lib/measures/CoilHeatingElectricPercentChange/measure.rb in openstudio-calibration-0.9.0 vs lib/measures/CoilHeatingElectricPercentChange/measure.rb in openstudio-calibration-0.10.0
- old
+ new
@@ -50,10 +50,11 @@
loop_args_hash.sort.map do |_key, value|
show_loop = false
components = value.supplyComponents
components.each do |component|
next if component.to_CoilHeatingElectric.empty?
+
show_loop = true
loop_handles << component.handle.to_s
loop_display_names << component.name.to_s
end
@@ -154,17 +155,15 @@
altered_coilefficiency = []
# loop through coils
coils.each do |coil|
altered_coil = false
# coil_capacity_perc_change
- if coil_capacity_perc_change != 0.0
- if coil.nominalCapacity.is_initialized
- runner.registerInfo("Applying nominalCapacity #{coil_capacity_perc_change} Percent Change to #{coil.name.get}.")
- coil.setNominalCapacity(coil.nominalCapacity.get + coil.nominalCapacity.get * coil_capacity_perc_change * 0.01)
- altered_capacity << coil.handle.to_s
- altered_coil = true
- end
+ if coil_capacity_perc_change != 0.0 && coil.nominalCapacity.is_initialized
+ runner.registerInfo("Applying nominalCapacity #{coil_capacity_perc_change} Percent Change to #{coil.name.get}.")
+ coil.setNominalCapacity(coil.nominalCapacity.get + coil.nominalCapacity.get * coil_capacity_perc_change * 0.01)
+ altered_capacity << coil.handle.to_s
+ altered_coil = true
end
# modify coil_efficiency_perc_change
if coil_efficiency_perc_change != 0.0
runner.registerInfo("Applying efficiency #{coil_efficiency_perc_change} Percent Change to #{coil.name.get}.")
@@ -177,13 +176,14 @@
altered_coilefficiency << coil.handle.to_s
altered_coil = true
end
next unless altered_coil
+
altered_coils << coil.handle.to_s
change_name(coil, coil_efficiency_perc_change, coil_capacity_perc_change)
runner.registerInfo("coil name changed to: #{coil.name.get}")
- end # end coil loop
+ end
# na if nothing in model to look at
if altered_coils.empty?
runner.registerAsNotApplicable('No Coils were altered in the model')