class ZEAEDGMultifamily < ASHRAE901 # @!group elevators # Determines the percentage of the elevator cab lighting that is incandescent. # The remainder is assumed to be LED. # Defaults to 0% incandescent (100% LED), representing newer elevators. # # @param model [OpenStudio::Model::Model] OpenStudio model object # @return [Double] incandescent lighting percentage def model_elevator_lighting_pct_incandescent(model) pct_incandescent = 0.0 # 100% LED return pct_incandescent end # Determines the power of the elevator ventilation fan. # Same as 90.1-2013, which has a requirement for ventilation fan efficiency. # # @param model [OpenStudio::Model::Model] OpenStudio model object # @param vent_rate_cfm [Double] the ventilation rate in ft^3/min # @return [Double] the ventilation fan power in watts def model_elevator_fan_pwr(model, vent_rate_cfm) vent_pwr_per_flow_w_per_cfm = 0.33 vent_pwr_w = vent_pwr_per_flow_w_per_cfm * vent_rate_cfm # addendum 90.1-2007 aj has requirement on efficiency vent_pwr_w = vent_pwr_w * 0.29 / 0.70 return vent_pwr_w end end