{ "tables": { "unitary_acs": { "data_type": "table", "refs": [ "assumption" ], "table": [ { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Single Package", "minimum_capacity": 0, "maximum_capacity": 65000.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": 14.0, "minimum_energy_efficiency_ratio": null, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Single Package", "minimum_capacity": 0, "maximum_capacity": 65000.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": 14.0, "minimum_energy_efficiency_ratio": null, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Split System", "minimum_capacity": 0, "maximum_capacity": 65000.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": 15.0, "minimum_energy_efficiency_ratio": null, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Split System", "minimum_capacity": 0, "maximum_capacity": 65000.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": 15.0, "minimum_energy_efficiency_ratio": null, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Single Package", "minimum_capacity": 65001.0, "maximum_capacity": 136480.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 9.44, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Single Package", "minimum_capacity": 65001.0, "maximum_capacity": 136480.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 9.26, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Split System", "minimum_capacity": 65001.0, "maximum_capacity": 136480.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 9.44, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Split System", "minimum_capacity": 65001.0, "maximum_capacity": 136480.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 9.26, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Single Package", "minimum_capacity": 136481.0, "maximum_capacity": 238840.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 9.26, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1: CHECK THIS" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Single Package", "minimum_capacity": 136481.0, "maximum_capacity": 238840.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 9.08, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1: CHECK THIS" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Split System", "minimum_capacity": 136481.0, "maximum_capacity": 238840.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 9.26, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1: CHECK THIS" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Split System", "minimum_capacity": 136481.0, "maximum_capacity": 238840.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 9.08, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1: CHECK THIS" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Single Package", "minimum_capacity": 238841.0, "maximum_capacity": 759999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 8.39, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Single Package", "minimum_capacity": 238841.0, "maximum_capacity": 759999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 8.21, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Split System", "minimum_capacity": 238841.0, "maximum_capacity": 759999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 8.39, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Split System", "minimum_capacity": 238840.0, "maximum_capacity": 759999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 8.21, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Single Package", "minimum_capacity": 760000.0, "maximum_capacity": 9999999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 8.12, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Single Package", "minimum_capacity": 760000.0, "maximum_capacity": 9999999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 7.94, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "Split System", "minimum_capacity": 760000.0, "maximum_capacity": 9999999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 8.12, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "Split System", "minimum_capacity": 760000.0, "maximum_capacity": 9999999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": 7.94, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": null, "ptac_eer_coefficient_2": null, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "Electric Resistance or None", "subcategory": "PTAC", "minimum_capacity": 0, "maximum_capacity": 9999999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": null, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": 12.5, "ptac_eer_coefficient_2": 0.213, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" }, { "cooling_type": "AirCooled", "heating_type": "All Other", "subcategory": "PTAC", "minimum_capacity": 0, "maximum_capacity": 9999999.0, "start_date": "9/9/1919", "end_date": "2999-09-09T00:00:00+00:00", "minimum_seasonal_energy_efficiency_ratio": null, "minimum_energy_efficiency_ratio": null, "minimum_integrated_part_load_value": null, "minimum_integrated_energy_efficiency_ratio": null, "ptac_eer_coefficient_1": 10.9, "ptac_eer_coefficient_2": 0.213, "cool_cap_ft": "DXCOOL-NECB2011-REF-CAPFT", "cool_cap_fflow": "DXCOOL-NECB2011-REF-CAPFFLOW", "cool_eir_ft": "DXCOOL-NECB2011-REF-COOLEIRFT", "cool_eir_fflow": "DXCOOL-NECB2011-REF-COOLEIRFFLOW", "cool_plf_fplr": "DXCOOL-NECB2011-REF-COOLPLFFPLR", "notes": "From NECB 2011, Table 5.2.12.1" } ] } } }