Sha256: a88e6988fbc00137031b2e719bb809b610aa621ef4bbc8f9418f7d5caa2c8427
Contents?: true
Size: 938 Bytes
Versions: 32
Compression:
Stored size: 938 Bytes
Contents
# Reopen the OpenStudio class to add methods to apply standards to this object class OpenStudio::Model::AirLoopHVAC # Sets all auto-sizeable fields to autosize def autosize self.autosizeDesignSupplyAirFlowRate end # Takes the values calculated by the EnergyPlus sizing routines # and puts them into this object model in place of the autosized fields. # Must have previously completed a run with sql output for this to work. def applySizingValues design_supply_air_flow_rate = self.autosizedDesignSupplyAirFlowRate if design_supply_air_flow_rate.is_initialized self.setDesignSupplyAirFlowRate(design_supply_air_flow_rate.get) end end # returns the autosized design supply air flow rate as an optional double def autosizedDesignSupplyAirFlowRate return self.model.getAutosizedValue(self, 'Design Supply Air Flow Rate', 'm3/s') end end