Sha256: ff67df2965bdadb40cf94f141f41876a08f684e7b248a6272db23540c5e4a778

Contents?: true

Size: 1.73 KB

Versions: 4

Compression:

Stored size: 1.73 KB

Contents

{
  "boilers": [
    {
      "template": "DOE Ref Pre-1980",
      "fluid_type": "Hot Water",
      "fuel_type": "NaturalGas",
      "draft_type": null,
      "minimum_capacity": 0.0,
      "maximum_capacity": 299999.99,
      "start_date": "1919-09-09T00:00:00+00:00",
      "end_date": "2999-09-09T00:00:00+00:00",
      "minimum_annual_fuel_utilization_efficiency": null,
      "minimum_thermal_efficiency": 0.73,
      "minimum_combustion_efficiency": null,
      "standby_mode_power": null,
      "off_mode_power": null,
      "notes": "From DOE Reference Buildings"
    },
    {
      "template": "DOE Ref Pre-1980",
      "fluid_type": "Hot Water",
      "fuel_type": "NaturalGas",
      "draft_type": null,
      "minimum_capacity": 300000.0,
      "maximum_capacity": 2500000.0,
      "start_date": "1919-09-09T00:00:00+00:00",
      "end_date": "2999-09-09T00:00:00+00:00",
      "minimum_annual_fuel_utilization_efficiency": null,
      "minimum_thermal_efficiency": 0.74,
      "minimum_combustion_efficiency": null,
      "standby_mode_power": null,
      "off_mode_power": null,
      "notes": "From DOE Reference Buildings"
    },
    {
      "template": "DOE Ref Pre-1980",
      "fluid_type": "Hot Water",
      "fuel_type": "NaturalGas",
      "draft_type": null,
      "minimum_capacity": 2500000.01,
      "maximum_capacity": 9999999999.0,
      "start_date": "1919-09-09T00:00:00+00:00",
      "end_date": "2999-09-09T00:00:00+00:00",
      "minimum_annual_fuel_utilization_efficiency": null,
      "minimum_thermal_efficiency": 0.76,
      "minimum_combustion_efficiency": null,
      "standby_mode_power": null,
      "off_mode_power": null,
      "notes": "From DOE Reference Buildings"
    }
  ]
}

Version data entries

4 entries across 4 versions & 1 rubygems

Version Path
openstudio-standards-0.7.1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.boilers.json
openstudio-standards-0.7.0 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.boilers.json
openstudio-standards-0.7.0.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/data/doe_ref_pre_1980.boilers.json