<?xml version="1.0" encoding="UTF-8"?>
<testsuite name="OpenStudio::Analysis::Translator::Excel discrete variables" tests="2" time="0.37046" failures="0" errors="0" skipped="0">
  <testcase name="OpenStudio::Analysis::Translator::Excel discrete variables should have parsed the spreadsheet" time="0.000225">
  </testcase>
  <testcase name="OpenStudio::Analysis::Translator::Excel discrete variables should save the file" time="0.077837">
  </testcase>
  <system-out>
Analysis name is Example Analysis
  Adding measure item 'reduce_lighting_loads_by_percentage'
{"variable_type"=&gt;"variable", "display_name"=&gt;"Lighting Power Reduction", "machine_name"=&gt;"lighting_power_reduction", "name"=&gt;"lighting_power_reduction_percent", "index"=&gt;2, "method"=&gt;"lhs", "type"=&gt;"Double", "units"=&gt;nil, "distribution"=&gt;{"min"=&gt;nil, "max"=&gt;nil, "mean"=&gt;nil, "stddev"=&gt;nil, "discrete_values"=&gt;"[10,20,40,60]", "discrete_weights"=&gt;"[0.1,0.4,0.2,0.3]", "type"=&gt;"discrete_uncertain", "source"=&gt;"Some Source"}, "notes"=&gt;nil, "relation_to_eui"=&gt;nil}
  Adding measure item 'reducespaceinfiltrationbypercentage'
  Adding measure item 'adjust_thermostat_setpoints_by_degrees'
{"variable_type"=&gt;"variable", "display_name"=&gt;"Alter Design Day Thermostats?", "machine_name"=&gt;"alter_design_day_thermostats?", "name"=&gt;"alter_design_days", "index"=&gt;3, "method"=&gt;"lhs", "type"=&gt;"Bool", "units"=&gt;nil, "distribution"=&gt;{"min"=&gt;nil, "max"=&gt;nil, "mean"=&gt;nil, "stddev"=&gt;nil, "discrete_values"=&gt;"['true','false']", "discrete_weights"=&gt;"[0.8,0.2]", "type"=&gt;"discrete_uncertain", "source"=&gt;nil}, "notes"=&gt;nil, "relation_to_eui"=&gt;nil}
  Adding measure item 'set_r_value_of_insulation_for_exterior_walls_to_a_specific_value'
  Adding measure item 'set_r_value_of_insulation_for_roofs_to_a_specific_value'
  Adding measure item 'reduce_ventilation_by_percentage'
{"variable_type"=&gt;"variable", "display_name"=&gt;"Design Specification Outdoor Air Reduction (%).", "machine_name"=&gt;"design_specification_outdoor_air_reduction_(%).", "name"=&gt;"design_spec_outdoor_air_reduction_percent", "index"=&gt;2, "method"=&gt;"lhs", "type"=&gt;"Double", "units"=&gt;nil, "distribution"=&gt;{"min"=&gt;nil, "max"=&gt;nil, "mean"=&gt;nil, "stddev"=&gt;nil, "discrete_values"=&gt;"[0,10,30,60,90]", "discrete_weights"=&gt;nil, "type"=&gt;"discrete_uncertain", "source"=&gt;nil}, "notes"=&gt;nil, "relation_to_eui"=&gt;nil}
  </system-out>
  <system-err>
  </system-err>
</testsuite>