# Custom changes for the PrimarySchool prototype. # These are changes that are inconsistent with other prototype # building types. module PrimarySchool def model_custom_hvac_tweaks(building_type, climate_zone, prototype_input, model) OpenStudio.logFree(OpenStudio::Info, 'openstudio.model.Model', 'Started building type specific adjustments') # add transformer transformer_efficiency = nil case template when '90.1-2004', '90.1-2007' transformer_efficiency = 0.969 when '90.1-2010', '90.1-2013' transformer_efficiency = 0.982 end return true unless !transformer_efficiency.nil? model_add_transformer(model, wired_lighting_frac: 0.0119, transformer_size: 112500, transformer_efficiency: transformer_efficiency) # # add extra equipment for kitchen add_extra_equip_kitchen(model) return true end # add extra equipment for kitchen def add_extra_equip_kitchen(model) kitchen_space = model.getSpaceByName('Kitchen_ZN_1_FLR_1') kitchen_space = kitchen_space.get kitchen_space_type = kitchen_space.spaceType.get elec_equip_def1 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def2 = OpenStudio::Model::ElectricEquipmentDefinition.new(model) elec_equip_def1.setName('Kitchen Electric Equipment Definition1') elec_equip_def2.setName('Kitchen Electric Equipment Definition2') case template when '90.1-2004', '90.1-2007', '90.1-2010', '90.1-2013' elec_equip_def1.setFractionLatent(0) elec_equip_def1.setFractionRadiant(0.25) elec_equip_def1.setFractionLost(0) elec_equip_def2.setFractionLatent(0) elec_equip_def2.setFractionRadiant(0.25) elec_equip_def2.setFractionLost(0) if template == '90.1-2013' elec_equip_def1.setDesignLevel(915) elec_equip_def2.setDesignLevel(570) else elec_equip_def1.setDesignLevel(1032) elec_equip_def2.setDesignLevel(852) end # Create the electric equipment instance and hook it up to the space type elec_equip1 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def1) elec_equip2 = OpenStudio::Model::ElectricEquipment.new(elec_equip_def2) elec_equip1.setName('Kitchen_Reach-in-Freezer') elec_equip2.setName('Kitchen_Reach-in-Refrigerator') elec_equip1.setSpaceType(kitchen_space_type) elec_equip2.setSpaceType(kitchen_space_type) elec_equip1.setSchedule(model_add_schedule(model, 'SchoolPrimary ALWAYS_ON')) elec_equip2.setSchedule(model_add_schedule(model, 'SchoolPrimary ALWAYS_ON')) end end def update_waterheater_ambient_parameters(model) model.getWaterHeaterMixeds.sort.each do |water_heater| if water_heater.name.to_s.include?('Booster') water_heater.resetAmbientTemperatureSchedule water_heater.setAmbientTemperatureIndicator('ThermalZone') water_heater.setAmbientTemperatureThermalZone(model.getThermalZoneByName('Kitchen_ZN_1_FLR_1 ZN').get) end end end def model_custom_swh_tweaks(model, building_type, climate_zone, prototype_input) update_waterheater_ambient_parameters(model) return true end def model_custom_geometry_tweaks(building_type, climate_zone, prototype_input, model) return true end def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area) min_damper_position = template == '90.1-2010' || template == '90.1-2013' ? 0.2 : 0.3 # Set the minimum flow fraction air_terminal_single_duct_vav_reheat.setConstantMinimumAirFlowFraction(min_damper_position) return true end end