3.1
coil_cooling_water_multiplier
0fb42580-a644-4291-9a08-05521a6e7940
0891c8f9-60bf-42f2-a9de-1dd90224bfb0
2024-11-16T23:44:49Z
8CBDDA1B
CoilCoolingWaterMultiplier
Cooling Coils Water Multiplier
This is a general purpose measure to calibrate Water Cooling Coils with a Multiplier.
It will be used for calibration of inlet water temperatures, inlet and outlet air temperatures and design flowrates. User can choose between a SINGLE coil or ALL the Coils.
coil
Apply the Measure to a SINGLE Water Cooling Coil, ALL the Water Cooling Coils or NONE.
Choice
true
false
{361898b3-4c80-4f20-bff4-296675ed448d}
{361898b3-4c80-4f20-bff4-296675ed448d}
*All Water Cooling Coils*
0
*None*
design_water_flow_rate
Multiplier for Design Water Flow Rate.
Multiplier for Design Water Flow Rate.
Double
true
false
1
design_air_flow_rate
Multiplier for Design Air Flow Rate.
Multiplier for Design Air Flow Rate.
Double
true
false
1
design_inlet_water_temperature
Multiplier for Inlet Water Temperature.
Multiplier for Inlet Water Temperature.
Double
true
false
1
design_inlet_air_temperature
Multiplier for Inlet Air Temperature.
Multiplier for Inlet Air Temperature.
Double
true
false
1
design_outlet_air_temperature
Multiplier for Outlet Air Temperature.
Multiplier for Outlet Air Temperature.
Double
true
false
1
design_inlet_air_humidity_ratio
Multiplier for Inlet Air Humidity Ratio.
Multiplier for Inlet Air Humidity Ratio.
Double
true
false
1
HVAC.Cooling
Measure Type
ModelMeasure
string
LICENSE.md
md
license
8696A072
README.md
md
readme
3C509F3A
README.md.erb
erb
readmeerb
703C9964
OpenStudio
2.1.0
2.1.0
measure.rb
rb
script
D4395EC8