class NECB2011 def apply_standard_lights(set_lights: true, space_type:, space_type_properties:, lights_type:, lights_scale:) ##### Remove leading or trailing whitespace in case users add them in inputs if lights_scale.instance_of?(String) lights_scale = lights_scale.strip end if lights_type.nil? || lights_type == 'none' lights_type = 'NECB_Default' end if lights_scale.nil? || lights_scale == 'none' || lights_scale == 'NECB_Default' lights_scale = 1.0 end ##### Convert a string to a float if lights_scale.instance_of?(String) lights_scale = lights_scale.to_f end lights_have_info = false lighting_per_area = space_type_properties['lighting_per_area'].to_f lighting_per_person = space_type_properties['lighting_per_person'].to_f lights_frac_to_return_air = space_type_properties['lighting_fraction_to_return_air'].to_f lights_frac_radiant = space_type_properties['lighting_fraction_radiant'].to_f lights_frac_visible = space_type_properties['lighting_fraction_visible'].to_f lights_frac_replaceable = space_type_properties['lighting_fraction_replaceable'].to_f lights_have_info = true if !lighting_per_area.zero? or !lighting_per_person.zero? ##### NOTE: Reference for LED lighting's return air, radiant, and visible fraction values is: page 142, NREL (2014), "Proven Energy-Saving Technologies for Commercial Properties", available at https://www.nrel.gov/docs/fy15osti/63807.pdf if lights_type == 'LED' led_lights_have_info = false led_spacetype_data = @standards_data['tables']['led_lighting_data']['table'] standards_building_type = space_type.standardsBuildingType.is_initialized ? space_type.standardsBuildingType.get : nil standards_space_type = space_type.standardsSpaceType.is_initialized ? space_type.standardsSpaceType.get : nil led_space_type_properties = led_spacetype_data.detect { |s| (s['building_type'] == standards_building_type) && (s['space_type'] == standards_space_type) } if led_space_type_properties.nil? raise("#{standards_building_type} for #{standards_space_type} was not found please verify the led lighting database names match the space type names.") end lighting_per_area_led_lighting = led_space_type_properties['lighting_per_area'].to_f lights_frac_to_return_air_led_lighting = led_space_type_properties['lighting_fraction_to_return_air'].to_f lights_frac_radiant_led_lighting = led_space_type_properties['lighting_fraction_radiant'].to_f lights_frac_visible_led_lighting = led_space_type_properties['lighting_fraction_visible'].to_f led_lights_have_info = true unless lighting_per_area_led_lighting.zero? end if set_lights && lights_have_info # Remove all but the first instance instances = space_type.lights.sort if instances.size.zero? definition = OpenStudio::Model::LightsDefinition.new(space_type.model) if lights_type == 'NECB_Default' definition.setName("#{space_type.name} Lights Definition") elsif lights_type == 'LED' definition.setName("#{space_type.name} Lights Definition - LED lighting") end # puts definition.name().to_s instance = OpenStudio::Model::Lights.new(definition) instance.setName("#{space_type.name} Lights") # puts instance.name.to_s instance.setSpaceType(space_type) OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.SpaceType', "#{space_type.name} had no lights, one has been created.") instances << instance elsif instances.size > 1 instances.each_with_index do |inst, i| next if i.zero? OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.SpaceType', "Removed #{inst.name} from #{space_type.name}.") inst.remove end end # Modify the definition of the instance space_type.lights.sort.each do |inst| definition = inst.lightsDefinition unless lighting_per_area.zero? if lights_type == 'NECB_Default' set_lighting_per_area(space_type, definition, lighting_per_area) elsif lights_type == 'LED' set_lighting_per_area_led_lighting(space_type: space_type, definition: definition, lighting_per_area_led_lighting: lighting_per_area_led_lighting, lights_scale: lights_scale) end end unless lighting_per_person.zero? definition.setWattsperPerson(OpenStudio.convert(lighting_per_person.to_f, 'W/person', 'W/person').get) OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.SpaceType', "#{space_type.name} set lighting to #{lighting_per_person} W/person.") end unless lights_frac_to_return_air.zero? if lights_type == 'NECB_Default' definition.setReturnAirFraction(lights_frac_to_return_air) elsif lights_type == 'LED' definition.setReturnAirFraction(lights_frac_to_return_air_led_lighting) end end unless lights_frac_radiant.zero? if lights_type == 'NECB_Default' definition.setFractionRadiant(lights_frac_radiant) elsif lights_type == 'LED' definition.setFractionRadiant(lights_frac_radiant_led_lighting) end end unless lights_frac_visible.zero? if lights_type == 'NECB_Default' definition.setFractionVisible(lights_frac_visible) elsif lights_type == 'LED' definition.setFractionVisible(lights_frac_visible_led_lighting) end end # unless lights_frac_replaceable.zero? # definition.setFractionReplaceable(lights_frac_replaceable) # end end # If additional lights are specified, add those too additional_lighting_per_area = space_type_properties['additional_lighting_per_area'].to_f unless additional_lighting_per_area.zero? # Create the lighting definition additional_lights_def = OpenStudio::Model::LightsDefinition.new(space_type.model) additional_lights_def.setName("#{space_type.name} Additional Lights Definition") additional_lights_def.setWattsperSpaceFloorArea(OpenStudio.convert(additional_lighting_per_area.to_f, 'W/ft^2', 'W/m^2').get) additional_lights_def.setReturnAirFraction(lights_frac_to_return_air) additional_lights_def.setFractionRadiant(lights_frac_radiant) additional_lights_def.setFractionVisible(lights_frac_visible) # Create the lighting instance and hook it up to the space type additional_lights = OpenStudio::Model::Lights.new(additional_lights_def) additional_lights.setName("#{space_type.name} Additional Lights") additional_lights.setSpaceType(space_type) end end end def set_lighting_per_area(space_type, definition, lighting_per_area) occ_sens_lpd_frac = 1.0 # NECB2011 space types that require a reduction in the LPD to account for # the requirement of an occupancy sensor (8.4.4.6(3) and 4.2.2.2(2)) reduce_lpd_spaces = ['Classroom/lecture/training', 'Conf./meet./multi-purpose', 'Lounge/recreation', 'Conf./meet./multi-purpose', 'Washroom-sch-A', 'Washroom-sch-B', 'Washroom-sch-C', 'Washroom-sch-D', 'Washroom-sch-E', 'Washroom-sch-F', 'Washroom-sch-G', 'Washroom-sch-H', 'Washroom-sch-I', 'Dress./fitt. - performance arts', 'Locker room', 'Locker room-sch-A', 'Locker room-sch-B', 'Locker room-sch-C', 'Locker room-sch-D', 'Locker room-sch-E', 'Locker room-sch-F', 'Locker room-sch-G', 'Locker room-sch-H', 'Locker room-sch-I', 'Retail - dressing/fitting'] if reduce_lpd_spaces.include?(space_type.standardsSpaceType.get) # Note that "Storage area", "Storage area - refrigerated", "Hospital - medical supply" and "Office - enclosed" # LPD should only be reduced if their space areas are less than specific area values. # This is checked in a space loop after this function in the calling routine. occ_sens_lpd_frac = 0.9 end definition.setWattsperSpaceFloorArea(OpenStudio.convert(lighting_per_area.to_f * occ_sens_lpd_frac, 'W/ft^2', 'W/m^2').get) OpenStudio.logFree(OpenStudio::Info, 'openstudio.standards.SpaceType', "#{space_type.name} set LPD to #{lighting_per_area} W/ft^2.") end end