<?xml version="1.0" encoding="UTF-8"?> <Reports xmlns="https://epbr.digital.communities.gov.uk/xsd/cepc" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="https://epbr.digital.communities.gov.uk/xsd/cepc ../CEPC-7.1/Reports/CEPC-Reports.xsd" > <Report> <Report-Header> <RRN>0000-0000-0000-0000-0000</RRN> <Issue-Date>2020-05-14</Issue-Date> <Report-Type>1</Report-Type> <Valid-Until>2026-05-04</Valid-Until> <Related-RRN>4192-1535-8427-8844-6702</Related-RRN> <Inspection-Date>2020-05-04</Inspection-Date> <Registration-Date>2020-05-04</Registration-Date> <Status>entered</Status> <Language-Code>1</Language-Code> <Energy-Assessor> <Certificate-Number>SPEC000000</Certificate-Number> <Name>Name1</Name> <Accreditation-Scheme-Name>Information not available</Accreditation-Scheme-Name> <Accreditation-Scheme-Website>Information not available</Accreditation-Scheme-Website> <Trading-Address>123 My Street, My City, AB3 4CD</Trading-Address> <Company-Name>Joe Bloggs Ltd</Company-Name> <Qualifications>NOS5</Qualifications> <Status>Registered</Status> </Energy-Assessor> <Building-Complexity>Level 3</Building-Complexity> <Property-Details> <UPRN>UPRN-000000000001</UPRN> <Property-Address> <Address-Line-1>2 Lonely Street</Address-Line-1> <Post-Town>Post-Town1</Post-Town> <Postcode>A0 0AA</Postcode> </Property-Address> <Property-Type>B1 Offices and Workshop businesses</Property-Type> <Is-Heritage-Site>N</Is-Heritage-Site> </Property-Details> <Calculation-Details> <Calculation-Tool>DCLG, ORCalc, v3.6.3</Calculation-Tool> </Calculation-Details> </Report-Header> <Summary-Of-Performance> <Building-Data> <Analysis-Type>ACTUAL</Analysis-Type> <Area>402.6</Area> <Area-Exterior>1058.32</Area-Exterior> <Weather>LON</Weather> <Q50-Infiltration>10</Q50-Infiltration> <Building-W-K>411.86</Building-W-K> <Building-W-M2K>0.389164</Building-W-M2K> <Building-Alpha>18.3412</Building-Alpha> <Activities> <Activity> <ID>1005</ID> <Area>402.6</Area> </Activity> </Activities> <Global-Performance> <KWH-M2-Heating>41.0355</KWH-M2-Heating> <KWH-M2-Cooling>25.3865</KWH-M2-Cooling> <KWH-M2-Auxiliary>39.0832</KWH-M2-Auxiliary> <KWH-M2-Lighting>54.0787</KWH-M2-Lighting> <KWH-M2-DHW>2.77834</KWH-M2-DHW> <KWH-M2-Equipment>42.185</KWH-M2-Equipment> <KWH-M2-Natural-Gas>41.0355</KWH-M2-Natural-Gas> <KWH-M2-LPG>0</KWH-M2-LPG> <KWH-M2-Biogas>0</KWH-M2-Biogas> <KWH-M2-Oil>0</KWH-M2-Oil> <KWH-M2-Coal>0</KWH-M2-Coal> <KWH-M2-Anthracite>0</KWH-M2-Anthracite> <KWH-M2-Smokeless>0</KWH-M2-Smokeless> <KWH-M2-Dual-Fuel>0</KWH-M2-Dual-Fuel> <KWH-M2-Biomass>0</KWH-M2-Biomass> <KWH-M2-Supplied>121.327</KWH-M2-Supplied> <KWH-M2-Waste-Heat>0</KWH-M2-Waste-Heat> <KWH-M2-District-Heating>0</KWH-M2-District-Heating> <KWH-M2-Displaced>6.10442</KWH-M2-Displaced> <KWH-M2-PVS>3.07665</KWH-M2-PVS> <KWH-M2-Wind>3.02777</KWH-M2-Wind> <KWH-M2-CHP>0</KWH-M2-CHP> <KWH-M2-SES>0.801605</KWH-M2-SES> </Global-Performance> <HVAC-Systems> <HVAC-System-Data> <Area>402.6</Area> <Type>Fan coil systems</Type> <Heat-Source>LTHW boiler</Heat-Source> <Fuel-Type>Natural Gas</Fuel-Type> <MJ-M2-Heating-Dem>122.171</MJ-M2-Heating-Dem> <MJ-M2-Cooling-Dem>179.401</MJ-M2-Cooling-Dem> <KWH-M2-Heating>41.0355</KWH-M2-Heating> <KWH-M2-Cooling>25.3865</KWH-M2-Cooling> <KWH-M2-Auxiliary>39.0832</KWH-M2-Auxiliary> <Heating-SSEFF>0.827</Heating-SSEFF> <Cooling-SSEER>1.963</Cooling-SSEER> <Heating-Gen-SEFF>0.89</Heating-Gen-SEFF> <Cooling-Gen-SEER>2.5</Cooling-Gen-SEER> <Activities> <Activity> <ID>1005</ID> <Area>402.6</Area> </Activity> </Activities> </HVAC-System-Data> </HVAC-Systems> </Building-Data> <Building-Data> <Analysis-Type>NOTIONAL</Analysis-Type> <Area>402.6</Area> <Area-Exterior>1058.32</Area-Exterior> <Weather>LON</Weather> <Q50-Infiltration>3</Q50-Infiltration> <Building-W-K>362.524</Building-W-K> <Building-W-M2K>0.342547</Building-W-M2K> <Building-Alpha>11.2489</Building-Alpha> <Activities> <Activity> <ID>1005</ID> <Area>402.6</Area> </Activity> </Activities> <Global-Performance> <KWH-M2-Heating>18.1582</KWH-M2-Heating> <KWH-M2-Cooling>7.46769</KWH-M2-Cooling> <KWH-M2-Auxiliary>14.0716</KWH-M2-Auxiliary> <KWH-M2-Lighting>14.4489</KWH-M2-Lighting> <KWH-M2-DHW>3.33761</KWH-M2-DHW> <KWH-M2-Equipment>42.185</KWH-M2-Equipment> <KWH-M2-Natural-Gas>18.1582</KWH-M2-Natural-Gas> <KWH-M2-LPG>0</KWH-M2-LPG> <KWH-M2-Biogas>0</KWH-M2-Biogas> <KWH-M2-Oil>3.33761</KWH-M2-Oil> <KWH-M2-Coal>0</KWH-M2-Coal> <KWH-M2-Anthracite>0</KWH-M2-Anthracite> <KWH-M2-Smokeless>0</KWH-M2-Smokeless> <KWH-M2-Dual-Fuel>0</KWH-M2-Dual-Fuel> <KWH-M2-Biomass>0</KWH-M2-Biomass> <KWH-M2-Supplied>35.9883</KWH-M2-Supplied> <KWH-M2-Waste-Heat>0</KWH-M2-Waste-Heat> <KWH-M2-District-Heating>0</KWH-M2-District-Heating> <KWH-M2-Displaced>0</KWH-M2-Displaced> <KWH-M2-PVS>0</KWH-M2-PVS> <KWH-M2-Wind>0</KWH-M2-Wind> <KWH-M2-CHP>0</KWH-M2-CHP> <KWH-M2-SES>0</KWH-M2-SES> </Global-Performance> <HVAC-Systems> <HVAC-System-Data> <Area>402.6</Area> <Type>Fan coil systems</Type> <Heat-Source>LTHW boiler</Heat-Source> <Fuel-Type>Natural Gas</Fuel-Type> <MJ-M2-Heating-Dem>53.5375</MJ-M2-Heating-Dem> <MJ-M2-Cooling-Dem>96.7814</MJ-M2-Cooling-Dem> <KWH-M2-Heating>18.1581</KWH-M2-Heating> <KWH-M2-Cooling>7.46769</KWH-M2-Cooling> <KWH-M2-Auxiliary>14.0716</KWH-M2-Auxiliary> <Heating-SSEFF>0.819</Heating-SSEFF> <Cooling-SSEER>3.6</Cooling-SSEER> <Heating-Gen-SEFF>0</Heating-Gen-SEFF> <Cooling-Gen-SEER>0</Cooling-Gen-SEER> <Activities> <Activity> <ID>1005</ID> <Area>402.6</Area> </Activity> </Activities> </HVAC-System-Data> </HVAC-Systems> </Building-Data> <Building-Data> <Analysis-Type>REFERENCE</Analysis-Type> <Area>402.6</Area> <Area-Exterior>1058.32</Area-Exterior> <Weather>LON</Weather> <Q50-Infiltration>10</Q50-Infiltration> <Building-W-K>718.761</Building-W-K> <Building-W-M2K>0.679153</Building-W-M2K> <Building-Alpha>10</Building-Alpha> <Activities> <Activity> <ID>1005</ID> <Area>402.6</Area> </Activity> </Activities> <Global-Performance> <KWH-M2-Heating>71.9516</KWH-M2-Heating> <KWH-M2-Cooling>25.6538</KWH-M2-Cooling> <KWH-M2-Auxiliary>2.16062</KWH-M2-Auxiliary> <KWH-M2-Lighting>45.54</KWH-M2-Lighting> <KWH-M2-DHW>6.41192</KWH-M2-DHW> <KWH-M2-Equipment>42.185</KWH-M2-Equipment> <KWH-M2-Natural-Gas>78.3634</KWH-M2-Natural-Gas> <KWH-M2-LPG>0</KWH-M2-LPG> <KWH-M2-Biogas>0</KWH-M2-Biogas> <KWH-M2-Oil>0</KWH-M2-Oil> <KWH-M2-Coal>0</KWH-M2-Coal> <KWH-M2-Anthracite>0</KWH-M2-Anthracite> <KWH-M2-Smokeless>0</KWH-M2-Smokeless> <KWH-M2-Dual-Fuel>0</KWH-M2-Dual-Fuel> <KWH-M2-Biomass>0</KWH-M2-Biomass> <KWH-M2-Supplied>73.3544</KWH-M2-Supplied> <KWH-M2-Waste-Heat>0</KWH-M2-Waste-Heat> <KWH-M2-District-Heating>0</KWH-M2-District-Heating> <KWH-M2-Displaced>0</KWH-M2-Displaced> <KWH-M2-PVS>0</KWH-M2-PVS> <KWH-M2-Wind>0</KWH-M2-Wind> <KWH-M2-CHP>0</KWH-M2-CHP> <KWH-M2-SES>0</KWH-M2-SES> </Global-Performance> <HVAC-Systems> <HVAC-System-Data> <Area>402.6</Area> <Type>Fan coil systems</Type> <Heat-Source>LTHW boiler</Heat-Source> <Fuel-Type>Natural Gas</Fuel-Type> <MJ-M2-Heating-Dem>189.088</MJ-M2-Heating-Dem> <MJ-M2-Cooling-Dem>207.795</MJ-M2-Cooling-Dem> <KWH-M2-Heating>71.9516</KWH-M2-Heating> <KWH-M2-Cooling>25.6538</KWH-M2-Cooling> <KWH-M2-Auxiliary>2.16062</KWH-M2-Auxiliary> <Heating-SSEFF>0.73</Heating-SSEFF> <Cooling-SSEER>2.25</Cooling-SSEER> <Heating-Gen-SEFF>0</Heating-Gen-SEFF> <Cooling-Gen-SEER>0</Cooling-Gen-SEER> <Activities> <Activity> <ID>1005</ID> <Area>402.6</Area> </Activity> </Activities> </HVAC-System-Data> </HVAC-Systems> </Building-Data> </Summary-Of-Performance> <OR-Operational-Rating> <OR-Assessment-Start-Date>2020-05-01</OR-Assessment-Start-Date> <OR-Assessment-End-Date>2020-05-01</OR-Assessment-End-Date> <Building-Category></Building-Category> <OR-Building-Data> <HVAC-System></HVAC-System> <Internal-Environment></Internal-Environment> <Assessment-Period-Alignment></Assessment-Period-Alignment> </OR-Building-Data> <OR-Usable-Floor-Area></OR-Usable-Floor-Area> <OR-Previous-Data></OR-Previous-Data> <OR-Benchmark-Data> <Main-Benchmark></Main-Benchmark> <Benchmarks> <Benchmark> <Area-Metric></Area-Metric> <Benchmark></Benchmark> <Benchmark-ID>45</Benchmark-ID> <Floor-Area>15</Floor-Area> <Name></Name> <Special-Uses-Area></Special-Uses-Area> <TUFA></TUFA> </Benchmark> </Benchmarks> </OR-Benchmark-Data> <OR-Energy-Consumption></OR-Energy-Consumption> </OR-Operational-Rating> <Insurance-Details> <Insurer>Insurance</Insurer> <Policy-No>0001</Policy-No> <Effective-Date>2020-08-01</Effective-Date> <Expiry-Date>2021-07-31</Expiry-Date> <PI-Limit>500000</PI-Limit> </Insurance-Details> <Display-Certificate> <DEC-Status>1</DEC-Status> <Reason-Type>6</Reason-Type> <DEC-Related-Party-Disclosure>4</DEC-Related-Party-Disclosure> <DEC-Annual-Energy-Summary> <Annual-Energy-Use-Fuel-Thermal>1</Annual-Energy-Use-Fuel-Thermal> <Annual-Energy-Use-Electrical>1</Annual-Energy-Use-Electrical> <Renewables-Fuel-Thermal>1</Renewables-Fuel-Thermal> <Renewables-Electrical>1</Renewables-Electrical> <Typical-Thermal-Use>1</Typical-Thermal-Use> <Typical-Electrical-Use>1</Typical-Electrical-Use> </DEC-Annual-Energy-Summary> <Technical-Information> <Building-Environment>Heating and Natural Ventilation</Building-Environment> <Floor-Area>99</Floor-Area> </Technical-Information> <AC-Questionnaire> <AC-Present>Yes</AC-Present> <AC-Rated-Output> <AC-kW-Rating>1</AC-kW-Rating> </AC-Rated-Output> <AC-Inspection-Commissioned>1</AC-Inspection-Commissioned> </AC-Questionnaire> <This-Assessment> <Nominated-Date>2020-01-01</Nominated-Date> <Energy-Rating>1</Energy-Rating> <Electricity-CO2>7</Electricity-CO2> <Heating-CO2>3</Heating-CO2> <Renewables-CO2>0</Renewables-CO2> </This-Assessment> <Year1-Assessment> <Nominated-Date>2019-01-01</Nominated-Date> <Energy-Rating>24</Energy-Rating> <Electricity-CO2>10</Electricity-CO2> <Heating-CO2>5</Heating-CO2> <Renewables-CO2>1</Renewables-CO2> </Year1-Assessment> <Year2-Assessment> <Nominated-Date>2018-01-01</Nominated-Date> <Energy-Rating>40</Energy-Rating> <Electricity-CO2>15</Electricity-CO2> <Heating-CO2>10</Heating-CO2> <Renewables-CO2>2</Renewables-CO2> </Year2-Assessment> </Display-Certificate> </Report> </Reports>