3.0 aedg_k_12_fenestration_and_daylighting_controls 76683121-d531-46c0-8e1c-749c1ff646f0 7adff6ff-f7b8-48a5-bcb6-e1d9b999a224 20200319T195610Z 6FAFA9DE AedgK12FenestrationAndDaylightingControls AEDG K12 - Fenestration and Daylighting Controls This measure will remove all existing exterior windows, glass doors, and skylights from your model. They will be replaced with view and daylight windows as recommended by the K12 AEDG recommendations. Windows on the south facade will have a exterior shading or light shelf surfaces depending on if they are view or daylight windows. East and west view windows will have internal shading controls. In spaces with daylighting controls daylight sensor will be added. The modeler should inspect where the sensors were placed, the recommended illuminance setpoint, and the fraction of the zones lighting controlled by the sensor. This measure is intended for use in models created form space types defined in the primary and secondary building types. Other space types used in the model will not receive any new fenestration, however fenestration will be removed from all space types. Attic and plenum spaces will not receive any new fenestration. Daylighting will only be added to north and south facades. North and south facades can be +/- 30 degrees of north and south. East and west facades will only receive view windows. Mechanical rooms won't relieve any view or daylight windows. Kitchens and Restrooms wont' receive any view windows. Skylights will be added when possible to gyms, libraries, and cafeterias. In spaces with skylights senors will be at the center of the space, in sidelight spaces the sensor's depth in from the wall will typically be the same as the height of the wall that the daylight windows is on. This depth is also what is used to calculate the daylight fraction of the space. In spaces that are non convex, such as an L shaped space, we may not be able to place a sensor, if that happens a warning will be issued. cost_daylight_glazing Cost per Area for Proposed Daylighting Window Constructions ($/ft^2). Double true false 0 cost_view_glazing Cost per Area for Proposed View Window Constructions ($/ft^2). Double true false 0 cost_skylight Cost per Area for Proposed Skylight Construction ($/ft^2). Double true false 0 cost_shading_surface Cost per Area for Proposed Exterior Shading Surface Construction ($/ft^2). Double true false 0 cost_light_shelf Cost per Area for Proposed Light Shelf Construction ($/ft^2). Double true false 0 Envelope.Fenestration Measure Type ModelMeasure string Uses SketchUp API false boolean SecondarySchoolCustomRef_01_0228.osm osm test 3E42FA7D README.md.erb erb readmeerb 703C9964 README.md md readme DDC5DD92 OsLib_AedgMeasures.rb rb resource 652337A6 AedgK12FenestrationAndDaylightingControls_Test.rb rb test A8B311EE LICENSE.md md license E0468DD6 os_lib_constructions.rb rb resource E1FA367A os_lib_helper_methods.rb rb resource 07B01D67 os_lib_lighting_and_equipment.rb rb resource 6CE32103 os_lib_outdoorair_and_infiltration.rb rb resource 273C65BE OpenStudio 2.0.0 2.0.0 measure.rb rb script 687CBBD1 os_lib_schedules.rb rb resource B38668F5 os_lib_geometry.rb rb resource 674C561A