3.1 generic_qaqc d58d6b29-69ba-4915-b907-3c2c37ddb7c7 30314b23-6e89-4672-ae78-4be112a7e2b4 2024-07-11T14:32:09Z 0A3BF61C GenericQAQC Generic QAQC This measure extracts key simulation results and performs basic model QAQC checks. Each category of checks provides a description of the source of the check. In some cases the target standards and tollerances are adjustable. Reads the model and sql file to pull out the necessary information and run the model checks. The check results show up as warning messages in the measure's output on the PAT run tab. template Target ASHRAE Standard This used to set the target standard for most checks. Choice true false 90.1-2013 DOE Ref Pre-1980 DOE Ref Pre-1980 DOE Ref 1980-2004 DOE Ref 1980-2004 90.1-2004 90.1-2004 90.1-2007 90.1-2007 90.1-2010 90.1-2010 90.1-2013 90.1-2013 90.1-2016 90.1-2016 90.1-2019 90.1-2019 ComStock DOE Ref Pre-1980 ComStock DOE Ref Pre-1980 ComStock DOE Ref 1980-2004 ComStock DOE Ref 1980-2004 ComStock 90.1-2004 ComStock 90.1-2004 ComStock 90.1-2007 ComStock 90.1-2007 ComStock 90.1-2010 ComStock 90.1-2010 ComStock 90.1-2013 ComStock 90.1-2013 ComStock 90.1-2016 ComStock 90.1-2016 ComStock 90.1-2019 ComStock 90.1-2019 check_eui_reasonableness EUI Reasonableness (General) Check model EUI against selected ASHRAE standard DOE prototype building. Boolean true false true true true false false check_eui_reasonableness_tol EUI Reasonableness Tolerance Double fraction true false 0.1 check_eui_by_end_use End Use by Category (General) Check model consumption by end use against selected ASHRAE standard DOE prototype building. Boolean true false true true true false false check_eui_by_end_use_tol End Use by Category Tolerance Double fraction true false 0.25 check_mech_sys_part_load_eff Mechanical System Part Load Efficiency (General) Check 40% and 80% part load efficency against selected ASHRAE standard for the following compenent types: ChillerElectricEIR, CoilCoolingDXSingleSpeed, CoilCoolingDXTwoSpeed, CoilHeatingDXSingleSpeed. Checking EIR Function of Part Load Ratio curve for chiller and EIR Function of Flow Fraction for DX coils. Boolean true false true true true false false check_mech_sys_part_load_eff_tol Mechanical System Part Load Efficiency Tolerance Double fraction true false 0.05 check_mech_sys_capacity Mechanical System Capacity (General) Check HVAC capacity against ASHRAE rules of thumb for chiller max flow rate, air loop max flow rate, air loop cooling capciaty, and zone heating capcaity. Zone heating check will skip thermal zones without any exterior exposure, and thermal zones that are not conditioned. Boolean true false true true true false false check_simultaneous_heating_and_cooling Simultaneous Heating and Cooling (General) Check for simultaneous heating and cooling by looping through all Single Duct VAV Reheat Air Terminals and analyzing hourly data when there is a cooling load. Boolean true false true true true false false check_simultaneous_heating_and_cooling_max_tol Simultaneous Heating and Cooling Max Tolerance Double fraction true false 0.05 check_internal_loads Internal Loads (Baseline) Check LPD, ventilation rates, occupant density, plug loads, and equipment loads against selected ASHRAE standard DOE Prototype buildings. Boolean true false true true true false false check_internal_loads_tol Internal Loads Tolerance Double fraction true false 0.1 check_schedules Schedules (Baseline) Check schedules for lighting, ventilation, occupant density, plug loads, and equipment based on DOE reference building schedules in terms of full load hours per year. Boolean true false true true true false false check_schedules_tol Schedules Tolerance Double fraction true false 0.05 check_envelope_conductance Envelope R-Value (Baseline) Check envelope against selected ASHRAE standard. Roof reflectance of 55%, wall relfectance of 30%. Boolean true false true true true false false check_envelope_conductance_tol Envelope R-Value Tolerance Double fraction true false 0.1 check_domestic_hot_water Domestic Hot Water (Baseline) Check against the 2011 ASHRAE Handbook - HVAC Applications, Table 7 section 50.14. Boolean true false true true true false false check_domestic_hot_water_tol Domestic Hot Water Tolerance Double fraction true false 0.25 check_mech_sys_efficiency Mechanical System Efficiency (Baseline) Check against selected ASHRAE standard for the following component types: ChillerElectricEIR, CoilCoolingDXSingleSpeed, CoilCoolingDXTwoSpeed, CoilHeatingDXSingleSpeed, BoilerHotWater, FanConstantVolume, FanVariableVolume, PumpConstantSpeed, PumpVariableSpeed. Boolean true false true true true false false check_mech_sys_efficiency_tol Mechanical System Efficiency Tolerance Double fraction true false 0.1 check_mech_sys_type Baseline Mechanical System Type (Baseline) Check against ASHRAE 90.1. Infers the baseline system type based on the equipment serving the zone and their heating/cooling fuels. Only does a high-level inference; does not look for the presence/absence of required controls, etc. Boolean true false true true true false false check_supply_air_and_thermostat_temp_difference Supply and Zone Air Temperature (Baseline) Check if fans modeled to ASHRAE 90.1 2013 Section G3.1.2.9 requirements. Compare the supply air temperature for each thermal zone against the thermostat setpoints. Throw flag if temperature difference excedes threshold of 20.0F plus the selected tolerance. Boolean true false true true true false false check_supply_air_and_thermostat_temp_difference_tol Supply and Zone Air Temperature Tolerance Double F true false 0.5 use_upstream_args Use Upstream Argument Values When true this will look for arguments or registerValues in upstream measures that match arguments from this measure, and will use the value from the upstream measure in place of what is entered for this measure. Boolean true false true true true false false Reporting.QAQC Uses SketchUp API false boolean Intended Software Tool OpenStudio Application string Intended Software Tool Parametric Analysis Tool string Intended Use Case Automatic Report Generation string Measure Type ReportingMeasure string Intended Software Tool OpenStudio Application string Intended Software Tool Parametric Analysis Tool string Intended Use Case Automatic Report Generation string LICENSE.md md license BFFB1AA6 README.md md readme 11DDEADA README.md.erb erb readmeerb 3AFCE991 generic_qaqc_detailed.jpg jpg doc 92EA3F5C generic_qaqc_summary.jpg jpg doc 45ABEE68 OpenStudio 2.0.0 3.8.0 measure.rb rb script C631FD2F check_air_sys_temps.rb rb resource 3B5F8121 check_calibration.rb rb resource B48E6C72 check_cond_zns.rb rb resource DE81D202 check_domestic_hot_water.rb rb resource 29505A2B check_envelope_conductance.rb rb resource 192010AD check_eui_by_end_use.rb rb resource 0C3C90F2 check_eui_reasonableness.rb rb resource 60A5A2E7 check_fan_pwr.rb rb resource F915B4D9 check_internal_loads.rb rb resource 874EBD06 check_mech_sys_capacity.rb rb resource 591AC54A check_mech_sys_efficiency.rb rb resource E470E5E3 check_mech_sys_part_load_eff.rb rb resource B6AC9F08 check_mech_sys_type.rb rb resource 2CE1AFFF check_part_loads.rb rb resource D8F94023 check_placeholder.rb rb resource 3E6519F2 check_plant_cap.rb rb resource 68CC52D1 check_plant_temps.rb rb resource B171C6AE check_plenum_loads.rb rb resource 79CF25A9 check_pump_pwr.rb rb resource D20D7BDE check_sch_coord.rb rb resource 113F1F3E check_schedules.rb rb resource 47BA3DD4 check_simultaneous_heating_and_cooling.rb rb resource 5F60FA03 check_supply_air_and_thermostat_temp_difference.rb rb resource 824F4D82 check_weather_files.rb rb resource 32981307 design_doc.txt txt resource 779C47A4 os_lib_reporting_qaqc.rb rb resource 1A922BAF report.html.erb erb resource FF1CBF19 0422_test_b_sm_off.osm osm test E797C12A BasicOfficeTest.osm osm test 75942985 BasicOfficeTest_Mabry.osm osm test 601A4415 BasicOfficeTest_Mueller.osm osm test C57E800F BasicOfficeTest_Mueller_altHVAC_a.osm osm test 2B03A487 BasicOfficeTest_Mueller_altHVAC_b.osm osm test F12AB925 MidRiseApt.osm osm test 8316418F USA_CO_Golden-NREL.724666_TMY3.epw epw test BDF687C1 USA_NY_Buffalo-Greater.Buffalo.Intl.AP.725280_TMY3.epw epw test 6B50E0FF USA_TX_Austin-Camp.Mabry.722544_TMY3.epw epw test FB60E24C USA_TX_Austin-Mueller.Muni.AP.722540_TMY3.epw epw test B5BB1762 fsr.osm osm test D2A4E538 measure_Test.rb rb test 33870D5A uo_blend.osm osm test 605CDF17 uo_lg_hotel.osm osm test B8033381 uo_mixed.osm osm test 1874C555 uo_strip_mall.osm osm test 95EBB09E