AddHpwh
Add HPWH for Domestic Hot Water
This measure adds or replaces existing domestic hot water heater with air source heat pump system and allows for the addition of multiple daily flexible control time windows. The heater/tank system may charge at maximum capacity up to an elevated temperature, or float without any heat addition for a specified timeframe down to a minimum tank temperature.
This measure allows selection between three heat pump water heater modeling approaches in EnergyPlus.The user may select between the pumped-condenser or wrapped-condenser objects. They may also elect to use a simplified calculation which does not use the heat pump objects, but instead used an electric resistance heater and approximates the equivalent electrical input that would be required from a heat pump. This expedites simulation at the expense of accuracy.
The flexibility of the system is based on user-defined temperatures and times, which are converted into schedule objects. There are four flexibility options. (1) None: normal operation of the DHW system at a fixed tank temperature setpoint. (2) Charge - Heat Pump: the tank is charged to a maximum temperature using only the heat pump. (3) Charge - Electric: the tank is charged using internal electric resistance heaters to a maximum temperature. (4) Float: all heating elements are turned-off for a user-defined time period unless the tank temperature falls below a minimum value. The heat pump will be prioritized in a low tank temperature event, with the electric resistance heaters serving as back-up.
Due to the heat pump interaction with zone conditioning as well as tank heating, users may experience simulation errors if the heat pump is too large and placed in an already conditioned zoned. Try using multiple smaller units, modifying the heat pump location within the model, or adjusting the zone thermostat constraints. Use mulitiple instances of the measure to add multiple heat pump water heaters.
remove_wh
Remove existing water heater?
Boolean
true
false
true
true
true
false
false
wh
Select 40+ gallon water heater to replace or augment
All can only be used with the 'Simplified' model
Choice
true
false
All Water Heaters (Simplified Only)
All Water Heaters (Simplified Only)
All Water Heaters (Simplified Only)
vol
Set hot water tank volume [gal]
Enter 0 to use existing tank volume(s). Values less than 5 are treated as sizing multipliers.
Double
gal
false
false
0
type
Select heat pump water heater type
Choice
true
false
Simplified
Simplified
Simplified
PumpedCondenser
PumpedCondenser
WrappedCondenser
WrappedCondenser
zone_name
Select thermal zone for HP evaporator
Does not apply to 'Simplified' cases
Choice
true
false
N/A - Simplified
N/A - Simplified
N/A - Simplified
Error: No Thermal Zones Found
Error: No Thermal Zones Found
cap
Set heat pump heating capacity
[kW]
Double
true
false
23.4
cop
Set heat pump rated COP (heating)
Double
true
false
3.2
bu_cap
Set electric backup heating capacity
[kW]
Double
true
false
23.4
max_temp
Set maximum tank temperature
[F]
Double
true
false
160
min_temp
Set minimum tank temperature during float
[F]
Double
true
false
120
db_temp
Set deadband temperature difference between heat pump and electric backup
[F]
Double
true
false
5
sched
Select reference tank setpoint temperature schedule
Choice
true
false
Use Existing Setpoint Schedule
Use Existing Setpoint Schedule
Use Existing Setpoint Schedule
--Create New @ 140F--
--Create New @ 140F--
flex0
Daily Flex Period 1:
Applies every day in the full run period.
Choice
true
false
None
None
None
Charge - Heat Pump
Charge - Heat Pump
Charge - Electric
Charge - Electric
Float
Float
flex_hrs0
Use 24-Hour Format
String
false
false
HH:MM - HH:MM
flex1
Daily Flex Period 2:
Applies every day in the full run period.
Choice
true
false
None
None
None
Charge - Heat Pump
Charge - Heat Pump
Charge - Electric
Charge - Electric
Float
Float
flex_hrs1
Use 24-Hour Format
String
false
false
HH:MM - HH:MM
flex2
Daily Flex Period 3:
Applies every day in the full run period.
Choice
true
false
None
None
None
Charge - Heat Pump
Charge - Heat Pump
Charge - Electric
Charge - Electric
Float
Float
flex_hrs2
Use 24-Hour Format
String
false
false
HH:MM - HH:MM
flex3
Daily Flex Period 4:
Applies every day in the full run period.
Choice
true
false
None
None
None
Charge - Heat Pump
Charge - Heat Pump
Charge - Electric
Charge - Electric
Float
Float
flex_hrs3
Use 24-Hour Format
String
false
false
HH:MM - HH:MM
Service Water Heating.Water Heating
Measure Type
ModelMeasure
string
Intended Software Tool
Apply Measure Now
string
Intended Software Tool
OpenStudio Application
string
Intended Software Tool
Parametric Analysis Tool
string
Intended Use Case
Model Articulation
string
Intended Use Case
New Construction EE
string
Intended Use Case
Retrofit EE
string
README.md.erb
erb
readmeerb
703C9964
LICENSE.md
md
license
E0468DD6
Flexible Domestic Hot Water Implementation Guide.pdf
pdf
doc
F610A0B3
SmallHotel-2A.osm
osm
test
21334FFF
OpenStudio
3.0.0
2.8.0
measure.rb
rb
script
8D508D19
add_hpwh_test.rb
rb
test
72BCB712
CZ06RV2.epw
epw
test
52282D70
README.md
md
readme
C5978CDF