{ "space_types": [ { "template": "189.1-2009", "building_type": "FullServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 1.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "FullServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Dining Rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "FullServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "FullServiceRestaurant Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "FullServiceRestaurant Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.080001756670937, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp", "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "FullServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.08, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "FullServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "FullServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "FullServiceRestaurant Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "FullServiceRestaurant Infil Half On", "gas_equipment_per_area": 276.72, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "FullServiceRestaurant Gas Equip", "electric_equipment_per_area": 25.500010979193352, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp Kitchen", "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp Kitchen", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1501.0, "service_water_heating_peak_flow_per_area": 0.08860759494, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "FullServiceRestaurant SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "FullServiceRestaurant Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Dining Rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "ER_Exam", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.43, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.09, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "ER_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 6.25, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.9900000000000001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "ER_Trauma", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.43, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.92, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "ER_Triage", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.43, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.97, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "ICU_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Critical and Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "ICU_Open", "rgb": "78_167_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Critical and Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.19, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "ICU_PatRm", "rgb": "78_167_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Critical and Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.19, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.08, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": 70.46, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "Hospital Kitchen Gas", "electric_equipment_per_area": 5.47, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 150.0, "service_water_heating_area": 10000.0, "service_water_heating_peak_flow_per_area": 0.015, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 924.6539123, "exhaust_fan_pressure_rise": 0.5024115756, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Hospital Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "Lab", "rgb": "204_120_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "General", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Laboratories", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.22, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 2850.0, "service_water_heating_peak_flow_per_area": 0.000701754386, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "Lobby", "rgb": "31_162_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.76, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 1.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 3, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.92, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical ClgSetp", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 600.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.99, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "PatCorridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "PatRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Nursing", "ventilation_secondary_space_type": "Patient Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 280.0, "service_water_heating_peak_flow_per_area": 0.003571428571, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "PhysTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.09, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5280.0, "service_water_heating_peak_flow_per_area": 0.0001893939394, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Hospital", "space_type": "Radiology", "rgb": "136_78_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Medical procedure", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 7.28, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Bldg Equip", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5250.0, "service_water_heating_peak_flow_per_area": 0.0001904761905, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "Banquet", "rgb": "230_196_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "LargeHotel Bldg Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0000000000000004, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "LargeHotel Bldg Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.26, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.45, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "LargeHotel Bldg Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp", "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "LargeHotel GuestRoom Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.68, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel GuestRoom Equip", "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp", "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "LargeHotel SWH GuestRoom", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.08, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "LargeHotel Bldg Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": 373.8, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "LargeHotel Kitchen Gas", "electric_equipment_per_area": 24.16, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "LargeHotel Kitchen Equip", "heating_setpoint_schedule": "LargeHotel Kitchen HtgSetp", "cooling_setpoint_schedule": "LargeHotel Kitchen ClgSetp", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1112.0, "service_water_heating_peak_flow_per_area": 0.1196043165, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "LargeHotel SWH Kitchen", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 697.8520092823027, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "LargeHotel Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Dry Cleaners, Laundries", "ventilation_secondary_space_type": "Commercial Laundry", "ventilation_per_area": 0, "ventilation_per_person": 25, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.0, "occupancy_schedule": "LargeHotel Bldg Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": 123.8, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "LargeHotel LaundryRoom Gas", "electric_equipment_per_area": 2.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel LaundryRoom Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": 156.6, "service_water_heating_area": 840.0, "service_water_heating_peak_flow_per_area": 0.1864285714, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "LargeHotel SWH Laundry", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 87.23150116, "exhaust_fan_pressure_rise": 0.5024115756, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "LargeHotel Laundry Exhaust_Always On", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "LargeHotel Bldg Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.38, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "LargeHotel Bldg Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.26, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.53, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "LargeHotel Bldg Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.51, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "LargeHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Shipping and receiving", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.0, "occupancy_schedule": "LargeHotel Bldg Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.13, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "MidriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dormitory", "lighting_secondary_space_type": "Living Quarters", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "MidriseApartment Apartment Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "MidriseApartment Apartment Occ", "occupancy_activity_schedule": "MidriseApartment Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "MidriseApartment Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "MidriseApartment Apartment Equip", "heating_setpoint_schedule": "MidriseApartment Apartment HtgSetp", "cooling_setpoint_schedule": "MidriseApartment Apartment ClgSetp", "service_water_heating_peak_flow_rate": 3.5, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003684210526, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "MidriseApartment DHW", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "MidriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.45, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "MidriseApartment Corridor Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "MidriseApartment Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": null, "heating_setpoint_schedule": "MidriseApartment Corridor HtgSetp", "cooling_setpoint_schedule": "MidriseApartment Corridor ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "MidriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "MidriseApartment Office Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "MidriseApartment Office Occ", "occupancy_activity_schedule": "MidriseApartment Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "MidriseApartment Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.87, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "MidriseApartment Office Equip", "heating_setpoint_schedule": "MidriseApartment Office HtgSetp", "cooling_setpoint_schedule": "MidriseApartment Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": "#N/A", "ventilation_per_person": "#N/A", "ventilation_air_changes": "#N/A", "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Small Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "BreakRoom", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.08, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "ClosedOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.75, "occupancy_schedule": "Office Work Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.64, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.45, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Office Work Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.16, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.56, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "OpenOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.25, "occupancy_schedule": "Office Work Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.71, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "PrintRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.79, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Medium Office Bldg Occ", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Stairs-Active", "lighting_secondary_space_type": "General", "lighting_per_area": 0.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "Vending", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.45, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.85, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "WholeBuilding - Lg Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Large Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Large Office Bldg Occ", "occupancy_activity_schedule": "Large Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Large Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Large Office Bldg Equip", "heating_setpoint_schedule": "Large Office HtgSetp", "cooling_setpoint_schedule": "Large Office ClgSetp", "service_water_heating_peak_flow_rate": 63.9, "service_water_heating_area": 498588.0, "service_water_heating_peak_flow_per_area": 0.0001281619293, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Office SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "WholeBuilding - Md Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Medium Office Bldg Occ", "occupancy_activity_schedule": "Medium Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Medium Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.54, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Medium Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": 27.7, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0005165212203, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Medium Office Bldg Swh", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Office", "space_type": "WholeBuilding - Sm Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Small Office Bldg Occ", "occupancy_activity_schedule": "Small Office Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Small Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.54, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Small Office Bldg Equip", "heating_setpoint_schedule": "Small Office HtgSetp", "cooling_setpoint_schedule": "Small Office ClgSetp", "service_water_heating_peak_flow_rate": 3.0, "service_water_heating_area": 5502.0, "service_water_heating_peak_flow_per_area": 0.0005452562704, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Office SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Anesthesia", "rgb": "204_120_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 1.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Anesthesia Storage", "ventilation_per_area": 1.2, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.009259259259, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Outpatient SWH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 54.520672421626536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "BioHazard", "rgb": "204_120_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Bedpan Room", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 92.94, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "CleanWork", "rgb": "204_120_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Medical Supply", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Utility / Workroom", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 46.45, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "DressingRoom", "rgb": "136_78_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dressing/Locker/Fitting Room", "lighting_secondary_space_type": "General", "lighting_per_area": 0.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.8000000000000002, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Mechanical Equipment Room", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.64, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Exam", "rgb": "136_78_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.8000000000000002, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Hall", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.29, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Telecommunication centers and data entry areas", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.8000000000000002, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Janitor", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Janitors Closet / Utility", "ventilation_per_area": 1.5, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.87, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.8000000000000002, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "LockerRoom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dressing/Locker/Fitting Room", "lighting_secondary_space_type": "General", "lighting_per_area": 0.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Lockers", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.94, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.19, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Lounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.94, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.19, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "MRI", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 38.63, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 440.0, "service_water_heating_peak_flow_per_area": 0.002272727273, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Outpatient SWH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 166.5909435105255, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "MRI_Control", "rgb": "136_78_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.8, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 168.0, "service_water_heating_peak_flow_per_area": 0.005952380952, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Outpatient SWH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 63.6074511585643, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "MedGas", "rgb": "204_120_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "NurseStation", "rgb": "31_162_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 1.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 3, "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": 17.4, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.0, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "Outpatient Bldg Equip", "electric_equipment_per_area": 2.92, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient OR HtgSetp", "cooling_setpoint_schedule": "Outpatient OR ClgSetp", "service_water_heating_peak_flow_rate": 6.0, "service_water_heating_area": 470.0, "service_water_heating_peak_flow_per_area": 0.01276595745, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Outpatient SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.8000000000000002, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "PACU", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Recovery", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.19, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.009259259259, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Outpatient SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "PhysicalTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.09, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 946, "service_water_heating_peak_flow_per_area": 0.001057082452, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Outpatient SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "PreOp", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Patient Room", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 263.5, "service_water_heating_peak_flow_per_area": 0.003795066414, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Outpatient SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "ProcedureRoom", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.43, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 3, "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.19, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 285.0, "service_water_heating_peak_flow_per_area": 0.00350877193, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Outpatient SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Soil Work", "rgb": "204_120_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Medical Supply", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Soiled Linen, Sorting", "ventilation_per_area": 1.5, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 79.50931394820536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Stairs-Active", "lighting_secondary_space_type": "General", "lighting_per_area": 0.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Toilet", "rgb": "169_169_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.29, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 34.075420263516584, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Outpatient", "space_type": "Xray", "rgb": "169_31_159", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.95, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 900.0, "service_water_heating_peak_flow_per_area": 0.001111111111, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Outpatient SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 66.67, "occupancy_schedule": "PrimarySchool Cafeteria Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.72, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Classroom", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 23.22, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.02, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.45, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.9, "occupancy_schedule": "PrimarySchool Gym Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3400000000000001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.08, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": 220.5, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "PrimarySchool Kitchen Gas", "electric_equipment_per_area": 13.130000000000003, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "PrimarySchool Kitchen Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": 100.0, "service_water_heating_area": 1808.0, "service_water_heating_peak_flow_per_area": 0.05530973451, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "PrimarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 572.9644137011418, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "PrimarySchool Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Libraries", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 21.36, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.02, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "PrimarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": 56.5, "service_water_heating_area": 2045.0, "service_water_heating_peak_flow_per_area": 0.02762836186, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "PrimarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 104.17534794566214, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "QuickServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 1.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "QuickServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "QuickServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "QuickServiceRestaurant Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "QuickServiceRestaurant Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 8.740003763064701, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp", "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "QuickServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.08, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "QuickServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "QuickServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "QuickServiceRestaurant Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "QuickServiceRestaurant Infil Half On", "gas_equipment_per_area": 298.6, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "QuickServiceRestaurant Gas Equip", "electric_equipment_per_area": 20.400008783354682, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.3, "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp Kitchen", "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp Kitchen", "service_water_heating_peak_flow_rate": 40.0, "service_water_heating_area": 1250.0, "service_water_heating_peak_flow_per_area": 0.032, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "QuickServiceRestaurant SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 575.7279076578998, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "QuickServiceRestaurant Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Retail", "space_type": "Back_Space", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.546, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Retail", "space_type": "Entry", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Mall Concourse", "lighting_per_area": 1.53, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Retail", "space_type": "Point_of_Sale", "rgb": "171_222_78", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.53, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.4500006243070729, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Retail", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.53, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Clothiers, furniture", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.22000009472245247, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Auditorium", "rgb": "230_196_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Auditorium", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 92.94, "occupancy_schedule": "SecondarySchool Auditorium Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3400000000000001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 66.84, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Kitchen Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Classroom", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 23.22, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.68, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.45, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.31, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 92.94, "occupancy_schedule": "SecondarySchool Gym Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3400000000000001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH Showers", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.08, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.48, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": 258.6, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SecondarySchool Kitchen Gas", "electric_equipment_per_area": 15.05, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SecondarySchool Kitchen Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 2325.0, "service_water_heating_peak_flow_per_area": 0.05720430108, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SecondarySchool Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Libraries", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 21.34, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.68, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "SecondarySchool Office Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SecondarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": 52.2, "service_water_heating_area": 2260.0, "service_water_heating_peak_flow_per_area": 0.02309734513, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 110.36763444376396, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": "#N/A", "ventilation_per_person": "#N/A", "ventilation_air_changes": "#N/A", "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0751, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.45, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Elec/MechRoom", "rgb": "41_31_171", "lighting_standard": null, "lighting_primary_space_type": null, "lighting_secondary_space_type": null, "lighting_per_area": "#N/A", "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.223, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 198.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Exercise", "rgb": "154_230_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Exercise Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SmallHotel Exercise Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.55, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Exercise Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "GuestLounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.08, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel GuestRoom Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.97, "occupancy_schedule": "SmallHotel GuestRoom Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.68, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel GuestRoom Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": 1.75, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.004985754986, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SmallHotel SWH GuestRoom", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Laundry Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Dry Cleaners, Laundries", "ventilation_secondary_space_type": "Commercial Laundry", "ventilation_per_area": 0, "ventilation_per_person": 25, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SmallHotel Laundry Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": 42.6, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": "SmallHotel Laundry Gas", "electric_equipment_per_area": 1.0400004477788662, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Laundry Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": 67.5, "service_water_heating_area": 1053.0, "service_water_heating_peak_flow_per_area": 0.0641025641, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SmallHotel SWH Laundry", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Meeting", "rgb": "230_196_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Meeting Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "SmallHotel Meeting Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.61, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Meeting Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Office Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "SmallHotel Office Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.61, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Office Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "PublicRestroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.85, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.51, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 69.45023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "StaffLounge", "rgb": "31_169_34", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.08, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel StaffLounge Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 31.34, "occupancy_schedule": "SmallHotel StaffLounge Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.67, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel StaffLounge Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Stairs-Active", "lighting_secondary_space_type": "General", "lighting_per_area": 0.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SmallHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Storage Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "StripMall", "space_type": "WholeBuilding", "rgb": "171_222_78", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "StripMall Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "StripMall Bldg Occ", "occupancy_activity_schedule": "StripMall Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "StripMall Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.2900001248614146, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "StripMall Bldg Equip", "heating_setpoint_schedule": "StripMall HtgSetp", "cooling_setpoint_schedule": "StripMall ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SuperMarket", "space_type": "Deli/Bakery", "rgb": "31_169_34", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.53, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": 6.25, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "SuperMarket Bldg Equip", "electric_equipment_per_area": 3.6400015672260313, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": 5.0, "service_water_heating_area": 2334.5, "service_water_heating_peak_flow_per_area": 0.00214178625, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SuperMarket SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 520.8767397283107, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SuperMarket_Deli_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SuperMarket", "space_type": "DryStorage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Shipping and receiving", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SuperMarket", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "SuperMarket", "space_type": "Sales/Produce", "rgb": "230_196_120", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.53, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.36000015500037674, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Warehouse", "space_type": "Bulk", "rgb": "41_31_169", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Medium/Bulky Material Storage", "lighting_per_area": 0.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "Warehouse Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse Bldg Occ", "occupancy_activity_schedule": "Warehouse Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.17000007319462238, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse HtgSetp BulkStorage", "cooling_setpoint_schedule": "Warehouse ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Warehouse", "space_type": "Fine", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine Material Storage", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "Warehouse Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse Bldg Occ", "occupancy_activity_schedule": "Warehouse Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse HtgSetp FineStorage", "cooling_setpoint_schedule": "Warehouse ClgSetp FineStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "189.1-2009", "building_type": "Warehouse", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "Warehouse Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.96, "occupancy_schedule": "Warehouse Bldg Occ", "occupancy_activity_schedule": "Warehouse Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse HtgSetp", "cooling_setpoint_schedule": "Warehouse ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "FullServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "FullServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Dining Rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2016, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.032, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "FullServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2016, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": 205.81, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH", "electric_equipment_per_area": 37.53, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1501.0, "service_water_heating_peak_flow_per_area": 0.08860759494, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "HighriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentHighRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "HighriseApartment", "space_type": "Apartment_topfloor_NS", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentHighRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0575970048, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "HighriseApartment", "space_type": "Apartment_topfloor_WE", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentHighRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0803777592, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "HighriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "HighriseApartment", "space_type": "Corridor_topfloor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0234460331, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "HighriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": 1.1, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedrooms", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2004_2007", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "Basement", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Basement", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_BSMT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Basement", "ventilation_secondary_space_type": "For Hospital", "ventilation_per_area": 0.049, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.5, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Dining Rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "ER_Exam", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "ER_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "ER_Trauma", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "ER_Triage", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "ICU_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "ICU_Open", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Newborn Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "ICU_PatRm", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Newborn Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": 51.16, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "electric_equipment_per_area": 7.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 150.0, "service_water_heating_area": 10000.0, "service_water_heating_peak_flow_per_area": 0.015, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 229133.6778, "exhaust_fan_pressure_rise": 124.5, "exhaust_fan_maximum_flow_rate": 7200.0, "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "Lab", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "General", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Laboratories", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 2850.0, "service_water_heating_peak_flow_per_area": 0.000701754386, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "Lobby", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.09999999999999999, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 2.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 3, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 600.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.99, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "PatCorridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "PatRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Nursing", "ventilation_secondary_space_type": "Patient Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 280.0, "service_water_heating_peak_flow_per_area": 0.003571428571, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "PhysTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5280.0, "service_water_heating_peak_flow_per_area": 0.0001893939394, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Hospital", "space_type": "Radiology", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Medical procedure", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5250.0, "service_water_heating_peak_flow_per_area": 0.0001904761905, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Banquet", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "HotelLarge MeetingRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.301, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Basement", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Basement", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Corridor2", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.627, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "GuestRoom2", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.977, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.004734848485, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "GuestRoom3", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0566608, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.627, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "GuestRoom4", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.050904, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.977, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.004734848485, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": 767.0, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH", "electric_equipment_per_area": 47.2, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1112.0, "service_water_heating_peak_flow_per_area": 0.1196043165, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.16, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 4000.0, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Dry Cleaners, Laundries", "ventilation_secondary_space_type": "Commercial Laundry", "ventilation_per_area": 0, "ventilation_per_person": 25, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.0, "occupancy_schedule": "HotelLarge LaundryRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": 170.0, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "electric_equipment_per_area": 5.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": 840.0, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004", "exhaust_fan_efficiency": 0.16, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 500.0, "exhaust_schedule": "HotelLarge Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelLarge Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.7500000000000001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Retail2", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "LargeHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Shipping and receiving", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.24999999999999997, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "MidriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "MidriseApartment", "space_type": "Apartment_topfloor_NS", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0575970048, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "MidriseApartment", "space_type": "Apartment_topfloor_WE", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0803777592, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "MidriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "MidriseApartment", "space_type": "Corridor_topfloor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0234460331, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "MidriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": 1.1, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedrooms", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2004_2007", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_No_Setback", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "BreakRoom", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.58, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "ClosedOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.75, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.87, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.29, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Dining", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeLarge BLDG_EQUIP_SCH", "cooling_setpoint_schedule": "OfficeLarge BLDG_EQUIP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "OfficeLarge Data Center", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "OfficeLarge", "lighting_secondary_space_type": "Data Center", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 20.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge ALWAYS_ON", "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "OfficeLarge Main Data Center", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "OfficeLarge", "lighting_secondary_space_type": "Data Center", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 45.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge ALWAYS_ON", "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "OpenOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.25, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.96, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "PrintRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Stairs-Active", "lighting_secondary_space_type": "General", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "Vending", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.85, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "WholeBuilding - Lg Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.1, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.201599, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.74973447, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 27.7, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0005165212203, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "WholeBuilding - Md Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.1, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 51.0, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0009509957485, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Office", "space_type": "WholeBuilding - Sm Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.1, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.6, "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.63, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 3.0, "service_water_heating_area": 5502.0, "service_water_heating_peak_flow_per_area": 0.0005452562704, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Anesthesia", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Treatment / Examination", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 8.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.01851851852, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 54.520672421626536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "BioHazard", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Bedpan Room", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 99.89, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "CleanWork", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Utility / Workroom", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 4.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 49.95, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "DressingRoom", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "ElevatorPumpRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.1, "electric_equipment_fraction_lost": 0.9, "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_24_7", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Exam", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Hall", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Hall_infil", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Telecommunication centers and data entry areas", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Janitor", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Bathroom/ Public", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "LockerRoom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Lounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "MRI", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 440.0, "service_water_heating_peak_flow_per_area": 0.004545454545, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 166.5909435105255, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "MRI_Control", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 168.0, "service_water_heating_peak_flow_per_area": 0.0119047619, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 63.6074511585643, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "MedGas", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "NurseStation", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 2.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Operating rooms outpatient", "ventilation_per_area": 0.5, "ventilation_per_person": 30, "ventilation_air_changes": "", "minimum_total_air_changes": 20.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": 23.87, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.0, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH", "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH", "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH", "service_water_heating_peak_flow_rate": 12.0, "service_water_heating_area": 472.0, "service_water_heating_peak_flow_per_area": 0.02542372881, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "PACU", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 316.0, "service_water_heating_peak_flow_per_area": 0.006329113924, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "PhysicalTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 946, "service_water_heating_peak_flow_per_area": 0.002114164905, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "PreOp", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 263.5, "service_water_heating_peak_flow_per_area": 0.007590132827, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "ProcedureRoom", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Procedure Room Outpatient", "ventilation_per_area": 0.8, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 15.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 285.0, "service_water_heating_peak_flow_per_area": 0.00701754386, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Reception", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 29.97, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Soil Work", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Medical Supply", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Linen Storage", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 79.50931394820536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Toilet", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 34.075420263516584, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Undeveloped", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Bathroom/ Public", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Outpatient", "space_type": "Xray", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 900.0, "service_water_heating_peak_flow_per_area": 0.002222222222, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Classroom", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 25.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": 453.7, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 17.7, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 100.0, "service_water_heating_area": 1808.0, "service_water_heating_peak_flow_per_area": 0.05530973451, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 572.9644137011418, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Libraries", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": 0.0, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "PrimarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 56.5, "service_water_heating_area": 2045.0, "service_water_heating_peak_flow_per_area": 0.02762836186, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 104.17534794566214, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "QuickServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "QuickServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2016, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.85, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "QuickServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2016, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": 250.86, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH", "electric_equipment_per_area": 25.166, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.3, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 40.0, "service_water_heating_area": 1250.0, "service_water_heating_peak_flow_per_area": 0.032, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 575.7279076578998, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantFastFood Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Retail", "space_type": "Back_Space", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Retail", "space_type": "Entry", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Retail", "space_type": "Point_of_Sale", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Retail", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Clothiers, furniture", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Auditorium", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Auditorium", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 150.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 7.15, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Classroom", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 35.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Playing Area", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.23, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": 532.1, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 20.65, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 2325.0, "service_water_heating_peak_flow_per_area": 0.05720430108, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Libraries", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SecondarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": 52.2, "service_water_heating_area": 2260.0, "service_water_heating_peak_flow_per_area": 0.02309734513, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 110.36763444376396, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Corridor4", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0258, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Elec/MechRoom", "rgb": "41_31_174", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 198.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "ElevatorCore", "rgb": "41_31_174", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "ElevatorCore4", "rgb": "41_31_174", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.05042, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Exercise", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Spectator areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 19.94, "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "GuestLounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.42, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "GuestRoom123Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel GuestRoom Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedrooms", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "GuestRoom123Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedrooms", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "GuestRoom4Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel GuestRoom Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedrooms", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0504, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "GuestRoom4Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedrooms", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0504, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Dry Cleaners, Laundries", "ventilation_secondary_space_type": "Commercial Laundry", "ventilation_per_area": 0, "ventilation_per_person": 25, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": 129.9, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch", "electric_equipment_per_area": 2.57, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": 1053.0, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 82.2, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Meeting", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.574, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Office Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "HotelSmall Office_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.28, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "PublicRestroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.85, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 69.45023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "StaffLounge", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 51.28, "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Stairs-Active", "lighting_secondary_space_type": "General", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Stair4", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Stairs-Active", "lighting_secondary_space_type": "General", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.1196, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Storage Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Storage4Front", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Storage Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0504, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SmallHotel", "space_type": "Storage4Rear", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Storage Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.1196, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "StripMall", "space_type": "Strip mall - type 1", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": 0.95, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type1_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0891675017, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type1_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "StripMall", "space_type": "Strip mall - type 2", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": 0.375, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type2_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0628789142, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type2_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "StripMall", "space_type": "Strip mall - type 3", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type3_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0628789142, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type3_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SuperMarket", "space_type": "Deli/Bakery", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": 8.53, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "SuperMarket Bldg Equip", "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": 5.0, "service_water_heating_area": 2334.5, "service_water_heating_peak_flow_per_area": 0.00214178625, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SuperMarket SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 520.8767397283107, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SuperMarket_Deli_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SuperMarket", "space_type": "DryStorage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Shipping and receiving", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SuperMarket", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "SuperMarket", "space_type": "Sales/Produce", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Warehouse", "space_type": "Bulk", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Medium/Bulky Material Storage", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0444, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse Bulk Infil Schedule", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.237684638, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Warehouse", "space_type": "Fine", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine Material Storage", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0444, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse Fine Infil Schedule", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2004", "building_type": "Warehouse", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.96, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0433, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse Office Infil Schedule", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Office_Plug_SCH", "heating_setpoint_schedule": "Warehouse HtgSetp", "cooling_setpoint_schedule": "Warehouse ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "FullServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "FullServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Restaurant dining rooms", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2016, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.032, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "FullServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2016, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": 205.81, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH", "electric_equipment_per_area": 37.53, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1501.0, "service_water_heating_peak_flow_per_area": 0.08860759494, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "HighriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "HighriseApartment", "space_type": "Apartment_topfloor_NS", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0575970048, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "HighriseApartment", "space_type": "Apartment_topfloor_WE", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0803777592, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "HighriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "HighriseApartment", "space_type": "Corridor_topfloor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0234460331, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "HighriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": 1.1, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Living rooms", "ventilation_per_area": 0.085, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2004_2007", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Basement", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Basement", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_BSMT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Basement", "ventilation_secondary_space_type": "For Hospital", "ventilation_per_area": 0.072495, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.5, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "ER_Exam", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "ER_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "ER_Trauma", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "ER_Triage", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "ICU_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "ICU_Open", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Newborn Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "ICU_PatRm", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Newborn Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": 51.16, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "electric_equipment_per_area": 7.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 150.0, "service_water_heating_area": 10000.0, "service_water_heating_peak_flow_per_area": 0.015, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 229133.6778, "exhaust_fan_pressure_rise": 124.5, "exhaust_fan_maximum_flow_rate": 7200.0, "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Lab", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Medical Supply", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Science laboratories", "ventilation_per_area": 0.18, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 2850.0, "service_water_heating_peak_flow_per_area": 0.000701754386, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Lobby", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Lobby", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.33, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.33, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.04, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 2.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 3, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 600.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 2.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 3, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.92, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 600.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.99, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "PatCorridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "PatCorridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "PatRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Nursing", "ventilation_secondary_space_type": "Patient Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 280.0, "service_water_heating_peak_flow_per_area": 0.003571428571, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "PhysTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5280.0, "service_water_heating_peak_flow_per_area": 0.0001893939394, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Hospital", "space_type": "Radiology", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Medical procedure", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5250.0, "service_water_heating_peak_flow_per_area": 0.0001904761905, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Banquet", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "HotelLarge MeetingRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.301, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Basement", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Corridor2", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.627, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "GuestRoom2", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.977, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.004734848485, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "GuestRoom3", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0566608, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.627, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "GuestRoom4", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.050904, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.977, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.004734848485, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": 767.0, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH", "electric_equipment_per_area": 47.2, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1112.0, "service_water_heating_peak_flow_per_area": 0.1196043165, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.16, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 4000.0, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coinoperated laundries", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.0, "occupancy_schedule": "HotelLarge LaundryRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": 170.0, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "electric_equipment_per_area": 5.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": 840.0, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004", "exhaust_fan_efficiency": 0.16, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 500.0, "exhaust_schedule": "HotelLarge Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelLarge Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Retail2", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "LargeHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.25, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "MidriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "MidriseApartment", "space_type": "Apartment_topfloor_NS", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0575970048, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "MidriseApartment", "space_type": "Apartment_topfloor_WE", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0803777592, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "MidriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "MidriseApartment", "space_type": "Corridor_topfloor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0234460331, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "MidriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": 1.1, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Living rooms", "ventilation_per_area": 0.085, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2004_2007", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_No_Setback", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "BreakRoom", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "ClosedOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.75, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.64, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.16, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.56, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "OfficeLarge Data Center", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "OfficeLarge", "lighting_secondary_space_type": "Data Center", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 20.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge ALWAYS_ON", "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "OfficeLarge Main Data Center", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "OfficeLarge", "lighting_secondary_space_type": "Data Center", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 45.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge ALWAYS_ON", "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "OpenOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.25, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.71, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "PrintRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.79, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Stairs-Active", "lighting_secondary_space_type": "General", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "Vending", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.85, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "WholeBuilding - Lg Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.201599, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.74973447, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 27.7, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0005165212203, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "WholeBuilding - Md Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 51.0, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0009509957485, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Office", "space_type": "WholeBuilding - Sm Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.1, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.6, "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.63, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 3.0, "service_water_heating_area": 5502.0, "service_water_heating_peak_flow_per_area": 0.0005452562704, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Anesthesia", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Treatment / Examination", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 8.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.01851851852, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 54.520672421626536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "BioHazard", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 99.89, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "CleanWork", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Utility / Workroom", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 4.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 49.95, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "DressingRoom", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "ElevatorPumpRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.1, "electric_equipment_fraction_lost": 0.9, "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_24_7", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Exam", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Hall", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Hall_infil", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Janitor", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "LockerRoom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Lounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "MRI", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 440.0, "service_water_heating_peak_flow_per_area": 0.004545454545, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 166.5909435105255, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "MRI_Control", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 168.0, "service_water_heating_peak_flow_per_area": 0.0119047619, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 63.6074511585643, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "MedGas", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "NurseStation", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 2.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Operating rooms outpatient", "ventilation_per_area": 0.5, "ventilation_per_person": 30, "ventilation_air_changes": "", "minimum_total_air_changes": 20.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": 23.87, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.0, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH", "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH", "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH", "service_water_heating_peak_flow_rate": 12.0, "service_water_heating_area": 472.0, "service_water_heating_peak_flow_per_area": 0.02542372881, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "PACU", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 316.0, "service_water_heating_peak_flow_per_area": 0.006329113924, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "PhysicalTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 946, "service_water_heating_peak_flow_per_area": 0.002114164905, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "PreOp", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 263.5, "service_water_heating_peak_flow_per_area": 0.007590132827, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "ProcedureRoom", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Procedure Room Outpatient", "ventilation_per_area": 0.8, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 15.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 285.0, "service_water_heating_peak_flow_per_area": 0.00701754386, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Reception", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 29.97, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Soil Work", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Linen Storage", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 79.50931394820536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Toilet", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 34.075420263516584, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Undeveloped", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Outpatient", "space_type": "Xray", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 0.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 900.0, "service_water_heating_peak_flow_per_area": 0.002222222222, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (ages 5-8)", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 25.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": 453.7, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 17.7, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 100.0, "service_water_heating_area": 1808.0, "service_water_heating_peak_flow_per_area": 0.05530973451, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 572.9644137011418, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "PrimarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 56.5, "service_water_heating_area": 2045.0, "service_water_heating_peak_flow_per_area": 0.02762836186, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 104.17534794566214, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "QuickServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "QuickServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2016, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.85, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "QuickServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2004_2007", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2016, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": 250.86, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH", "electric_equipment_per_area": 25.166, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.3, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 40.0, "service_water_heating_area": 1250.0, "service_water_heating_peak_flow_per_area": 0.032, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 575.7279076578998, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantFastFood Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Retail", "space_type": "Back_Space", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Retail", "space_type": "Entry", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Retail", "space_type": "Point_of_Sale", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Retail", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Auditorium", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Auditorium seating area", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 150.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 7.15, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (age 9 plus)", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 35.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Playing Area", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.23, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": 532.1, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 20.65, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 2325.0, "service_water_heating_peak_flow_per_area": 0.05720430108, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SecondarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": 52.2, "service_water_heating_area": 2260.0, "service_water_heating_peak_flow_per_area": 0.02309734513, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 110.36763444376396, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Corridor4", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0258, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Elec/MechRoom", "rgb": "41_31_173", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 198.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "ElevatorCore", "rgb": "41_31_173", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "ElevatorCore4", "rgb": "41_31_173", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.05042, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Exercise", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Gymnasium/Exercise Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/weight rooms", "ventilation_per_area": 0.06, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 19.94, "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "GuestLounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.42, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "GuestRoom123Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel GuestRoom Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "GuestRoom123Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "GuestRoom4Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel GuestRoom Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0504, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "GuestRoom4Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hotel/Motel", "lighting_secondary_space_type": "Guest Rooms", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0504, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coinoperated laundries", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": 129.9, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch", "electric_equipment_per_area": 2.57, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": 1053.0, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 82.2, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Meeting", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.574, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Office Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "HotelSmall Office_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.28, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "PublicRestroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.85, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 69.45023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "StaffLounge", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 51.28, "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Stairs-Active", "lighting_secondary_space_type": "General", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Stair4", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Stairs-Active", "lighting_secondary_space_type": "General", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.1196, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Storage Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.2016, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Storage4Front", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Storage Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0504, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SmallHotel", "space_type": "Storage4Rear", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Storage Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.1196, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "StripMall", "space_type": "Strip mall - type 1", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": 0.72, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type1_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0891675017, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type1_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "StripMall", "space_type": "Strip mall - type 2", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": 0.5, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type2_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0628789142, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type2_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "StripMall", "space_type": "Strip mall - type 3", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": 0.07, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type3_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0628789142, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type3_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SuperMarket", "space_type": "Deli/Bakery", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": 6.25, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "SuperMarket Bldg Equip", "electric_equipment_per_area": 3.6400015672260313, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": 5.0, "service_water_heating_area": 2334.5, "service_water_heating_peak_flow_per_area": 0.00214178625, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SuperMarket SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 520.8767397283107, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SuperMarket_Deli_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SuperMarket", "space_type": "DryStorage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Active Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SuperMarket", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "SuperMarket", "space_type": "Sales/Produce", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Retail (not including accent lighting)", "lighting_secondary_space_type": "Sales Area", "lighting_per_area": 1.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.36000015500037674, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Warehouse", "space_type": "Bulk", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Medium/Bulky Material Storage", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0444, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse Bulk Infil Schedule", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.237684638, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Warehouse", "space_type": "Fine", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine Material Storage", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0444, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse Fine Infil Schedule", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2007", "building_type": "Warehouse", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2007", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.96, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0433, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse Office Infil Schedule", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Office_Plug_SCH", "heating_setpoint_schedule": "Warehouse HtgSetp", "cooling_setpoint_schedule": "Warehouse ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "FullServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "FullServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_DINING_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Restaurant dining rooms", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.032, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "FullServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": 205.81, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH", "electric_equipment_per_area": 37.53, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1501.0, "service_water_heating_peak_flow_per_area": 0.08860759494, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "HighriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "HighriseApartment", "space_type": "Apartment_topfloor_NS", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.031998336, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "HighriseApartment", "space_type": "Apartment_topfloor_WE", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0446543107, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "HighriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2010", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "HighriseApartment", "space_type": "Corridor_topfloor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2010", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0130255739, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "HighriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": 1.11, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Living rooms", "ventilation_per_area": 0.085, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2010_2013", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "Basement", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Basement", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_BSMT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Basement", "ventilation_secondary_space_type": "For Hospital", "ventilation_per_area": 0.072495, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.5, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "ER_Exam", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "ER_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.87, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.33, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "ER_Trauma", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "ER_Triage", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "ICU_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.87, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.33, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "ICU_Open", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 1.15, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Newborn Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "ICU_PatRm", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.62, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Newborn Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": 51.16, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "electric_equipment_per_area": 7.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 150.0, "service_water_heating_area": 10000.0, "service_water_heating_peak_flow_per_area": 0.015, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": 0.16, "exhaust_fan_power": 924.6539122990511, "exhaust_fan_pressure_rise": 124.5, "exhaust_fan_maximum_flow_rate": 7200.0, "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "Lab", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "For Medical/Industrial/Research", "lighting_per_area": 1.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Science laboratories", "ventilation_per_area": 0.18, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 2850.0, "service_water_heating_peak_flow_per_area": 0.000701754386, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "Lobby", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.33, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.87, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.33, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.04, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 1.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 3, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 600.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "PatCorridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "PatRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.62, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Nursing", "ventilation_secondary_space_type": "Patient Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 280.0, "service_water_heating_peak_flow_per_area": 0.003571428571, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "PhysTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5280.0, "service_water_heating_peak_flow_per_area": 0.0001893939394, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Hospital", "space_type": "Radiology", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 1.32, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Medical procedure", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5250.0, "service_water_heating_peak_flow_per_area": 0.0001904761905, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Banquet", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0254576, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.301, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 1.0, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 0.0, "exhaust_fan_maximum_flow_rate": 1017.43109, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Basement", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH_2010", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0192416, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Corridor2", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.627, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": "\n", "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "GuestRoom2", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.977, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.004734848485, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "GuestRoom3", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0566608, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.627, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "GuestRoom4", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.050904, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.977, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.004734848485, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0513, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": 767.0, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH", "electric_equipment_per_area": 47.2, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1112.0, "service_water_heating_peak_flow_per_area": 0.1196043165, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.16, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 4000.0, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coinoperated laundries", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": 170.0, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "electric_equipment_per_area": 5.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": 840.0, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004", "exhaust_fan_efficiency": 0.16, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 500.0, "exhaust_schedule": "HotelLarge Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.06, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Retail2", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "LargeHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.25, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "MidriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "MidriseApartment", "space_type": "Apartment_topfloor_NS", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.031998336, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "MidriseApartment", "space_type": "Apartment_topfloor_WE", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0446543107, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "MidriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2010", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "MidriseApartment", "space_type": "Corridor_topfloor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2010", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0130255739, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "MidriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": 1.11, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Living rooms", "ventilation_per_area": 0.085, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2010_2013", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_No_Setback", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "BreakRoom", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "ClosedOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.75, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.64, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.23, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.16, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.56, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "OfficeLarge Data Center", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "OfficeLarge", "lighting_secondary_space_type": "Data Center", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 20.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge ALWAYS_ON", "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "OfficeLarge Main Data Center", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "OfficeLarge", "lighting_secondary_space_type": "Data Center", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 45.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge ALWAYS_ON", "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "OpenOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.25, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.71, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "PrintRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.79, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_per_area": 0.69, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "Vending", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.85, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "WholeBuilding - Lg Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.111999776, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.74973447, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 27.7, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0005165212203, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "WholeBuilding - Md Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2010", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 51.0, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0009509957485, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Office", "space_type": "WholeBuilding - Sm Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.6, "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.63, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 3.0, "service_water_heating_area": 5502.0, "service_water_heating_peak_flow_per_area": 0.0005452562704, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Anesthesia", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Treatment / Examination", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 8.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.01851851852, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 54.520672421626536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "BioHazard", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 99.89, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "CleanWork", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Utility / Workroom", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 4.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.23, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 49.95, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "DressingRoom", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "ElevatorPumpRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.1, "electric_equipment_fraction_lost": 0.9, "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_ADD_DF", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Exam", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Hall", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Hall_infil", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Janitor", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH_20102013", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "LockerRoom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1.07, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Lounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1.07, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "MRI", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 1.32, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 440.0, "service_water_heating_peak_flow_per_area": 0.004545454545, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 166.5909435105255, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "MRI_Control", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 1.32, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 168.0, "service_water_heating_peak_flow_per_area": 0.0119047619, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 63.6074511585643, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "MedGas", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "NurseStation", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.87, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 1.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Operating rooms outpatient", "ventilation_per_area": 0.5, "ventilation_per_person": 30, "ventilation_air_changes": "", "minimum_total_air_changes": 20.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": 23.87, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.0, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH", "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH", "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH", "service_water_heating_peak_flow_rate": 12.0, "service_water_heating_area": 472.0, "service_water_heating_peak_flow_per_area": 0.02542372881, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH_20102013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "PACU", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 1.15, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 316.0, "service_water_heating_peak_flow_per_area": 0.006329113924, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "PhysicalTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 946.0, "service_water_heating_peak_flow_per_area": 0.002114164905, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "PreOp", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.62, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 263.5, "service_water_heating_peak_flow_per_area": 0.007590132827, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "ProcedureRoom", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Procedure Room Outpatient", "ventilation_per_area": 0.8, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 15.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 285.0, "service_water_heating_peak_flow_per_area": 0.00701754386, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Reception", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 29.97, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Soil Work", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Linen Storage", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 79.50931394820536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Toilet", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 34.075420263516584, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Undeveloped", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Outpatient", "space_type": "Xray", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 1.32, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 900.0, "service_water_heating_peak_flow_per_area": 0.002222222222, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.24, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (ages 5-8)", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 25.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Fitness Area", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": 453.7, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 17.7, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 100.0, "service_water_heating_area": 1808.0, "service_water_heating_peak_flow_per_area": 0.05530973451, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 572.9644137011418, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.18, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "PrimarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 56.5, "service_water_heating_area": 2045.0, "service_water_heating_peak_flow_per_area": 0.02762836186, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 104.17534794566214, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "QuickServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "QuickServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.85, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "QuickServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": 250.86, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH", "electric_equipment_per_area": 25.166, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.3, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 40.0, "service_water_heating_area": 1250.0, "service_water_heating_peak_flow_per_area": 0.032, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 575.7279076578998, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantFastFood Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Retail", "space_type": "Back_Space", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Retail", "space_type": "Entry", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Retail", "space_type": "Point_of_Sale", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_per_area": 1.68, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Retail", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_per_area": 1.68, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Auditorium", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Auditorium", "lighting_per_area": 0.79, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Auditorium seating area", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 150.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 7.15, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.24, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (age 9 plus)", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 35.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Fitness Area", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.23, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": 532.1, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 20.65, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 2325.0, "service_water_heating_peak_flow_per_area": 0.05720430108, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.18, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SecondarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": 52.2, "service_water_heating_area": 2260.0, "service_water_heating_peak_flow_per_area": 0.02309734513, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 110.36763444376396, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Corridor4", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0143, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Elec/MechRoom", "rgb": "41_31_175", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 198.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "ElevatorCore", "rgb": "41_31_175", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "ElevatorCore4", "rgb": "41_31_175", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.02801, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Exercise", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Fitness Area", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/weight rooms", "ventilation_per_area": 0.06, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 19.94, "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "GuestLounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.42, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "GuestRoom123Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Highway Lodging", "lighting_per_area": 0.75, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "GuestRoom123Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Highway Lodging", "lighting_per_area": 0.75, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "GuestRoom4Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Highway Lodging", "lighting_per_area": 0.75, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.028, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "GuestRoom4Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Highway Lodging", "lighting_per_area": 0.75, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.028, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coinoperated laundries", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": 129.9, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch", "electric_equipment_per_area": 2.57, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": 1053.0, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 82.2, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Meeting", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.23, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.574, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "HotelSmall Office_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.28, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "PublicRestroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_RESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.85, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 69.45023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "StaffLounge", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 51.28, "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_per_area": 0.69, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Stair4", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_per_area": 0.69, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0664, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Storage4Front", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.028, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SmallHotel", "space_type": "Storage4Rear", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.06644, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "StripMall", "space_type": "Strip mall - type 1", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": 0.42, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type1_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0495376, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type1_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "StripMall", "space_type": "Strip mall - type 2", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": 0.22, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type2_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0349328, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type2_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "StripMall", "space_type": "Strip mall - type 3", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": 0.07, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type3_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0349328, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type3_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SuperMarket", "space_type": "Deli/Bakery", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_per_area": 1.68, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": 6.25, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "SuperMarket Bldg Equip", "electric_equipment_per_area": 3.6400015672260313, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": 5.0, "service_water_heating_area": 2334.5, "service_water_heating_peak_flow_per_area": 0.00214178625, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SuperMarket SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 520.8767397283107, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SuperMarket_Deli_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SuperMarket", "space_type": "DryStorage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SuperMarket", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "SuperMarket", "space_type": "Sales/Produce", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_per_area": 1.68, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.36000015500037674, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Warehouse", "space_type": "Bulk", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Medium/Bulky Material Storage", "lighting_per_area": 0.58, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0444, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse Bulk Infil Schedule", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.237684638, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.0, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Warehouse", "space_type": "Fine", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine Material Storage", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0444, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse Fine Infil Schedule", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.0, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2010", "building_type": "Warehouse", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.96, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0433, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse Office Infil Schedule", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.0, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Office_Plug_SCH", "heating_setpoint_schedule": "Warehouse HtgSetp", "cooling_setpoint_schedule": "Warehouse ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "FullServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "FullServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_DINING_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Restaurant dining rooms", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.032, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "FullServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.21, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": 205.81, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH", "electric_equipment_per_area": 37.53, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1501.0, "service_water_heating_peak_flow_per_area": 0.08860759494, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "HighriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "HighriseApartment", "space_type": "Apartment_topfloor_NS", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.031998336, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "HighriseApartment", "space_type": "Apartment_topfloor_WE", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0446543107, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "HighriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "HighriseApartment", "space_type": "Corridor_topfloor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0130255739, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "HighriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Living rooms", "ventilation_per_area": 0.085, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentHighRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2010_2013", "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "Basement", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Basement", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_BSMT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Basement", "ventilation_secondary_space_type": "For Hospital", "ventilation_per_area": 0.072495, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.5, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "ER_Exam", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "ER_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.71, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "ER_Trauma", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 2.48, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "ER_Triage", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 2.48, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "ICU_NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.71, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "ICU_Open", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 1.15, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Newborn Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "ICU_PatRm", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.62, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Newborn Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.21, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": 51.16, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "electric_equipment_per_area": 7.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 150.0, "service_water_heating_area": 10000.0, "service_water_heating_peak_flow_per_area": 0.015, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 924.6539122990511, "exhaust_fan_pressure_rise": 124.5, "exhaust_fan_maximum_flow_rate": 7200.0, "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "Lab", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "General", "lighting_per_area": 1.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Science laboratories", "ventilation_per_area": 0.18, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 2850.0, "service_water_heating_peak_flow_per_area": 0.000701754386, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "Lobby", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "NurseStn", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.71, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.04, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 2.48, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 3, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 600.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.99, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "PatCorridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "PatRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.62, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Nursing", "ventilation_secondary_space_type": "Patient Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 280.0, "service_water_heating_peak_flow_per_area": 0.003571428571, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "PhysTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5280.0, "service_water_heating_peak_flow_per_area": 0.0001893939394, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Hospital", "space_type": "Radiology", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 1.51, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Medical procedure", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5250.0, "service_water_heating_peak_flow_per_area": 0.0001904761905, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Banquet", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0254576, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.301, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 1.0, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 0.0, "exhaust_fan_maximum_flow_rate": 2000.0, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Basement", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH_2010", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0192416, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Corridor2", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "General", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.627, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": "\n", "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "GuestRoom2", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "General", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.977, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.004734848485, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "GuestRoom3", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "General", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0566608, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.627, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "GuestRoom4", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "General", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.050904, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.977, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.004734848485, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.21, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0513, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": 767.0, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH", "electric_equipment_per_area": 47.2, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1112.0, "service_water_heating_peak_flow_per_area": 0.1196043165, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.385, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 4000.0, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coinoperated laundries", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": 170.0, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "electric_equipment_per_area": 5.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": 840.0, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004", "exhaust_fan_efficiency": 0.385, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 500.0, "exhaust_schedule": "HotelLarge Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.06, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Retail2", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "LargeHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.25, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "MidriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "MidriseApartment", "space_type": "Apartment_topfloor_NS", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.031998336, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "MidriseApartment", "space_type": "Apartment_topfloor_WE", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.0446543107, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "MidriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "MidriseApartment", "space_type": "Corridor_topfloor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.0130255739, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "MidriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Living rooms", "ventilation_per_area": 0.085, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2010_2013", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "BreakRoom", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "ClosedOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.75, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.64, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.23, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.16, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.42, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.56, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "OfficeLarge Data Center", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "OfficeLarge", "lighting_secondary_space_type": "Data Center", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013", "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 20.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge ALWAYS_ON", "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "OfficeLarge Main Data Center", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "OfficeLarge", "lighting_secondary_space_type": "Data Center", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013", "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 45.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge ALWAYS_ON", "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "OpenOffice", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.25, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.71, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "PrintRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.79, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_per_area": 0.69, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "Vending", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.85, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "WholeBuilding - Lg Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.74973447, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 27.7, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0005165212203, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "WholeBuilding - Md Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2013", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 51.0, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0009509957485, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Office", "space_type": "WholeBuilding - Sm Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.6, "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.63, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 3.0, "service_water_heating_area": 5502.0, "service_water_heating_peak_flow_per_area": 0.0005452562704, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Anesthesia", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Treatment / Examination", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 8.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.01851851852, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 54.520672421626536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "BioHazard", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 99.89, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "CleanWork", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Utility / Workroom", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 4.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.23, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 49.95, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "DressingRoom", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "ElevatorPumpRoom", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.1, "electric_equipment_fraction_lost": 0.9, "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_ADD_DF", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Exam", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Hall", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Hall_infil", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Janitor", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH_20102013", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "LockerRoom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Healthcare Facility", "lighting_per_area": 0.92, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Lounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Healthcare Facility", "lighting_per_area": 0.92, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "MRI", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 1.51, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 440.0, "service_water_heating_peak_flow_per_area": 0.004545454545, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 166.5909435105255, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "MRI_Control", "rgb": "136_78_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 1.51, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 168.0, "service_water_heating_peak_flow_per_area": 0.0119047619, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 63.6074511585643, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "MedGas", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "NurseStation", "rgb": "31_162_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.71, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 2.48, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Operating rooms outpatient", "ventilation_per_area": 0.5, "ventilation_per_person": 30, "ventilation_air_changes": "", "minimum_total_air_changes": 20.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": 23.87, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.0, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH", "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH", "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH", "service_water_heating_peak_flow_rate": 12.0, "service_water_heating_area": 472.0, "service_water_heating_peak_flow_per_area": 0.02542372881, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH_20102013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "PACU", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 1.15, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 316.0, "service_water_heating_peak_flow_per_area": 0.006329113924, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "PhysicalTherapy", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 946.0, "service_water_heating_peak_flow_per_area": 0.002114164905, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "PreOp", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.62, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 263.5, "service_water_heating_peak_flow_per_area": 0.007590132827, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "ProcedureRoom", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Emergency", "lighting_per_area": 2.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Procedure Room Outpatient", "ventilation_per_area": 0.8, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 15.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 285.0, "service_water_heating_peak_flow_per_area": 0.00701754386, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Reception", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 29.97, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Soil Work", "rgb": "204_120_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Linen Storage", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 79.50931394820536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.792, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Toilet", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 34.075420263516584, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Undeveloped", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2010", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Outpatient", "space_type": "Xray", "rgb": "169_31_159", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 1.51, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 900.0, "service_water_heating_peak_flow_per_area": 0.002222222222, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.24, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (ages 5-8)", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 25.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.21, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": 453.7, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 17.7, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 100.0, "service_water_heating_area": 1808.0, "service_water_heating_peak_flow_per_area": 0.05530973451, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 572.9644137011418, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.19, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.42, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "PrimarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 56.5, "service_water_heating_area": 2045.0, "service_water_heating_peak_flow_per_area": 0.02762836186, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 104.17534794566214, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "QuickServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "QuickServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.85, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "QuickServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.21, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": 250.86, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH", "electric_equipment_per_area": 25.166, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.3, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 40.0, "service_water_heating_area": 1250.0, "service_water_heating_peak_flow_per_area": 0.032, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 575.7279076578998, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantFastFood Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Retail", "space_type": "Back_Space", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Retail", "space_type": "Entry", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Retail", "space_type": "Point_of_Sale", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_per_area": 1.44, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Retail", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_per_area": 1.44, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Auditorium", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "For Auditorium", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Auditorium seating area", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 150.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 7.15, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.24, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (age 9 plus)", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 35.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 1.21, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.23, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": 532.1, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 20.65, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 2325.0, "service_water_heating_peak_flow_per_area": 0.05720430108, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.19, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.42, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SecondarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": 52.2, "service_water_heating_area": 2260.0, "service_water_heating_peak_flow_per_area": 0.02309734513, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 110.36763444376396, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Corridor4", "rgb": "169_31_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Corridor", "lighting_secondary_space_type": "General", "lighting_per_area": 0.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0143, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Elec/MechRoom", "rgb": "41_31_175", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 198.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "ElevatorCore", "rgb": "41_31_175", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "ElevatorCore4", "rgb": "41_31_175", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.02801, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Exercise", "rgb": "154_230_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/weight rooms", "ventilation_per_area": 0.06, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 19.94, "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "GuestLounge", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.42, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "GuestRoom123Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "GuestRoom123Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "GuestRoom4Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.028, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "GuestRoom4Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.028, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Laundry/Washing Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coinoperated laundries", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": 129.9, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch", "electric_equipment_per_area": 2.57, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": 1053.0, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 82.2, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.42, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Meeting", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.23, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.574, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "HotelSmall Office_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.28, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "PublicRestroom", "rgb": "169_169_31", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_RESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.85, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 69.45023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "StaffLounge", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 51.28, "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_per_area": 0.69, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Stair4", "rgb": "230_157_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_per_area": 0.69, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0664, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Storage4Front", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.028, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SmallHotel", "space_type": "Storage4Rear", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.06644, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "StripMall", "space_type": "Strip mall - type 1", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": 0.38346, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type1_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0495376, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type1_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "StripMall", "space_type": "Strip mall - type 2", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": 0.18346, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type2_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0349328, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type2_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "StripMall", "space_type": "Strip mall - type 3", "rgb": "171_222_78", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": 0.0336, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type3_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0349328, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type3_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SuperMarket", "space_type": "Deli/Bakery", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_per_area": 1.44, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": 6.25, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "SuperMarket Bldg Equip", "electric_equipment_per_area": 3.6400015672260313, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": 5.0, "service_water_heating_area": 2334.5, "service_water_heating_peak_flow_per_area": 0.00214178625, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SuperMarket SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 520.8767397283107, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SuperMarket_Deli_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SuperMarket", "space_type": "DryStorage", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SuperMarket", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "SuperMarket", "space_type": "Sales/Produce", "rgb": "230_196_120", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Sales Area", "lighting_secondary_space_type": "General", "lighting_per_area": 1.44, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.36000015500037674, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Warehouse", "space_type": "Bulk", "rgb": "41_31_169", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Medium/Bulky Material Storage", "lighting_per_area": 0.58, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse ALWAYS_ON", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.237684638, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Warehouse", "space_type": "Fine", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine Material Storage", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse ALWAYS_ON", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "90.1-2013", "building_type": "Warehouse", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.96, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse ALWAYS_ON", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Office_Plug_SCH", "heating_setpoint_schedule": "Warehouse HtgSetp", "cooling_setpoint_schedule": "Warehouse ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "FullServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": 1.0, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "FullServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "FullServiceRestaurant", "lighting_secondary_space_type": "Dining", "lighting_per_area": 2.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "FullServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Dining Rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "FullServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "FullServiceRestaurant Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "FullServiceRestaurant Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.6, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp", "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "FullServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "FullServiceRestaurant", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.52, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "FullServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "FullServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "FullServiceRestaurant Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "FullServiceRestaurant Infil Half On", "gas_equipment_per_area": 378.75, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "FullServiceRestaurant Gas Equip", "electric_equipment_per_area": 35.0, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp Kitchen", "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp Kitchen", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1501.0, "service_water_heating_peak_flow_per_area": 0.08860759494, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "FullServiceRestaurant Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "Basement", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Basement", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Basement", "ventilation_secondary_space_type": "For Hospital", "ventilation_per_area": "", "ventilation_per_person": 21.186, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.5, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.749, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 1.355, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Dining", "lighting_per_area": 2.575, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Dining Rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "ER_Exam", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ER_Exam", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5000000000000002, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "ER_NurseStn", "rgb": "31_162_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ER_NurseStn", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.25, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "ER_Trauma", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ER_Trauma", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "ER_Triage", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ER_Triage", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "ICU_NurseStn", "rgb": "31_162_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ICU_NurseStn", "lighting_per_area": 1.71, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "ICU_Open", "rgb": "78_167_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ICU_Open", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": "#N/A", "ventilation_per_person": "#N/A", "ventilation_air_changes": "#N/A", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0000000000000004, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "ICU_PatRm", "rgb": "78_167_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ICU_PatRm", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.69, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.42, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Kitchen", "ventilation_per_area": 0.371, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": 96.7, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "Hospital Kitchen Gas", "electric_equipment_per_area": 7.5, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "Hospital Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 150.0, "service_water_heating_area": 10000.0, "service_water_heating_peak_flow_per_area": 0.015, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 924.6539123, "exhaust_fan_pressure_rise": 0.5024115756, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Hospital Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "Lab", "rgb": "204_120_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Lab", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Laboratories", "ventilation_per_area": 1.4, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 2850.0, "service_water_heating_peak_flow_per_area": 0.000701754386, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "Lobby", "rgb": "31_162_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1.03, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.09999999999999999, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "NurseStn", "rgb": "31_162_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "NurseStn", "lighting_per_area": 1.458, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.04, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "OR", "lighting_per_area": 9.745, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Operating rooms", "ventilation_per_area": 0.7, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical ClgSetp", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 600.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Office", "lighting_per_area": 2.395, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.99, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "PatCorridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "PatCorridor", "lighting_per_area": 1.32, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "PatRoom", "rgb": "78_167_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "PatRoom", "lighting_per_area": 2.188, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Patient rooms", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 280.0, "service_water_heating_peak_flow_per_area": 0.003571428571, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "PhysTherapy", "rgb": "154_230_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "PhysTherapy", "lighting_per_area": 2.51, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5000000000000002, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5280.0, "service_water_heating_peak_flow_per_area": 0.0001893939394, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Hospital", "space_type": "Radiology", "rgb": "136_78_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 2.21, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Radiology", "ventilation_per_area": 0.7, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5250.0, "service_water_heating_peak_flow_per_area": 0.0001904761905, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Banquet", "rgb": "230_196_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Banquet", "lighting_per_area": 2.56, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dining rooms", "ventilation_per_area": 0, "ventilation_per_person": 21.2, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 1.0, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 1.0e-05, "exhaust_fan_maximum_flow_rate": 2000.0, "exhaust_schedule": "Always On", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Basement", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Basement", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.5, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Cafe", "lighting_per_area": 1.46, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 1.22, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp", "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Corridor2", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 1.22, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp", "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "LargeHotel GuestRoom Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel GuestRoom Equip", "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp", "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "GuestRoom2", "rgb": "78_167_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "LargeHotel GuestRoom Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel GuestRoom Equip", "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp", "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp", "service_water_heating_peak_flow_rate": 23.743, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.08993560606, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "GuestRoom3", "rgb": "78_167_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "LargeHotel GuestRoom Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel GuestRoom Equip", "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp", "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "GuestRoom4", "rgb": "78_167_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "LargeHotel GuestRoom Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel GuestRoom Equip", "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp", "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp", "service_water_heating_peak_flow_rate": 11.247, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.04260227273, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.56, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": 511.0, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "LargeHotel Kitchen Gas", "electric_equipment_per_area": 47.1989, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "LargeHotel Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "LargeHotel Kitchen HtgSetp", "cooling_setpoint_schedule": "LargeHotel Kitchen ClgSetp", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1112.0, "service_water_heating_peak_flow_per_area": 0.1196043165, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": 1.0, "exhaust_fan_power": 689.0, "exhaust_fan_pressure_rise": 1.0e-05, "exhaust_fan_maximum_flow_rate": 94.2477825, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Laundry", "lighting_per_area": 1.14, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Dry Cleaners, Laundries", "ventilation_secondary_space_type": "Commercial Laundry", "ventilation_per_area": 0, "ventilation_per_person": 25, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": 170.0, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "LargeHotel LaundryRoom Gas", "electric_equipment_per_area": 5.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel LaundryRoom Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": 156.6, "service_water_heating_area": 840.0, "service_water_heating_peak_flow_per_area": 0.1864285714, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Pre2004", "exhaust_fan_efficiency": 0.34, "exhaust_fan_power": 87.0, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 500.0, "exhaust_schedule": "Always On", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1.88, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.7500000000000001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Mechanical", "lighting_per_area": 0.8000000000000002, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Retail", "lighting_per_area": 3.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Retail2", "rgb": "171_222_78", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Retail", "lighting_per_area": 3.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "LargeHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Storage", "lighting_per_area": 0.37, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Shipping and receiving", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.24999999999999997, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "MidriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36000000000000004, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "MidriseApartment Apartment Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 36, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "MidriseApartment Apartment Occ", "occupancy_activity_schedule": "MidriseApartment Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "MidriseApartment Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "MidriseApartment Apartment HtgSetp", "cooling_setpoint_schedule": "MidriseApartment Apartment ClgSetp", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "MidriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.92, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "MidriseApartment Corridor Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "MidriseApartment Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS Pre2004", "heating_setpoint_schedule": "MidriseApartment UnitHeater HtgSP Sch", "cooling_setpoint_schedule": "MidriseApartment UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "MidriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 2.04, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "MidriseApartment Office Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "MidriseApartment Office Occ", "occupancy_activity_schedule": "MidriseApartment Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "MidriseApartment OFFICE Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_Pre2004", "heating_setpoint_schedule": "MidriseApartment Office HtgSetp", "cooling_setpoint_schedule": "MidriseApartment Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": null, "lighting_primary_space_type": null, "lighting_secondary_space_type": null, "lighting_per_area": null, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": "#N/A", "ventilation_per_person": "#N/A", "ventilation_air_changes": "#N/A", "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Small Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "BreakRoom", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "BreakRoom", "lighting_per_area": 1.884, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.63, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "ClosedOffice", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "ClosedOffice", "lighting_per_area": 1.727, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.75, "occupancy_schedule": "Office Work Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.87, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Conference", "lighting_per_area": 1.84, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.785, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Office Work Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.29, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 2.355, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "IT_Room", "lighting_per_area": 1.55, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 2.04, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "OpenOffice", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "OpenOffice", "lighting_per_area": 1.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.25, "occupancy_schedule": "Office Work Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.96, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "PrintRoom", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "PrintRoom", "lighting_per_area": 1.55, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Restroom", "lighting_per_area": 1.41, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Medium Office Bldg Occ", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Stair", "lighting_per_area": 0.942, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Storage", "lighting_per_area": 1.27, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "Vending", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Vending", "lighting_per_area": 1.57, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.85, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "WholeBuilding - Lg Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "WholeBuilding - Lg Office", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Large Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Large Office Bldg Occ", "occupancy_activity_schedule": "Large Office Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Large Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Large Office Bldg Equip", "heating_setpoint_schedule": "Large Office HtgSetp", "cooling_setpoint_schedule": "Large Office ClgSetp", "service_water_heating_peak_flow_rate": 63.9, "service_water_heating_area": 498588.0, "service_water_heating_peak_flow_per_area": 0.0001281619293, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Office SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "WholeBuilding - Md Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "WholeBuilding - Md Office", "lighting_per_area": 1.57, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Medium Office Bldg Occ", "occupancy_activity_schedule": "Medium Office Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Medium Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Medium Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": 29.67, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0005532557619, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Medium Office Bldg Swh", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Office", "space_type": "WholeBuilding - Sm Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "WholeBuilding - Sm Office", "lighting_per_area": 1.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Small Office Bldg Occ", "occupancy_activity_schedule": "Small Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Small Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Small Office Bldg Equip", "heating_setpoint_schedule": "Small Office HtgSetp", "cooling_setpoint_schedule": "Small Office ClgSetp", "service_water_heating_peak_flow_rate": 3.0, "service_water_heating_area": 5502.0, "service_water_heating_peak_flow_per_area": 0.0005452562704, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Office SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Anesthesia", "rgb": "204_120_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Anesthesia", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Nursery, Exam", "ventilation_per_area": 0.45, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 8.0, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.009259259259, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 54.520672421626536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "BioHazard", "rgb": "204_120_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "BioHazard", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Bedpan Room", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Cafe", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 92.9, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "CleanWork", "rgb": "204_120_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "CleanWork", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Utility / Workroom", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 4.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Conference", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 46.45, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "DressingRoom", "rgb": "136_78_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "DressingRoom", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "ElevatorPumpRoom", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.1, "electric_equipment_fraction_lost": 0.9, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Exam", "rgb": "136_78_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Exam", "lighting_per_area": 1.6000000000000003, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Hall", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Hall", "lighting_per_area": 0.8000000000000002, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Hall_infil", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Hall", "lighting_per_area": 0.8000000000000002, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "IT_Room", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Telecommunication centers and data entry areas", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Janitor", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Janitor", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.9, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "LockerRoom", "rgb": "169_169_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "LockerRoom", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Lounge", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Lounge", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "MRI", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "MRI", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 53.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Radiology Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 440.0, "service_water_heating_peak_flow_per_area": 0.002272727273, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 166.5909435105255, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "MRI_Control", "rgb": "136_78_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "MRI_Control", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 168.0, "service_water_heating_peak_flow_per_area": 0.005952380952, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 63.6074511585643, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "MedGas", "rgb": "204_120_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "MedGas", "lighting_per_area": 1.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "NurseStation", "rgb": "31_162_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "NurseStation", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "OR", "lighting_per_area": 7.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Patient rooms", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 15.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": 23.87, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.0, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "Outpatient Bldg Equip", "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient OR HtgSetp", "cooling_setpoint_schedule": "Outpatient OR ClgSetp", "service_water_heating_peak_flow_rate": 6.0, "service_water_heating_area": 472.0, "service_water_heating_peak_flow_per_area": 0.01271186441, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "PACU", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "PACU", "lighting_per_area": 2.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.333, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 316.0, "service_water_heating_peak_flow_per_area": 0.003164556962, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "PhysicalTherapy", "rgb": "154_230_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "PhysicalTherapy", "lighting_per_area": 1.6000000000000003, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 946, "service_water_heating_peak_flow_per_area": 0.001057082452, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "PreOp", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "PreOp", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.333, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 9.29, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 263.5, "service_water_heating_peak_flow_per_area": 0.003795066414, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "ProcedureRoom", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "ProcedureRoom", "lighting_per_area": 1.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Patient rooms", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 15.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 285.0, "service_water_heating_peak_flow_per_area": 0.00350877193, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Reception", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.9, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Soil Work", "rgb": "204_120_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Soil Work", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Soil work Outpatient", "ventilation_per_area": 0.556, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 79.50931394820536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Stair", "lighting_per_area": 0.8000000000000002, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": 1.0, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Toilet", "rgb": "169_169_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Toilet", "lighting_per_area": 0.8000000000000002, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.7, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 34.075420263516584, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Undeveloped", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-1999", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Outpatient", "space_type": "Xray", "rgb": "169_31_159", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Xray", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Radiology Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 900.0, "service_water_heating_peak_flow_per_area": 0.001111111111, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Cafeteria", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 66.67, "occupancy_schedule": "PrimarySchool Cafeteria Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Classroom", "lighting_per_area": 2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Classroom", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 23.22, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Gym", "lighting_per_area": 1.07, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.9, "occupancy_schedule": "PrimarySchool Gym Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": 302.6, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "PrimarySchool Kitchen Gas", "electric_equipment_per_area": 17.7, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "PrimarySchool Kitchen Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": 100.0, "service_water_heating_area": 1808.0, "service_water_heating_peak_flow_per_area": 0.05530973451, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "PrimarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 572.9644137011418, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "PrimarySchool Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Library", "lighting_per_area": 2.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Libraries", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 21.36, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1.14, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Mechanical", "lighting_per_area": 0.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "PrimarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Restroom", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": 56.5, "service_water_heating_area": 2045.0, "service_water_heating_peak_flow_per_area": 0.02762836186, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "PrimarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 104.17534794566214, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "QuickServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": 1.0, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "QuickServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "QuickServiceRestaurant", "lighting_secondary_space_type": "Dining", "lighting_per_area": 1.44, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "QuickServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "QuickServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "QuickServiceRestaurant Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "QuickServiceRestaurant Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 12.0, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp", "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "QuickServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "QuickServiceRestaurant", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.55, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "QuickServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "QuickServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "QuickServiceRestaurant Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "QuickServiceRestaurant Infil Half On", "gas_equipment_per_area": 409.6, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "QuickServiceRestaurant Gas Equip", "electric_equipment_per_area": 28.0, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.3, "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp Kitchen", "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp Kitchen", "service_water_heating_peak_flow_rate": 40.0, "service_water_heating_area": 1250.0, "service_water_heating_peak_flow_per_area": 0.032, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "QuickServiceRestaurant Bldg Swh", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 575.7279076578998, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "QuickServiceRestaurant Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Retail", "space_type": "Back_Space", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Back_Space", "lighting_per_area": 1.16593, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Retail", "space_type": "Entry", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Entry", "lighting_per_area": 3.36774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail FRONT ENTRY COOLING", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Retail", "space_type": "Point_of_Sale", "rgb": "171_222_78", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Point_of_Sale", "lighting_per_area": 3.36774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Retail", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Retail", "lighting_per_area": 3.36774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Clothiers, furniture", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Auditorium", "rgb": "230_196_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Auditorium", "lighting_per_area": 1.12, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Auditorium", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 92.94, "occupancy_schedule": "SecondarySchool Auditorium Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Cafeteria", "lighting_per_area": 1.34, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 66.84, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.79, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Kitchen Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Classroom", "lighting_per_area": 2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Classroom", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 23.22, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.86, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.31, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Gym", "lighting_per_area": 1.06, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 92.94, "occupancy_schedule": "SecondarySchool Gym Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH Showers", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Gym - audience", "rgb": "154_230_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Gym", "lighting_per_area": 1.06, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.9, "occupancy_schedule": "SecondarySchool Gym Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH Showers", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.56, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.48, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": 354.9, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SecondarySchool Kitchen Gas", "electric_equipment_per_area": 20.65, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SecondarySchool Kitchen Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 2325.0, "service_water_heating_peak_flow_per_area": 0.05720430108, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SecondarySchool Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.52, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Libraries", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 21.34, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Mechanical", "lighting_per_area": 0.75, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.87, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "SecondarySchool Office Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SecondarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Restroom", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": 52.2, "service_water_heating_area": 2260.0, "service_water_heating_peak_flow_per_area": 0.02309734513, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 110.36763444376396, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Attic", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.86, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 198.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "ElevatorCore", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Exercise", "rgb": "154_230_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Exercise", "lighting_per_area": 1.37, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Exercise Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 31.33, "occupancy_schedule": "SmallHotel Exercise Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.07, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Exercise Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "GuestLounge", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "GuestLounge", "lighting_per_area": 1.31, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel StaffLounge Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.43, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.74, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel GuestRoom Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Living rooms", "ventilation_per_area": 0.085, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.97, "occupancy_schedule": "SmallHotel GuestRoom Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel GuestRoom Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": 1.75, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.004985754986, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Laundry", "lighting_per_area": 1.04, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Laundry Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Dry Cleaners, Laundries", "ventilation_secondary_space_type": "Commercial Laundry", "ventilation_per_area": 0, "ventilation_per_person": 25, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SmallHotel Laundry Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": 58.4, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "SmallHotel Laundry Gas", "electric_equipment_per_area": 2.03, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Laundry Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": 67.5, "service_water_heating_area": 1053.0, "service_water_heating_peak_flow_per_area": 0.0641025641, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Mechanical", "lighting_per_area": 0.96, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Meeting", "rgb": "230_196_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Meeting", "lighting_per_area": 2.13, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Meeting Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "SmallHotel Meeting Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Meeting Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Office", "lighting_per_area": 2.01, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Office Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "SmallHotel Office Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Office Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "PublicRestroom", "rgb": "169_169_31", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "PublicRestroom", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.85, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 69.45023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "StaffLounge", "rgb": "31_169_34", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "StaffLounge", "lighting_per_area": 1.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel StaffLounge Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 31.34, "occupancy_schedule": "SmallHotel StaffLounge Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 7.17, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel StaffLounge Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Stair", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SmallHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Storage", "lighting_per_area": 0.45, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Storage Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "StripMall", "space_type": "Strip mall - type 1", "rgb": "171_222_78", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "StripMall", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 5.5983371904, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "StripMall Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "StripMall Bldg Occ", "occupancy_activity_schedule": "StripMall Activity", "infiltration_per_exterior_area": 0.22303105, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "StripMall Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "StripMall Bldg Equip", "heating_setpoint_schedule": "StripMall HtgSetp", "cooling_setpoint_schedule": "StripMall ClgSetp", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "StripMall", "space_type": "Strip mall - type 2", "rgb": "171_222_78", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "StripMall", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 3.2989869504, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "StripMall Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "StripMall Bldg Occ", "occupancy_activity_schedule": "StripMall Activity", "infiltration_per_exterior_area": 0.22303105, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "StripMall Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "StripMall Bldg Equip", "heating_setpoint_schedule": "StripMall HtgSetp", "cooling_setpoint_schedule": "StripMall ClgSetp", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "StripMall", "space_type": "Strip mall - type 3", "rgb": "171_222_78", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "StripMall", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 2.698833312, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "StripMall Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "StripMall Bldg Occ", "occupancy_activity_schedule": "StripMall Activity", "infiltration_per_exterior_area": 0.22303105, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "StripMall Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "StripMall Bldg Equip", "heating_setpoint_schedule": "StripMall HtgSetp", "cooling_setpoint_schedule": "StripMall ClgSetp", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SuperMarket", "space_type": "Deli/Bakery", "rgb": "31_169_34", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SuperMarket", "lighting_secondary_space_type": "Deli/Bakery", "lighting_per_area": 2.78, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": 8.53, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "SuperMarket Bldg Equip", "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": 5.0, "service_water_heating_area": 2334.5, "service_water_heating_peak_flow_per_area": 0.00214178625, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SuperMarket SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 520.8767397283107, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SuperMarket_Deli_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SuperMarket", "space_type": "DryStorage", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SuperMarket", "lighting_secondary_space_type": "DryStorage", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Shipping and receiving", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SuperMarket", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SuperMarket", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.98, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "SuperMarket", "space_type": "Sales/Produce", "rgb": "230_196_120", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SuperMarket", "lighting_secondary_space_type": "Sales/Produce", "lighting_per_area": 2.78, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Warehouse", "space_type": "Bulk", "rgb": "41_31_169", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Bulk", "lighting_per_area": 0.3102962, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "Warehouse Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse Bldg Occ", "occupancy_activity_schedule": "Warehouse Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.2378318, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse HtgSetp BulkStorage", "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Warehouse", "space_type": "Fine", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine", "lighting_per_area": 1.0813914, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "Warehouse Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse Bldg Occ", "occupancy_activity_schedule": "Warehouse Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse HtgSetp FineStorage", "cooling_setpoint_schedule": "Warehouse ClgSetp FineStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref 1980-2004", "building_type": "Warehouse", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Office", "lighting_per_area": 2.0150669, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "Warehouse Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.96, "occupancy_schedule": "Warehouse Bldg Occ", "occupancy_activity_schedule": "Warehouse Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.7497275, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse HtgSetp", "cooling_setpoint_schedule": "Warehouse Cooling Setpoint", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "FullServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "FullServiceRestaurant", "lighting_secondary_space_type": "Dining", "lighting_per_area": 2.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "FullServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Dining Rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "FullServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "FullServiceRestaurant Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "FullServiceRestaurant Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.6, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp", "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "FullServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "FullServiceRestaurant", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.52, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "FullServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "FullServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "FullServiceRestaurant Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "FullServiceRestaurant Infil Half On", "gas_equipment_per_area": 378.75, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "FullServiceRestaurant Gas Equip", "electric_equipment_per_area": 35.0, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp Kitchen", "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp Kitchen", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1501.0, "service_water_heating_peak_flow_per_area": 0.08860759494, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "FullServiceRestaurant Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "Basement", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Basement", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Basement", "ventilation_secondary_space_type": "For Hospital", "ventilation_per_area": "", "ventilation_per_person": 21.186, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.5, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.749, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 1.355, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Dining", "lighting_per_area": 2.575, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Dining Rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "ER_Exam", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ER_Exam", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5000000000000002, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "ER_NurseStn", "rgb": "31_162_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ER_NurseStn", "lighting_per_area": 1.66, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.25, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "ER_Trauma", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ER_Trauma", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "ER_Triage", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ER_Triage", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.67, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "ICU_NurseStn", "rgb": "31_162_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ICU_NurseStn", "lighting_per_area": 1.71, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "ICU_Open", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ICU_Open", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0000000000000004, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "ICU_PatRm", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "ICU_PatRm", "lighting_per_area": 3.841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Recovery and ICU", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0000000000000004, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical HtgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.42, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Kitchen", "ventilation_per_area": 0.371, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": 96.7, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "Hospital Kitchen Gas", "electric_equipment_per_area": 7.5, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "Hospital Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 150.0, "service_water_heating_area": 10000.0, "service_water_heating_peak_flow_per_area": 0.015, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 924.6539123, "exhaust_fan_pressure_rise": 0.5024115756, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Hospital Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "Lab", "rgb": "204_120_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Lab", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Laboratories", "ventilation_per_area": 1.4, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 2850.0, "service_water_heating_peak_flow_per_area": 0.000701754386, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "Lobby", "rgb": "31_162_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1.03, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.09999999999999999, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "NurseStn", "rgb": "31_162_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "NurseStn", "lighting_per_area": 1.458, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.04, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "OR", "lighting_per_area": 9.745, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Operating rooms", "ventilation_per_area": 0.7, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical ClgSetp", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 600.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Office", "lighting_per_area": 2.395, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.99, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "PatCorridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "PatCorridor", "lighting_per_area": 1.32, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "PatRoom", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "PatRoom", "lighting_per_area": 2.188, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Critical Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Patient rooms", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Critical Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Critical Equip", "heating_setpoint_schedule": "Hospital Critical HtgSetp", "cooling_setpoint_schedule": "Hospital Critical ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 280.0, "service_water_heating_peak_flow_per_area": 0.003571428571, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "PhysTherapy", "rgb": "154_230_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "PhysTherapy", "lighting_per_area": 2.51, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5280.0, "service_water_heating_peak_flow_per_area": 0.0001893939394, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "Radiology", "rgb": "136_78_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Radiology", "lighting_per_area": 2.21, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital Admin Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Radiology", "ventilation_per_area": 0.7, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital Bldg Occ", "occupancy_activity_schedule": "Hospital Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Hospital Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital Admin Equipment", "heating_setpoint_schedule": "Hospital Bldg HtgSetp", "cooling_setpoint_schedule": "Hospital Bldg ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5250.0, "service_water_heating_peak_flow_per_area": 0.0001904761905, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital SWH Extd", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Banquet", "rgb": "230_196_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Banquet", "lighting_per_area": 2.56, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dining rooms", "ventilation_per_area": 0, "ventilation_per_person": 21.2, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 1.0, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 1.0e-05, "exhaust_fan_maximum_flow_rate": 2000.0, "exhaust_schedule": "Always On", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Basement", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Basement", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.5, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Cafe", "lighting_per_area": 2.56, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 67.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 1.22, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp", "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Corridor2", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 1.22, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp", "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "LargeHotel GuestRoom Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel GuestRoom Equip", "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp", "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "GuestRoom2", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "LargeHotel GuestRoom Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel GuestRoom Equip", "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp", "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp", "service_water_heating_peak_flow_rate": 23.743, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.08993560606, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "GuestRoom3", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "LargeHotel GuestRoom Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel GuestRoom Equip", "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp", "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "GuestRoom4", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Dormitory sleeping areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.68, "occupancy_schedule": "LargeHotel GuestRoom Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel GuestRoom Equip", "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp", "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp", "service_water_heating_peak_flow_rate": 11.247, "service_water_heating_area": 264.0, "service_water_heating_peak_flow_per_area": 0.04260227273, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.56, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": 511.0, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "LargeHotel Kitchen Gas", "electric_equipment_per_area": 47.1989, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "LargeHotel Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "LargeHotel Kitchen HtgSetp", "cooling_setpoint_schedule": "LargeHotel Kitchen ClgSetp", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1112.0, "service_water_heating_peak_flow_per_area": 0.1196043165, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": 1.0, "exhaust_fan_power": 698.0, "exhaust_fan_pressure_rise": 1.0e-05, "exhaust_fan_maximum_flow_rate": 94.2477825, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Laundry", "lighting_per_area": 1.14, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Dry Cleaners, Laundries", "ventilation_secondary_space_type": "Commercial Laundry", "ventilation_per_area": 0, "ventilation_per_person": 25, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": 170.0, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "LargeHotel LaundryRoom Gas", "electric_equipment_per_area": 5.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel LaundryRoom Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": 156.6, "service_water_heating_area": 840.0, "service_water_heating_peak_flow_per_area": 0.1864285714, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Pre2004", "exhaust_fan_efficiency": 0.34, "exhaust_fan_power": 87.0, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 500.055681, "exhaust_schedule": "Always On", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1.88, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.7500000000000001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Mechanical", "lighting_per_area": 0.8000000000000002, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Retail", "lighting_per_area": 3.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Retail2", "rgb": "171_222_78", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Retail", "lighting_per_area": 3.54, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "LargeHotel", "lighting_secondary_space_type": "Storage", "lighting_per_area": 0.37, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "LargeHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Shipping and receiving", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.0, "occupancy_schedule": "LargeHotel Common Occ", "occupancy_activity_schedule": "LargeHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "LargeHotel Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.24999999999999997, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "LargeHotel Bldg Equip", "heating_setpoint_schedule": "LargeHotel HtgSetp", "cooling_setpoint_schedule": "LargeHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "MidriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "MidriseApartment Apartment Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 36, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "MidriseApartment Apartment Occ", "occupancy_activity_schedule": "MidriseApartment Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "MidriseApartment Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "MidriseApartment Apartment HtgSetp", "cooling_setpoint_schedule": "MidriseApartment Apartment ClgSetp", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "MidriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.92, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "MidriseApartment Corridor Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "MidriseApartment Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS Pre2004", "heating_setpoint_schedule": "MidriseApartment UnitHeater HtgSP Sch", "cooling_setpoint_schedule": "MidriseApartment UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "MidriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Office", "lighting_per_area": 2.04, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "MidriseApartment Office Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "MidriseApartment Office Occ", "occupancy_activity_schedule": "MidriseApartment Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "MidriseApartment OFFICE Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_Pre2004", "heating_setpoint_schedule": "MidriseApartment Office HtgSetp", "cooling_setpoint_schedule": "MidriseApartment Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": null, "lighting_primary_space_type": null, "lighting_secondary_space_type": null, "lighting_per_area": null, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": "#N/A", "ventilation_per_person": "#N/A", "ventilation_air_changes": "#N/A", "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Small Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "BreakRoom", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "BreakRoom", "lighting_per_area": 2.28, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.63, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "ClosedOffice", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "ClosedOffice", "lighting_per_area": 2.09, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.75, "occupancy_schedule": "Office Work Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.87, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Conference", "lighting_per_area": 2.47, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Office Work Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.29, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 2.85, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "IT_Room", "lighting_per_area": 2.09, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 2.47, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Reception Areas", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "OpenOffice", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "OpenOffice", "lighting_per_area": 2.09, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.25, "occupancy_schedule": "Office Work Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.96, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "PrintRoom", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "PrintRoom", "lighting_per_area": 1.881, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Restroom", "lighting_per_area": 1.71, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Medium Office Bldg Occ", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Stair", "lighting_per_area": 1.14, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Storage", "lighting_per_area": 1.539, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "Vending", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "Vending", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Office Misc Occ", "occupancy_activity_schedule": "Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.85, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "WholeBuilding - Lg Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "WholeBuilding - Lg Office", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Large Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Large Office Bldg Occ", "occupancy_activity_schedule": "Large Office Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Large Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Large Office Bldg Equip", "heating_setpoint_schedule": "Large Office HtgSetp", "cooling_setpoint_schedule": "Large Office ClgSetp", "service_water_heating_peak_flow_rate": 63.9, "service_water_heating_area": 498588.0, "service_water_heating_peak_flow_per_area": 0.0001281619293, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Office SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "WholeBuilding - Md Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "WholeBuilding - Md Office", "lighting_per_area": 1.57, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Medium Office Bldg Occ", "occupancy_activity_schedule": "Medium Office Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Medium Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Medium Office Bldg Equip", "heating_setpoint_schedule": "Medium Office HtgSetp", "cooling_setpoint_schedule": "Medium Office ClgSetp", "service_water_heating_peak_flow_rate": 29.67, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0005532557619, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Medium Office Bldg Swh", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": "WholeBuilding - Sm Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "WholeBuilding - Sm Office", "lighting_per_area": 1.81, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Office Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Small Office Bldg Occ", "occupancy_activity_schedule": "Small Office Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Small Office Infil Quarter On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Small Office Bldg Equip", "heating_setpoint_schedule": "Small Office HtgSetp", "cooling_setpoint_schedule": "Small Office ClgSetp", "service_water_heating_peak_flow_rate": 3.0, "service_water_heating_area": 5502.0, "service_water_heating_peak_flow_per_area": 0.0005452562704, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Office SWH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Anesthesia", "rgb": "204_120_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Anesthesia", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Nursery, Exam", "ventilation_per_area": 0.45, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 8.0, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.009259259259, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 54.520672421626536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "BioHazard", "rgb": "204_120_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "BioHazard", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Bedpan Room", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Cafe", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 92.9, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "CleanWork", "rgb": "204_120_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "CleanWork", "lighting_per_area": 1.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Utility / Workroom", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 4.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Conference", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 46.45, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "DressingRoom", "rgb": "136_78_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "DressingRoom", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "ElevatorPumpRoom", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.1, "electric_equipment_fraction_lost": 0.9, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Exam", "rgb": "136_78_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Exam", "lighting_per_area": 1.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Hall", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Hall", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Hall_infil", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Hall", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "IT_Room", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Telecommunication centers and data entry areas", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Janitor", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Janitor", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.9, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "LockerRoom", "rgb": "169_169_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "LockerRoom", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Lounge", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Lounge", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "MRI", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "MRI", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 53.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Radiology Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 440.0, "service_water_heating_peak_flow_per_area": 0.002272727273, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 166.5909435105255, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "MRI_Control", "rgb": "136_78_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "MRI_Control", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 168.0, "service_water_heating_peak_flow_per_area": 0.005952380952, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 63.6074511585643, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "MedGas", "rgb": "204_120_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "MedGas", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "NurseStation", "rgb": "31_162_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "NurseStation", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "OR", "lighting_per_area": 7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Patient rooms", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 15.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": 23.87, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.0, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "Outpatient Bldg Equip", "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient OR HtgSetp", "cooling_setpoint_schedule": "Outpatient OR ClgSetp", "service_water_heating_peak_flow_rate": 6.0, "service_water_heating_area": 472.0, "service_water_heating_peak_flow_per_area": 0.01271186441, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "PACU", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "PACU", "lighting_per_area": 2.3, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.333, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 316.0, "service_water_heating_peak_flow_per_area": 0.003164556962, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "PhysicalTherapy", "rgb": "154_230_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "PhysicalTherapy", "lighting_per_area": 1.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 946, "service_water_heating_peak_flow_per_area": 0.001057082452, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "PreOp", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "PreOp", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.333, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 6.0, "occupancy_per_area": 9.29, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 263.5, "service_water_heating_peak_flow_per_area": 0.003795066414, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "ProcedureRoom", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "ProcedureRoom", "lighting_per_area": 1.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Patient rooms", "ventilation_per_area": 0.47, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": 15.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 285.0, "service_water_heating_peak_flow_per_area": 0.00350877193, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Reception", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.9, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Soil Work", "rgb": "204_120_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Soil Work", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Soil work Outpatient", "ventilation_per_area": 0.556, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": 10.0, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 79.50931394820536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Stair", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": 1.0, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Toilet", "rgb": "169_169_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Toilet", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.7, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 34.075420263516584, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Outpatient_FirstFlr_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Undeveloped", "rgb": "120_149_230", "lighting_standard": "ASHRAE 90.1-1999", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "Outpatient Bldg Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": "Xray", "rgb": "169_31_159", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Outpatient", "lighting_secondary_space_type": "Xray", "lighting_per_area": 2.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Outpatient Bldg Light", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "Outpatient Bldg Occ", "occupancy_activity_schedule": "Outpatient Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Outpatient Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Outpatient Radiology Equip", "heating_setpoint_schedule": "Outpatient HtgSetp", "cooling_setpoint_schedule": "Outpatient ClgSetp", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 900.0, "service_water_heating_peak_flow_per_area": 0.001111111111, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Cafeteria", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 66.67, "occupancy_schedule": "PrimarySchool Cafeteria Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Classroom", "lighting_per_area": 2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Classroom", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 23.22, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Gym", "lighting_per_area": 1.07, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.9, "occupancy_schedule": "PrimarySchool Gym Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": 302.6, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "PrimarySchool Kitchen Gas", "electric_equipment_per_area": 17.7, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "PrimarySchool Kitchen Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": 100.0, "service_water_heating_area": 1808.0, "service_water_heating_peak_flow_per_area": 0.05530973451, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "PrimarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 572.9644137011418, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "PrimarySchool Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Library", "lighting_per_area": 2.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Libraries", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 21.36, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1.14, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Mechanical", "lighting_per_area": 0.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool HtgSetp", "cooling_setpoint_schedule": "PrimarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "PrimarySchool", "lighting_secondary_space_type": "Restroom", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "PrimarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "PrimarySchool Bldg Occ", "occupancy_activity_schedule": "PrimarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "PrimarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "PrimarySchool Bldg Equip", "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp", "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp", "service_water_heating_peak_flow_rate": 56.5, "service_water_heating_area": 2045.0, "service_water_heating_peak_flow_per_area": 0.02762836186, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "PrimarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 104.17534794566214, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "QuickServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "QuickServiceRestaurant", "lighting_secondary_space_type": "Dining", "lighting_per_area": 3.7, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "QuickServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "QuickServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "QuickServiceRestaurant Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "QuickServiceRestaurant Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 12.0, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp", "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "QuickServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "QuickServiceRestaurant", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 2.24, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "QuickServiceRestaurant Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "QuickServiceRestaurant Bldg Occ", "occupancy_activity_schedule": "QuickServiceRestaurant Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.223, "infiltration_air_changes": null, "infiltration_schedule": "QuickServiceRestaurant Infil Half On", "gas_equipment_per_area": 409.6, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "QuickServiceRestaurant Gas Equip", "electric_equipment_per_area": 28.0, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.3, "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip", "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp Kitchen", "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp Kitchen", "service_water_heating_peak_flow_rate": 40.0, "service_water_heating_area": 1250.0, "service_water_heating_peak_flow_per_area": 0.032, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "QuickServiceRestaurant Bldg Swh", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 575.7279076578998, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "QuickServiceRestaurant Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Retail", "space_type": "Back_Space", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Back_Space", "lighting_per_area": 1.16593, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Retail", "space_type": "Entry", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Entry", "lighting_per_area": 3.36774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail FRONT ENTRY COOLING", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Retail", "space_type": "Point_of_Sale", "rgb": "171_222_78", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Point_of_Sale", "lighting_per_area": 3.36774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Retail", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Retail", "lighting_per_area": 3.36774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Retail Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Clothiers, furniture", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "Retail Bldg Occ", "occupancy_activity_schedule": "Retail Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Retail Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Retail Bldg Equip", "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Auditorium", "rgb": "230_196_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Auditorium", "lighting_per_area": 1.12, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Auditorium", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 92.94, "occupancy_schedule": "SecondarySchool Auditorium Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Cafeteria", "lighting_per_area": 1.34, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria, fast food", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 66.84, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.79, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Kitchen Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Classroom", "lighting_per_area": 2, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Classroom", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 23.22, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.86, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.31, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Gym", "lighting_per_area": 1.06, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 92.94, "occupancy_schedule": "SecondarySchool Gym Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH Showers", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Gym - audience", "rgb": "154_230_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Gym", "lighting_per_area": 1.06, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 27.9, "occupancy_schedule": "SecondarySchool Gym Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH Showers", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Kitchen", "lighting_per_area": 1.56, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Kitchens (cooking)", "ventilation_per_area": 0.47, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.48, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": 354.9, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SecondarySchool Kitchen Gas", "electric_equipment_per_area": 20.65, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SecondarySchool Kitchen Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 2325.0, "service_water_heating_peak_flow_per_area": 0.05720430108, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SecondarySchool Kitchen Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.52, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Libraries", "ventilation_per_area": 0, "ventilation_per_person": 16.95, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 21.34, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Lobby", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Education", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.1, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Mechanical", "lighting_per_area": 0.75, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Office", "lighting_per_area": 1.87, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "SecondarySchool Office Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp", "cooling_setpoint_schedule": "SecondarySchool ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SecondarySchool", "lighting_secondary_space_type": "Restroom", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SecondarySchool Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)", "ventilation_per_area": 0.96, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "SecondarySchool Bldg Occ", "occupancy_activity_schedule": "SecondarySchool Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SecondarySchool Infil", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SecondarySchool Bldg Equip", "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen", "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen", "service_water_heating_peak_flow_rate": 52.2, "service_water_heating_area": 2260.0, "service_water_heating_peak_flow_per_area": 0.02309734513, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SecondarySchool SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 110.36763444376396, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "DOE Ref 1980-2004", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Attic", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Corridor", "lighting_per_area": 0.86, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Elec/MechRoom", "rgb": "41_31_172", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Elec/MechRoom", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 198.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "ElevatorCore", "rgb": "41_31_172", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "ElevatorCore", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Exercise", "rgb": "154_230_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Exercise", "lighting_per_area": 1.37, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Exercise Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Sports and Amusement", "ventilation_secondary_space_type": "Playing floors (gymnasium)", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 31.33, "occupancy_schedule": "SmallHotel Exercise Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.07, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Exercise Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "GuestLounge", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "GuestLounge", "lighting_per_area": 1.31, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel StaffLounge Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.43, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "GuestRoom", "lighting_per_area": 1.74, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel GuestRoom Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Living rooms", "ventilation_per_area": 0.085, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.97, "occupancy_schedule": "SmallHotel GuestRoom Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.33, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel GuestRoom Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": 1.75, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.004985754986, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Laundry", "lighting_per_area": 1.04, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Laundry Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Dry Cleaners, Laundries", "ventilation_secondary_space_type": "Commercial Laundry", "ventilation_per_area": 0, "ventilation_per_person": 25, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SmallHotel Laundry Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": 58.4, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "SmallHotel Laundry Gas", "electric_equipment_per_area": 2.03, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Laundry Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": 67.5, "service_water_heating_area": 1053.0, "service_water_heating_peak_flow_per_area": 0.0641025641, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Mechanical", "lighting_per_area": 0.96, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Corridors and utilities", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Meeting", "rgb": "230_196_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Meeting", "lighting_per_area": 2.13, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Meeting Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Conference rooms", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "SmallHotel Meeting Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Meeting Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Office", "lighting_per_area": 2.01, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Office Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "SmallHotel Office Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Office Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "PublicRestroom", "rgb": "169_169_31", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "PublicRestroom", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.85, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 69.45023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "StaffLounge", "rgb": "31_169_34", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "StaffLounge", "lighting_per_area": 1.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel StaffLounge Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 31.34, "occupancy_schedule": "SmallHotel StaffLounge Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 7.17, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel StaffLounge Equip", "heating_setpoint_schedule": "SmallHotel HtgSetp", "cooling_setpoint_schedule": "SmallHotel ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Stair", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Always On", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SmallHotel", "lighting_secondary_space_type": "Storage", "lighting_per_area": 0.45, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SmallHotel Storage Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SmallHotel Bldg Occ", "occupancy_activity_schedule": "SmallHotel Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SmallHotel Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SmallHotel Bldg Equip", "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "StripMall", "space_type": "Strip mall - type 1", "rgb": "171_222_78", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "StripMall", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 5.5983371904, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "StripMall Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "StripMall Bldg Occ", "occupancy_activity_schedule": "StripMall Activity", "infiltration_per_exterior_area": 0.22303105, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "StripMall Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "StripMall Bldg Equip", "heating_setpoint_schedule": "StripMall HtgSetp", "cooling_setpoint_schedule": "StripMall ClgSetp", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "StripMall", "space_type": "Strip mall - type 2", "rgb": "171_222_78", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "StripMall", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 3.2989869504, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "StripMall Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "StripMall Bldg Occ", "occupancy_activity_schedule": "StripMall Activity", "infiltration_per_exterior_area": 0.22303105, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "StripMall Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "StripMall Bldg Equip", "heating_setpoint_schedule": "StripMall HtgSetp", "cooling_setpoint_schedule": "StripMall ClgSetp", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "StripMall", "space_type": "Strip mall - type 3", "rgb": "171_222_78", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "StripMall", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 2.698833312, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "StripMall Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Basement and street", "ventilation_per_area": 0.3, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "StripMall Bldg Occ", "occupancy_activity_schedule": "StripMall Activity", "infiltration_per_exterior_area": 0.22303105, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "StripMall Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "StripMall Bldg Equip", "heating_setpoint_schedule": "StripMall HtgSetp", "cooling_setpoint_schedule": "StripMall ClgSetp", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SuperMarket", "space_type": "Deli/Bakery", "rgb": "31_169_34", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SuperMarket", "lighting_secondary_space_type": "Deli/Bakery", "lighting_per_area": 5.04, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": 8.53, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "SuperMarket Bldg Equip", "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": 5.0, "service_water_heating_area": 2334.5, "service_water_heating_peak_flow_per_area": 0.00214178625, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SuperMarket SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 520.8767397283107, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SuperMarket_Deli_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SuperMarket", "space_type": "DryStorage", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SuperMarket", "lighting_secondary_space_type": "DryStorage", "lighting_per_area": 0.77, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Shipping and receiving", "ventilation_per_area": 0.15, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SuperMarket", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SuperMarket", "lighting_secondary_space_type": "Office", "lighting_per_area": 2.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "SuperMarket", "space_type": "Sales/Produce", "rgb": "230_196_120", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "SuperMarket", "lighting_secondary_space_type": "Sales/Produce", "lighting_per_area": 5.04, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Specialty Shops", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0, "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.2232, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Warehouse", "space_type": "Bulk", "rgb": "41_31_169", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Bulk", "lighting_per_area": 0.3102962, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "Warehouse Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse Bldg Occ", "occupancy_activity_schedule": "Warehouse Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.2378318, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse HtgSetp BulkStorage", "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Warehouse", "space_type": "Fine", "rgb": "120_149_230", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine", "lighting_per_area": 1.0813914, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "Warehouse Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.05, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse Bldg Occ", "occupancy_activity_schedule": "Warehouse Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse HtgSetp FineStorage", "cooling_setpoint_schedule": "Warehouse ClgSetp FineStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "DOE Ref Pre-1980", "building_type": "Warehouse", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "DOE Ref Pre-1980", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Office", "lighting_per_area": 2.0150669, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "Warehouse Bldg Light", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Offices", "ventilation_secondary_space_type": "Office Space", "ventilation_per_area": 0, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.96, "occupancy_schedule": "Warehouse Bldg Occ", "occupancy_activity_schedule": "Warehouse Activity", "infiltration_per_exterior_area": 0.2232, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.7497275, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse HtgSetp", "cooling_setpoint_schedule": "Warehouse Cooling Setpoint", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "ICC IECC 2015", "building_type": "MidriseApartment", "space_type": "Apartment", "rgb": null, "lighting_standard": null, "lighting_primary_space_type": null, "lighting_secondary_space_type": null, "lighting_per_area": null, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "ICC IECC 2015", "building_type": "MidriseApartment", "space_type": "Corridor", "rgb": null, "lighting_standard": null, "lighting_primary_space_type": null, "lighting_secondary_space_type": null, "lighting_per_area": null, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "ICC IECC 2015", "building_type": "MidriseApartment", "space_type": "Office", "rgb": null, "lighting_standard": null, "lighting_primary_space_type": null, "lighting_secondary_space_type": null, "lighting_per_area": null, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "NECB 2011", "building_type": "Automotive facility", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Automotive facility", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.817539948, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Automotive facility", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.226, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002137, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Automotive Area", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Convention centre", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Convention centre", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.077666295, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Convention centre", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.147, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 11.61, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001781, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Courthouse", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Courthouse", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.049795615, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Courthouse", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.091, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.19, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0019, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Dining - bar/lounge", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Dining - bar/lounge", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.994054255, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Dining - bar/lounge", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.005462, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Dining - cafeteria", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Dining - cafeteria", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.901151988, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Dining - cafeteria", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.005462, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Dining - family", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Dining - family", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Dining - family", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.005462, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Dormitory", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Dormitory", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.613154961, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Dormitory", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.075, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.007915, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Sleeping Area", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Exercise centre", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Exercise centre", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.882571535, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Exercise centre", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.246, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004274, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Fire station", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Fire station", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.706057228, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Fire station", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.148, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.007599, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Automotive Area", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Gymnasium", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Gymnasium", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.003344482, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Gymnasium", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.246, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004274, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Health-care clinic", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Health-care clinic", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.873281308, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Health-care clinic", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.45, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002137, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Hospital", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.207729469, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Hospital", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.45, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002137, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Hotel", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Hotel", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.003344482, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Hotel", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.079, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.009498, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Residential/Accomodation Area", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Library", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Library", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.179858789, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Library", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.143, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002137, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Historical Collections Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Manufacturing facility", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Manufacturing facility", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.105536975, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Manufacturing facility", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.211, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Industrial Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Motel", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Motel", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.882571535, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Motel", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.079, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.009498, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Residential/Accomodation Area", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Motion picture theatre", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Motion picture theatre", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.826830175, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Motion picture theatre", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.118, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 11.61, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001781, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Multi-unit residential", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Multi-unit residential", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.603864734, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Multi-unit residential", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.068, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.55, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.003958, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Residential/Accomodation Area", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Museum", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Museum", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.059085842, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Museum", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.095, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Historical Collections Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Office", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.901151988, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Office", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.079, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00171, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Parking garage", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Parking garage", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.25083612, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Parking garage", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.061, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.09, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Automotive Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Penitentiary", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Penitentiary", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.966183575, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Penitentiary", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.075, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.006332, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Sleeping Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Performing arts theatre", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Performing arts theatre", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.393534002, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Performing arts theatre", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.118, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 11.61, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001781, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Police station", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Police station", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.956893348, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Police station", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.079, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00171, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Post office", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Post office", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.873281308, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Post office", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.148, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00171, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Religious", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Religious", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.049795615, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Religious", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.153, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Retail", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.402824229, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.083, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000633, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "School/university", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "School/university", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.994054255, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "School/university", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.147, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 11.61, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.003562, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "- undefined -", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "- undefined -", "lighting_per_area": 0.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "- undefined -", "necb_schedule_type": "- undefined -" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Atrium - H < 13m", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Atrium - H < 13m", "lighting_per_area": 0.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Atrium - H < 13m", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Atrium - H > 13m", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Atrium - H > 13m", "lighting_per_area": 0.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Atrium - H > 13m", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Audience - auditorium", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Audience - auditorium", "lighting_per_area": 0.789669268, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Audience - auditorium", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002839298, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Audience - motion picture", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Audience - motion picture", "lighting_per_area": 1.142697882, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Audience - motion picture", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002839298, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Audience - performance arts", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Audience - performance arts", "lighting_per_area": 2.434039391, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Audience - performance arts", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 12.39, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001893375, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Automotive - repair", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Automotive - repair", "lighting_per_area": 0.668896321, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Automotive - repair", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Automotive Area", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Bank - banking and offices", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Bank - banking and offices", "lighting_per_area": 1.384243776, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Bank - banking and offices", "ventilation_per_area": 0.173, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001142515, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Classroom/lecture/training", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Classroom/lecture/training", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Classroom/lecture/training", "ventilation_per_area": 0.548, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 12.39, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004120874, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Conf./meet./multi-purpose", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Conf./meet./multi-purpose", "lighting_per_area": 1.226309922, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Conf./meet./multi-purpose", "ventilation_per_area": 0.31, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004286783, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Convention centre - audience", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Convention centre - audience", "lighting_per_area": 0.817539948, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Convention centre - audience", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002839298, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Convention centre - exhibit", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Convention centre - exhibit", "lighting_per_area": 1.449275362, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Convention centre - exhibit", "ventilation_per_area": 0.17, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002839298, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-A", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. < 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-B", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. < 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-C", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. < 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-D", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. < 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-E", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. < 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-F", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. < 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-G", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. < 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-H", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. < 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. < 2.4m wide-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-I", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. < 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-A", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. >= 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-B", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. >= 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-C", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. >= 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-D", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. >= 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-E", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. >= 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-F", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. >= 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-G", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. >= 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-H", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. >= 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Corr. >= 2.4m wide-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-I", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Corr. >= 2.4m wide", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Courthouse - cell", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Courthouse - cell", "lighting_per_area": 1.365663322, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Courthouse - cell", "ventilation_per_area": 0.245, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.006180727, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Sleeping Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Courthouse - chambers", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Courthouse - chambers", "lighting_per_area": 1.170568562, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Courthouse - chambers", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Courthouse - courtroom", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Courthouse - courtroom", "lighting_per_area": 1.718691936, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Courthouse - courtroom", "ventilation_per_area": 0.41, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002839298, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Dining - bar lounge/leisure", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Dining - bar lounge/leisure", "lighting_per_area": 1.309921962, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Dining - bar lounge/leisure", "ventilation_per_area": 0.705, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004272865, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Dining - family space", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Dining - family space", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Dining - family space", "ventilation_per_area": 0.705, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.005692514, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Dining - other", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Dining - other", "lighting_per_area": 0.650315868, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Dining - other", "ventilation_per_area": 0.705, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.005692514, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Dormitory - living quarters", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Dormitory - living quarters", "lighting_per_area": 0.380899294, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Dormitory - living quarters", "ventilation_per_area": 0.11, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.009507954, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Sleeping Area", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Dress./fitt. - performance arts", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Dress./fitt. - performance arts", "lighting_per_area": 0.399479747, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Dress./fitt. - performance arts", "ventilation_per_area": 0.233, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000631634, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Dwelling Unit(s)", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Dwelling Unit(s)", "lighting_per_area": 0.464511334, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Dwelling Unit(s)", "ventilation_per_area": 0.068, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.55, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.003961647, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Residential/Accomodation Area", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Electrical/Mechanical-sch-A", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Electrical/Mechanical", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Electrical/Mechanical-sch-B", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Electrical/Mechanical", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Electrical/Mechanical-sch-C", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Electrical/Mechanical", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Electrical/Mechanical-sch-D", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Electrical/Mechanical", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Electrical/Mechanical-sch-E", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Electrical/Mechanical", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Electrical/Mechanical-sch-F", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Electrical/Mechanical", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Electrical/Mechanical-sch-G", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Electrical/Mechanical", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Electrical/Mechanical-sch-H", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Electrical/Mechanical", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Electrical/Mechanical-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Electrical/Mechanical-sch-I", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Electrical/Mechanical", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Fire station - engine room", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Fire station - engine room", "lighting_per_area": 0.557413601, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Fire station - engine room", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.006180727, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Automotive Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Fire station - quarters", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Fire station - quarters", "lighting_per_area": 0.315867707, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Fire station - quarters", "ventilation_per_area": 0.16, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.009507954, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Residential/Accomodation Area", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Food preparation", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Food preparation", "lighting_per_area": 0.994054255, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Food preparation", "ventilation_per_area": 0.27, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002849321, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Food preparation - vented", "rgb": "255_255_256", "lighting_standard": "NECB 2012", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Food preparation", "lighting_per_area": 0.994054255, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2012", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Food preparation", "ventilation_per_area": 0.27, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002849321, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area - vented", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Gym - audience", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Gym - audience", "lighting_per_area": 0.427350427, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Gym - audience", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002839298, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Gym - fitness", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Gym - fitness", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Gym - fitness", "ventilation_per_area": 0.86, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00854573, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Gym - play", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Gym - play", "lighting_per_area": 1.198439242, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Gym - play", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1393534, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00854573, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - emergency", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - emergency", "lighting_per_area": 2.257525084, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - emergency", "ventilation_per_area": 0.6, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004277465, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - exam", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - exam", "lighting_per_area": 1.662950576, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - exam", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - laundry/washing", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - laundry/washing", "lighting_per_area": 0.743218135, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - laundry/washing", "ventilation_per_area": 0.45, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.858045336, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001428144, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - lounge/recreation", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - lounge/recreation", "lighting_per_area": 1.068376068, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - lounge/recreation", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002853216, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - medical supply", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - medical supply", "lighting_per_area": 1.272761055, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - medical supply", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - nursery", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - nursery", "lighting_per_area": 0.882571535, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - nursery", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - nurses' station", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - nurses' station", "lighting_per_area": 0.873281308, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - nurses' station", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001072849, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - operating room", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - operating room", "lighting_per_area": 1.885916016, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - operating room", "ventilation_per_area": 0.9, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.007133752, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - patient room", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - patient room", "lighting_per_area": 0.622445188, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - patient room", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - pharmacy", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - pharmacy", "lighting_per_area": 1.142697882, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - pharmacy", "ventilation_per_area": 0.45, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001072849, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - physical therapy", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - physical therapy", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - physical therapy", "ventilation_per_area": 0.45, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001072849, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - radiology/imaging", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - radiology/imaging", "lighting_per_area": 1.319212189, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - radiology/imaging", "ventilation_per_area": 0.45, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital - recovery", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital - recovery", "lighting_per_area": 1.151988109, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital - recovery", "ventilation_per_area": 0.9, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004277465, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-A", "lighting_per_area": 1.086956522, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. < 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-B", "lighting_per_area": 1.086956522, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. < 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-C", "lighting_per_area": 1.086956522, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. < 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-D", "lighting_per_area": 1.086956522, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. < 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-E", "lighting_per_area": 1.086956522, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. < 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-F", "lighting_per_area": 1.086956522, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. < 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-G", "lighting_per_area": 1.086956522, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. < 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-H", "lighting_per_area": 1.086956522, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. < 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. < 2.4m-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-I", "lighting_per_area": 1.086956522, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. < 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-A", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. >= 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-B", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. >= 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-C", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. >= 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-D", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. >= 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-E", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. >= 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-F", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. >= 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-G", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. >= 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-H", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. >= 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hospital corr. >= 2.4m-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-I", "lighting_per_area": 0.891861761, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hospital corr. >= 2.4m", "ventilation_per_area": 0.15, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hotel/Motel - dining", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hotel/Motel - dining", "lighting_per_area": 0.817539948, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hotel/Motel - dining", "ventilation_per_area": 0.705, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.005455906, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hotel/Motel - lobby", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hotel/Motel - lobby", "lighting_per_area": 1.059085842, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hotel/Motel - lobby", "ventilation_per_area": 0.285, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001419649, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hotel/Motel - rooms", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hotel/Motel - rooms", "lighting_per_area": 1.105536975, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hotel/Motel - rooms", "ventilation_per_area": 0.11, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.01140843, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Residential/Accomodation Area", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hway lodging - dining", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hway lodging - dining", "lighting_per_area": 0.882571535, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hway lodging - dining", "ventilation_per_area": 0.705, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.005455906, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Hway lodging - rooms", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Hway lodging - rooms", "lighting_per_area": 0.752508361, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Hway lodging - rooms", "ventilation_per_area": 0.11, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.01140843, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Residential/Accomodation Area", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Lab - classrooms", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Lab - classrooms", "lighting_per_area": 1.597918989, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Lab - classrooms", "ventilation_per_area": 0.43, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004277465, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Lab - research", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Lab - research", "lighting_per_area": 2.192493497, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Lab - research", "ventilation_per_area": 0.43, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004277465, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Hospital Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Library - cataloging", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Library - cataloging", "lighting_per_area": 0.724637681, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Library - cataloging", "ventilation_per_area": 0.17, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Library - reading", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Library - reading", "lighting_per_area": 0.929022668, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Library - reading", "ventilation_per_area": 0.17, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Library - stacks", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Library - stacks", "lighting_per_area": 2.12746191, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Library - stacks", "ventilation_per_area": 0.17, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Lobby - elevator", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Lobby - elevator", "lighting_per_area": 0.641025641, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Lobby - elevator", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Lobby - motion picture", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Lobby - motion picture", "lighting_per_area": 0.520252694, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Lobby - motion picture", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Lobby - other", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Lobby - other", "lighting_per_area": 0.901151988, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Lobby - other", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Lobby - performance arts", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Lobby - performance arts", "lighting_per_area": 1.997398737, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Lobby - performance arts", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-*-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-*-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-*-Electric-Equipment", "heating_setpoint_schedule": "NECB-*-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-*-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-*-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-*-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "*" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room-sch-A", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room-sch-B", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room-sch-C", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room-sch-D", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room-sch-E", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room-sch-F", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room-sch-G", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room-sch-H", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Locker room-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Locker room-sch-I", "lighting_per_area": 0.910442215, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Locker room", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Lounge/recreation", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Lounge/recreation", "lighting_per_area": 0.873281308, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Lounge/recreation", "ventilation_per_area": 0.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002853216, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - 7.5 <= bay H <= 15m", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - 7.5 <= bay H <= 15m", "lighting_per_area": 1.226309922, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - 7.5 <= bay H <= 15m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425822, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Industrial Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - bay H < 7.5m", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - bay H < 7.5m", "lighting_per_area": 1.189149015, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - bay H < 7.5m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425822, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Industrial Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - bay H > 15m", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - bay H > 15m", "lighting_per_area": 1.049795615, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - bay H > 15m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425822, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Industrial Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-A", "lighting_per_area": 0.510962467, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. < 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-B", "lighting_per_area": 0.510962467, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. < 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-C", "lighting_per_area": 0.510962467, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. < 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-D", "lighting_per_area": 0.510962467, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. < 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-E", "lighting_per_area": 0.510962467, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. < 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-F", "lighting_per_area": 0.510962467, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. < 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-G", "lighting_per_area": 0.510962467, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. < 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-H", "lighting_per_area": 0.510962467, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. < 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. < 2.4m-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-I", "lighting_per_area": 0.510962467, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. < 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-A", "lighting_per_area": 0.408769974, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-B", "lighting_per_area": 0.408769974, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-C", "lighting_per_area": 0.408769974, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-D", "lighting_per_area": 0.408769974, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-E", "lighting_per_area": 0.408769974, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-F", "lighting_per_area": 0.408769974, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-G", "lighting_per_area": 0.408769974, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-H", "lighting_per_area": 0.408769974, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - corr. >= 2.4m-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-I", "lighting_per_area": 0.408769974, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - detailed", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - detailed", "lighting_per_area": 1.291341509, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - detailed", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425822, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Industrial Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Mfg - equipment", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Mfg - equipment", "lighting_per_area": 1.235600149, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Mfg - equipment", "ventilation_per_area": 0.25, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425822, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Industrial Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Museum - exhibition", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Museum - exhibition", "lighting_per_area": 1.049795615, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Museum - exhibition", "ventilation_per_area": 0.36, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.005706432, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Historical Collections Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Museum - restoration", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Museum - restoration", "lighting_per_area": 1.021924935, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Museum - restoration", "ventilation_per_area": 0.17, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001191281, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Historical Collections Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Office - enclosed", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Office - enclosed", "lighting_per_area": 1.105536975, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Office - enclosed", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Office - open plan", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Office - open plan", "lighting_per_area": 1.021924935, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Office - open plan", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Parking garage space", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Parking garage space", "lighting_per_area": 0.185804534, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Parking garage space", "ventilation_per_area": 0.5, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.09, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Automotive Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Penitentiary - audience", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Penitentiary - audience", "lighting_per_area": 0.427350427, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Penitentiary - audience", "ventilation_per_area": 0.41, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002839298, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Penitentiary - classroom", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Penitentiary - classroom", "lighting_per_area": 1.337792642, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Penitentiary - classroom", "ventilation_per_area": 0.548, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 12.39, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.464511334, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004120874, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Penitentiary - dining", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Penitentiary - dining", "lighting_per_area": 1.068376068, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Penitentiary - dining", "ventilation_per_area": 0.705, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.005692514, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Supermarket/Food Services Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Post office sorting", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Post office sorting", "lighting_per_area": 0.938312895, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Post office sorting", "ventilation_per_area": 0.173, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002138732, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Religious - audience", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Religious - audience", "lighting_per_area": 1.690821256, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Religious - audience", "ventilation_per_area": 0.66, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001419649, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Religious - fellowship hall", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Religious - fellowship hall", "lighting_per_area": 0.641025641, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Religious - fellowship hall", "ventilation_per_area": 0.66, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004286783, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Religious - pulpit/choir", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Religious - pulpit/choir", "lighting_per_area": 1.690821256, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Religious - pulpit/choir", "ventilation_per_area": 0.66, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001419649, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Retail - dressing/fitting", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Retail - dressing/fitting", "lighting_per_area": 0.873281308, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Retail - dressing/fitting", "ventilation_per_area": 0.233, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000631634, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Retail - mall concourse", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Retail - mall concourse", "lighting_per_area": 1.096246748, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Retail - mall concourse", "ventilation_per_area": 0.36, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000710589, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Retail - sales", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Retail - sales", "lighting_per_area": 1.681531029, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Retail - sales", "ventilation_per_area": 0.233, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000631634, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Sales area", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Sales area", "lighting_per_area": 1.681531029, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Sales area", "ventilation_per_area": 0.233, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000631634, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Sports arena - audience", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Sports arena - audience", "lighting_per_area": 0.427350427, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Sports arena - audience", "ventilation_per_area": 1.185, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002839298, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Sports arena - court c1", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Sports arena - court c1", "lighting_per_area": 3.010033445, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Sports arena - court c1", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1393534, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00854573, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Sports arena - court c2", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Sports arena - court c2", "lighting_per_area": 1.923076923, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Sports arena - court c2", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1393534, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00854573, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Sports arena - court c3", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Sports arena - court c3", "lighting_per_area": 1.198439242, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Sports arena - court c3", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1393534, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00854573, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Sports arena - court c4", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Sports arena - court c4", "lighting_per_area": 0.724637681, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Sports arena - court c4", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1393534, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00854573, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Sports arena - ring", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Sports arena - ring", "lighting_per_area": 2.675585284, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Sports arena - ring", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 18.58, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1393534, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00854573, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Stairway-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Stairway-sch-A", "lighting_per_area": 0.687476774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Stairway", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Stairway-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Stairway-sch-B", "lighting_per_area": 0.687476774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Stairway", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Stairway-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Stairway-sch-C", "lighting_per_area": 0.687476774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Stairway", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Stairway-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Stairway-sch-D", "lighting_per_area": 0.687476774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Stairway", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Stairway-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Stairway-sch-E", "lighting_per_area": 0.687476774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Stairway", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Stairway-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Stairway-sch-F", "lighting_per_area": 0.687476774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Stairway", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Stairway-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Stairway-sch-G", "lighting_per_area": 0.687476774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Stairway", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Stairway-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Stairway-sch-H", "lighting_per_area": 0.687476774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Stairway", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Stairway-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Stairway-sch-I", "lighting_per_area": 0.687476774, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Stairway", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.46, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Storage area", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Storage area", "lighting_per_area": 0.631735414, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Storage area", "ventilation_per_area": 0.07, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00142675, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Storage area - refrigerated", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Storage area", "lighting_per_area": 0.631735414, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Storage area", "ventilation_per_area": 0.07, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00142675, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area - refrigerated", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Transp. baggage", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Transp. baggage", "lighting_per_area": 0.761798588, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Transp. baggage", "ventilation_per_area": 0.173, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001546575, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Transp. concourse", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Transp. concourse", "lighting_per_area": 0.362318841, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Transp. concourse", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.65, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.003089824, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Transp. counter", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Transp. counter", "lighting_per_area": 1.077666295, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Transp. counter", "ventilation_per_area": 0.173, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.232255667, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.003089824, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Transp. seating", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Transp. seating", "lighting_per_area": 0.538833148, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Transp. seating", "ventilation_per_area": 0.81, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001546575, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Warehouse - fine", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Warehouse - fine", "lighting_per_area": 0.947603122, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Warehouse - fine", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.86, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00061863, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Warehouse - fine - refrigerated", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Warehouse - fine", "lighting_per_area": 0.947603122, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Warehouse - fine", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.86, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00061863, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area - refrigerated", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Warehouse - med/blk", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Warehouse - med/blk", "lighting_per_area": 0.594574508, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Warehouse - med/blk", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000309315, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Warehouse - med/blk - refrigerated", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Warehouse - med/blk", "lighting_per_area": 0.594574508, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Warehouse - med/blk", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000309315, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area - refrigerated", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Warehouse - med/blk2", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Warehouse - med/blk2", "lighting_per_area": 0.947603122, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Warehouse - med/blk2", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000309315, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Warehouse - med/blk2 - refrigerated", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Warehouse - med/blk2", "lighting_per_area": 0.947603122, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Warehouse - med/blk2", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.93, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.000309315, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area - refrigerated", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Washroom-sch-A", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Washroom-sch-A", "lighting_per_area": 0.975473802, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Washroom", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Washroom-sch-B", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Washroom-sch-B", "lighting_per_area": 0.975473802, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Washroom", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Washroom-sch-C", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Washroom-sch-C", "lighting_per_area": 0.975473802, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-C-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Washroom", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-C-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-C-Electric-Equipment", "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-C-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-C-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "C" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Washroom-sch-D", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Washroom-sch-D", "lighting_per_area": 0.975473802, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Washroom", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Washroom-sch-E", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Washroom-sch-E", "lighting_per_area": 0.975473802, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-E-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Washroom", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-E-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-E-Electric-Equipment", "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-E-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-E-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "E" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Washroom-sch-F", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Washroom-sch-F", "lighting_per_area": 0.975473802, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-F-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Washroom", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-F-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-F-Electric-Equipment", "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-F-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-F-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "F" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Washroom-sch-G", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Washroom-sch-G", "lighting_per_area": 0.975473802, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-G-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Washroom", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-G-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-G-Electric-Equipment", "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-G-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-G-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "G" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Washroom-sch-H", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Washroom-sch-H", "lighting_per_area": 0.975473802, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Washroom", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Washroom-sch-I", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Washroom-sch-I", "lighting_per_area": 0.975473802, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-I-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Washroom", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-I-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-I-Electric-Equipment", "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": 0.0, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.0, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-I-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-I-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Wildcard", "necb_schedule_type": "I" }, { "template": "NECB 2011", "building_type": "Space Function", "space_type": "Workshop space", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Space Function", "lighting_secondary_space_type": "Workshop space", "lighting_per_area": 1.588628763, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Space Function", "ventilation_secondary_space_type": "Workshop space", "ventilation_per_area": 0.38, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425822, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Industrial Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Sports arena", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Sports arena", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.780379041, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-B-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Sports arena", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.13, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 9.29, "occupancy_schedule": "NECB-B-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-B-Electric-Equipment", "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.004274, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-B-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-B-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "B" }, { "template": "NECB 2011", "building_type": "Town hall", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Town hall", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.919732441, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-D-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Town hall", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.079, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.72, "occupancy_schedule": "NECB-D-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.696767001, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-D-Electric-Equipment", "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.00171, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-D-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-D-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Assembly Area", "necb_schedule_type": "D" }, { "template": "NECB 2011", "building_type": "Transportation", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Transportation", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.771088815, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-H-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Transportation", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.106, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.19, "occupancy_schedule": "NECB-H-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-H-Electric-Equipment", "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.002058, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-H-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-H-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "General Area", "necb_schedule_type": "H" }, { "template": "NECB 2011", "building_type": "Warehouse", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Warehouse", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.061, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.06, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 9.5e-05, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Warehouse - refrigerated", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 0.659606094, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Warehouse", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.061, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.06, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.092902267, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 9.5e-05, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Warehouse Area - refrigerated", "necb_schedule_type": "A" }, { "template": "NECB 2011", "building_type": "Workshop", "space_type": "WholeBuilding", "rgb": "255_255_255", "lighting_standard": "NECB 2011", "lighting_primary_space_type": "Workshop", "lighting_secondary_space_type": "WholeBuilding", "lighting_per_area": 1.198439242, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.5, "lighting_fraction_visible": 0.2, "lighting_schedule": "NECB-A-Lighting", "ventilation_standard": "NECB 2011", "ventilation_primary_space_type": "Workshop", "ventilation_secondary_space_type": "WholeBuilding", "ventilation_per_area": 0.211, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.1, "occupancy_schedule": "NECB-A-Occupancy", "occupancy_activity_schedule": "NECB-Activity", "infiltration_per_exterior_area": 0.049225, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929022668, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "NECB-A-Electric-Equipment", "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating", "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": 0.001425, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "NECB-A-Service Water Heating", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "NECB-A-FAN", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": "Industrial Area", "necb_schedule_type": "A" }, { "template": "OEESC 2014", "building_type": "FullServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "FullServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_DINING_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Restaurant dining rooms", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.032, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "FullServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH", "gas_equipment_per_area": 205.81, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH", "electric_equipment_per_area": 37.53, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1501.0, "service_water_heating_peak_flow_per_area": 0.08860759494, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.94, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "ER_Exam", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "ER_NurseStn", "rgb": "31_162_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.85, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "ER_Trauma", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 0.192, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "ER_Triage", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 0.192, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "ER Waiting Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 300.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "ICU_NurseStn", "rgb": "31_162_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.85, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Critical and Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "ICU_Open", "rgb": "78_167_222", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 0.74, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Critical and Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "ICU_PatRm", "rgb": "78_167_222", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.59, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Critical and Intensive Care", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": 51.16, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "electric_equipment_per_area": 7.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 150.0, "service_water_heating_area": 10000.0, "service_water_heating_peak_flow_per_area": 0.015, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 924.6539122990511, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "Lab", "rgb": "204_120_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Laboratory", "lighting_secondary_space_type": "General", "lighting_per_area": 1.4, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Science laboratories", "ventilation_per_area": 0.18, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 2850.0, "service_water_heating_peak_flow_per_area": 0.000701754386, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "Lobby", "rgb": "31_162_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "NurseStn", "rgb": "31_162_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.85, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.333, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 0.192, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Surgery and Critical Care", "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 3, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.92, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 600.0, "service_water_heating_peak_flow_per_area": 0.003333333333, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 6.99, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "PatCorridor", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.94, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "PatRoom", "rgb": "78_167_222", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.59, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "AIA 2001", "ventilation_primary_space_type": "Nursing", "ventilation_secondary_space_type": "Patient Room", "ventilation_per_area": "", "ventilation_per_person": "", "ventilation_air_changes": 2, "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 280.0, "service_water_heating_peak_flow_per_area": 0.003571428571, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "PhysTherapy", "rgb": "154_230_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5280.0, "service_water_heating_peak_flow_per_area": 0.0001893939394, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Hospital", "space_type": "Radiology", "rgb": "136_78_222", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 0.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Medical procedure", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "Hospital BLDG_OCC_SCH", "occupancy_activity_schedule": "Hospital ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Hospital INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH", "heating_setpoint_schedule": "Hospital HTGSETP_SCH", "cooling_setpoint_schedule": "Hospital CLGSETP_SCH", "service_water_heating_peak_flow_rate": 1.0, "service_water_heating_area": 5250.0, "service_water_heating_peak_flow_per_area": 0.0001904761905, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Banquet", "rgb": "230_196_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0254576, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 6.301, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 1.0, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 0.0, "exhaust_fan_maximum_flow_rate": 2000.0, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Basement", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Multipurpose assembly", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH_2010", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.41, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0192416, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "GuestRoom", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "General", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.57, "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.627, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva", "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 1.25, "service_water_heating_area": 420.0, "service_water_heating_peak_flow_per_area": 0.002976190476, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch", "exhaust_fan_efficiency": "\n", "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0513, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": 767.0, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH", "electric_equipment_per_area": 47.2, "electric_equipment_fraction_latent": 0.2, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.1, "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 1112.0, "service_water_heating_peak_flow_per_area": 0.1196043165, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.385, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 4000.0, "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule", "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.52, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coinoperated laundries", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": 170.0, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "electric_equipment_per_area": 5.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": 156.6, "service_water_heating_area": 840.0, "service_water_heating_peak_flow_per_area": 0.1864285714, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch", "exhaust_fan_efficiency": 0.385, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": 125.0, "exhaust_fan_maximum_flow_rate": 500.0, "exhaust_schedule": "HotelLarge Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 1.1, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "LargeHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH_2010", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.25, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH", "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH", "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "MidriseApartment", "space_type": "Apartment", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2004", "lighting_primary_space_type": "MidriseApartment", "lighting_secondary_space_type": "Apartment", "lighting_per_area": 0.36, "lighting_per_person": null, "additional_lighting_per_area": 0.09, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_APT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Apartment", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": 0.35, "minimum_total_air_changes": null, "occupancy_per_area": 2.63, "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_APT_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": 3.48, "service_water_heating_area": 950.0, "service_water_heating_peak_flow_per_area": 0.003663157895, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "MidriseApartment", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.41, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "ApartmentMidRise All Off", "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_COR_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "MidriseApartment", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": 1.11, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Living rooms", "ventilation_per_area": 0.085, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.11, "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH", "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.6196632768, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2010_2013", "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "BreakRoom", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 4.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "ClosedOffice", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.75, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.64, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.41, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.16, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.27, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.56, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07000000000000005, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "OpenOffice", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Open Plan", "lighting_secondary_space_type": "General", "lighting_per_area": 0.93, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.25, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.71, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "PrintRoom", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.79, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.07, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_per_area": 0.49, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "Vending", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.41, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.4, "lighting_fraction_radiant": 0.4, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.85, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "WholeBuilding - Lg Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.74973447, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 27.7, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0005165212203, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "WholeBuilding - Md Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0595, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2013", "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 27.7, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.0005165212203, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Office", "space_type": "WholeBuilding - Sm Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Office", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Whole Building", "ventilation_per_area": 0.085, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.6, "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH", "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.63, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH", "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 3.0, "service_water_heating_area": 5502.0, "service_water_heating_peak_flow_per_area": 0.0005452562704, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Anesthesia", "rgb": "204_120_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Treatment / Examination", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.01851851852, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 54.520672421626536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "BioHazard", "rgb": "204_120_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Cafe", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 99.89, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "CleanWork", "rgb": "204_120_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Utility / Workroom", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Conference", "rgb": "230_196_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 49.95, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "DressingRoom", "rgb": "136_78_222", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Elec/MechRoom", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 5.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "ElevatorPumpRoom", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.1, "electric_equipment_fraction_lost": 0.9, "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_ADD_DF", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Exam", "rgb": "136_78_222", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Hall", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "For Hospital", "lighting_per_area": 0.94, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "IT_Room", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Telephone/data entry", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Janitor", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH_20102013", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "LockerRoom", "rgb": "169_169_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Healthcare Facility", "lighting_per_area": 0.71, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Lounge", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "For Healthcare Facility", "lighting_per_area": 0.71, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.01, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "MRI", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 0.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 440.0, "service_water_heating_peak_flow_per_area": 0.004545454545, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 166.5909435105255, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "MRI_Control", "rgb": "136_78_222", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 0.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 168.0, "service_water_heating_peak_flow_per_area": 0.0119047619, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 63.6074511585643, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "MedGas", "rgb": "204_120_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "NurseStation", "rgb": "31_162_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Nurse Station", "lighting_per_area": 0.85, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "OR", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Operating Room", "lighting_per_area": 0.192, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Operating rooms outpatient", "ventilation_per_area": 0.5, "ventilation_per_person": 30, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": 23.87, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.0, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH", "electric_equipment_per_area": 4.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH", "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH", "service_water_heating_peak_flow_rate": 12.0, "service_water_heating_area": 472.0, "service_water_heating_peak_flow_per_area": 0.02542372881, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH_20102013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "PACU", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Recovery", "lighting_per_area": 0.74, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 108.0, "service_water_heating_peak_flow_per_area": 0.01851851852, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "PhysicalTherapy", "rgb": "154_230_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Physical Therapy", "lighting_per_area": 0.8, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Physical therapy", "ventilation_per_area": "", "ventilation_per_person": 15, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.5, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 946.0, "service_water_heating_peak_flow_per_area": 0.002114164905, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "PreOp", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Patient Room", "lighting_per_area": 0.59, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient", "ventilation_per_area": 0.533, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 263.5, "service_water_heating_peak_flow_per_area": 0.007590132827, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "ProcedureRoom", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes", "ventilation_secondary_space_type": "Procedure Room Outpatient", "ventilation_per_area": 0.8, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 3.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 285.0, "service_water_heating_peak_flow_per_area": 0.00701754386, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Reception", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Main entry lobbies", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 29.97, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Soil Work", "rgb": "204_120_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Exam/Treatment", "lighting_per_area": 1.26, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "Clean Linen Storage", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 79.50931394820536, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_per_area": 0.49, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Toilet", "rgb": "169_169_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-1999", "ventilation_primary_space_type": "Public Spaces", "ventilation_secondary_space_type": "Public restrooms", "ventilation_per_area": 0, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.31, "exhaust_fan_power": 34.075420263516584, "exhaust_fan_pressure_rise": 1.0, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "OutPatientHealthCare Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Undeveloped", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2004", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.7, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Outpatient", "space_type": "Xray", "rgb": "169_31_159", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Healthcare Facility", "lighting_secondary_space_type": "Radiology/Imaging", "lighting_per_area": 0.35, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH", "ventilation_standard": "GGHC v2.2", "ventilation_primary_space_type": "Health Care", "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 20.02, "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH", "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "OutPatientHealthCare INFIL_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE", "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM", "service_water_heating_peak_flow_rate": 2.0, "service_water_heating_area": 900.0, "service_water_heating_peak_flow_per_area": 0.002222222222, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.36, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.23, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (ages 5-8)", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 25.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.41, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 13.93, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": 453.7, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 17.7, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 100.0, "service_water_heating_area": 1808.0, "service_water_heating_peak_flow_per_area": 0.05530973451, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 572.9644137011418, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.39, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "PrimarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 56.5, "service_water_heating_area": 2045.0, "service_water_heating_peak_flow_per_area": 0.02762836186, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 104.17534794566214, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "QuickServiceRestaurant", "space_type": "Attic", "rgb": "120_149_230", "lighting_standard": "ASHRAE 189.1-2009", "lighting_primary_space_type": "Attics", "lighting_secondary_space_type": "General", "lighting_per_area": 0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_schedule": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "QuickServiceRestaurant", "space_type": "Dining", "rgb": "31_169_34", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "For Family Dining", "lighting_per_area": 0.89, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 70.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 10.85, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "QuickServiceRestaurant", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2010_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH", "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH", "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.112, "infiltration_air_changes": null, "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL", "gas_equipment_per_area": 250.86, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH", "electric_equipment_per_area": 25.166, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.3, "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 40.0, "service_water_heating_area": 1250.0, "service_water_heating_peak_flow_per_area": 0.032, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 575.7279076578998, "exhaust_fan_pressure_rise": 0.502411575562701, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "RestaurantFastFood Hours_of_operation", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Retail", "space_type": "Back_Space", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Retail", "space_type": "Entry", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Retail", "space_type": "Point_of_Sale", "rgb": "171_222_78", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Retail", "space_type": "Retail", "rgb": "171_222_78", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales", "ventilation_per_area": 0.12, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.0, "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010", "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.3, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH", "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Auditorium", "rgb": "230_196_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Audience/Seating Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.79, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Public Assembly Spaces", "ventilation_secondary_space_type": "Auditorium seating area", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 150.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Cafeteria", "rgb": "31_169_34", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Dining Area", "lighting_secondary_space_type": "General", "lighting_per_area": 0.65, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 100.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 7.15, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Classroom", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Classroom/Lecture/Training", "lighting_secondary_space_type": "General", "lighting_per_area": 1.23, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Classrooms (age 9 plus)", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 35.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.929, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.41, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Gym", "rgb": "154_230_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Gym, stadium (play area)", "ventilation_per_area": 0.3, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.46, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 159.5, "service_water_heating_area": 21269.0, "service_water_heating_peak_flow_per_area": 0.007499177206, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Kitchen", "rgb": "78_222_133", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Food Preparation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.99, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Food and Beverage Service", "ventilation_secondary_space_type": "Cafeteria/fast food dining", "ventilation_per_area": 0.18, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 15.23, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": 532.1, "gas_equipment_fraction_latent": 0.1, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.7, "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH", "electric_equipment_per_area": 20.65, "electric_equipment_fraction_latent": 0.25, "electric_equipment_fraction_radiant": 0.3, "electric_equipment_fraction_lost": 0.2, "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": 133.0, "service_water_heating_area": 2325.0, "service_water_heating_peak_flow_per_area": 0.05720430108, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 694.5023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Library", "rgb": "230_196_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Library", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Educational Facilities", "ventilation_secondary_space_type": "Media center", "ventilation_per_area": 0.12, "ventilation_per_person": 10, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.93, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Lobby", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lobby", "lighting_secondary_space_type": "General", "lighting_per_area": 0.9, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SecondarySchool", "space_type": "Restroom", "rgb": "169_169_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.2, "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH", "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.37, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH", "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback", "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback", "service_water_heating_peak_flow_rate": 52.2, "service_water_heating_area": 2260.0, "service_water_heating_peak_flow_per_area": 0.02309734513, "service_water_heating_target_temperature": 43.3, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 110.36763444376396, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "Corridor", "rgb": "169_31_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Corridor/Transition", "lighting_secondary_space_type": "General", "lighting_per_area": 0.41, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "Elec/MechRoom", "rgb": "41_31_175", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": null, "occupancy_activity_schedule": null, "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 198.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS", "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "Exercise", "rgb": "154_230_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Gymnasium/Fitness Center", "lighting_secondary_space_type": "Exercise Area", "lighting_per_area": 0.72, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Sports and Entertainment", "ventilation_secondary_space_type": "Health club/weight rooms", "ventilation_per_area": 0.06, "ventilation_per_person": 20, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 19.94, "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.73, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "GuestLounge", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 30.0, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.42, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "GuestRoom123Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "GuestRoom123Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "GuestRoom4Occ", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2013", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.028, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base", "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "GuestRoom4Vac", "rgb": "78_167_222", "lighting_standard": "ASHRAE 90.1-2013", "lighting_primary_space_type": "Guest Room", "lighting_secondary_space_type": "For Hotel", "lighting_per_area": 0.91, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall AlwaysOff", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Bedroom/living Room", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 4.27, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.028, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.1, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch", "service_water_heating_peak_flow_rate": 2.22, "service_water_heating_area": 351.0, "service_water_heating_peak_flow_per_area": 0.006324786325, "service_water_heating_target_temperature": 60.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall AlwaysOff", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "Yes", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "Laundry", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Hospital", "lighting_secondary_space_type": "Laundry-Washing", "lighting_per_area": 0.52, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Coinoperated laundries", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": 129.9, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch", "electric_equipment_per_area": 2.57, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": 123.0, "service_water_heating_area": 1053.0, "service_water_heating_peak_flow_per_area": 0.1168091168, "service_water_heating_target_temperature": 82.2, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "Mechanical", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Electrical/Mechanical", "lighting_secondary_space_type": "General", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.2, "gas_equipment_fraction_lost": 0.5, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "Meeting", "rgb": "230_196_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Conference/Meeting/Multipurpose", "lighting_secondary_space_type": "General", "lighting_per_area": 1.11, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Conference/meeting", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 50.0, "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.574, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 7.14, "occupancy_schedule": "HotelSmall Office_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.28, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "PublicRestroom", "rgb": "169_169_31", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Restrooms", "lighting_secondary_space_type": "General", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_RESTROOM_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 2.85, "occupancy_schedule": "HotelSmall Lobby_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 69.45023196377475, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "StaffLounge", "rgb": "31_169_34", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Lounge/Recreation", "lighting_secondary_space_type": "General", "lighting_per_area": 0.73, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories", "ventilation_secondary_space_type": "Lobbies/prefunction", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 51.28, "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 2.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch", "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch", "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "Stair", "rgb": "230_157_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Stairway", "lighting_secondary_space_type": "General", "lighting_per_area": 0.49, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Corridors", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SmallHotel", "space_type": "Storage", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "HotelSmall AlwaysOff", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.112, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Always On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "HotelSmall AlwaysOff", "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch", "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": "No", "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "StripMall", "space_type": "Strip mall - type 1", "rgb": "171_222_78", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.32, "lighting_per_person": null, "additional_lighting_per_area": 0.38346, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type1_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0495376, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type1_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "StripMall", "space_type": "Strip mall - type 2", "rgb": "171_222_78", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.32, "lighting_per_person": null, "additional_lighting_per_area": 0.18346, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type2_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0349328, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type2_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "StripMall", "space_type": "Strip mall - type 3", "rgb": "171_222_78", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Whole Building", "lighting_secondary_space_type": "Retail", "lighting_per_area": 1.32, "lighting_per_person": null, "additional_lighting_per_area": 0.0336, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "General Sales combined by area", "ventilation_per_area": 0.2325, "ventilation_per_person": 0, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "RetailStripmall Type3_OCC_SCH", "occupancy_activity_schedule": "HotelSmall Activity_Sch", "infiltration_per_exterior_area": 0.0349328, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "RetailStripmall Type3_Infil_SCH", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.4, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH", "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM", "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_OPTIMUM", "service_water_heating_peak_flow_rate": 1.8, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH", "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SuperMarket", "space_type": "Deli/Bakery", "rgb": "31_169_34", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": 6.25, "gas_equipment_fraction_latent": 0.0, "gas_equipment_fraction_radiant": 0.5, "gas_equipment_fraction_lost": 0.0, "gas_equipment_schedule": "SuperMarket Bldg Equip", "electric_equipment_per_area": 3.6400015672260313, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": 5.0, "service_water_heating_area": 2334.5, "service_water_heating_peak_flow_per_area": 0.00214178625, "service_water_heating_target_temperature": 49.0, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "SuperMarket SWH", "exhaust_fan_efficiency": 0.338, "exhaust_fan_power": 520.8767397283107, "exhaust_fan_pressure_rise": 0.5, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": "SuperMarket_Deli_Exhaust", "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SuperMarket", "space_type": "DryStorage", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Storage", "lighting_secondary_space_type": "General", "lighting_per_area": 0.63, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "General", "ventilation_secondary_space_type": "Storage rooms", "ventilation_per_area": 0.12, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 3.33, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SuperMarket", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.97, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 5.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.5400002325005652, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "SuperMarket", "space_type": "Sales/Produce", "rgb": "230_196_120", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "General", "lighting_per_area": 1.5, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.7, "lighting_fraction_visible": 0.2, "lighting_schedule": "SuperMarket Bldg Light", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Supermarket", "ventilation_per_area": 0.06, "ventilation_per_person": 7.5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 8.0, "occupancy_schedule": "SuperMarket Bldg Occ", "occupancy_activity_schedule": "SuperMarket Activity", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "SuperMarket Infil Half On", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.36000015500037674, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "SuperMarket Bldg Equip", "heating_setpoint_schedule": "SuperMarket HtgSetp", "cooling_setpoint_schedule": "SuperMarket ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Warehouse", "space_type": "Bulk", "rgb": "41_31_169", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Medium/Bulky Material Storage", "lighting_per_area": 0.58, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse ALWAYS_ON", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.237684638, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Warehouse", "space_type": "Fine", "rgb": "120_149_230", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Warehouse", "lighting_secondary_space_type": "Fine Material Storage", "lighting_per_area": 0.95, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.42, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Miscellaneous Spaces", "ventilation_secondary_space_type": "Warehouses", "ventilation_per_area": 0.06, "ventilation_per_person": "", "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 0.0, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse ALWAYS_ON", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Bldg Equip", "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule", "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null }, { "template": "OEESC 2014", "building_type": "Warehouse", "space_type": "Office", "rgb": "120_230_199", "lighting_standard": "OEESC 2014", "lighting_primary_space_type": "Office-Enclosed", "lighting_secondary_space_type": "General", "lighting_per_area": 0.82, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.37, "lighting_fraction_visible": 0.18, "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH", "ventilation_standard": "ASHRAE 62.1-2007", "ventilation_primary_space_type": "Office Buildings", "ventilation_secondary_space_type": "Office space", "ventilation_per_area": 0.06, "ventilation_per_person": 5, "ventilation_air_changes": "", "minimum_total_air_changes": null, "occupancy_per_area": 1.96, "occupancy_schedule": "Warehouse BLDG_OCC_SCH", "occupancy_activity_schedule": "Warehouse Office Activity Schedule", "infiltration_per_exterior_area": 0.0446, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": "Warehouse ALWAYS_ON", "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.75, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.5, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "Warehouse Office_Plug_SCH", "heating_setpoint_schedule": "Warehouse HtgSetp", "cooling_setpoint_schedule": "Warehouse ClgSetp", "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": "", "service_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_schedule": null, "balanced_exhaust_fraction_schedule": null, "is_residential": null, "necb_hvac_system_selection_type": null, "necb_schedule_type": null } ] }