enable_economizer_control
f8cc920d-8ae3-411a-922f-e6fed3223c4d
757f6c26-b1d2-4dc4-82d6-96d2e37fb56d
20191029T231254Z
ECE70A70
EnableEconomizerControl
Enable Economizer Control
There is currently not a functioning air side economizer enabled in the building. Air side economizers use cold outside air to either assist the mechanical cooling system, or if the air is cold enough, provide all of the cooling for a facility.
In order for an air side economizer to function properly, all of the outside air damper actuators need to have modulating capabilities. In addition to that, new control sequences need to be written into the building automation control system to enable the air-side economizer when outside air temperatures are below 60?F-65?F and the interior space temperatures are calling for cooling.
The building would realize the following operational benefits by utilizing an air-side economizer:
-Reduction in cooling system energy use
-Reduction in mechanical cooling system run time
-Possible improvement in indoor air quality
This measure will enable economizer control for one or all of the air loops in the building. The choice list will have the following choices: No Economizer, Fixed Dry Bulb, Fixed Enthalpy, Differential Dry Bulb, Differential Enthalpy, Fixed Dew Point and Dry Bulb, Differential Dew Point and Dry Bulb, and Electronic Enthalpy. The default choice for each system will be the initial system condition. The measure will also have optional user argument fields for Economizer Maximum Limit Dry-Bulb Temperature, Economizer Maximum Limit Enthalpy, Economizer Maximum Limit Dewpoint Temperature, Economizer Minimum Limit Dry-Bulb Temperature. These user arguments get applied to every system in the project.
If the HVAC system does not have an OS:AirLoopHVAC:OutdoorAirSystem, then the runner sends an info message to the user that the model was not changed.
The cost arguments are user arguments that start with a default of $0.
economizer_type
Economizer Control Type
Choice
true
false
FixedDryBulb
FixedDryBulb
NoEconomizer
NoEconomizer
NoChange
NoChange
econoMaxDryBulbTemp
Economizer Maximum Limit Dry-Bulb Temperature (F).
Double
true
false
69
econoMinDryBulbTemp
Economizer Minimum Limit Dry-Bulb Temperature (F).
Double
true
false
-148
HVAC.Ventilation
Measure Type
ModelMeasure
string
Uses SketchUp API
false
boolean
0320_ModelWithHVAC_01.osm
osm
test
4A5352A1
README.md.erb
erb
readmeerb
703C9964
README.md
md
readme
CF61C43C
OpenStudio
2.0.0
2.0.0
measure.rb
rb
script
E1B5F00B
LICENSE.md
md
license
D41C05CF
measure_Test.rb
rb
test
968703DA