_to_air_heat_pump_standard_minimum_cop(coil_cooling_water_to_air_heat_pump, rename = false, computer_room_air_conditioner = false) search_criteria = {} search_criteria['template'] = template + if computer_room_air_conditioner + search_criteria['cooling_type'] = 'WaterCooled' + search_criteria['heating_type'] = 'All Other' + search_criteria['subcategory'] = 'CRAC' + cooling_type = search_criteria['cooling_type'] + heating_type = search_criteria['heating_type'] + sub_category = search_criteria['subcategory'] + end capacity_w = coil_cooling_water_to_air_heat_pump_find_capacity(coil_cooling_water_to_air_heat_pump) capacity_btu_per_hr = OpenStudio.convert(capacity_w, 'W', 'Btu/hr').get capacity_kbtu_per_hr = OpenStudio.convert(capacity_w, 'W', 'kBtu/hr').get + return nil unless capacity_kbtu_per_hr > 0.0 # Look up the efficiency characteristics - coil_props = model_find_object(standards_data['water_source_heat_pumps'], search_criteria, capacity_btu_per_hr, Date.today) + if computer_room_air_conditioner + equipment_type = 'unitary_acs' + else + equipment_type = 'water_source_heat_pumps' + end + coil_props = model_find_object(standards_data[equipment_type], search_criteria, capacity_btu_per_hr, Date.today) # Check to make sure properties were found if coil_props.nil? OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingWaterToAirHeatPumpEquationFit', "For #{coil_cooling_water_to_air_heat_pump.name}, cannot find efficiency info using #{search_criteria}, cannot apply efficiency standard.") successfully_set_all_properties = false @@ -48,21 +64,46 @@ cop = eer_to_cop(min_eer, capacity_w = nil) new_comp_name = "#{coil_cooling_water_to_air_heat_pump.name} #{capacity_kbtu_per_hr.round}kBtu/hr #{min_eer}EER" OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingWaterToAirHeatPumpEquationFit', "For #{template}: #{coil_cooling_water_to_air_heat_pump.name}: Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; EER = #{min_eer}") end + # If specified as SCOP (water-cooled Computer Room Air Conditioned (CRAC)) + if computer_room_air_conditioner + crac_minimum_scop = coil_props['minimum_scop'] + unless crac_minimum_scop.nil? + # cop = scop / sensible heat ratio + # sensible heat ratio = sensible cool capacity / total cool capacity + if coil_cooling_water_to_air_heat_pump.ratedSensibleCoolingCapacity.is_initialized + crac_sensible_cool = coil_cooling_water_to_air_heat_pump.ratedSensibleCoolingCapacity.get + crac_total_cool = coil_cooling_water_to_air_heat_pump.ratedTotalCoolingCapacity.get + crac_sensible_cool_ratio = crac_sensible_cool / crac_total_cool + elsif coil_cooling_water_to_air_heat_pump.autosizedRatedSensibleCoolingCapacity.is_initialized + crac_sensible_cool = coil_cooling_water_to_air_heat_pump.autosizedRatedSensibleCoolingCapacity.get + crac_total_cool = coil_cooling_water_to_air_heat_pump.autosizedRatedTotalCoolingCapacity.get + crac_sensible_heat_ratio = crac_sensible_cool / crac_total_cool + else + OpenStudio.logFree(OpenStudio::Error, 'openstudio.standards.CoilCoolingWaterToAirHeatPumpEquationFit', 'Failed to get autosized sensible cool capacity') + end + cop = crac_minimum_scop / crac_sensible_heat_ratio + cop = cop.round(2) + OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.CoilCoolingWaterToAirHeatPumpEquationFit', "For #{coil_cooling_water_to_air_heat_pump.name}: #{cooling_type} #{heating_type} #{sub_category} Capacity = #{capacity_kbtu_per_hr.round}kBtu/hr; SCOP = #{crac_minimum_scop}") + end + end + # Rename if rename coil_cooling_water_to_air_heat_pump.setName(new_comp_name) end return cop end # Applies the standard efficiency ratings and typical performance curves to this object. # - # @return [Bool] true if successful, false if not + # @param coil_cooling_water_to_air_heat_pump [OpenStudio::Model::CoilCoolingWaterToAirHeatPumpEquationFit] coil cooling object + # @param sql_db_vars_map [Hash] hash map + # @return [Hash] hash of coil objects def coil_cooling_water_to_air_heat_pump_apply_efficiency_and_curves(coil_cooling_water_to_air_heat_pump, sql_db_vars_map) successfully_set_all_properties = true # Get the search criteria search_criteria = {} @@ -78,10 +119,10 @@ OpenStudio.logFree(OpenStudio::Warn, 'openstudio.standards.CoilCoolingWaterToAirHeatPumpEquationFit', "For #{coil_cooling_water_to_air_heat_pump.name}, cannot find efficiency info using #{search_criteria}, cannot apply efficiency standard.") successfully_set_all_properties = false return sql_db_vars_map end - # TODO: Add methods to set coefficients, and add coefficients to data spreadsheet + # @todo Add methods to set coefficients, and add coefficients to data spreadsheet # using OS defaults for now # tot_cool_cap_coeff1 = coil_props['tot_cool_cap_coeff1'] # if tot_cool_cap_coeff1 # coil_cooling_water_to_air_heat_pump.setTotalCoolingCapacityCoefficient1(tot_cool_cap_coeff1) # else