# ******************************************************************************* # OpenStudio(R), Copyright (c) 2008-2020, Alliance for Sustainable Energy, LLC. # All rights reserved. # Redistribution and use in source and binary forms, with or without # modification, are permitted provided that the following conditions are met: # # (1) Redistributions of source code must retain the above copyright notice, # this list of conditions and the following disclaimer. # # (2) Redistributions in binary form must reproduce the above copyright notice, # this list of conditions and the following disclaimer in the documentation # and/or other materials provided with the distribution. # # (3) Neither the name of the copyright holder nor the names of any contributors # may be used to endorse or promote products derived from this software without # specific prior written permission from the respective party. # # (4) Other than as required in clauses (1) and (2), distributions in any form # of modifications or other derivative works may not use the "OpenStudio" # trademark, "OS", "os", or any other confusingly similar designation without # specific prior written permission from Alliance for Sustainable Energy, LLC. # # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, # THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE # UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF # THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, # EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT # OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, # STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY # OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. # ******************************************************************************* require 'openstudio' require 'openstudio/measure/ShowRunnerOutput' require 'fileutils' require_relative '../measure.rb' require 'minitest/autorun' class ModifyEnergyPlusFanVariableVolumeObjects_Test < Minitest::Test def test_ModifyEnergyPlusFanVariableVolumeObjects # create an instance of the measure measure = ModifyEnergyPlusFanVariableVolumeObjects.new # create an instance of a runner runner = OpenStudio::Measure::OSRunner.new(OpenStudio::WorkflowJSON.new) # load the test model translator = OpenStudio::OSVersion::VersionTranslator.new path = OpenStudio::Path.new(File.dirname(__FILE__) + '/Test.osm') model = translator.loadModel(path) assert(!model.empty?) model = model.get # forward translate OSM file to IDF file ft = OpenStudio::EnergyPlus::ForwardTranslator.new workspace = ft.translateModel(model) # get arguments and test that they are what we are expecting arguments = measure.arguments(workspace) # set argument values to good values and run the measure on the workspace argument_map = OpenStudio::Measure.convertOSArgumentVectorToMap(arguments) pressureRise = arguments[0].clone assert(pressureRise.setValue('0.9999')) argument_map['pressureRise'] = pressureRise maximumFlowRate = arguments[1].clone assert(maximumFlowRate.setValue('0.9999')) argument_map['maximumFlowRate'] = maximumFlowRate measure.run(workspace, runner, argument_map) result = runner.result show_output(result) assert(result.value.valueName == 'Success') assert(result.warnings.empty?) assert(result.info.size == 2) end def test_ModifyEnergyPlusFanVariableVolumeObjects_blankOptional # create an instance of the measure measure = ModifyEnergyPlusFanVariableVolumeObjects.new # create an instance of a runner runner = OpenStudio::Measure::OSRunner.new(OpenStudio::WorkflowJSON.new) # load the test model translator = OpenStudio::OSVersion::VersionTranslator.new path = OpenStudio::Path.new(File.dirname(__FILE__) + '/Test.osm') model = translator.loadModel(path) assert(!model.empty?) model = model.get # forward translate OSM file to IDF file ft = OpenStudio::EnergyPlus::ForwardTranslator.new workspace = ft.translateModel(model) # get arguments and test that they are what we are expecting arguments = measure.arguments(workspace) # set argument values to good values and run the measure on the workspace argument_map = OpenStudio::Measure.convertOSArgumentVectorToMap(arguments) # pressureRise = arguments[0].clone # assert(pressureRise.setValue("0.9999")) # argument_map["pressureRise"] = pressureRise maximumFlowRate = arguments[1].clone assert(maximumFlowRate.setValue('0.9999')) argument_map['maximumFlowRate'] = maximumFlowRate measure.run(workspace, runner, argument_map) result = runner.result show_output(result) assert(result.value.valueName == 'Success') assert(result.warnings.empty?) assert(result.info.size == 1) end end