lib/openstudio-standards/btap/measures.rb in openstudio-standards-0.2.10 vs lib/openstudio-standards/btap/measures.rb in openstudio-standards-0.2.11.rc1
- old
+ new
@@ -904,16 +904,16 @@
log << "Found Const Vol Fan #{pump_const.name.get.to_s}"
#check that this is indeed connected to an plant loop.
unless pump_const.plantLoop.empty?
pump_variable = OpenStudio::Model::PumpVariableSpeed.new(model)
#pass information from constant speed fan as much as possible.
- pump_variable.setRatedFlowRate(pump_const.getRatedFlowRate.get)
- pump_variable.setRatedPumpHead(pump_const.ratedPumpHead())
+ pump_variable.setRatedFlowRate(pump_const.ratedFlowRate)
+ pump_variable.setRatedPumpHead(pump_const.ratedPumpHead)
pump_variable.setRatedPowerConsumption(pump_const.ratedPowerConsumption.to_f)
- pump_variable.setMotorEfficiency(pump_const.motorEfficiency().to_f)
- pump_variable.setPumpControlType( pump_const.pumpControlType )
- pump_variable.setFractionofMotorInefficienciestoFluidStream(pump_const.fractionofMotorInefficienciestoFluidStream().to_f)
+ pump_variable.setMotorEfficiency(pump_const.motorEfficiency.to_f)
+ pump_variable.setPumpControlType(pump_const.pumpControlType)
+ pump_variable.setFractionofMotorInefficienciestoFluidStream(pump_const.fractionofMotorInefficienciestoFluidStream.to_f)
pump_variable.autosizeRatedFlowRate if pump_const.isRatedFlowRateAutosized
pump_variable.autosizeRatedPowerConsumption if pump_const.isRatedPowerConsumptionAutosized
#get the hot water loop.
hw_loop = pump_const.plantLoop.get
@@ -930,11 +930,11 @@
#check that this is indeed connected to an plant loop.
unless pump.plantLoop.empty?
new_pump = OpenStudio::Model::PumpVariableSpeed.new(model)
#pass information from constant speed fan as much as possible.
- new_pump.setRatedFlowRate(pump.getRatedFlowRate.get)
+ new_pump.setRatedFlowRate(pump.ratedFlowRate.get)
new_pump.setRatedPumpHead(pump.ratedPumpHead())
new_pump.setRatedPowerConsumption(pump.ratedPowerConsumption.to_f)
new_pump.setMotorEfficiency(pump.motorEfficiency().to_f)
new_pump.setFractionofMotorInefficienciestoFluidStream(pump.fractionofMotorInefficienciestoFluidStream().to_f)
new_pump.setPumpControlType( pump.pumpControlType )
@@ -1069,10 +1069,10 @@
unless @shw_setpoint_sched_name.nil? or @shw_setpoint_sched.nil?
item.setSetpointTemperatureSchedule(schedule)
end
item.setHeaterFuelType(@shw_heater_fuel_type) unless @shw_heater_fuel_type.nil?
item.setHeaterThermalEfficiency(@shw_thermal_eff) unless @shw_thermal_eff.nil?
- log << item.name.get.to_s << ",#{item.setpointTemperatureSchedule},#{item.heaterFuelType},#{item.getHeaterThermalEfficiency.get}\n"
+ log << item.name.get.to_s << ",#{item.setpointTemperatureSchedule},#{item.heaterFuelType},#{item.heaterThermalEfficiency}\n"
end
return log
end
def ecm_hotwater_boilers( model )
measure_values = [