data/standards/OpenStudio_Standards_curves.json in openstudio-standards-0.2.2 vs data/standards/OpenStudio_Standards_curves.json in openstudio-standards-0.2.3
- old
+ new
@@ -6374,10 +6374,35 @@
"minimum_dependent_variable_output": null,
"maximum_dependent_variable_output": null,
"notes": "From Prototype Buildings"
},
{
+ "name": "HPACHeatEIRFFF",
+ "category": "DX Heating Coil",
+ "form": "Quadratic",
+ "dependent_variable": "EIRRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 1.3824,
+ "coeff_2": -0.4336,
+ "coeff_3": 0.0512,
+ "coeff_4": null,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": null,
+ "maximum_dependent_variable_output": null,
+ "notes": "From Prototype Buildings"
+ },
+ {
"name": "HPACHeatEIRFT",
"category": "DX Heating Coil",
"form": "Cubic",
"dependent_variable": "EIRRatio",
"independent_variable_1": "Toadb",
@@ -7449,10 +7474,185 @@
"minimum_dependent_variable_output": null,
"maximum_dependent_variable_output": null,
"notes": "From Reference Buildings"
},
{
+ "name": "Multi Zone VAV with Airfoil or Backward Incline riding the curve",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.1631,
+ "coeff_2": 1.5901,
+ "coeff_3": -0.8817,
+ "coeff_4": 0.1281,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.7,
+ "maximum_dependent_variable_output": null,
+ "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
+ },
+ {
+ "name": "Multi Zone VAV with Airfoil or Backward Incline with inlet vanes",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.9977,
+ "coeff_2": -0.659,
+ "coeff_3": 0.9547,
+ "coeff_4": -0.2936,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.5,
+ "maximum_dependent_variable_output": null,
+ "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
+ },
+ {
+ "name": "Multi Zone VAV with Forward Curved fans riding the curve",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.1224,
+ "coeff_2": 0.612,
+ "coeff_3": 0.5983,
+ "coeff_4": -0.3334,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.3,
+ "maximum_dependent_variable_output": null,
+ "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
+ },
+ {
+ "name": "Multi Zone VAV with Forward Curved with inlet vanes",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.3038,
+ "coeff_2": -0.7608,
+ "coeff_3": 2.2729,
+ "coeff_4": -0.8169,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.3,
+ "maximum_dependent_variable_output": null,
+ "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
+ },
+ {
+ "name": "Multi Zone VAV with VSD and fixed SP setpoint",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.0013,
+ "coeff_2": 0.147,
+ "coeff_3": 0.9506,
+ "coeff_4": -0.0998,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.2,
+ "maximum_dependent_variable_output": null,
+ "notes": "Appendix G baseline from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
+ },
+ {
+ "name": "Multi Zone VAV with vane-axial with variable pitch blades",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.1639,
+ "coeff_2": -0.4016,
+ "coeff_3": 1.9909,
+ "coeff_4": -0.7541,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.2,
+ "maximum_dependent_variable_output": null,
+ "notes": "From ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
+ },
+ {
+ "name": "Multi zone VAV with static pressure reset",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.040759894,
+ "coeff_2": 0.08804497,
+ "coeff_3": -0.07292612,
+ "coeff_4": 0.943739823,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.1,
+ "maximum_dependent_variable_output": null,
+ "notes": "OpenStudio default, baseline for System Types 5-8 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
+ },
+ {
"name": "New_Low_Temp_Comp_Cap_Curve",
"category": null,
"form": "BiCubic",
"dependent_variable": null,
"independent_variable_1": null,
@@ -7549,10 +7749,35 @@
"minimum_dependent_variable_output": null,
"maximum_dependent_variable_output": null,
"notes": null
},
{
+ "name": "No SP Reset VSD Fan",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.070428852,
+ "coeff_2": 0.385330201,
+ "coeff_3": -0.460864118,
+ "coeff_4": 1.00920344,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.1,
+ "maximum_dependent_variable_output": null,
+ "notes": "From California Energy Commision, \"Advanced Variable Air Volume System Design Guide,\" October 2004"
+ },
+ {
"name": "Old_Low_Temp_Comp_Cap_Curve",
"category": null,
"form": "BiCubic",
"dependent_variable": null,
"independent_variable_1": null,
@@ -12024,10 +12249,35 @@
"minimum_dependent_variable_output": null,
"maximum_dependent_variable_output": null,
"notes": "From Reference Buildings"
},
{
+ "name": "Single zone VAV fan",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.027827882,
+ "coeff_2": 0.026583195,
+ "coeff_3": -0.0870687,
+ "coeff_4": 1.03091975,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.1,
+ "maximum_dependent_variable_output": null,
+ "notes": "Baseline for System Type 11 from ANSI/ASHRAE/IES Standard 90.1-2016 - Energy Standard for Buildings Except Low-Rise Residential Performance Rating Method"
+ },
+ {
"name": "Small-CHW-Bypass-fAirflow",
"category": "CHWCoils",
"form": "Quadratic",
"dependent_variable": "QRatio",
"independent_variable_1": "Airflow",
@@ -15297,9 +15547,34 @@
"minimum_independent_variable_2": null,
"maximum_independent_variable_2": null,
"minimum_dependent_variable_output": null,
"maximum_dependent_variable_output": null,
"notes": "From .dat files included with MASControl2"
+ },
+ {
+ "name": "Typical VSD Fan",
+ "category": "FanEIR-FPLR",
+ "form": "Cubic",
+ "dependent_variable": "PwrRatio",
+ "independent_variable_1": "FlowRatio",
+ "independent_variable_2": null,
+ "coeff_1": 0.047182815,
+ "coeff_2": 0.130541742,
+ "coeff_3": -0.117286942,
+ "coeff_4": 0.940313747,
+ "coeff_5": null,
+ "coeff_6": null,
+ "coeff_7": null,
+ "coeff_8": null,
+ "coeff_9": null,
+ "coeff_10": null,
+ "minimum_independent_variable_1": 0.0,
+ "maximum_independent_variable_1": 1.0,
+ "minimum_independent_variable_2": null,
+ "maximum_independent_variable_2": null,
+ "minimum_dependent_variable_output": 0.1,
+ "maximum_dependent_variable_output": null,
+ "notes": "From California Energy Commision, \"Advanced Variable Air Volume System Design Guide,\" October 2003"
},
{
"name": "TypicalCyclingAC-EIR-fPLR",
"category": "CyclingAC",
"form": "Cubic",
\ No newline at end of file