data/standards/OpenStudio_Standards_economizers.json in openstudio-standards-0.2.7 vs data/standards/OpenStudio_Standards_economizers.json in openstudio-standards-0.2.8

- old
+ new

@@ -1,1488 +1,3350 @@ { "economizers": [ { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-1A", "data_center": false, "capacity_limit": null, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-1B", "data_center": false, "capacity_limit": null, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-2A", "data_center": false, "capacity_limit": null, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-3A", "data_center": false, "capacity_limit": null, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-4A", "data_center": false, "capacity_limit": null, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", - "climate_zone": "ASHRAE 169-2006-2B", + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4B", "data_center": false, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": false, "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-5A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5B", "data_center": false, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": false, "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-6A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-6B", "data_center": false, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": false, "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-7A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-7B", "data_center": false, "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-7B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-8A", "data_center": false, "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-8A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2006-8B", "data_center": false, "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2004 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2004", "climate_zone": "ASHRAE 169-2006-8B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-1A", "data_center": false, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": false, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": false, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": false, "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2007 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": false, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", "climate_zone": "ASHRAE 169-2006-3B", "data_center": false, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2007 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", "climate_zone": "ASHRAE 169-2006-3C", "data_center": false, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2007 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": false, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", "climate_zone": "ASHRAE 169-2006-4B", "data_center": false, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2007 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", "climate_zone": "ASHRAE 169-2006-4C", "data_center": false, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2007 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", "climate_zone": "ASHRAE 169-2006-5B", "data_center": false, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2007 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", "climate_zone": "ASHRAE 169-2006-5C", "data_center": false, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2007 Table 6.5.1" }, { - "template": "DOE Ref Pre-1980", + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", "climate_zone": "ASHRAE 169-2006-6B", "data_center": false, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2007 Table 6.5.1" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-1A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-1A", "data_center": false, "capacity_limit": null, - "notes": "Same as 90.1-2004" + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-1B", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-1B", "data_center": false, "capacity_limit": null, - "notes": "Same as 90.1-2004" + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-2A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-2A", "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": true, "capacity_limit": null, - "notes": "Same as 90.1-2004" + "notes": "90.1-2010 Table 6.5.1B" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-3A", "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": true, "capacity_limit": null, - "notes": "Same as 90.1-2004" + "notes": "90.1-2010 Table 6.5.1B" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-4A", "data_center": false, - "capacity_limit": null, - "notes": "Same as 90.1-2004" + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", - "climate_zone": "ASHRAE 169-2006-2B", + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4B", "data_center": false, - "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-5A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5A", "data_center": false, - "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-6A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-6A", "data_center": false, - "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" + }, + { + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-7A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-7A", "data_center": false, - "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-7B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-7B", "data_center": false, - "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-8A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-8A", "data_center": false, - "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2010", "climate_zone": "ASHRAE 169-2006-8B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" + }, + { + "template": "90.1-2010", + "climate_zone": "ASHRAE 169-2006-8B", "data_center": false, - "capacity_limit": 35000.0, - "notes": "Same as 90.1-2004" + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": false, + "capacity_limit": null, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": false, + "capacity_limit": null, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", "climate_zone": "ASHRAE 169-2006-3B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3B", "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2013 Table 6.5.1-2" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2013", "climate_zone": "ASHRAE 169-2006-3C", "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2013 Table 6.5.1-2" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2013", "climate_zone": "ASHRAE 169-2006-4B", "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2013 Table 6.5.1-2" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2013", "climate_zone": "ASHRAE 169-2006-4C", "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2013 Table 6.5.1-2" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2013", "climate_zone": "ASHRAE 169-2006-5B", "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2013 Table 6.5.1-2" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2013", "climate_zone": "ASHRAE 169-2006-5C", "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "90.1-2013 Table 6.5.1-2" }, { - "template": "DOE Ref 1980-2004", + "template": "90.1-2013", "climate_zone": "ASHRAE 169-2006-6B", "data_center": false, - "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" }, { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-1A", + "climate_zone": "ASHRAE 169-2013-1A", "data_center": false, "capacity_limit": null, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-1B", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": true, "capacity_limit": null, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-2A", + "climate_zone": "ASHRAE 169-2013-1B", "data_center": false, "capacity_limit": null, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-3A", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": true, "capacity_limit": null, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-4A", + "climate_zone": "ASHRAE 169-2013-2A", "data_center": false, "capacity_limit": null, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-2B", - "data_center": false, - "capacity_limit": 35000.0, + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": true, + "capacity_limit": null, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-5A", + "climate_zone": "ASHRAE 169-2013-2B", "data_center": false, "capacity_limit": 35000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-6A", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": true, "capacity_limit": 35000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-7A", + "climate_zone": "ASHRAE 169-2013-3A", "data_center": false, - "capacity_limit": 35000.0, + "capacity_limit": null, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-7B", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-3B", "data_center": false, - "capacity_limit": 35000.0, + "capacity_limit": 65000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-8A", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-3C", "data_center": false, - "capacity_limit": 35000.0, + "capacity_limit": 65000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-8B", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-4A", "data_center": false, - "capacity_limit": 35000.0, + "capacity_limit": null, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-3B", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-4B", "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-3C", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-4B", + "climate_zone": "ASHRAE 169-2013-4C", "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-4C", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-5B", + "climate_zone": "ASHRAE 169-2013-5A", "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-5C", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-5C", "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2004 Table 6.5.1" }, { "template": "90.1-2004", - "climate_zone": "ASHRAE 169-2006-6B", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-6A", "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2004 Table 6.5.1" }, { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { + "template": "90.1-2004", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2004 Table 6.5.1" + }, + { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-1A", + "climate_zone": "ASHRAE 169-2013-1A", "data_center": false, "capacity_limit": null, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-1B", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": true, "capacity_limit": null, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-2A", + "climate_zone": "ASHRAE 169-2013-1B", "data_center": false, "capacity_limit": null, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-3A", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": true, "capacity_limit": null, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-4A", + "climate_zone": "ASHRAE 169-2013-2A", "data_center": false, "capacity_limit": null, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-2B", - "data_center": false, - "capacity_limit": 35000.0, + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": true, + "capacity_limit": null, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-5A", + "climate_zone": "ASHRAE 169-2013-2B", "data_center": false, "capacity_limit": 35000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-6A", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": true, "capacity_limit": 35000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-7A", + "climate_zone": "ASHRAE 169-2013-3A", "data_center": false, - "capacity_limit": 35000.0, + "capacity_limit": null, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-7B", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-3B", "data_center": false, - "capacity_limit": 35000.0, + "capacity_limit": 65000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-8A", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-3C", "data_center": false, - "capacity_limit": 35000.0, + "capacity_limit": 65000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-8B", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-4A", "data_center": false, - "capacity_limit": 35000.0, + "capacity_limit": null, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-3B", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": true, + "capacity_limit": null, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-4B", "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-3C", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-4B", + "climate_zone": "ASHRAE 169-2013-4C", "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-4C", - "data_center": false, + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-5B", + "climate_zone": "ASHRAE 169-2013-5A", "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-5C", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-5C", "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2007 Table 6.5.1" }, { "template": "90.1-2007", - "climate_zone": "ASHRAE 169-2006-6B", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-6A", "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": false, "capacity_limit": 65000.0, "notes": "90.1-2007 Table 6.5.1" }, { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { + "template": "90.1-2007", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": true, + "capacity_limit": 35000.0, + "notes": "90.1-2007 Table 6.5.1" + }, + { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-1A", + "climate_zone": "ASHRAE 169-2013-1A", "data_center": true, "capacity_limit": null, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-1B", - "data_center": true, + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": false, "capacity_limit": null, - "notes": "90.1-2010 Table 6.5.1B" + "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-2A", + "climate_zone": "ASHRAE 169-2013-1B", "data_center": true, "capacity_limit": null, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-3A", - "data_center": true, + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": false, "capacity_limit": null, - "notes": "90.1-2010 Table 6.5.1B" + "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-4A", + "climate_zone": "ASHRAE 169-2013-2A", "data_center": true, "capacity_limit": null, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-2B", - "data_center": true, - "capacity_limit": 135000.0, - "notes": "90.1-2010 Table 6.5.1B" + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-5A", + "climate_zone": "ASHRAE 169-2013-2B", "data_center": true, "capacity_limit": 135000.0, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-6A", - "data_center": true, - "capacity_limit": 135000.0, - "notes": "90.1-2010 Table 6.5.1B" + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-7A", + "climate_zone": "ASHRAE 169-2013-3A", "data_center": true, - "capacity_limit": 135000.0, + "capacity_limit": null, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-7B", - "data_center": true, - "capacity_limit": 135000.0, - "notes": "90.1-2010 Table 6.5.1B" + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-8A", + "climate_zone": "ASHRAE 169-2013-3B", "data_center": true, - "capacity_limit": 135000.0, + "capacity_limit": 65000.0, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-8B", - "data_center": true, - "capacity_limit": 135000.0, - "notes": "90.1-2010 Table 6.5.1B" + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-3B", + "climate_zone": "ASHRAE 169-2013-3C", "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-3C", - "data_center": true, - "capacity_limit": 65000.0, - "notes": "90.1-2010 Table 6.5.1B" + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-4B", + "climate_zone": "ASHRAE 169-2013-4A", "data_center": true, - "capacity_limit": 65000.0, + "capacity_limit": null, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-4C", - "data_center": true, - "capacity_limit": 65000.0, - "notes": "90.1-2010 Table 6.5.1B" + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-5B", + "climate_zone": "ASHRAE 169-2013-4B", "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-5C", - "data_center": true, - "capacity_limit": 65000.0, - "notes": "90.1-2010 Table 6.5.1B" + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-6B", + "climate_zone": "ASHRAE 169-2013-4C", "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-1A", + "climate_zone": "ASHRAE 169-2013-4C", "data_center": false, - "capacity_limit": null, + "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-1B", - "data_center": false, - "capacity_limit": null, - "notes": "90.1-2010 Table 6.5.1A" + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-2A", + "climate_zone": "ASHRAE 169-2013-5A", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-3A", - "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2010 Table 6.5.1A" + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-4A", + "climate_zone": "ASHRAE 169-2013-5B", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-2B", - "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2010 Table 6.5.1A" + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-5A", + "climate_zone": "ASHRAE 169-2013-5C", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-6A", - "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2010 Table 6.5.1A" + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-7A", + "climate_zone": "ASHRAE 169-2013-6A", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-7B", - "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2010 Table 6.5.1A" + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-8A", + "climate_zone": "ASHRAE 169-2013-6B", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-8B", - "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2010 Table 6.5.1A" + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-3B", + "climate_zone": "ASHRAE 169-2013-7A", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-3C", - "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2010 Table 6.5.1A" + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-4B", + "climate_zone": "ASHRAE 169-2013-7B", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-4C", - "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2010 Table 6.5.1A" + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-5B", + "climate_zone": "ASHRAE 169-2013-8A", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-5C", - "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2010 Table 6.5.1A" + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2010 Table 6.5.1B" }, { "template": "90.1-2010", - "climate_zone": "ASHRAE 169-2006-6B", + "climate_zone": "ASHRAE 169-2013-8B", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2010 Table 6.5.1A" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-1A", + "climate_zone": "ASHRAE 169-2013-1A", "data_center": true, "capacity_limit": null, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-1B", - "data_center": true, + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": false, "capacity_limit": null, - "notes": "90.1-2013 Table 6.5.1-2" + "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-2A", + "climate_zone": "ASHRAE 169-2013-1B", "data_center": true, "capacity_limit": null, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-3A", - "data_center": true, + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": false, "capacity_limit": null, - "notes": "90.1-2013 Table 6.5.1-2" + "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-4A", + "climate_zone": "ASHRAE 169-2013-2A", "data_center": true, "capacity_limit": null, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-2B", - "data_center": true, - "capacity_limit": 135000.0, - "notes": "90.1-2013 Table 6.5.1-2" + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-5A", + "climate_zone": "ASHRAE 169-2013-2B", "data_center": true, "capacity_limit": 135000.0, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-6A", - "data_center": true, - "capacity_limit": 135000.0, - "notes": "90.1-2013 Table 6.5.1-2" + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-7A", + "climate_zone": "ASHRAE 169-2013-3A", "data_center": true, - "capacity_limit": 135000.0, + "capacity_limit": null, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-7B", - "data_center": true, - "capacity_limit": 135000.0, - "notes": "90.1-2013 Table 6.5.1-2" + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-8A", + "climate_zone": "ASHRAE 169-2013-3B", "data_center": true, - "capacity_limit": 135000.0, + "capacity_limit": 65000.0, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-8B", - "data_center": true, - "capacity_limit": 135000.0, - "notes": "90.1-2013 Table 6.5.1-2" + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-3B", + "climate_zone": "ASHRAE 169-2013-3C", "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-3C", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4A", "data_center": true, - "capacity_limit": 65000.0, + "capacity_limit": null, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-4B", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4B", "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-4C", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-4C", "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-5B", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5A", "data_center": true, - "capacity_limit": 65000.0, + "capacity_limit": 135000.0, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-5C", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5B", "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-6B", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "90.1-2013 Table 6.5.1-1" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-5C", "data_center": true, "capacity_limit": 65000.0, "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-1A", + "climate_zone": "ASHRAE 169-2013-5C", "data_center": false, - "capacity_limit": null, + "capacity_limit": 54000.0, "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-1B", - "data_center": false, - "capacity_limit": null, - "notes": "90.1-2013 Table 6.5.1-1" + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-2A", + "climate_zone": "ASHRAE 169-2013-6A", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-3A", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-6B", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-4A", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7A", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-2B", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-7B", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-5A", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8A", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2013 Table 6.5.1-1" }, { "template": "90.1-2013", - "climate_zone": "ASHRAE 169-2006-6A", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "90.1-2013 Table 6.5.1-2" + }, + { + "template": "90.1-2013", + "climate_zone": "ASHRAE 169-2013-8B", "data_center": false, "capacity_limit": 54000.0, "notes": "90.1-2013 Table 6.5.1-1" }, { - "template": "90.1-2013", + "template": "CBES Pre-1978", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "CBES T24 1978", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "CBES T24 1992", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "CBES T24 2001", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "CBES T24 2005", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "CBES T24 2008", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DEER 1985", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 1985", + "climate_zone": "Any", + "data_center": true, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 2003", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 2003", + "climate_zone": "Any", + "data_center": true, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 2007", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 2007", + "climate_zone": "Any", + "data_center": true, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 2011", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 2011", + "climate_zone": "Any", + "data_center": true, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 2014", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 2014", + "climate_zone": "Any", + "data_center": true, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER 2015", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": 55000.0, + "notes": "From MASControl2" + }, + { + "template": "DEER 2015", + "climate_zone": "Any", + "data_center": true, + "capacity_limit": 55000.0, + "notes": "From MASControl2" + }, + { + "template": "DEER 2017", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": 55000.0, + "notes": "From MASControl2" + }, + { + "template": "DEER 2017", + "climate_zone": "Any", + "data_center": true, + "capacity_limit": 55000.0, + "notes": "From MASControl2" + }, + { + "template": "DEER Pre-1975", + "climate_zone": "Any", + "data_center": false, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DEER Pre-1975", + "climate_zone": "Any", + "data_center": true, + "capacity_limit": null, + "notes": "From MASControl2" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-3C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-4C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", "climate_zone": "ASHRAE 169-2006-7A", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref 1980-2004", "climate_zone": "ASHRAE 169-2006-7B", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref 1980-2004", "climate_zone": "ASHRAE 169-2006-8A", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref 1980-2004", "climate_zone": "ASHRAE 169-2006-8B", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", "climate_zone": "ASHRAE 169-2006-3B", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref Pre-1980", "climate_zone": "ASHRAE 169-2006-3C", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", "climate_zone": "ASHRAE 169-2006-4B", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref Pre-1980", "climate_zone": "ASHRAE 169-2006-4C", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", "climate_zone": "ASHRAE 169-2006-5B", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref Pre-1980", "climate_zone": "ASHRAE 169-2006-5C", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" }, { - "template": "90.1-2013", + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-6A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", "climate_zone": "ASHRAE 169-2006-6B", "data_center": false, - "capacity_limit": 54000.0, - "notes": "90.1-2013 Table 6.5.1-1" + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" }, { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { "template": "NREL ZNE Ready 2017", "climate_zone": "ASHRAE 169-2006-1A", "data_center": true, "capacity_limit": null, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-1B", - "data_center": true, + "climate_zone": "ASHRAE 169-2006-1A", + "data_center": false, "capacity_limit": null, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-2A", + "climate_zone": "ASHRAE 169-2006-1B", "data_center": true, "capacity_limit": null, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-3A", - "data_center": true, + "climate_zone": "ASHRAE 169-2006-1B", + "data_center": false, "capacity_limit": null, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-4A", + "climate_zone": "ASHRAE 169-2006-2A", "data_center": true, "capacity_limit": null, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-2B", - "data_center": true, - "capacity_limit": 135000.0, + "climate_zone": "ASHRAE 169-2006-2A", + "data_center": false, + "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-5A", + "climate_zone": "ASHRAE 169-2006-2B", "data_center": true, "capacity_limit": 135000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-6A", - "data_center": true, - "capacity_limit": 135000.0, + "climate_zone": "ASHRAE 169-2006-2B", + "data_center": false, + "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-7A", + "climate_zone": "ASHRAE 169-2006-3A", "data_center": true, - "capacity_limit": 135000.0, + "capacity_limit": null, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-7B", - "data_center": true, - "capacity_limit": 135000.0, + "climate_zone": "ASHRAE 169-2006-3A", + "data_center": false, + "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-8A", + "climate_zone": "ASHRAE 169-2006-3B", "data_center": true, - "capacity_limit": 135000.0, + "capacity_limit": 65000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-8B", - "data_center": true, - "capacity_limit": 135000.0, + "climate_zone": "ASHRAE 169-2006-3B", + "data_center": false, + "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-3B", + "climate_zone": "ASHRAE 169-2006-3C", "data_center": true, "capacity_limit": 65000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", "climate_zone": "ASHRAE 169-2006-3C", - "data_center": true, - "capacity_limit": 65000.0, + "data_center": false, + "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-4B", + "climate_zone": "ASHRAE 169-2006-4A", "data_center": true, - "capacity_limit": 65000.0, + "capacity_limit": null, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-4C", - "data_center": true, - "capacity_limit": 65000.0, + "climate_zone": "ASHRAE 169-2006-4A", + "data_center": false, + "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-5B", + "climate_zone": "ASHRAE 169-2006-4B", "data_center": true, "capacity_limit": 65000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-5C", - "data_center": true, - "capacity_limit": 65000.0, + "climate_zone": "ASHRAE 169-2006-4B", + "data_center": false, + "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-6B", + "climate_zone": "ASHRAE 169-2006-4C", "data_center": true, "capacity_limit": 65000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-1A", + "climate_zone": "ASHRAE 169-2006-4C", "data_center": false, - "capacity_limit": null, + "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-1B", - "data_center": false, - "capacity_limit": null, + "climate_zone": "ASHRAE 169-2006-5A", + "data_center": true, + "capacity_limit": 135000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-2A", + "climate_zone": "ASHRAE 169-2006-5A", "data_center": false, "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-3A", - "data_center": false, - "capacity_limit": 54000.0, + "climate_zone": "ASHRAE 169-2006-5B", + "data_center": true, + "capacity_limit": 65000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-4A", + "climate_zone": "ASHRAE 169-2006-5B", "data_center": false, "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-2B", - "data_center": false, - "capacity_limit": 54000.0, + "climate_zone": "ASHRAE 169-2006-5C", + "data_center": true, + "capacity_limit": 65000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-5A", + "climate_zone": "ASHRAE 169-2006-5C", "data_center": false, "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", "climate_zone": "ASHRAE 169-2006-6A", - "data_center": false, - "capacity_limit": 54000.0, + "data_center": true, + "capacity_limit": 135000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-7A", + "climate_zone": "ASHRAE 169-2006-6A", "data_center": false, "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-7B", - "data_center": false, - "capacity_limit": 54000.0, + "climate_zone": "ASHRAE 169-2006-6B", + "data_center": true, + "capacity_limit": 65000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-8A", + "climate_zone": "ASHRAE 169-2006-6B", "data_center": false, "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-8B", - "data_center": false, - "capacity_limit": 54000.0, + "climate_zone": "ASHRAE 169-2006-7A", + "data_center": true, + "capacity_limit": 135000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-3B", + "climate_zone": "ASHRAE 169-2006-7A", "data_center": false, "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-3C", - "data_center": false, - "capacity_limit": 54000.0, + "climate_zone": "ASHRAE 169-2006-7B", + "data_center": true, + "capacity_limit": 135000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-4B", + "climate_zone": "ASHRAE 169-2006-7B", "data_center": false, "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-4C", - "data_center": false, - "capacity_limit": 54000.0, + "climate_zone": "ASHRAE 169-2006-8A", + "data_center": true, + "capacity_limit": 135000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-5B", + "climate_zone": "ASHRAE 169-2006-8A", "data_center": false, "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-5C", - "data_center": false, - "capacity_limit": 54000.0, + "climate_zone": "ASHRAE 169-2006-8B", + "data_center": true, + "capacity_limit": 135000.0, "notes": "Same as 90.1-2013" }, { "template": "NREL ZNE Ready 2017", - "climate_zone": "ASHRAE 169-2006-6B", + "climate_zone": "ASHRAE 169-2006-8B", "data_center": false, "capacity_limit": 54000.0, "notes": "Same as 90.1-2013" }, { - "template": "DEER Pre-1975", - "climate_zone": "Any", + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-1A", "data_center": false, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2004" }, { - "template": "DEER Pre-1975", - "climate_zone": "Any", - "data_center": true, + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-1B", + "data_center": false, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2004" }, { - "template": "DEER 1985", - "climate_zone": "Any", + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-2A", "data_center": false, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2004" }, { - "template": "DEER 1985", - "climate_zone": "Any", - "data_center": true, + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": false, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2004" }, { - "template": "DEER 2003", - "climate_zone": "Any", + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-3B", "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": false, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2004" }, { - "template": "DEER 2003", - "climate_zone": "Any", - "data_center": true, + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref 1980-2004", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-1A", + "data_center": false, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2004" }, { - "template": "DEER 2007", - "climate_zone": "Any", + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-1B", "data_center": false, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2004" }, { - "template": "DEER 2007", - "climate_zone": "Any", + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-2A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-2B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-3A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": false, + "capacity_limit": null, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": false, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "DOE Ref Pre-1980", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": false, + "capacity_limit": 35000.0, + "notes": "Same as 90.1-2004" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-1A", "data_center": true, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2013" }, { - "template": "DEER 2011", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-1A", "data_center": false, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2013" }, { - "template": "DEER 2011", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-1B", "data_center": true, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2013" }, { - "template": "DEER 2014", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-1B", "data_center": false, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2013" }, { - "template": "DEER 2014", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-2A", "data_center": true, "capacity_limit": null, - "notes": "From MASControl2" + "notes": "Same as 90.1-2013" }, { - "template": "DEER 2015", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-2A", "data_center": false, - "capacity_limit": 55000.0, - "notes": "From MASControl2" + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" }, { - "template": "DEER 2015", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-2B", "data_center": true, - "capacity_limit": 55000.0, - "notes": "From MASControl2" + "capacity_limit": 135000.0, + "notes": "Same as 90.1-2013" }, { - "template": "DEER 2017", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-2B", "data_center": false, - "capacity_limit": 55000.0, - "notes": "From MASControl2" + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" }, { - "template": "DEER 2017", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-3A", "data_center": true, - "capacity_limit": 55000.0, - "notes": "From MASControl2" + "capacity_limit": null, + "notes": "Same as 90.1-2013" }, { - "template": "CBES Pre-1978", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-3A", "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-3B", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "Same as 90.1-2013" }, { - "template": "CBES T24 1978", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-3B", "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-3C", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "Same as 90.1-2013" }, { - "template": "CBES T24 1992", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-3C", "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": true, + "capacity_limit": null, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-4A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-4B", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "Same as 90.1-2013" }, { - "template": "CBES T24 2001", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-4B", "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-4C", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "Same as 90.1-2013" }, { - "template": "CBES T24 2005", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-4C", "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-5A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-5B", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "Same as 90.1-2013" }, { - "template": "CBES T24 2008", - "climate_zone": "Any", + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-5B", "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": true, "capacity_limit": 65000.0, - "notes": "Same as 90.1-2004" + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-5C", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-6A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": true, + "capacity_limit": 65000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-6B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-7A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-7B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-8A", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": true, + "capacity_limit": 135000.0, + "notes": "Same as 90.1-2013" + }, + { + "template": "NREL ZNE Ready 2017", + "climate_zone": "ASHRAE 169-2013-8B", + "data_center": false, + "capacity_limit": 54000.0, + "notes": "Same as 90.1-2013" } ] } \ No newline at end of file