data/standards/OpenStudio_Standards_economizers.json in openstudio-standards-0.2.7 vs data/standards/OpenStudio_Standards_economizers.json in openstudio-standards-0.2.8
- old
+ new
@@ -1,1488 +1,3350 @@
{
"economizers": [
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-1A",
"data_center": false,
"capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-1A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-1B",
"data_center": false,
"capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-1B",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-2A",
"data_center": false,
"capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-2A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-3A",
"data_center": false,
"capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-3A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-3B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-3B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-3C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-3C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-4A",
"data_center": false,
"capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
- "climate_zone": "ASHRAE 169-2006-2B",
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-4A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-4B",
"data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-4B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-4C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-4C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": false,
"capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-5B",
"data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-5B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-5C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-5C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-6A",
+ "data_center": false,
"capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-6A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-6B",
"data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-6B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-7A",
+ "data_center": false,
"capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-7A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-7B",
"data_center": false,
"capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-7B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-8A",
"data_center": false,
"capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-8A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2006-8B",
"data_center": false,
"capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2004 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2004",
"climate_zone": "ASHRAE 169-2006-8B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-1A",
"data_center": false,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-1A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-1B",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-1B",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-2A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-2A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": false,
"capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2007 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-3A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-3A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
"climate_zone": "ASHRAE 169-2006-3B",
"data_center": false,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2007 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-3B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
"climate_zone": "ASHRAE 169-2006-3C",
"data_center": false,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2007 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-3C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-4A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-4A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
"climate_zone": "ASHRAE 169-2006-4B",
"data_center": false,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2007 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-4B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
"climate_zone": "ASHRAE 169-2006-4C",
"data_center": false,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2007 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-4C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
"climate_zone": "ASHRAE 169-2006-5B",
"data_center": false,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2007 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-5B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
"climate_zone": "ASHRAE 169-2006-5C",
"data_center": false,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2007 Table 6.5.1"
},
{
- "template": "DOE Ref Pre-1980",
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-5C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-6A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-6A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
"climate_zone": "ASHRAE 169-2006-6B",
"data_center": false,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2007 Table 6.5.1"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-6B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-7A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-7A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-7B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-7B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-8A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-8A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-8B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2006-8B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-1A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-1A",
"data_center": false,
"capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-1B",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-1B",
"data_center": false,
"capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-2A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-2A",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-3A",
+ "data_center": true,
"capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-3A",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-3B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-3B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-3C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-3C",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-4A",
+ "data_center": true,
"capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-4A",
"data_center": false,
- "capacity_limit": null,
- "notes": "Same as 90.1-2004"
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
- "climate_zone": "ASHRAE 169-2006-2B",
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-4B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-4B",
"data_center": false,
- "capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-4C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-4C",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
+ },
+ {
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-5A",
"data_center": false,
- "capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-5B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-5B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-5C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-5C",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
+ },
+ {
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-6A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-6A",
"data_center": false,
- "capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-6B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-6B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
+ },
+ {
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-7A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-7A",
"data_center": false,
- "capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-7B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-7B",
"data_center": false,
- "capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-8A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-8A",
"data_center": false,
- "capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2010",
"climate_zone": "ASHRAE 169-2006-8B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
+ },
+ {
+ "template": "90.1-2010",
+ "climate_zone": "ASHRAE 169-2006-8B",
"data_center": false,
- "capacity_limit": 35000.0,
- "notes": "Same as 90.1-2004"
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-1A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-1A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-1B",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-1B",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-2A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-2A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-3A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-3A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
"climate_zone": "ASHRAE 169-2006-3B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-3B",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-3C",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2013 Table 6.5.1-2"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2013",
"climate_zone": "ASHRAE 169-2006-3C",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-4A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-4A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-4B",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2013 Table 6.5.1-2"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2013",
"climate_zone": "ASHRAE 169-2006-4B",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-4C",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2013 Table 6.5.1-2"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2013",
"climate_zone": "ASHRAE 169-2006-4C",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-5B",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2013 Table 6.5.1-2"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2013",
"climate_zone": "ASHRAE 169-2006-5B",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-5C",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2013 Table 6.5.1-2"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2013",
"climate_zone": "ASHRAE 169-2006-5C",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-6A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-6A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-6B",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "90.1-2013 Table 6.5.1-2"
},
{
- "template": "DOE Ref 1980-2004",
+ "template": "90.1-2013",
"climate_zone": "ASHRAE 169-2006-6B",
"data_center": false,
- "capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
},
{
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-7A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-7A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-7B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-7B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-8A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-8A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-8B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2006-8B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-1A",
+ "climate_zone": "ASHRAE 169-2013-1A",
"data_center": false,
"capacity_limit": null,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-1B",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-1A",
+ "data_center": true,
"capacity_limit": null,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-2A",
+ "climate_zone": "ASHRAE 169-2013-1B",
"data_center": false,
"capacity_limit": null,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-3A",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-1B",
+ "data_center": true,
"capacity_limit": null,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-4A",
+ "climate_zone": "ASHRAE 169-2013-2A",
"data_center": false,
"capacity_limit": null,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-2B",
- "data_center": false,
- "capacity_limit": 35000.0,
+ "climate_zone": "ASHRAE 169-2013-2A",
+ "data_center": true,
+ "capacity_limit": null,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-5A",
+ "climate_zone": "ASHRAE 169-2013-2B",
"data_center": false,
"capacity_limit": 35000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-6A",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-2B",
+ "data_center": true,
"capacity_limit": 35000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-7A",
+ "climate_zone": "ASHRAE 169-2013-3A",
"data_center": false,
- "capacity_limit": 35000.0,
+ "capacity_limit": null,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-7B",
+ "climate_zone": "ASHRAE 169-2013-3A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-3B",
"data_center": false,
- "capacity_limit": 35000.0,
+ "capacity_limit": 65000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-8A",
+ "climate_zone": "ASHRAE 169-2013-3B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-3C",
"data_center": false,
- "capacity_limit": 35000.0,
+ "capacity_limit": 65000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-8B",
+ "climate_zone": "ASHRAE 169-2013-3C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-4A",
"data_center": false,
- "capacity_limit": 35000.0,
+ "capacity_limit": null,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-3B",
+ "climate_zone": "ASHRAE 169-2013-4A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-4B",
"data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-3C",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-4B",
+ "data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-4B",
+ "climate_zone": "ASHRAE 169-2013-4C",
"data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-4C",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-4C",
+ "data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-5B",
+ "climate_zone": "ASHRAE 169-2013-5A",
"data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-5A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-5B",
+ "data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-5C",
+ "climate_zone": "ASHRAE 169-2013-5B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-5C",
"data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
"template": "90.1-2004",
- "climate_zone": "ASHRAE 169-2006-6B",
+ "climate_zone": "ASHRAE 169-2013-5C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-6A",
"data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-6A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2004 Table 6.5.1"
},
{
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2004",
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2004 Table 6.5.1"
+ },
+ {
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-1A",
+ "climate_zone": "ASHRAE 169-2013-1A",
"data_center": false,
"capacity_limit": null,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-1B",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-1A",
+ "data_center": true,
"capacity_limit": null,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-2A",
+ "climate_zone": "ASHRAE 169-2013-1B",
"data_center": false,
"capacity_limit": null,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-3A",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-1B",
+ "data_center": true,
"capacity_limit": null,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-4A",
+ "climate_zone": "ASHRAE 169-2013-2A",
"data_center": false,
"capacity_limit": null,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-2B",
- "data_center": false,
- "capacity_limit": 35000.0,
+ "climate_zone": "ASHRAE 169-2013-2A",
+ "data_center": true,
+ "capacity_limit": null,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-5A",
+ "climate_zone": "ASHRAE 169-2013-2B",
"data_center": false,
"capacity_limit": 35000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-6A",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-2B",
+ "data_center": true,
"capacity_limit": 35000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-7A",
+ "climate_zone": "ASHRAE 169-2013-3A",
"data_center": false,
- "capacity_limit": 35000.0,
+ "capacity_limit": null,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-7B",
+ "climate_zone": "ASHRAE 169-2013-3A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-3B",
"data_center": false,
- "capacity_limit": 35000.0,
+ "capacity_limit": 65000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-8A",
+ "climate_zone": "ASHRAE 169-2013-3B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-3C",
"data_center": false,
- "capacity_limit": 35000.0,
+ "capacity_limit": 65000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-8B",
+ "climate_zone": "ASHRAE 169-2013-3C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-4A",
"data_center": false,
- "capacity_limit": 35000.0,
+ "capacity_limit": null,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-3B",
+ "climate_zone": "ASHRAE 169-2013-4A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-4B",
"data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-3C",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-4B",
+ "data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-4B",
+ "climate_zone": "ASHRAE 169-2013-4C",
"data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-4C",
- "data_center": false,
+ "climate_zone": "ASHRAE 169-2013-4C",
+ "data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-5B",
+ "climate_zone": "ASHRAE 169-2013-5A",
"data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-5A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-5B",
+ "data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-5C",
+ "climate_zone": "ASHRAE 169-2013-5B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-5C",
"data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
"template": "90.1-2007",
- "climate_zone": "ASHRAE 169-2006-6B",
+ "climate_zone": "ASHRAE 169-2013-5C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-6A",
"data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-6A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": false,
"capacity_limit": 65000.0,
"notes": "90.1-2007 Table 6.5.1"
},
{
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
+ "template": "90.1-2007",
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": true,
+ "capacity_limit": 35000.0,
+ "notes": "90.1-2007 Table 6.5.1"
+ },
+ {
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-1A",
+ "climate_zone": "ASHRAE 169-2013-1A",
"data_center": true,
"capacity_limit": null,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-1B",
- "data_center": true,
+ "climate_zone": "ASHRAE 169-2013-1A",
+ "data_center": false,
"capacity_limit": null,
- "notes": "90.1-2010 Table 6.5.1B"
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-2A",
+ "climate_zone": "ASHRAE 169-2013-1B",
"data_center": true,
"capacity_limit": null,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-3A",
- "data_center": true,
+ "climate_zone": "ASHRAE 169-2013-1B",
+ "data_center": false,
"capacity_limit": null,
- "notes": "90.1-2010 Table 6.5.1B"
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-4A",
+ "climate_zone": "ASHRAE 169-2013-2A",
"data_center": true,
"capacity_limit": null,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-2B",
- "data_center": true,
- "capacity_limit": 135000.0,
- "notes": "90.1-2010 Table 6.5.1B"
+ "climate_zone": "ASHRAE 169-2013-2A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-5A",
+ "climate_zone": "ASHRAE 169-2013-2B",
"data_center": true,
"capacity_limit": 135000.0,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-6A",
- "data_center": true,
- "capacity_limit": 135000.0,
- "notes": "90.1-2010 Table 6.5.1B"
+ "climate_zone": "ASHRAE 169-2013-2B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-7A",
+ "climate_zone": "ASHRAE 169-2013-3A",
"data_center": true,
- "capacity_limit": 135000.0,
+ "capacity_limit": null,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-7B",
- "data_center": true,
- "capacity_limit": 135000.0,
- "notes": "90.1-2010 Table 6.5.1B"
+ "climate_zone": "ASHRAE 169-2013-3A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-8A",
+ "climate_zone": "ASHRAE 169-2013-3B",
"data_center": true,
- "capacity_limit": 135000.0,
+ "capacity_limit": 65000.0,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-8B",
- "data_center": true,
- "capacity_limit": 135000.0,
- "notes": "90.1-2010 Table 6.5.1B"
+ "climate_zone": "ASHRAE 169-2013-3B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-3B",
+ "climate_zone": "ASHRAE 169-2013-3C",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-3C",
- "data_center": true,
- "capacity_limit": 65000.0,
- "notes": "90.1-2010 Table 6.5.1B"
+ "climate_zone": "ASHRAE 169-2013-3C",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-4B",
+ "climate_zone": "ASHRAE 169-2013-4A",
"data_center": true,
- "capacity_limit": 65000.0,
+ "capacity_limit": null,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-4C",
- "data_center": true,
- "capacity_limit": 65000.0,
- "notes": "90.1-2010 Table 6.5.1B"
+ "climate_zone": "ASHRAE 169-2013-4A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-5B",
+ "climate_zone": "ASHRAE 169-2013-4B",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-5C",
- "data_center": true,
- "capacity_limit": 65000.0,
- "notes": "90.1-2010 Table 6.5.1B"
+ "climate_zone": "ASHRAE 169-2013-4B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-6B",
+ "climate_zone": "ASHRAE 169-2013-4C",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-1A",
+ "climate_zone": "ASHRAE 169-2013-4C",
"data_center": false,
- "capacity_limit": null,
+ "capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-1B",
- "data_center": false,
- "capacity_limit": null,
- "notes": "90.1-2010 Table 6.5.1A"
+ "climate_zone": "ASHRAE 169-2013-5A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-2A",
+ "climate_zone": "ASHRAE 169-2013-5A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-3A",
- "data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2010 Table 6.5.1A"
+ "climate_zone": "ASHRAE 169-2013-5B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-4A",
+ "climate_zone": "ASHRAE 169-2013-5B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-2B",
- "data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2010 Table 6.5.1A"
+ "climate_zone": "ASHRAE 169-2013-5C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-5A",
+ "climate_zone": "ASHRAE 169-2013-5C",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-6A",
- "data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2010 Table 6.5.1A"
+ "climate_zone": "ASHRAE 169-2013-6A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-7A",
+ "climate_zone": "ASHRAE 169-2013-6A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-7B",
- "data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2010 Table 6.5.1A"
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-8A",
+ "climate_zone": "ASHRAE 169-2013-6B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-8B",
- "data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2010 Table 6.5.1A"
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-3B",
+ "climate_zone": "ASHRAE 169-2013-7A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-3C",
- "data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2010 Table 6.5.1A"
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-4B",
+ "climate_zone": "ASHRAE 169-2013-7B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-4C",
- "data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2010 Table 6.5.1A"
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-5B",
+ "climate_zone": "ASHRAE 169-2013-8A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-5C",
- "data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2010 Table 6.5.1A"
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2010 Table 6.5.1B"
},
{
"template": "90.1-2010",
- "climate_zone": "ASHRAE 169-2006-6B",
+ "climate_zone": "ASHRAE 169-2013-8B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2010 Table 6.5.1A"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-1A",
+ "climate_zone": "ASHRAE 169-2013-1A",
"data_center": true,
"capacity_limit": null,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-1B",
- "data_center": true,
+ "climate_zone": "ASHRAE 169-2013-1A",
+ "data_center": false,
"capacity_limit": null,
- "notes": "90.1-2013 Table 6.5.1-2"
+ "notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-2A",
+ "climate_zone": "ASHRAE 169-2013-1B",
"data_center": true,
"capacity_limit": null,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-3A",
- "data_center": true,
+ "climate_zone": "ASHRAE 169-2013-1B",
+ "data_center": false,
"capacity_limit": null,
- "notes": "90.1-2013 Table 6.5.1-2"
+ "notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-4A",
+ "climate_zone": "ASHRAE 169-2013-2A",
"data_center": true,
"capacity_limit": null,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-2B",
- "data_center": true,
- "capacity_limit": 135000.0,
- "notes": "90.1-2013 Table 6.5.1-2"
+ "climate_zone": "ASHRAE 169-2013-2A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-5A",
+ "climate_zone": "ASHRAE 169-2013-2B",
"data_center": true,
"capacity_limit": 135000.0,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-6A",
- "data_center": true,
- "capacity_limit": 135000.0,
- "notes": "90.1-2013 Table 6.5.1-2"
+ "climate_zone": "ASHRAE 169-2013-2B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-7A",
+ "climate_zone": "ASHRAE 169-2013-3A",
"data_center": true,
- "capacity_limit": 135000.0,
+ "capacity_limit": null,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-7B",
- "data_center": true,
- "capacity_limit": 135000.0,
- "notes": "90.1-2013 Table 6.5.1-2"
+ "climate_zone": "ASHRAE 169-2013-3A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-8A",
+ "climate_zone": "ASHRAE 169-2013-3B",
"data_center": true,
- "capacity_limit": 135000.0,
+ "capacity_limit": 65000.0,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-8B",
- "data_center": true,
- "capacity_limit": 135000.0,
- "notes": "90.1-2013 Table 6.5.1-2"
+ "climate_zone": "ASHRAE 169-2013-3B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-3B",
+ "climate_zone": "ASHRAE 169-2013-3C",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-3C",
+ "climate_zone": "ASHRAE 169-2013-3C",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-4A",
"data_center": true,
- "capacity_limit": 65000.0,
+ "capacity_limit": null,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-4B",
+ "climate_zone": "ASHRAE 169-2013-4A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-4B",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-4C",
+ "climate_zone": "ASHRAE 169-2013-4B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-4C",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-5B",
+ "climate_zone": "ASHRAE 169-2013-4C",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-5A",
"data_center": true,
- "capacity_limit": 65000.0,
+ "capacity_limit": 135000.0,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-5C",
+ "climate_zone": "ASHRAE 169-2013-5A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-5B",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-6B",
+ "climate_zone": "ASHRAE 169-2013-5B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "90.1-2013 Table 6.5.1-1"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-5C",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-1A",
+ "climate_zone": "ASHRAE 169-2013-5C",
"data_center": false,
- "capacity_limit": null,
+ "capacity_limit": 54000.0,
"notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-1B",
- "data_center": false,
- "capacity_limit": null,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "climate_zone": "ASHRAE 169-2013-6A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-2A",
+ "climate_zone": "ASHRAE 169-2013-6A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-3A",
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-6B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-4A",
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-7A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-2B",
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-7B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-5A",
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-8A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2013 Table 6.5.1-1"
},
{
"template": "90.1-2013",
- "climate_zone": "ASHRAE 169-2006-6A",
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "90.1-2013 Table 6.5.1-2"
+ },
+ {
+ "template": "90.1-2013",
+ "climate_zone": "ASHRAE 169-2013-8B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "90.1-2013 Table 6.5.1-1"
},
{
- "template": "90.1-2013",
+ "template": "CBES Pre-1978",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "CBES T24 1978",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "CBES T24 1992",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "CBES T24 2001",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "CBES T24 2005",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "CBES T24 2008",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DEER 1985",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 1985",
+ "climate_zone": "Any",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2003",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2003",
+ "climate_zone": "Any",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2007",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2007",
+ "climate_zone": "Any",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2011",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2011",
+ "climate_zone": "Any",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2014",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2014",
+ "climate_zone": "Any",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2015",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": 55000.0,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2015",
+ "climate_zone": "Any",
+ "data_center": true,
+ "capacity_limit": 55000.0,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2017",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": 55000.0,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER 2017",
+ "climate_zone": "Any",
+ "data_center": true,
+ "capacity_limit": 55000.0,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER Pre-1975",
+ "climate_zone": "Any",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DEER Pre-1975",
+ "climate_zone": "Any",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "From MASControl2"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-1A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-1B",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-2A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-3A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-3B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-3C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-4A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-4B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-4C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-5B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-5C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-6A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2006-6B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
"climate_zone": "ASHRAE 169-2006-7A",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref 1980-2004",
"climate_zone": "ASHRAE 169-2006-7B",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref 1980-2004",
"climate_zone": "ASHRAE 169-2006-8A",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref 1980-2004",
"climate_zone": "ASHRAE 169-2006-8B",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-1A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-1B",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-2A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-3A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
"climate_zone": "ASHRAE 169-2006-3B",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref Pre-1980",
"climate_zone": "ASHRAE 169-2006-3C",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-4A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
"climate_zone": "ASHRAE 169-2006-4B",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref Pre-1980",
"climate_zone": "ASHRAE 169-2006-4C",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
"climate_zone": "ASHRAE 169-2006-5B",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref Pre-1980",
"climate_zone": "ASHRAE 169-2006-5C",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
},
{
- "template": "90.1-2013",
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-6A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
"climate_zone": "ASHRAE 169-2006-6B",
"data_center": false,
- "capacity_limit": 54000.0,
- "notes": "90.1-2013 Table 6.5.1-1"
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
},
{
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-7A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-7B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-8A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2006-8B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
"template": "NREL ZNE Ready 2017",
"climate_zone": "ASHRAE 169-2006-1A",
"data_center": true,
"capacity_limit": null,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-1B",
- "data_center": true,
+ "climate_zone": "ASHRAE 169-2006-1A",
+ "data_center": false,
"capacity_limit": null,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-2A",
+ "climate_zone": "ASHRAE 169-2006-1B",
"data_center": true,
"capacity_limit": null,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-3A",
- "data_center": true,
+ "climate_zone": "ASHRAE 169-2006-1B",
+ "data_center": false,
"capacity_limit": null,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-4A",
+ "climate_zone": "ASHRAE 169-2006-2A",
"data_center": true,
"capacity_limit": null,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-2B",
- "data_center": true,
- "capacity_limit": 135000.0,
+ "climate_zone": "ASHRAE 169-2006-2A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-5A",
+ "climate_zone": "ASHRAE 169-2006-2B",
"data_center": true,
"capacity_limit": 135000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-6A",
- "data_center": true,
- "capacity_limit": 135000.0,
+ "climate_zone": "ASHRAE 169-2006-2B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-7A",
+ "climate_zone": "ASHRAE 169-2006-3A",
"data_center": true,
- "capacity_limit": 135000.0,
+ "capacity_limit": null,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-7B",
- "data_center": true,
- "capacity_limit": 135000.0,
+ "climate_zone": "ASHRAE 169-2006-3A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-8A",
+ "climate_zone": "ASHRAE 169-2006-3B",
"data_center": true,
- "capacity_limit": 135000.0,
+ "capacity_limit": 65000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-8B",
- "data_center": true,
- "capacity_limit": 135000.0,
+ "climate_zone": "ASHRAE 169-2006-3B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-3B",
+ "climate_zone": "ASHRAE 169-2006-3C",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
"climate_zone": "ASHRAE 169-2006-3C",
- "data_center": true,
- "capacity_limit": 65000.0,
+ "data_center": false,
+ "capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-4B",
+ "climate_zone": "ASHRAE 169-2006-4A",
"data_center": true,
- "capacity_limit": 65000.0,
+ "capacity_limit": null,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-4C",
- "data_center": true,
- "capacity_limit": 65000.0,
+ "climate_zone": "ASHRAE 169-2006-4A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-5B",
+ "climate_zone": "ASHRAE 169-2006-4B",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-5C",
- "data_center": true,
- "capacity_limit": 65000.0,
+ "climate_zone": "ASHRAE 169-2006-4B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-6B",
+ "climate_zone": "ASHRAE 169-2006-4C",
"data_center": true,
"capacity_limit": 65000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-1A",
+ "climate_zone": "ASHRAE 169-2006-4C",
"data_center": false,
- "capacity_limit": null,
+ "capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-1B",
- "data_center": false,
- "capacity_limit": null,
+ "climate_zone": "ASHRAE 169-2006-5A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-2A",
+ "climate_zone": "ASHRAE 169-2006-5A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-3A",
- "data_center": false,
- "capacity_limit": 54000.0,
+ "climate_zone": "ASHRAE 169-2006-5B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-4A",
+ "climate_zone": "ASHRAE 169-2006-5B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-2B",
- "data_center": false,
- "capacity_limit": 54000.0,
+ "climate_zone": "ASHRAE 169-2006-5C",
+ "data_center": true,
+ "capacity_limit": 65000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-5A",
+ "climate_zone": "ASHRAE 169-2006-5C",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
"climate_zone": "ASHRAE 169-2006-6A",
- "data_center": false,
- "capacity_limit": 54000.0,
+ "data_center": true,
+ "capacity_limit": 135000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-7A",
+ "climate_zone": "ASHRAE 169-2006-6A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-7B",
- "data_center": false,
- "capacity_limit": 54000.0,
+ "climate_zone": "ASHRAE 169-2006-6B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-8A",
+ "climate_zone": "ASHRAE 169-2006-6B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-8B",
- "data_center": false,
- "capacity_limit": 54000.0,
+ "climate_zone": "ASHRAE 169-2006-7A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-3B",
+ "climate_zone": "ASHRAE 169-2006-7A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-3C",
- "data_center": false,
- "capacity_limit": 54000.0,
+ "climate_zone": "ASHRAE 169-2006-7B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-4B",
+ "climate_zone": "ASHRAE 169-2006-7B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-4C",
- "data_center": false,
- "capacity_limit": 54000.0,
+ "climate_zone": "ASHRAE 169-2006-8A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-5B",
+ "climate_zone": "ASHRAE 169-2006-8A",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-5C",
- "data_center": false,
- "capacity_limit": 54000.0,
+ "climate_zone": "ASHRAE 169-2006-8B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
"notes": "Same as 90.1-2013"
},
{
"template": "NREL ZNE Ready 2017",
- "climate_zone": "ASHRAE 169-2006-6B",
+ "climate_zone": "ASHRAE 169-2006-8B",
"data_center": false,
"capacity_limit": 54000.0,
"notes": "Same as 90.1-2013"
},
{
- "template": "DEER Pre-1975",
- "climate_zone": "Any",
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-1A",
"data_center": false,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2004"
},
{
- "template": "DEER Pre-1975",
- "climate_zone": "Any",
- "data_center": true,
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-1B",
+ "data_center": false,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2004"
},
{
- "template": "DEER 1985",
- "climate_zone": "Any",
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-2A",
"data_center": false,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2004"
},
{
- "template": "DEER 1985",
- "climate_zone": "Any",
- "data_center": true,
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-2B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-3A",
+ "data_center": false,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2004"
},
{
- "template": "DEER 2003",
- "climate_zone": "Any",
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-3B",
"data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-3C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-4A",
+ "data_center": false,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2004"
},
{
- "template": "DEER 2003",
- "climate_zone": "Any",
- "data_center": true,
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-4B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-4C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-5A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-5B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-5C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-6A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref 1980-2004",
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-1A",
+ "data_center": false,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2004"
},
{
- "template": "DEER 2007",
- "climate_zone": "Any",
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-1B",
"data_center": false,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2004"
},
{
- "template": "DEER 2007",
- "climate_zone": "Any",
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-2A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-2B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-3A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-3B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-3C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-4A",
+ "data_center": false,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-4B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-4C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-5A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-5B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-5C",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-6A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": false,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "DOE Ref Pre-1980",
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": false,
+ "capacity_limit": 35000.0,
+ "notes": "Same as 90.1-2004"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-1A",
"data_center": true,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "DEER 2011",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-1A",
"data_center": false,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "DEER 2011",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-1B",
"data_center": true,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "DEER 2014",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-1B",
"data_center": false,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "DEER 2014",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-2A",
"data_center": true,
"capacity_limit": null,
- "notes": "From MASControl2"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "DEER 2015",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-2A",
"data_center": false,
- "capacity_limit": 55000.0,
- "notes": "From MASControl2"
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
},
{
- "template": "DEER 2015",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-2B",
"data_center": true,
- "capacity_limit": 55000.0,
- "notes": "From MASControl2"
+ "capacity_limit": 135000.0,
+ "notes": "Same as 90.1-2013"
},
{
- "template": "DEER 2017",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-2B",
"data_center": false,
- "capacity_limit": 55000.0,
- "notes": "From MASControl2"
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
},
{
- "template": "DEER 2017",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-3A",
"data_center": true,
- "capacity_limit": 55000.0,
- "notes": "From MASControl2"
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2013"
},
{
- "template": "CBES Pre-1978",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-3A",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-3B",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "CBES T24 1978",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-3B",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-3C",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "CBES T24 1992",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-3C",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-4A",
+ "data_center": true,
+ "capacity_limit": null,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-4A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-4B",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "CBES T24 2001",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-4B",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-4C",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "CBES T24 2005",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-4C",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-5A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-5A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-5B",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "Same as 90.1-2013"
},
{
- "template": "CBES T24 2008",
- "climate_zone": "Any",
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-5B",
"data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-5C",
+ "data_center": true,
"capacity_limit": 65000.0,
- "notes": "Same as 90.1-2004"
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-5C",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-6A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-6A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": true,
+ "capacity_limit": 65000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-6B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-7A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-7B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-8A",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": true,
+ "capacity_limit": 135000.0,
+ "notes": "Same as 90.1-2013"
+ },
+ {
+ "template": "NREL ZNE Ready 2017",
+ "climate_zone": "ASHRAE 169-2013-8B",
+ "data_center": false,
+ "capacity_limit": 54000.0,
+ "notes": "Same as 90.1-2013"
}
]
}
\ No newline at end of file