# open the class to add methods to size all HVAC equipment class OpenStudio::Model::Model # Ensure that the version of OpenStudio is 1.6.0 or greater # because the HVACSizing .autosizedFoo methods are currently built # expecting the EnergyPlus 8.2 syntax. min_os_version = "1.6.0" if OpenStudio::Model::Model.new.version < OpenStudio::VersionString.new(min_os_version) OpenStudio::logFree(OpenStudio::Error, "openstudio.model.Model", "This measure requires a minimum OpenStudio version of #{min_os_version} because the HVACSizing .autosizedFoo methods expect EnergyPlus 8.2 output variable names.") end # Load the helper libraries for getting the autosized # values for each type of model object. require_relative 'Siz.AirTermSnglDuctParallelPIUReheat' require_relative 'Siz.AirTermSnglDuctVAVReheat' require_relative 'Siz.AirTermSnglDuctUncontrolled' require_relative 'Siz.AirLoopHVAC' require_relative 'Siz.AirLoopHVACUnitaryHeatPumpAirToAir' require_relative 'Siz.AirLoopHVACUnitaryHeatPumpAirToAirMultiSpeed' require_relative 'Siz.FanConstantVolume' require_relative 'Siz.FanVariableVolume' require_relative 'Siz.FanOnOff' require_relative 'Siz.CoilHeatingElectric' require_relative 'Siz.CoilHeatingGas' require_relative 'Siz.CoilHeatingGasMultiStage' require_relative 'Siz.CoilHeatingWater' require_relative 'Siz.CoilHeatingDXSingleSpeed' require_relative 'Siz.CoilHeatingDXMultiSpeed' require_relative 'Siz.CoilHeatingWaterToAirHeatPumpEquationFit' require_relative 'Siz.CoilCoolingWaterToAirHeatPumpEquationFit' require_relative 'Siz.CoilCoolingDXMultiSpeed' require_relative 'Siz.CoilCoolingDXSingleSpeed' require_relative 'Siz.CoilCoolingDXTwoSpeed' require_relative 'Siz.CoilCoolingWater' require_relative 'Siz.ControllerOutdoorAir' require_relative 'Siz.DistrictHeating' require_relative 'Siz.DistrictCooling' require_relative 'Siz.HeatExchangerAirToAirSensibleAndLatent' require_relative 'Siz.PlantLoop' require_relative 'Siz.PumpConstantSpeed' require_relative 'Siz.PumpVariableSpeed' require_relative 'Siz.BoilerHotWater' require_relative 'Siz.ChillerElectricEIR' require_relative 'Siz.CoolingTowerSingleSpeed' require_relative 'Siz.CoolingTowerTwoSpeed' require_relative 'Siz.CoolingTowerVariableSpeed' require_relative 'Siz.ControllerWaterCoil' require_relative 'Siz.SizingSystem' require_relative 'Siz.ThermalZone' require_relative 'Siz.ZoneHVACPackagedTerminalAirConditioner' require_relative 'Siz.ZoneHVACPackagedTerminalHeatPump' require_relative 'Siz.ZoneHVACTerminalUnitVariableRefrigerantFlow' require_relative 'Siz.AirConditionerVariableRefrigerantFlow' require_relative 'Siz.CoilCoolingDXVariableRefrigerantFlow' require_relative 'Siz.CoilHeatingDXVariableRefrigerantFlow' require_relative 'Siz.HeaderedPumpsConstantSpeed' require_relative 'Siz.HeaderedPumpsVariableSpeed' # Heating and cooling fuel methods require_relative 'Siz.HeatingCoolingFuels' # Component quantity methods require_relative 'Siz.HVACComponent' # Takes the values calculated by the EnergyPlus sizing routines # and puts them into all objects model in place of the autosized fields. # Must have previously completed a run with sql output for this to work. def applySizingValues # Ensure that the model has a sql file associated with it if self.sqlFile.empty? OpenStudio::logFree(OpenStudio::Error, 'openstudio.model.Model', 'Failed to apply sizing values because model is missing sql file containing sizing results.') return false end # @todo Sizing methods for these types of equipment are # currently only stubs that need to be filled in. self.getAirConditionerVariableRefrigerantFlows.sort.each {|obj| obj.applySizingValues} self.getAirLoopHVACUnitaryHeatCoolVAVChangeoverBypasss.sort.each {|obj| obj.applySizingValues} self.getAirLoopHVACUnitarySystems.sort.each {|obj| obj.applySizingValues} self.getAirTerminalSingleDuctConstantVolumeCooledBeams.sort.each {|obj| obj.applySizingValues} self.getAirTerminalSingleDuctConstantVolumeFourPipeInductions.sort.each {|obj| obj.applySizingValues} self.getAirTerminalSingleDuctConstantVolumeReheats.sort.each {|obj| obj.applySizingValues} self.getAirTerminalSingleDuctSeriesPIUReheats.sort.each {|obj| obj.applySizingValues} self.getAirTerminalSingleDuctVAVHeatAndCoolNoReheats.sort.each {|obj| obj.applySizingValues} self.getAirTerminalSingleDuctVAVHeatAndCoolReheats.sort.each {|obj| obj.applySizingValues} self.getBoilerSteams.sort.each {|obj| obj.applySizingValues} self.getCoilCoolingDXVariableRefrigerantFlows.sort.each {|obj| obj.applySizingValues} self.getCoilCoolingWaterToAirHeatPumpEquationFits.sort.each {|obj| obj.applySizingValues} self.getCoilHeatingWaterToAirHeatPumpEquationFits.sort.each {|obj| obj.applySizingValues} self.getCoilHeatingDesuperheaters.sort.each {|obj| obj.applySizingValues} self.getCoilHeatingDXVariableRefrigerantFlows.sort.each {|obj| obj.applySizingValues} self.getCoilWaterHeatingDesuperheaters.sort.each {|obj| obj.applySizingValues} self.getCoolingTowerTwoSpeeds.sort.each {|obj| obj.applySizingValues} self.getCoolingTowerVariableSpeeds.sort.each {|obj| obj.applySizingValues} self.getEvaporativeCoolerDirectResearchSpecials.sort.each {|obj| obj.applySizingValues} self.getEvaporativeCoolerIndirectResearchSpecials.sort.each {|obj| obj.applySizingValues} self.getEvaporativeFluidCoolerSingleSpeeds.sort.each {|obj| obj.applySizingValues} self.getHeatExchangerFluidToFluids.sort.each {|obj| obj.applySizingValues} self.getHumidifierSteamElectrics.sort.each {|obj| obj.applySizingValues} self.getZoneHVACBaseboardConvectiveElectrics.sort.each {|obj| obj.applySizingValues} self.getZoneHVACBaseboardConvectiveWaters.sort.each {|obj| obj.applySizingValues} self.getZoneHVACFourPipeFanCoils.sort.each {|obj| obj.applySizingValues} self.getZoneHVACHighTemperatureRadiants.sort.each {|obj| obj.applySizingValues} self.getZoneHVACIdealLoadsAirSystems.sort.each {|obj| obj.applySizingValues} self.getZoneHVACLowTemperatureRadiantElectrics.sort.each {|obj| obj.applySizingValues} self.getZoneHVACLowTempRadiantConstFlows.sort.each {|obj| obj.applySizingValues} self.getZoneHVACLowTempRadiantVarFlows.sort.each {|obj| obj.applySizingValues} self.getZoneHVACPackagedTerminalAirConditioners.sort.each {|obj| obj.applySizingValues} self.getZoneHVACPackagedTerminalHeatPumps.sort.each {|obj| obj.applySizingValues} self.getZoneHVACTerminalUnitVariableRefrigerantFlows.sort.each {|obj| obj.applySizingValues} self.getZoneHVACWaterToAirHeatPumps.sort.each {|obj| obj.applySizingValues} # Zone equipment # Air terminals self.getAirTerminalSingleDuctParallelPIUReheats.sort.each {|obj| obj.applySizingValues} self.getAirTerminalSingleDuctVAVReheats.sort.each {|obj| obj.applySizingValues} self.getAirTerminalSingleDuctUncontrolleds.sort.each {|obj| obj.applySizingValues} # AirLoopHVAC components self.getAirLoopHVACs.sort.each {|obj| obj.applySizingValues} self.getSizingSystems.sort.each {|obj| obj.applySizingValues} # Fans self.getFanConstantVolumes.sort.each {|obj| obj.applySizingValues} self.getFanVariableVolumes.sort.each {|obj| obj.applySizingValues} self.getFanOnOffs.sort.each {|obj| obj.applySizingValues} # Heating coils self.getCoilHeatingElectrics.sort.each {|obj| obj.applySizingValues} self.getCoilHeatingGass.sort.each {|obj| obj.applySizingValues} self.getCoilHeatingGasMultiStages.sort.each {|obj| obj.applySizingValues} self.getCoilHeatingWaters.sort.each {|obj| obj.applySizingValues} self.getCoilHeatingDXSingleSpeeds.sort.each {|obj| obj.applySizingValues} self.getCoilHeatingDXMultiSpeeds.sort.each {|obj| obj.applySizingValues} # Cooling coils self.getCoilCoolingDXSingleSpeeds.sort.each {|obj| obj.applySizingValues} self.getCoilCoolingDXTwoSpeeds.sort.each {|obj| obj.applySizingValues} self.getCoilCoolingWaters.sort.each {|obj| obj.applySizingValues} self.getCoilCoolingDXMultiSpeeds.sort.each {|obj| obj.applySizingValues} # Outdoor air self.getControllerOutdoorAirs.sort.each {|obj| obj.applySizingValues} self.getHeatExchangerAirToAirSensibleAndLatents.sort.each {|obj| obj.applySizingValues} # PlantLoop components self.getPlantLoops.sort.each {|obj| obj.applySizingValues} # Pumps self.getPumpConstantSpeeds.sort.each {|obj| obj.applySizingValues} self.getPumpVariableSpeeds.sort.each {|obj| obj.applySizingValues} # Heating equipment self.getBoilerHotWaters.sort.each {|obj| obj.applySizingValues} # Cooling equipment self.getChillerElectricEIRs.sort.each {|obj| obj.applySizingValues} # Condenser equipment self.getCoolingTowerSingleSpeeds.sort.each {|obj| obj.applySizingValues} # Controls self.getControllerWaterCoils.sort.each {|obj| obj.applySizingValues} # VRF components # Refrigeration components return true end # Changes all hard-sized HVAC values to Autosized def autosize # @todo Sizing methods for these types of equipment are # currently only stubs that need to be filled in. self.getAirConditionerVariableRefrigerantFlows.sort.each {|obj| obj.autosize} self.getAirLoopHVACUnitaryHeatCoolVAVChangeoverBypasss.sort.each {|obj| obj.autosize} self.getAirLoopHVACUnitarySystems.sort.each {|obj| obj.autosize} self.getAirTerminalSingleDuctConstantVolumeCooledBeams.sort.each {|obj| obj.autosize} self.getAirTerminalSingleDuctConstantVolumeFourPipeInductions.sort.each {|obj| obj.autosize} self.getAirTerminalSingleDuctConstantVolumeReheats.sort.each {|obj| obj.autosize} self.getAirTerminalSingleDuctSeriesPIUReheats.sort.each {|obj| obj.autosize} self.getAirTerminalSingleDuctVAVHeatAndCoolNoReheats.sort.each {|obj| obj.autosize} self.getAirTerminalSingleDuctVAVHeatAndCoolReheats.sort.each {|obj| obj.autosize} self.getBoilerSteams.sort.each {|obj| obj.autosize} self.getCoilCoolingDXMultiSpeeds.sort.each {|obj| obj.autosize} self.getCoilCoolingDXVariableRefrigerantFlows.sort.each {|obj| obj.autosize} self.getCoilCoolingWaterToAirHeatPumpEquationFits.sort.each {|obj| obj.autosize} self.getCoilHeatingWaterToAirHeatPumpEquationFits.sort.each {|obj| obj.autosize} self.getCoilHeatingGasMultiStages.sort.each {|obj| obj.autosize} self.getCoilHeatingDesuperheaters.sort.each {|obj| obj.autosize} self.getCoilHeatingDXVariableRefrigerantFlows.sort.each {|obj| obj.autosize} self.getCoilWaterHeatingDesuperheaters.sort.each {|obj| obj.autosize} self.getCoolingTowerTwoSpeeds.sort.each {|obj| obj.autosize} self.getCoolingTowerVariableSpeeds.sort.each {|obj| obj.autosize} self.getEvaporativeCoolerDirectResearchSpecials.sort.each {|obj| obj.autosize} self.getEvaporativeCoolerIndirectResearchSpecials.sort.each {|obj| obj.autosize} self.getEvaporativeFluidCoolerSingleSpeeds.sort.each {|obj| obj.autosize} self.getHeatExchangerFluidToFluids.sort.each {|obj| obj.autosize} self.getHumidifierSteamElectrics.sort.each {|obj| obj.autosize} self.getZoneHVACBaseboardConvectiveElectrics.sort.each {|obj| obj.autosize} self.getZoneHVACBaseboardConvectiveWaters.sort.each {|obj| obj.autosize} self.getZoneHVACFourPipeFanCoils.sort.each {|obj| obj.autosize} self.getZoneHVACHighTemperatureRadiants.sort.each {|obj| obj.autosize} self.getZoneHVACIdealLoadsAirSystems.sort.each {|obj| obj.autosize} self.getZoneHVACLowTemperatureRadiantElectrics.sort.each {|obj| obj.autosize} self.getZoneHVACLowTempRadiantConstFlows.sort.each {|obj| obj.autosize} self.getZoneHVACLowTempRadiantVarFlows.sort.each {|obj| obj.autosize} self.getZoneHVACPackagedTerminalAirConditioners.sort.each {|obj| obj.autosize} self.getZoneHVACPackagedTerminalHeatPumps.sort.each {|obj| obj.autosize} self.getZoneHVACTerminalUnitVariableRefrigerantFlows.sort.each {|obj| obj.autosize} self.getZoneHVACWaterToAirHeatPumps.sort.each {|obj| obj.autosize} # Zone equipment # Air terminals self.getAirTerminalSingleDuctParallelPIUReheats.sort.each {|obj| obj.autosize} self.getAirTerminalSingleDuctVAVReheats.sort.each {|obj| obj.autosize} self.getAirTerminalSingleDuctUncontrolleds.sort.each {|obj| obj.autosize} # AirLoopHVAC components self.getAirLoopHVACs.sort.each {|obj| obj.autosize} self.getSizingSystems.sort.each {|obj| obj.autosize} # Fans self.getFanConstantVolumes.sort.each {|obj| obj.autosize} self.getFanVariableVolumes.sort.each {|obj| obj.autosize} self.getFanOnOffs.sort.each {|obj| obj.autosize} # Heating coils self.getCoilHeatingElectrics.sort.each {|obj| obj.autosize} self.getCoilHeatingGass.sort.each {|obj| obj.autosize} self.getCoilHeatingWaters.sort.each {|obj| obj.autosize} self.getCoilHeatingDXSingleSpeeds.sort.each {|obj| obj.autosize} # Cooling coils self.getCoilCoolingDXSingleSpeeds.sort.each {|obj| obj.autosize} self.getCoilCoolingDXTwoSpeeds.sort.each {|obj| obj.autosize} self.getCoilCoolingWaters.sort.each {|obj| obj.autosize} # Outdoor air self.getControllerOutdoorAirs.sort.each {|obj| obj.autosize} self.getHeatExchangerAirToAirSensibleAndLatents.sort.each {|obj| obj.autosize} # PlantLoop components self.getPlantLoops.sort.each {|obj| obj.autosize} # Pumps self.getPumpConstantSpeeds.sort.each {|obj| obj.autosize} self.getPumpVariableSpeeds.sort.each {|obj| obj.autosize} # Heating equipment self.getBoilerHotWaters.sort.each {|obj| obj.autosize} # Cooling equipment self.getChillerElectricEIRs.sort.each {|obj| obj.autosize} # Condenser equipment self.getCoolingTowerSingleSpeeds.sort.each {|obj| obj.autosize} # Controls self.getControllerWaterCoils.sort.each {|obj| obj.autosize} # VRF components # Refrigeration components return true end # A helper method to get component sizes from the model # returns the autosized value as an optional double def getAutosizedValue(object, value_name, units) result = OpenStudio::OptionalDouble.new name = object.name.get.upcase object_type = object.iddObject.type.valueDescription.gsub('OS:','') # Special logic for two coil types which are inconsistently # uppercase in the sqlfile: object_type = object_type.upcase if object_type == 'Coil:Cooling:WaterToAirHeatPump:EquationFit' object_type = object_type.upcase if object_type == 'Coil:Heating:WaterToAirHeatPump:EquationFit' object_type = 'Coil:Heating:GasMultiStage' if object_type == 'Coil:Heating:Gas:MultiStage' object_type = 'Coil:Heating:Fuel' if object_type == 'Coil:Heating:Gas' sql = self.sqlFile if sql.is_initialized sql = sql.get #SELECT * FROM ComponentSizes WHERE CompType = 'Coil:Heating:Gas' AND CompName = "COIL HEATING GAS 3" AND Description = "Design Size Nominal Capacity" query = "SELECT Value FROM ComponentSizes WHERE CompType='#{object_type}' AND CompName='#{name}' AND Description='#{value_name.strip}' AND Units='#{units}'" val = sql.execAndReturnFirstDouble(query) if val.is_initialized result = OpenStudio::OptionalDouble.new(val.get) else # @todo comment following line (debugging new HVACsizing objects right now) # OpenStudio::logFree(OpenStudio::Warn, "openstudio.model.Model", "QUERY ERROR: Data not found for query: #{query}") end else OpenStudio::logFree(OpenStudio::Error, 'openstudio.model.Model', 'Model has no sql file containing results, cannot lookup data.') end return result end # A helper method to get component sizes from the Equipment Summary of the TabularDataWithStrings Report # returns the autosized value as an optional double def getAutosizedValueFromEquipmentSummary(object, table_name, value_name, units) result = OpenStudio::OptionalDouble.new name = object.name.get.upcase sql = self.sqlFile if sql.is_initialized sql = sql.get #SELECT * FROM ComponentSizes WHERE CompType = 'Coil:Heating:Gas' AND CompName = "COIL HEATING GAS 3" AND Description = "Design Size Nominal Capacity" query = "Select Value FROM TabularDataWithStrings WHERE ReportName = 'EquipmentSummary' AND TableName = '#{table_name}' AND RowName = '#{name}' AND ColumnName = '#{value_name}' AND Units = '#{units}'" val = sql.execAndReturnFirstDouble(query) if val.is_initialized result = OpenStudio::OptionalDouble.new(val.get) else # @todo comment following line (debugging new HVACsizing objects right now) # OpenStudio::logFree(OpenStudio::Warn, "openstudio.model.Model", "QUERY ERROR: Data not found for query: #{query}") end else OpenStudio::logFree(OpenStudio::Error, 'openstudio.model.Model', 'Model has no sql file containing results, cannot lookup data.') end return result end # Helper function to output the fan power for each fan in the model # @param [String] csv_path: if given, will output a csv file # @return [Array of Hash] each row is a fan, with its name, type, rated watts per cfm, and the airloop or hvac component or zonehvac component it serves # @todo output actual bhp and allowable bhp for systems 3-4 and 5-8 # @todo remove maybe later? def output_fan_report(csv_path = nil) table = [] # Deal with all the constant volume fans self.getFanConstantVolumes.each do |fan| row = {:name=>fan.name.to_s, :type=>'Constant Volume', :rated_w_per_cfm=>fan.rated_w_per_cfm.round(2), :air_loop=>'', :hvac_component=>'', :zone_hvac_component=>''} if fan.airLoopHVAC.is_initialized row[:air_loop] = fan.airLoopHVAC.get.name.to_s elsif fan.containingHVACComponent.is_initialized row[:hvac_component] = fan.containingHVACComponent.get.name.to_s elsif fan.containingZoneHVACComponent.is_initialized row[:zone_hvac_component] = fan.containingZoneHVACComponent.get.name.to_s end # Add to table table << row end # Deal with all the constant volume fans self.getFanVariableVolumes.each do |fan| row = {:name=>fan.name.to_s, :type=>'Variable Volume', :rated_w_per_cfm=>fan.rated_w_per_cfm.round(2), :air_loop=>'', :hvac_component=>'', :zone_hvac_component=>''} if fan.airLoopHVAC.is_initialized row[:air_loop] = fan.airLoopHVAC.get.name.to_s elsif fan.containingHVACComponent.is_initialized row[:hvac_component] = fan.containingHVACComponent.get.name.to_s elsif fan.containingZoneHVACComponent.is_initialized row[:zone_hvac_component] = fan.containingZoneHVACComponent.get.name.to_s end # Add to table table << row end # Deal with all the constant volume fans self.getFanOnOffs.each do |fan| row = {:name=>fan.name.to_s, :type=>'On Off', :rated_w_per_cfm=>fan.rated_w_per_cfm.round(2), :air_loop=>'', :hvac_component=>'', :zone_hvac_component=>''} if fan.airLoopHVAC.is_initialized row[:air_loop] = fan.airLoopHVAC.get.name.to_s elsif fan.containingHVACComponent.is_initialized row[:hvac_component] = fan.containingHVACComponent.get.name.to_s elsif fan.containingZoneHVACComponent.is_initialized row[:zone_hvac_component] = fan.containingZoneHVACComponent.get.name.to_s end # Add to table table << row end # If a csv path is given, output if !csv_path.nil? && !table.first.nil? CSV.open(csv_path, "wb") do |csv| csv << table.first.keys # adds the attributes name on the first line table.each do |hash| csv << hash.values end end end return table end end