class DOERefPre1980 < ASHRAE901
  # @!group Model

  # Apply the air leakage requirements to the model.
  # "For 'DOE Ref Pre-1980' and 'DOE Ref 1980-2004',
  # infiltration rates are not defined using this method,
  # no changes are actually made to the model.
  #
  # base infiltration rates off of.
  # @return [Bool] true if successful, false if not
  # @todo This infiltration method is not used by the Reference
  # buildings, fix this inconsistency.
  def model_apply_infiltration_standard(model)
    # Set the infiltration rate at each space
    model.getSpaces.sort.each do |space|
      space_apply_infiltration_rate(space)
    end

    return true
  end

  # Determine which climate zone to use.
  # For Pre-1980 and 1980-2004, use the most specific climate zone set.
  # For example, 2A and 2 both contain 2A, so use 2A.
  def model_get_climate_zone_set_from_list(model, possible_climate_zone_sets)
    climate_zone_set = possible_climate_zone_sets.sort.last
    return climate_zone_set
  end
end

Version data entries

16 entries across 16 versions & 1 rubygems

Version Path
openstudio-standards-0.2.10 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.10.rc3 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.10.rc2 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.10.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.9 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.8 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.7 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.6 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.5 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.4 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.3 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.2 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.0 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.0.rc2 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb
openstudio-standards-0.2.0.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_pre_1980/doe_ref_pre_1980.Model.rb