# frozen_string_literal: true

# *******************************************************************************
# OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC.
# All rights reserved.
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions are met:
#
# (1) Redistributions of source code must retain the above copyright notice,
# this list of conditions and the following disclaimer.
#
# (2) Redistributions in binary form must reproduce the above copyright notice,
# this list of conditions and the following disclaimer in the documentation
# and/or other materials provided with the distribution.
#
# (3) Neither the name of the copyright holder nor the names of any contributors
# may be used to endorse or promote products derived from this software without
# specific prior written permission from the respective party.
#
# (4) Other than as required in clauses (1) and (2), distributions in any form
# of modifications or other derivative works may not use the "OpenStudio"
# trademark, "OS", "os", or any other confusingly similar designation without
# specific prior written permission from Alliance for Sustainable Energy, LLC.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS
# "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
# THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE
# UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF
# THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
# EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT
# OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
# STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
# OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
# *******************************************************************************

# Start the measure
class CreateDEERPrototypeBuilding < OpenStudio::Measure::ModelMeasure
  require 'openstudio-standards'
  require_relative 'resources/deer_building_types'
  include DEERBuildingTypes

  # Define the name of the Measure.
  def name
    return 'Create DEER Prototype Building ALPHA Version'
  end

  # Human readable description
  def description
    return 'Creates the DEER Prototype Building Models as starting points for other analyses.  This measure is a work-in-progress ALPHA version.  Some of the building types do not simulate correctly, and no attempt has yet been made to ensure that the simulation results match the DOE-2 DEER Prototypes.'
  end

  # Human readable description of modeling approach
  def modeler_description
    return ''
  end

  # Define the arguments that the user will input.
  def arguments(model)
    args = OpenStudio::Measure::OSArgumentVector.new

    # Templates
    templates = [
      'DEER Pre-1975',
      'DEER 1985',
      'DEER 1996',
      'DEER 2003',
      'DEER 2007',
      'DEER 2011',
      'DEER 2014',
      'DEER 2015',
      'DEER 2017'
    ]

    # Climate Zones
    climate_zones = [
      'CEC T24-CEC1',
      'CEC T24-CEC2',
      'CEC T24-CEC3',
      'CEC T24-CEC4',
      'CEC T24-CEC5',
      'CEC T24-CEC6',
      'CEC T24-CEC7',
      'CEC T24-CEC8',
      'CEC T24-CEC9',
      'CEC T24-CEC10',
      'CEC T24-CEC11',
      'CEC T24-CEC12',
      'CEC T24-CEC13',
      'CEC T24-CEC14',
      'CEC T24-CEC15',
      'CEC T24-CEC16'
    ]

    # Make an argument for the building type/HVAC type combo
    building_hvac_chs = OpenStudio::StringVector.new
    building_type_to_hvac_systems.each do |bldg_abrev, hvac_abrevs|
      hvac_abrevs.each do |hvac_abrev|
        building_hvac_chs << "#{building_type_to_long[bldg_abrev]}: #{hvac_sys_to_long[hvac_abrev]}"
      end
    end
    building_hvac = OpenStudio::Measure::OSArgument.makeChoiceArgument('building_hvac', building_hvac_chs, true)
    building_hvac.setDisplayName('Building Type: HVAC Type')
    building_hvac.setDefaultValue('Assembly: Split or Packaged DX Unit with Gas Furnace')
    args << building_hvac

    # Make an argument for the template
    template_chs = OpenStudio::StringVector.new
    templates.each do |template|
      template_chs << template
    end
    template = OpenStudio::Measure::OSArgument.makeChoiceArgument('template', template_chs, true)
    template.setDisplayName('Template')
    template.setDefaultValue('DEER 1985')
    args << template

    # Make an argument for the climate zone
    climate_zone_chs = OpenStudio::StringVector.new
    climate_zones.each do |climate_zone|
      climate_zone_chs << climate_zone
    end
    climate_zone = OpenStudio::Measure::OSArgument.makeChoiceArgument('climate_zone', climate_zone_chs, true)
    climate_zone.setDisplayName('Climate Zone')
    climate_zone.setDefaultValue('CEC T24-CEC1')
    args << climate_zone

    return args
  end

  # Define what happens when the measure is run.
  def run(model, runner, user_arguments)
    super(model, runner, user_arguments)

    # Use the built-in error checking
    if !runner.validateUserArguments(arguments(model), user_arguments)
      return false
    end

    # Assign the user inputs to variables that can be accessed across the measure
    building_hvac = runner.getStringArgumentValue('building_hvac', user_arguments)
    template = runner.getStringArgumentValue('template', user_arguments)
    climate_zone = runner.getStringArgumentValue('climate_zone', user_arguments)

    # Split the Building type and HVAC type
    building_type_long = building_hvac.split(':')[0].strip
    hvac_sys_long = building_hvac.split(':')[1].strip

    # Get the building and HVAC type abbreviations used by the standards gem
    building_type = building_type_to_long.find { |k, v| v == building_type_long }.first
    hvac_sys = hvac_sys_to_long.find { |k, v| v == hvac_sys_long }.first

    # Turn debugging output on/off
    debug = false

    # Make a directory to save the resulting models for debugging
    run_dir = "#{Dir.pwd}/output"
    Dir.mkdir(run_dir) unless Dir.exist?(run_dir)

    # Make a prototype creator
    reset_log
    prototype_creator = Standard.build("#{template}_#{building_type}_#{hvac_sys}")
    prototype_creator.model_create_prototype_model(climate_zone, nil, run_dir, debug, model)

    log_messages_to_runner(runner, debug)
    reset_log

    return true
  end
end