{ "analysis": { "display_name": "LHS Discrete and Continuous Variables", "name": "lhs_discrete_and_continuous_variables", "output_variables": [ { "units": "MJ/m2", "objective_function": true, "objective_function_index": 0, "objective_function_target": null, "objective_function_group": 1, "scaling_factor": null, "display_name": "Total Site Energy Intensity", "display_name_short": "Site EUI", "metadata_id": "total_site_energy_intensity", "name": "standard_report_legacy.total_energy", "visualize": true, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": true, "objective_function_index": 1, "objective_function_target": null, "objective_function_group": 2, "scaling_factor": null, "display_name": "Total Source Energy Intensity", "display_name_short": "Source EUI", "metadata_id": "total_source_energy_intensity", "name": "standard_report_legacy.total_source_energy", "visualize": true, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 2, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Total Natural Gas Intensity", "display_name_short": "NG EUI", "metadata_id": "total_natural_gas_intensity", "name": "standard_report_legacy.total_natural_gas", "visualize": true, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 3, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Total Electricity Intensity", "display_name_short": "Elec EUI", "metadata_id": "total_electricity_intensity", "name": "standard_report_legacy.total_electricity", "visualize": true, "export": true, "variable_type": "double" }, { "units": "hrs", "objective_function": false, "objective_function_index": 4, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Unmet Cooling Hours", "display_name_short": "Unmet Cooling Hours", "metadata_id": null, "name": "standard_reports.time_setpoint_not_met_during_occupied_cooling", "visualize": true, "export": true, "variable_type": "double" }, { "units": "hrs", "objective_function": false, "objective_function_index": 5, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Unmet Heating Hours", "display_name_short": "Unmet Heating Hours", "metadata_id": null, "name": "standard_reports.time_setpoint_not_met_during_occupied_heating", "visualize": true, "export": true, "variable_type": "double" }, { "units": "hrs", "objective_function": false, "objective_function_index": 6, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Total Unmet Hours", "display_name_short": "Total Unmet Hours", "metadata_id": null, "name": "standard_reports.time_setpoint_not_met_during_occupied_hours", "visualize": true, "export": true, "variable_type": "double" }, { "units": "m2", "objective_function": false, "objective_function_index": 7, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Building Area", "display_name_short": "Building Area", "metadata_id": null, "name": "standard_reports.total_building_area", "visualize": true, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 8, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Natural Gas Heating Intensity", "display_name_short": "Natural Gas Heating Intensity", "metadata_id": null, "name": "standard_report_legacy.heating_natural_gas", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 9, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Cooling Electricity Intensity", "display_name_short": "Cooling Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.cooling_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 10, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Interior Lighting Electricity Intensity", "display_name_short": "Interior Lighting Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.interior_lighting_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 11, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Exterior Lighting Electricity Intensity", "display_name_short": "Exterior Lighting Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.exterior_lighting_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 12, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Equipment Electricity Intensity", "display_name_short": "Equipment Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.interior_equipment_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 13, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Equipment Natural Gas Intensity", "display_name_short": "Equipment Natural Gas Intensity", "metadata_id": null, "name": "standard_report_legacy.interior_equipment_natural_gas", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 14, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Experior Equipment Electricity Intensity", "display_name_short": "Experior Equipment Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.exterior_equipment_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 15, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Fans Electricity Intensity", "display_name_short": "Fans Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.fans_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 16, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Pumps Electricity Intensity", "display_name_short": "Pumps Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.pumps_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 17, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Heat Rejection Electricity Intensity", "display_name_short": "Heat Rejection Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.heat_rejection_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 18, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Humidification Electricity Intensity", "display_name_short": "Humidification Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.humidification_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 19, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Water Systems Electricity Intensity", "display_name_short": "Water Systems Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.water_systems_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 20, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Water Systems Natural Gas Intensity", "display_name_short": "Water Systems Natural Gas Intensity", "metadata_id": null, "name": "standard_report_legacy.water_systems_natural_gas", "visualize": false, "export": true, "variable_type": "double" }, { "units": "MJ/m2", "objective_function": false, "objective_function_index": 21, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Refrigeration Electricity Intensity", "display_name_short": "Refrigeration Electricity Intensity", "metadata_id": null, "name": "standard_report_legacy.refrigeration_electricity", "visualize": false, "export": true, "variable_type": "double" }, { "units": "$", "objective_function": false, "objective_function_index": 22, "objective_function_target": null, "objective_function_group": null, "scaling_factor": null, "display_name": "Total Life Cycle Cost", "display_name_short": "Total Life Cycle Cost", "metadata_id": null, "name": "standard_report.total_life_cycle_cost", "visualize": true, "export": true, "variable_type": "double" } ], "problem": { "analysis_type": "lhs", "algorithm": { "sample_method": "all_variables", "number_of_samples": 5, "objective_functions": [ "standard_report_legacy.total_energy", "standard_report_legacy.total_source_energy" ] }, "workflow": [ { "name": "reduce_lighting_loads_by_percentage", "display_name": "Reduce Lighting Loads by Percentage", "measure_type": "RubyMeasure", "measure_definition_class_name": "ReduceLightingLoadsByPercentage", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Reduce Lighting Loads by Percentage", "measure_definition_name": "reduce_lighting_loads_by_percentage", "measure_definition_name_xml": null, "measure_definition_uuid": "f9d0b5ce-fb30-4bdd-8e12-c62bef6d8050", "measure_definition_version_uuid": "1e40c309-9cc1-43b3-beb9-b7973af08b52", "arguments": [ { "display_name": "Apply the Measure to a Specific Space Type or to the Entire Model.", "display_name_short": "Apply the Measure to a Specific Space Type or to the Entire Model.", "name": "space_type", "value_type": "string", "default_value": "*Entire Building*", "value": "*Entire Building*" }, { "display_name": "Increase in Material and Installation Cost for Lighting per Floor Area (%).", "display_name_short": "Increase in Material and Installation Cost for Lighting per Floor Area (%).", "name": "material_and_installation_cost", "value_type": "double", "default_value": 150.0, "value": 150.0 }, { "display_name": "Increase in Demolition Costs for Lighting per Floor Area (%).", "display_name_short": "Increase in Demolition Costs for Lighting per Floor Area (%).", "name": "demolition_cost", "value_type": "double", "default_value": 0.0, "value": 0.0 }, { "display_name": "Years Until Costs Start (whole years).", "display_name_short": "Years Until Costs Start (whole years).", "name": "years_until_costs_start", "value_type": "integer", "default_value": 0, "value": 0 }, { "display_name": "Demolition Costs Occur During Initial Construction?", "display_name_short": "Demolition Costs Occur During Initial Construction?", "name": "demo_cost_initial_const", "value_type": "bool", "default_value": false, "value": false }, { "display_name": "Expected Life (whole years).", "display_name_short": "Expected Life (whole years).", "name": "expected_life", "value_type": "integer", "default_value": 15, "value": 15 }, { "display_name": "Increase O & M Costs for Lighting per Floor Area (%).", "display_name_short": "Increase O & M Costs for Lighting per Floor Area (%).", "name": "om_cost", "value_type": "double", "default_value": 0.0, "value": 0.0 }, { "display_name": "O & M Frequency (whole years).", "display_name_short": "O & M Frequency (whole years).", "name": "om_frequency", "value_type": "integer", "default_value": 1, "value": 1 } ], "variables": [ { "argument": { "display_name": "LPD Reduction", "display_name_short": "LPD Reduction", "name": "lighting_power_reduction_percent", "value_type": "double", "default_value": 0.0, "value": 0.0 }, "display_name": "LPD Reduction", "display_name_short": "LPD Reduction", "variable_type": "variable", "units": null, "minimum": 0.0, "maximum": 70.0, "relation_to_output": null, "static_value": 0.0, "uuid": "02b10a85-89ad-459a-9160-614e50f1e258", "version_uuid": "f6f59ce9-e941-431e-8e83-5cf4f4a7c06e", "variable": true, "uncertainty_description": { "type": "triangle_uncertain", "attributes": [ { "name": "lower_bounds", "value": 0.0 }, { "name": "upper_bounds", "value": 70.0 }, { "name": "modes", "value": 20.0 }, { "name": "delta_x", "value": 5.0 }, { "name": "stddev", "value": 11.66666667 } ] }, "workflow_index": 0 } ], "workflow_index": 0 }, { "name": "rotate_building_relative_to_current_orientation", "display_name": "Rotate Building Relative to Current Orientation", "measure_type": "RubyMeasure", "measure_definition_class_name": "RotateBuilding", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Rotate Building Relative to Current Orientation", "measure_definition_name": "rotate_building_relative_to_current_orientation", "measure_definition_name_xml": null, "measure_definition_uuid": "ae9e2610-93e0-4388-b541-2161cba90a71", "measure_definition_version_uuid": "bfcbf501-b8aa-4670-8571-8e31c21fd0ca", "arguments": [ ], "variables": [ { "argument": { "display_name": "Rotation", "display_name_short": "Rotation", "name": "relative_building_rotation", "value_type": "double", "default_value": 0.0, "value": 0.0 }, "display_name": "Rotation", "display_name_short": "Rotation", "variable_type": "variable", "units": null, "minimum": 0.0, "maximum": 359.0, "relation_to_output": null, "static_value": 0.0, "uuid": "55672847-a401-4b94-9066-a0471a7dc358", "version_uuid": "4ce22500-88dc-4f62-940d-f2b48e2a00af", "variable": true, "uncertainty_description": { "type": "uniform_uncertain", "attributes": [ { "name": "lower_bounds", "value": 0.0 }, { "name": "upper_bounds", "value": 359.0 }, { "name": "modes", "value": 180.0 }, { "name": "delta_x", "value": null }, { "name": "stddev", "value": 59.83333333 } ] }, "workflow_index": 0 } ], "workflow_index": 1 }, { "name": "set_r_value_of_insulation_for_exterior_walls_to_a_specific_value", "display_name": "Set R-value of Insulation for Exterior Walls to a Specific Value", "measure_type": "RubyMeasure", "measure_definition_class_name": "IncreaseInsulationRValueForExteriorWalls", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Set R-value of Insulation for Exterior Walls to a Specific Value", "measure_definition_name": "set_r_value_of_insulation_for_exterior_walls_to_a_specific_value", "measure_definition_name_xml": null, "measure_definition_uuid": "5a317aa7-54f2-4355-b934-208e556e36b1", "measure_definition_version_uuid": "3904fdb7-145f-4862-884c-927aed325aa0", "arguments": [ { "display_name": "Increase in Material and Installation Costs for Construction per Area Used ($/ft^2).", "display_name_short": "Increase in Material and Installation Costs for Construction per Area Used ($/ft^2).", "name": "material_cost_increase_ip", "value_type": "double", "default_value": 0.0, "value": 0.0 }, { "display_name": "One Time Retrofit Cost to Add Insulation to Construction ($/ft^2).", "display_name_short": "One Time Retrofit Cost to Add Insulation to Construction ($/ft^2).", "name": "one_time_retrofit_cost_ip", "value_type": "double", "default_value": 0.0, "value": 0.0 }, { "display_name": "Year to Incur One Time Retrofit Cost (whole years).", "display_name_short": "Year to Incur One Time Retrofit Cost (whole years).", "name": "years_until_retrofit_cost", "value_type": "integer", "default_value": 0, "value": 0 } ], "variables": [ { "argument": { "display_name": "Wall R-Value", "display_name_short": "Wall R-Value", "name": "r_value", "value_type": "double", "default_value": 13.0, "value": 13.0 }, "display_name": "Wall R-Value", "display_name_short": "Wall R-Value", "variable_type": "variable", "units": null, "minimum": 0.0, "maximum": 50.0, "relation_to_output": null, "static_value": 13.0, "uuid": "2425614d-5c9d-4895-9395-d1b5212075c2", "version_uuid": "1d9cce42-1086-4df8-9509-59481cf05750", "variable": true, "uncertainty_description": { "type": "normal_uncertain", "attributes": [ { "name": "lower_bounds", "value": 0.0 }, { "name": "upper_bounds", "value": 50.0 }, { "name": "modes", "value": 25.0 }, { "name": "delta_x", "value": null }, { "name": "stddev", "value": 8.333333333 } ] }, "workflow_index": 0 } ], "workflow_index": 2 }, { "name": "set_r_value_of_insulation_for_roofs_to_a_specific_value", "display_name": "Set R-value of Insulation for Roofs to a Specific Value", "measure_type": "RubyMeasure", "measure_definition_class_name": "IncreaseInsulationRValueForRoofs", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Set R-value of Insulation for Roofs to a Specific Value", "measure_definition_name": "set_r_value_of_insulation_for_roofs_to_a_specific_value", "measure_definition_name_xml": null, "measure_definition_uuid": "3d9ccca5-1786-444f-85f8-77c7afd3fbfc", "measure_definition_version_uuid": "b7700680-7731-48fe-8d3d-badceae8aa42", "arguments": [ { "display_name": "Increase in Material and Installation Costs for Construction per Area Used ($/ft^2).", "display_name_short": "Increase in Material and Installation Costs for Construction per Area Used ($/ft^2).", "name": "material_cost_increase_ip", "value_type": "double", "default_value": 0.0, "value": 0.0 }, { "display_name": "One Time Retrofit Cost to Add Insulation to Construction ($/ft^2).", "display_name_short": "One Time Retrofit Cost to Add Insulation to Construction ($/ft^2).", "name": "one_time_retrofit_cost_ip", "value_type": "double", "default_value": 0.0, "value": 0.0 }, { "display_name": "Year to Incur One Time Retrofit Cost (whole years).", "display_name_short": "Year to Incur One Time Retrofit Cost (whole years).", "name": "years_until_retrofit_cost", "value_type": "integer", "default_value": 0, "value": 0 } ], "variables": [ { "argument": { "display_name": "Roof R-Value", "display_name_short": "Roof R-Value", "name": "r_value", "value_type": "double", "default_value": 10.0, "value": 10.0 }, "display_name": "Roof R-Value", "display_name_short": "Roof R-Value", "variable_type": "variable", "units": null, "minimum": 10.0, "maximum": 80.0, "relation_to_output": null, "static_value": 10.0, "uuid": "35a9890f-1ac4-44aa-9a31-d3876855aed2", "version_uuid": "c458e8e9-2ef0-410d-9540-d21eb74131de", "variable": true, "uncertainty_description": { "type": "discrete_uncertain", "attributes": [ { "name": "discrete", "values_and_weights": [ { "value": 10, "weight": 0.05 }, { "value": 30, "weight": 0.1 }, { "value": 50, "weight": 0.45 }, { "value": 80, "weight": 0.4 } ] }, { "name": "lower_bounds", "value": 10.0 }, { "name": "upper_bounds", "value": 80.0 }, { "name": "modes", "value": 50.0 }, { "name": "delta_x", "value": null }, { "name": "stddev", "value": 10.0 } ] }, "workflow_index": 0 } ], "workflow_index": 3 }, { "name": "window_to_wall_ratio_south", "display_name": "Window to Wall Ratio South", "measure_type": "RubyMeasure", "measure_definition_class_name": "SetWindowToWallRatioByFacade", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Window to Wall Ratio South", "measure_definition_name": "window_to_wall_ratio_south", "measure_definition_name_xml": null, "measure_definition_uuid": "12e72c76-40cb-4537-bc48-cefb3e654506", "measure_definition_version_uuid": "9e832c6f-30e0-4729-944e-9be73d8167ea", "arguments": [ { "display_name": "Sill Height (in).", "display_name_short": "Sill Height (in).", "name": "sillHeight", "value_type": "double", "default_value": 30.0, "value": 30.0 }, { "display_name": "Cardinal Direction.", "display_name_short": "Cardinal Direction.", "name": "facade", "value_type": "string", "default_value": "South", "value": "South" } ], "variables": [ { "argument": { "display_name": "South WWR", "display_name_short": "South WWR", "name": "wwr", "value_type": "double", "default_value": 0.4, "value": 0.4 }, "display_name": "South WWR", "display_name_short": "South WWR", "variable_type": "variable", "units": null, "minimum": 0.05, "maximum": 0.95, "relation_to_output": null, "static_value": 0.4, "uuid": "568cf664-3ac4-4507-a8ea-faaed14500c4", "version_uuid": "cb0ff149-9425-42c4-85b2-83174bdb920e", "variable": true, "uncertainty_description": { "type": "triangle_uncertain", "attributes": [ { "name": "lower_bounds", "value": 0.05 }, { "name": "upper_bounds", "value": 0.95 }, { "name": "modes", "value": 0.4 }, { "name": "delta_x", "value": null }, { "name": "stddev", "value": 0.15 } ] }, "workflow_index": 0 } ], "workflow_index": 4 }, { "name": "window_to_wall_ratio_west", "display_name": "Window to Wall Ratio West", "measure_type": "RubyMeasure", "measure_definition_class_name": "SetWindowToWallRatioByFacade", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Window to Wall Ratio West", "measure_definition_name": "window_to_wall_ratio_west", "measure_definition_name_xml": null, "measure_definition_uuid": "27265d0c-073b-4c0e-82fd-45d3613067ea", "measure_definition_version_uuid": "36e3f07c-48b7-4b33-bb47-0af79ee9347c", "arguments": [ { "display_name": "Sill Height (in).", "display_name_short": "Sill Height (in).", "name": "sillHeight", "value_type": "double", "default_value": 30.0, "value": 30.0 }, { "display_name": "Cardinal Direction.", "display_name_short": "Cardinal Direction.", "name": "facade", "value_type": "string", "default_value": "West", "value": "West" } ], "variables": [ { "argument": { "display_name": "West WWR", "display_name_short": "West WWR", "name": "wwr", "value_type": "double", "default_value": 0.4, "value": 0.4 }, "display_name": "West WWR", "display_name_short": "West WWR", "variable_type": "variable", "units": null, "minimum": 0.05, "maximum": 0.95, "relation_to_output": null, "static_value": 0.4, "uuid": "73b1af0d-d7f5-4aee-a7fb-975786a5f7e5", "version_uuid": "b56bda14-5f19-4d54-a0d4-031af8ddb64b", "variable": true, "uncertainty_description": { "type": "triangle_uncertain", "attributes": [ { "name": "lower_bounds", "value": 0.05 }, { "name": "upper_bounds", "value": 0.95 }, { "name": "modes", "value": 0.4 }, { "name": "delta_x", "value": null }, { "name": "stddev", "value": 0.15 } ] }, "workflow_index": 0 } ], "workflow_index": 5 }, { "name": "window_to_wall_ratio_east", "display_name": "Window to Wall Ratio East", "measure_type": "RubyMeasure", "measure_definition_class_name": "SetWindowToWallRatioByFacade", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Window to Wall Ratio East", "measure_definition_name": "window_to_wall_ratio_east", "measure_definition_name_xml": null, "measure_definition_uuid": "3a27abdf-685a-40c0-b61b-7f33c2b05cc9", "measure_definition_version_uuid": "1a12270f-162b-4497-b297-29c01f16a04d", "arguments": [ { "display_name": "Sill Height (in).", "display_name_short": "Sill Height (in).", "name": "sillHeight", "value_type": "double", "default_value": 30.0, "value": 30.0 }, { "display_name": "Cardinal Direction.", "display_name_short": "Cardinal Direction.", "name": "facade", "value_type": "string", "default_value": "East", "value": "East" } ], "variables": [ { "argument": { "display_name": "East WWR", "display_name_short": "East WWR", "name": "wwr", "value_type": "double", "default_value": 0.4, "value": 0.4 }, "display_name": "East WWR", "display_name_short": "East WWR", "variable_type": "variable", "units": null, "minimum": 0.05, "maximum": 0.95, "relation_to_output": null, "static_value": 0.4, "uuid": "d95e762f-7b55-40c4-af95-64d2953b9be7", "version_uuid": "8967294d-2375-4c12-a044-a95b564e8972", "variable": true, "uncertainty_description": { "type": "triangle_uncertain", "attributes": [ { "name": "lower_bounds", "value": 0.05 }, { "name": "upper_bounds", "value": 0.95 }, { "name": "modes", "value": 0.4 }, { "name": "delta_x", "value": null }, { "name": "stddev", "value": 0.15 } ] }, "workflow_index": 0 } ], "workflow_index": 6 }, { "name": "overhangs_pf_south", "display_name": "Overhangs PF South", "measure_type": "RubyMeasure", "measure_definition_class_name": "AddOverhangsByProjectionFactor", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Overhangs PF South", "measure_definition_name": "overhangs_pf_south", "measure_definition_name_xml": null, "measure_definition_uuid": "1f2cde0d-a887-456f-bcb0-bad38d6be5ee", "measure_definition_version_uuid": "385ea348-44db-4ce8-9108-8160b776d6cf", "arguments": [ { "display_name": "Cardinal Direction", "display_name_short": "Cardinal Direction", "name": "facade", "value_type": "string", "default_value": "South", "value": "South" }, { "display_name": "Remove Existing Space Shading Surfaces From the Model?", "display_name_short": "Remove Existing Space Shading Surfaces From the Model?", "name": "remove_ext_space_shading", "value_type": "bool", "default_value": false, "value": false }, { "display_name": "Optionally Choose a Construction for the Overhangs.", "display_name_short": "Optionally Choose a Construction for the Overhangs.", "name": "construction", "value_type": "string", "default_value": null, "value": null } ], "variables": [ { "argument": { "display_name": "South Projection Factor", "display_name_short": "South PF", "name": "projection_factor", "value_type": "integer", "default_value": 0, "value": 0 }, "display_name": "South Projection Factor", "display_name_short": "South PF", "variable_type": "variable", "units": null, "minimum": 0, "maximum": 10, "relation_to_output": null, "static_value": 0, "uuid": "45d81f45-021f-4ff5-b9b9-a04875a5fab7", "version_uuid": "1265016f-9be1-4bba-8702-f5b2ca5b38e0", "variable": true, "uncertainty_description": { "type": "discrete_uncertain", "attributes": [ { "name": "discrete", "values_and_weights": [ { "value": 1, "weight": 0.25 }, { "value": 2, "weight": 0.25 }, { "value": 3, "weight": 0.25 }, { "value": 4, "weight": 0.25 } ] }, { "name": "lower_bounds", "value": 0 }, { "name": "upper_bounds", "value": 10 }, { "name": "modes", "value": 5 }, { "name": "delta_x", "value": null }, { "name": "stddev", "value": 1 } ] }, "workflow_index": 0 } ], "workflow_index": 7 }, { "name": "overhangs_pf_east", "display_name": "Overhangs PF East", "measure_type": "RubyMeasure", "measure_definition_class_name": "AddOverhangsByProjectionFactor", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Overhangs PF East", "measure_definition_name": "overhangs_pf_east", "measure_definition_name_xml": null, "measure_definition_uuid": "c77f8102-3bff-400b-bdf0-a951e8a5d682", "measure_definition_version_uuid": "a9088906-f7a1-41e3-8c0f-f3aba6363ca3", "arguments": [ { "display_name": "Cardinal Direction", "display_name_short": "Cardinal Direction", "name": "facade", "value_type": "string", "default_value": "East", "value": "East" }, { "display_name": "Optionally Choose a Construction for the Overhangs.", "display_name_short": "Optionally Choose a Construction for the Overhangs.", "name": "construction", "value_type": "string", "default_value": null, "value": null } ], "variables": [ { "argument": { "display_name": "East Projection Factor", "display_name_short": "East PF", "name": "projection_factor", "value_type": "double", "default_value": 0.0, "value": 0.0 }, "display_name": "East Projection Factor", "display_name_short": "East PF", "variable_type": "variable", "units": null, "minimum": 0.0, "maximum": 1.0, "relation_to_output": null, "static_value": 0.0, "uuid": "6b929e30-a178-42ff-813e-a389553f2f9f", "version_uuid": "5b099929-4084-4d43-bbd5-0db939218c56", "variable": true, "uncertainty_description": { "type": "uniform_uncertain", "attributes": [ { "name": "lower_bounds", "value": 0.0 }, { "name": "upper_bounds", "value": 1.0 }, { "name": "modes", "value": 0.5 }, { "name": "delta_x", "value": null }, { "name": "stddev", "value": 0.133333333 } ] }, "workflow_index": 0 }, { "argument": { "display_name": "Remove Existing Space Shading Surfaces From the Model?", "display_name_short": "Remove Existing Space Shading Surfaces From the Model?", "name": "remove_ext_space_shading", "value_type": "bool", "default_value": false, "value": false }, "display_name": "Remove Existing Space Shading Surfaces From the Model?", "display_name_short": "Remove Existing Space Shading Surfaces From the Model?", "variable_type": "variable", "units": null, "minimum": false, "maximum": true, "relation_to_output": null, "uuid": "d12821e6-e18c-49fd-b599-2998a5be871d", "version_uuid": "ad4837f7-d0c4-4af7-b190-0bcd81340a56", "variable": true, "static_value": false, "uncertainty_description": { "type": "discrete_uncertain", "attributes": [ { "name": "discrete", "values_and_weights": [ { "value": false, "weight": 0.5 }, { "value": true, "weight": 0.5 } ] }, { "name": "lower_bounds", "value": false }, { "name": "upper_bounds", "value": true }, { "name": "modes", "value": true }, { "name": "delta_x", "value": null }, { "name": "stddev", "value": true } ] }, "workflow_index": 1 } ], "workflow_index": 8 }, { "name": "xcel_eda_tariff_selection_and_model_setup", "display_name": "Xcel EDA Tariff Selection and Model Setup", "measure_type": "EnergyPlusMeasure", "measure_definition_class_name": "XcelEDATariffSelectionandModelSetup", "measure_definition_directory": "./measures/SetThermostatSchedules", "measure_definition_directory_local": "/Users/nlong/working/OpenStudio-analysis-gem/spec/files/measures/SetThermostatSchedules", "measure_definition_display_name": "Xcel EDA Tariff Selection and Model Setup", "measure_definition_name": "xcel_eda_tariff_selection_and_model_setup", "measure_definition_name_xml": null, "measure_definition_uuid": "7f146f69-ad4c-4404-a846-222f40cd2739", "measure_definition_version_uuid": "72427701-470b-41d1-a22b-82df578af80e", "arguments": [ { "display_name": "Select an Electricity Tariff.", "display_name_short": "Select an Electricity Tariff.", "name": "elec_tar", "value_type": "string", "default_value": "Secondary General", "value": "Secondary General" }, { "display_name": "Select a Gas Tariff.", "display_name_short": "Select a Gas Tariff.", "name": "gas_tar", "value_type": "string", "default_value": "Large CG", "value": "Large CG" } ], "variables": [ ], "workflow_index": 9 } ] }, "seed": { "file_type": "OSM", "path": "./seed/small_seed.osm" }, "weather_file": { "file_type": "EPW", "path": "./weather/partial_weather.epw" }, "file_format_version": 1 } }