data/standards/OpenStudio_Standards_curves.json in openstudio-standards-0.2.2 vs data/standards/OpenStudio_Standards_curves.json in openstudio-standards-0.2.3

- old
+ new

@@ -6374,10 +6374,35 @@ "minimum_dependent_variable_output": null, "maximum_dependent_variable_output": null, "notes": "From Prototype Buildings" }, { + "name": "HPACHeatEIRFFF", + "category": "DX Heating Coil", + "form": "Quadratic", + "dependent_variable": "EIRRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 1.3824, + "coeff_2": -0.4336, + "coeff_3": 0.0512, + "coeff_4": null, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": null, + "maximum_dependent_variable_output": null, + "notes": "From Prototype Buildings" + }, + { "name": "HPACHeatEIRFT", "category": "DX Heating Coil", "form": "Cubic", "dependent_variable": "EIRRatio", "independent_variable_1": "Toadb", @@ -7449,10 +7474,185 @@ "minimum_dependent_variable_output": null, "maximum_dependent_variable_output": null, "notes": "From Reference Buildings" }, { + "name": "Multi Zone VAV with Airfoil or Backward Incline riding the curve", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.1631, + "coeff_2": 1.5901, + "coeff_3": -0.8817, + "coeff_4": 0.1281, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.7, + "maximum_dependent_variable_output": null, + "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with Airfoil or Backward Incline with inlet vanes", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.9977, + "coeff_2": -0.659, + "coeff_3": 0.9547, + "coeff_4": -0.2936, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.5, + "maximum_dependent_variable_output": null, + "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with Forward Curved fans riding the curve", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.1224, + "coeff_2": 0.612, + "coeff_3": 0.5983, + "coeff_4": -0.3334, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.3, + "maximum_dependent_variable_output": null, + "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with Forward Curved with inlet vanes", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.3038, + "coeff_2": -0.7608, + "coeff_3": 2.2729, + "coeff_4": -0.8169, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.3, + "maximum_dependent_variable_output": null, + "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with VSD and fixed SP setpoint", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.0013, + "coeff_2": 0.147, + "coeff_3": 0.9506, + "coeff_4": -0.0998, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.2, + "maximum_dependent_variable_output": null, + "notes": "Appendix G baseline from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi Zone VAV with vane-axial with variable pitch blades", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.1639, + "coeff_2": -0.4016, + "coeff_3": 1.9909, + "coeff_4": -0.7541, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.2, + "maximum_dependent_variable_output": null, + "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { + "name": "Multi zone VAV with static pressure reset", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.040759894, + "coeff_2": 0.08804497, + "coeff_3": -0.07292612, + "coeff_4": 0.943739823, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": null, + "notes": "OpenStudio default, baseline for System Types 5-8 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { "name": "New_Low_Temp_Comp_Cap_Curve", "category": null, "form": "BiCubic", "dependent_variable": null, "independent_variable_1": null, @@ -7549,10 +7749,35 @@ "minimum_dependent_variable_output": null, "maximum_dependent_variable_output": null, "notes": null }, { + "name": "No SP Reset VSD Fan", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.070428852, + "coeff_2": 0.385330201, + "coeff_3": -0.460864118, + "coeff_4": 1.00920344, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": null, + "notes": "From California Energy Commision, \"Advanced Variable Air Volume System Design Guide,\" October 2004" + }, + { "name": "Old_Low_Temp_Comp_Cap_Curve", "category": null, "form": "BiCubic", "dependent_variable": null, "independent_variable_1": null, @@ -12024,10 +12249,35 @@ "minimum_dependent_variable_output": null, "maximum_dependent_variable_output": null, "notes": "From Reference Buildings" }, { + "name": "Single zone VAV fan", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.027827882, + "coeff_2": 0.026583195, + "coeff_3": -0.0870687, + "coeff_4": 1.03091975, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": null, + "notes": "Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method" + }, + { "name": "Small-CHW-Bypass-fAirflow", "category": "CHWCoils", "form": "Quadratic", "dependent_variable": "QRatio", "independent_variable_1": "Airflow", @@ -15297,9 +15547,34 @@ "minimum_independent_variable_2": null, "maximum_independent_variable_2": null, "minimum_dependent_variable_output": null, "maximum_dependent_variable_output": null, "notes": "From .dat files included with MASControl2" + }, + { + "name": "Typical VSD Fan", + "category": "FanEIR-FPLR", + "form": "Cubic", + "dependent_variable": "PwrRatio", + "independent_variable_1": "FlowRatio", + "independent_variable_2": null, + "coeff_1": 0.047182815, + "coeff_2": 0.130541742, + "coeff_3": -0.117286942, + "coeff_4": 0.940313747, + "coeff_5": null, + "coeff_6": null, + "coeff_7": null, + "coeff_8": null, + "coeff_9": null, + "coeff_10": null, + "minimum_independent_variable_1": 0.0, + "maximum_independent_variable_1": 1.0, + "minimum_independent_variable_2": null, + "maximum_independent_variable_2": null, + "minimum_dependent_variable_output": 0.1, + "maximum_dependent_variable_output": null, + "notes": "From California Energy Commision, \"Advanced Variable Air Volume System Design Guide,\" October 2003" }, { "name": "TypicalCyclingAC-EIR-fPLR", "category": "CyclingAC", "form": "Cubic", \ No newline at end of file