class NRELZNEReady2017 < ASHRAE901
  # @!group elevators

  # Determines the percentage of the elevator cab lighting that is incandescent.
  # The remainder is assumed to be LED.
  # Defaults to 0% incandescent (100% LED), representing newer elevators.
  #
  # @param model [OpenStudio::Model::Model] OpenStudio model object
  # @return [Double] incandescent lighting percentage
  def model_elevator_lighting_pct_incandescent(model)
    pct_incandescent = 0.0 # 100% LED
    return pct_incandescent
  end

  # Determines the power of the elevator ventilation fan.
  # Same as 90.1-2013, which has a requirement for ventilation fan efficiency.
  #
  # @param model [OpenStudio::Model::Model] OpenStudio model object
  # @param vent_rate_cfm [Double] the ventilation rate in ft^3/min
  # @return [Double] the ventilation fan power in watts
  def model_elevator_fan_pwr(model, vent_rate_cfm)
    vent_pwr_per_flow_w_per_cfm = 0.33
    vent_pwr_w = vent_pwr_per_flow_w_per_cfm * vent_rate_cfm
    # addendum 90.1-2007 aj has requirement on efficiency
    vent_pwr_w = vent_pwr_w * 0.29 / 0.70

    return vent_pwr_w
  end
end

Version data entries

19 entries across 19 versions & 1 rubygems

Version Path
openstudio-standards-0.7.0 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.7.0.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.6.3 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.6.0.rc2 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.6.0.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.5.0 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.5.0.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.4.0 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.3.1.rc2 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.3.1.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.3.0 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.2.17.rc2 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.2.17.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.2.16 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.2.16.rc2 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.2.16.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.2.15 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.2.15.pre.rc2 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb
openstudio-standards-0.2.15.pre.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/nrel_nze_ready_2017/nrel_zne_ready_2017.Model.elevators.rb