  "water_source_heat_pumps_heating": [
    {
      "template": "DOE Ref 1980-2004",
      "minimum_capacity": 0.0,
      "maximum_capacity": 9999999.0,
      "start_date": "1919-09-09T00:00:00+00:00",
      "end_date": "2999-09-09T00:00:00+00:00",
      "minimum_coefficient_of_performance_heating": 4.2,
      "notes": "From 90.1-2004 since no DOE Reference Buildings had heat pumps"
    }
  ]
}

Version data entries

35 entries across 35 versions & 1 rubygems

Version Path
openstudio-standards-0.7.1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.7.0 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.7.0.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.6.3 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.6.0.rc2 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.6.0.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.5.0 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.5.0.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.4.0 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.3.1.rc2 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.3.1.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.3.0 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.2.17.rc2 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.2.17.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.2.16 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.2.16.rc2 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.2.16.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.2.15 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.2.15.pre.rc2 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json
openstudio-standards-0.2.15.pre.rc1 lib/openstudio-standards/standards/ashrae_90_1/doe_ref_1980_2004/data/doe_ref_1980_2004.water_source_heat_pumps_heating.json