© Department of Communities and Local Government. © Crown copyright, 2007. The Home Condition Report logo and associated wording is a registered trade mark - any unlicensed use is not permitted. Copyright in the typographical arrangement of this document rests with the Crown. This publication, excluding logos, may be reproduced free of charge in any format or medium for research, private study, for internal circulation within an organisation or by registered scheme users. This is subject to it being reproduced accurately and not used in a misleading context.
N/A
Very Poor
Poor
Average
Good
Very Good
Lower cost - this is for backwards compatibility only and should not be used
Higher cost - this is for backwards compatibility only and should not be used
Further measure - this is for backwards compatibility only and should not be used
Deselected. This is for backwards compatibility only and should not be used.
Normal measure
Alternative measure
1. Wall type does not correspond to options available in RdSAP
2. Room heater specified for water heating instead of a range cooker
3. Space heating from individual system and water heating from community system
4. Dwelling has a swimming pool
5. Dwelling has micro-CHP not found in database
6. Storage heater or dual immersion, and single electric meter
7. Heating controlled by TRVs only
8. PVs or wind turbine present on the property (England, Wales or Scotland)
9. Two main heating systems and heating system upgrade is recommended
10. Dual electricity meter selected but there is also an electricity meter for standard tariff
11. Single electricity meter selected but there is also an electricity meter for an off-peak tariff
12. Dwelling is using a biomass fuel that is not in the RdSAP fuel options
13. Park Home
14. Dwelling has a special energy saving feature
Insulate hot water cylinder with 80 mm jacket
Increase hot water cylinder insulation
Add additional 80 mm jacket to hot water cylinder
Hot water cylinder thermostat
Increase loft insulation to 270 mm
Cavity wall insulation
Internal or external wall insulation
Replace single glazed windows with low-E double glazing
Secondary glazing to single glazed windows
Draught proofing
Heating controls (programmer, room thermostat and TRVs)
Heating controls (room thermostat and TRVs)
Heating controls (thermostatic radiator valves)
Heating controls (room thermostat)
Heating controls (programmer and TRVs)
Heating controls (time and temperature zone control)
Heating controls (programmer and room thermostat)
Heating controls (room thermostat)
Solar water heating
Replace boiler with new condensing boiler
Replace boiler with new condensing boiler
Replace boiler with biomass boiler
Wood pellet stove with boiler and radiators
Fan assisted storage heaters and dual immersion cylinder
Fan assisted storage heaters
Replacement warm air unit
Change heating to gas condensing boiler
Condensing oil boiler with radiators
Change heating to gas condensing boiler
Fan assisted storage heaters and dual immersion cylinder
Fan-assisted storage heaters
Change heating to gas condensing boiler
Solar photovoltaic panels, 2.5 kWp
Low energy lighting for all fixed outlets
Replace heating unit with condensing unit
Condensing boiler (separate from the range cooker)
Condensing boiler (separate from the range cooker)
Wood pellet stove with boiler and radiators
Change room heaters to condensing boiler
Change room heaters to condensing boiler
Replace heating unit with mains gas condensing unit
Condensing oil boiler with radiators
Wind turbine
Flat roof or sloping ceiling insulation
Room-in-roof insulation
Floor insulation
High performance external doors
Heat recovery system for mixer showers
Flue gas heat recovery device in conjunction with boiler
Air or ground source heat pump
Air or ground source heat pump with underfloor heating
Micro CHP
Biomass boiler (Exempted Appliance if in Smoke Control Area)
External insulation with cavity wall insulation
Replacement glazing units
Suspended floor insulation
Solid floor insulation
High heat retention storage heaters and dual immersion cylinder
High heat retention storage heaters
High heat retention storage heaters and dual immersion cylinder
High heat retention storage heaters
Party wall insulation
1. Not eligible for Green Deal
2. Eligible with additional finance
3. Eligible without additional finance
Not assessed. Use for alternative measures
Not recorded
The Report Reference Number is a 20-digit unique identifier assigned to each Home Condition Report. It is formatted as five blocks of four digits i.e. 9999-9999-9999-9999-9999 and generayted by an algorithm described in Appendix A "Report ID Generation" of Section 18 "Transformation Rules" of the Technical Standards.
Code which indicates the country within the UK, taken from BS 6879.
England and Wales
Scotland
Northern Ireland
for backwards compatibility only – do not use
Code which indicates the region within the UK.
Borders
East Anglia
East Pennines
East Scotland
Highland
Midlands
North East England
North East Scotland
North West England / South West Scotland
Northern Ireland
Orkney
Severn Valley
Shetland
South East England
South West England
Southern England
Thames Valley
Wales
West Pennines
West Scotland
Western Isles
Jersey
Guernsey
Isle of Man
for backwards compatibility only – do not use
marketed sale
non marketed sale
rental (social) - this is for backwards compatibility only and should not be used
rental (private) - this is for backwards compatibility only and should not be used
none of the above
new dwelling
not recorded - this is for backwards compatibility only and should not be used
rental
assessment for green deal
following green deal
FiT application
RHI application
ECO assessment
Stock condition survey
Code indicating any potential conflicts of interest or commercial relationships with other parties.
No related party
Relative of homeowner or of occupier of the property
Residing at the property
Financial interest in the property
Owner or Director of the organisation dealing with the property transaction
Employed by the professional dealing with the property transaction
Relative of the professional dealing with the property transaction
owner-occupied
rented (social)
rented (private)
unknown
RdSAP Energy Performance Certificate
Full SAP Energy Performance Certificate
Interim RdSAP Energy Performance Certificate (to be superseded by SAP EPC)
Cancelled
entered on the register
under appeal
removed
rejected
under investigation