  "space_types": [
    {
      "template": "189.1-2009",
      "building_type": "FullServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 1.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "FullServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining Rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "FullServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "FullServiceRestaurant Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "FullServiceRestaurant Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.080001756670937,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp",
      "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "FullServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.08,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "FullServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "FullServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "FullServiceRestaurant Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "FullServiceRestaurant Infil Half On",
      "gas_equipment_per_area": 276.72,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "FullServiceRestaurant Gas Equip",
      "electric_equipment_per_area": 25.500010979193352,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp Kitchen",
      "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp Kitchen",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1501.0,
      "service_water_heating_peak_flow_per_area": 0.08860759494,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "FullServiceRestaurant SWH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "FullServiceRestaurant Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "RestaurantSitDown Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining Rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "ER_Exam",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.43,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.09,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "ER_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.25,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.9900000000000001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "ER_Trauma",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.43,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.92,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "ER_Triage",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.43,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.97,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "ICU_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Critical and Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "ICU_Open",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Critical and Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.19,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "ICU_PatRm",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Critical and Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.19,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.08,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": 70.46,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "Hospital Kitchen Gas",
      "electric_equipment_per_area": 5.47,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 150.0,
      "service_water_heating_area": 10000.0,
      "service_water_heating_peak_flow_per_area": 0.015,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 924.6539123,
      "exhaust_fan_pressure_rise": 0.5024115756,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Hospital Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "Lab",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Laboratory",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Laboratories",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.22,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 2850.0,
      "service_water_heating_peak_flow_per_area": 0.000701754386,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "Lobby",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.76,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 1.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 3,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.92,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical ClgSetp",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 600.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.99,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "PatCorridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "PatRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Nursing",
      "ventilation_secondary_space_type": "Patient Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 280.0,
      "service_water_heating_peak_flow_per_area": 0.003571428571,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "PhysTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.09,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5280.0,
      "service_water_heating_peak_flow_per_area": 0.0001893939394,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Hospital",
      "space_type": "Radiology",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Medical procedure",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 7.28,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Bldg Equip",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5250.0,
      "service_water_heating_peak_flow_per_area": 0.0001904761905,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "Banquet",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "LargeHotel Bldg Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0000000000000004,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "LargeHotel Bldg Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.26,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.45,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "LargeHotel Bldg Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "LargeHotel GuestRoom Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.68,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel GuestRoom Equip",
      "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "LargeHotel SWH GuestRoom",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.08,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "LargeHotel Bldg Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": 373.8,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "LargeHotel Kitchen Gas",
      "electric_equipment_per_area": 24.16,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "LargeHotel Kitchen Equip",
      "heating_setpoint_schedule": "LargeHotel Kitchen HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel Kitchen ClgSetp",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1112.0,
      "service_water_heating_peak_flow_per_area": 0.1196043165,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "LargeHotel SWH Kitchen",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 697.8520092823027,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "LargeHotel Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Dry Cleaners, Laundries",
      "ventilation_secondary_space_type": "Commercial Laundry",
      "ventilation_per_area": 0,
      "ventilation_per_person": 25,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.0,
      "occupancy_schedule": "LargeHotel Bldg Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": 123.8,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "LargeHotel LaundryRoom Gas",
      "electric_equipment_per_area": 2.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel LaundryRoom Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": 156.6,
      "service_water_heating_area": 840.0,
      "service_water_heating_peak_flow_per_area": 0.1864285714,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "LargeHotel SWH Laundry",
      "exhaust_per_area": 0.5952276390725688,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 87.23150116,
      "exhaust_fan_pressure_rise": 0.5024115756,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "LargeHotel Laundry Exhaust_Always On",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "LargeHotel Bldg Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.38,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "LargeHotel Bldg Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.26,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.53,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "LargeHotel Bldg Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.51,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "LargeHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Shipping and receiving",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.0,
      "occupancy_schedule": "LargeHotel Bldg Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.13,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "MidriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dormitory",
      "lighting_secondary_space_type": "Living Quarters",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "MidriseApartment Apartment Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "MidriseApartment Apartment Occ",
      "occupancy_activity_schedule": "MidriseApartment Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "MidriseApartment Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "MidriseApartment Apartment Equip",
      "heating_setpoint_schedule": "MidriseApartment Apartment HtgSetp",
      "cooling_setpoint_schedule": "MidriseApartment Apartment ClgSetp",
      "service_water_heating_peak_flow_rate": 3.5,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003684210526,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "MidriseApartment DHW",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "MidriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.45,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "MidriseApartment Corridor Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "MidriseApartment Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": "MidriseApartment Corridor HtgSetp",
      "cooling_setpoint_schedule": "MidriseApartment Corridor ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "MidriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "MidriseApartment Office Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "MidriseApartment Office Occ",
      "occupancy_activity_schedule": "MidriseApartment Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "MidriseApartment Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.87,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "MidriseApartment Office Equip",
      "heating_setpoint_schedule": "MidriseApartment Office HtgSetp",
      "cooling_setpoint_schedule": "MidriseApartment Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": "#N/A",
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Small Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "BreakRoom",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.08,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "ClosedOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.75,
      "occupancy_schedule": "Office Work Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.64,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.45,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Office Work Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.16,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.56,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "OpenOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Open Plan",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.25,
      "occupancy_schedule": "Office Work Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.71,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "PrintRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.79,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Medium Office Bldg Occ",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Stairs-Active",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "Vending",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.45,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.85,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "WholeBuilding - Lg Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Large Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Large Office Bldg Occ",
      "occupancy_activity_schedule": "Large Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Large Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Large Office Bldg Equip",
      "heating_setpoint_schedule": "Large Office HtgSetp",
      "cooling_setpoint_schedule": "Large Office ClgSetp",
      "service_water_heating_peak_flow_rate": 63.9,
      "service_water_heating_area": 498588.0,
      "service_water_heating_peak_flow_per_area": 0.0001281619293,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Office SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "WholeBuilding - Md Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Medium Office Bldg Occ",
      "occupancy_activity_schedule": "Medium Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Medium Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.54,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Medium Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": 27.7,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0005165212203,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Medium Office Bldg Swh",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Office",
      "space_type": "WholeBuilding - Sm Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Small Office Bldg Occ",
      "occupancy_activity_schedule": "Small Office Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Small Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.54,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Small Office Bldg Equip",
      "heating_setpoint_schedule": "Small Office HtgSetp",
      "cooling_setpoint_schedule": "Small Office ClgSetp",
      "service_water_heating_peak_flow_rate": 3.0,
      "service_water_heating_area": 5502.0,
      "service_water_heating_peak_flow_per_area": 0.0005452562704,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Office SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Anesthesia",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 1.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Anesthesia Storage",
      "ventilation_per_area": 1.2,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.009259259259,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Outpatient SWH",
      "exhaust_per_area": 1.3333346236599153,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 54.520672421626536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "BioHazard",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Bedpan Room",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 92.94,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "CleanWork",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Medical Supply",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Utility / Workroom",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 46.45,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "DressingRoom",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dressing/Locker/Fitting Room",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.8000000000000002,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Mechanical Equipment Room",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.64,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Exam",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.8000000000000002,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Hall",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.29,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Telecommunication centers and data entry areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.8000000000000002,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Janitor",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Janitors Closet / Utility",
      "ventilation_per_area": 1.5,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.87,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.8000000000000002,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "LockerRoom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dressing/Locker/Fitting Room",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Lockers",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.94,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.19,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Lounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.94,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.19,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "MRI",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 38.63,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 440.0,
      "service_water_heating_peak_flow_per_area": 0.002272727273,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Outpatient SWH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 166.5909435105255,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "MRI_Control",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.8,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 168.0,
      "service_water_heating_peak_flow_per_area": 0.005952380952,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Outpatient SWH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 63.6074511585643,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "MedGas",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "NurseStation",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 1.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 3,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": 17.4,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.0,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "Outpatient Bldg Equip",
      "electric_equipment_per_area": 2.92,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient OR HtgSetp",
      "cooling_setpoint_schedule": "Outpatient OR ClgSetp",
      "service_water_heating_peak_flow_rate": 6.0,
      "service_water_heating_area": 470.0,
      "service_water_heating_peak_flow_per_area": 0.01276595745,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Outpatient SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.8000000000000002,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "PACU",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Recovery",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.19,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.009259259259,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Outpatient SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "PhysicalTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.09,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 946,
      "service_water_heating_peak_flow_per_area": 0.001057082452,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Outpatient SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "PreOp",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Patient Room",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 263.5,
      "service_water_heating_peak_flow_per_area": 0.003795066414,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Outpatient SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "ProcedureRoom",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.43,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 3,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.19,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 285.0,
      "service_water_heating_peak_flow_per_area": 0.00350877193,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Outpatient SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Soil Work",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Medical Supply",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Soiled Linen, Sorting",
      "ventilation_per_area": 1.5,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748944,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 79.50931394820536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Stairs-Active",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Toilet",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.29,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748942,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 34.075420263516584,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Outpatient",
      "space_type": "Xray",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.95,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 900.0,
      "service_water_heating_peak_flow_per_area": 0.001111111111,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Outpatient SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 66.67,
      "occupancy_schedule": "PrimarySchool Cafeteria Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.72,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Classroom",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 23.22,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.02,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.45,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Gymnasium/Exercise Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.9,
      "occupancy_schedule": "PrimarySchool Gym Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3400000000000001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.08,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": 220.5,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "PrimarySchool Kitchen Gas",
      "electric_equipment_per_area": 13.130000000000003,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "PrimarySchool Kitchen Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": 100.0,
      "service_water_heating_area": 1808.0,
      "service_water_heating_peak_flow_per_area": 0.05530973451,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "PrimarySchool SWH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 572.9644137011418,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "PrimarySchool Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "SchoolPrimary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Libraries",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 21.36,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.02,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "PrimarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": 56.5,
      "service_water_heating_area": 2045.0,
      "service_water_heating_peak_flow_per_area": 0.02762836186,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "PrimarySchool SWH",
      "exhaust_per_area": 0.293378304967726,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 104.17534794566214,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 1.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "QuickServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "QuickServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "QuickServiceRestaurant Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "QuickServiceRestaurant Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 8.740003763064701,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp",
      "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.08,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "QuickServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "QuickServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "QuickServiceRestaurant Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "QuickServiceRestaurant Infil Half On",
      "gas_equipment_per_area": 298.6,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "QuickServiceRestaurant Gas Equip",
      "electric_equipment_per_area": 20.400008783354682,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.3,
      "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp Kitchen",
      "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp Kitchen",
      "service_water_heating_peak_flow_rate": 40.0,
      "service_water_heating_area": 1250.0,
      "service_water_heating_peak_flow_per_area": 0.032,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "QuickServiceRestaurant SWH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 575.7279076578998,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "QuickServiceRestaurant Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Retail",
      "space_type": "Back_Space",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.546,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Retail",
      "space_type": "Entry",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Mall Concourse",
      "lighting_per_area": 1.53,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Retail",
      "space_type": "Point_of_Sale",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.53,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.4500006243070729,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Retail",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.53,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Clothiers, furniture",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.22000009472245247,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Auditorium",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Audience/Seating Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Auditorium",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 92.94,
      "occupancy_schedule": "SecondarySchool Auditorium Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3400000000000001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 66.84,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Kitchen Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Classroom",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 23.22,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.68,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.45,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.31,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Gymnasium/Exercise Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 92.94,
      "occupancy_schedule": "SecondarySchool Gym Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3400000000000001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SecondarySchool SWH Showers",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.08,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.48,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": 258.6,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SecondarySchool Kitchen Gas",
      "electric_equipment_per_area": 15.05,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SecondarySchool Kitchen Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 2325.0,
      "service_water_heating_peak_flow_per_area": 0.05720430108,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SecondarySchool SWH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SecondarySchool Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "SchoolSecondary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Libraries",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 21.34,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.68,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "SecondarySchool Office Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SecondarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": 52.2,
      "service_water_heating_area": 2260.0,
      "service_water_heating_peak_flow_per_area": 0.02309734513,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SecondarySchool SWH",
      "exhaust_per_area": 0.2812153843741127,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 110.36763444376396,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": "#N/A",
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0751,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.45,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_171",
      "lighting_standard": null,
      "lighting_primary_space_type": null,
      "lighting_secondary_space_type": null,
      "lighting_per_area": "#N/A",
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.223,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 198.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Exercise",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Gymnasium/Exercise Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Exercise Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SmallHotel Exercise Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.55,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Exercise Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "GuestLounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.08,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel GuestRoom Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.97,
      "occupancy_schedule": "SmallHotel GuestRoom Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.68,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel GuestRoom Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": 1.75,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.004985754986,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SmallHotel SWH GuestRoom",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Laundry Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Dry Cleaners, Laundries",
      "ventilation_secondary_space_type": "Commercial Laundry",
      "ventilation_per_area": 0,
      "ventilation_per_person": 25,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SmallHotel Laundry Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": 42.6,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": "SmallHotel Laundry Gas",
      "electric_equipment_per_area": 1.0400004477788662,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Laundry Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": 67.5,
      "service_water_heating_area": 1053.0,
      "service_water_heating_peak_flow_per_area": 0.0641025641,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SmallHotel SWH Laundry",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Meeting Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "SmallHotel Meeting Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.61,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Meeting Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Office Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "SmallHotel Office Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.61,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Office Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "PublicRestroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.85,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.51,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.139566144206643,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 69.45023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "StaffLounge",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.08,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel StaffLounge Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 31.34,
      "occupancy_schedule": "SmallHotel StaffLounge Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.67,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel StaffLounge Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Stairs-Active",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SmallHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Storage Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "StripMall",
      "space_type": "WholeBuilding",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "StripMall Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "StripMall Bldg Occ",
      "occupancy_activity_schedule": "StripMall Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "StripMall Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2900001248614146,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "StripMall Bldg Equip",
      "heating_setpoint_schedule": "StripMall HtgSetp",
      "cooling_setpoint_schedule": "StripMall ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SuperMarket",
      "space_type": "Deli/Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.53,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": 6.25,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 3.6400015672260313,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SuperMarket",
      "space_type": "DryStorage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Shipping and receiving",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SuperMarket",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "SuperMarket",
      "space_type": "Sales/Produce",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.53,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.36000015500037674,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Warehouse",
      "space_type": "Bulk",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Medium/Bulky Material Storage",
      "lighting_per_area": 0.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Warehouse Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse Bldg Occ",
      "occupancy_activity_schedule": "Warehouse Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.17000007319462238,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse HtgSetp BulkStorage",
      "cooling_setpoint_schedule": "Warehouse ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Warehouse",
      "space_type": "Fine",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Fine Material Storage",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Warehouse Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse Bldg Occ",
      "occupancy_activity_schedule": "Warehouse Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse HtgSetp FineStorage",
      "cooling_setpoint_schedule": "Warehouse ClgSetp FineStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "189.1-2009",
      "building_type": "Warehouse",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Warehouse Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.96,
      "occupancy_schedule": "Warehouse Bldg Occ",
      "occupancy_activity_schedule": "Warehouse Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse HtgSetp",
      "cooling_setpoint_schedule": "Warehouse ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "FullServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "FullServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining Rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2016,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.032,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "FullServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2016,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": 205.81,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 37.53,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1501.0,
      "service_water_heating_peak_flow_per_area": 0.08860759494,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "RestaurantSitDown Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "HighriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentHighRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "HighriseApartment",
      "space_type": "Apartment_topfloor_NS",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentHighRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0575970048,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "HighriseApartment",
      "space_type": "Apartment_topfloor_WE",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentHighRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0803777592,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "HighriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "HighriseApartment",
      "space_type": "Corridor_topfloor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0234460331,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "HighriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": 1.1,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedrooms",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2004_2007",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "Basement",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Basement",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_BSMT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Basement",
      "ventilation_secondary_space_type": "For Hospital",
      "ventilation_per_area": 0.049,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.5,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining Rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "ER_Exam",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "ER_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "ER_Trauma",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "ER_Triage",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "ICU_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "ICU_Open",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Newborn Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "ICU_PatRm",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Newborn Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": 51.16,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 7.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 150.0,
      "service_water_heating_area": 10000.0,
      "service_water_heating_peak_flow_per_area": 0.015,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 229133.6778,
      "exhaust_fan_pressure_rise": 124.5,
      "exhaust_fan_maximum_flow_rate": 7200.0,
      "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "Lab",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Laboratory",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Laboratories",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 2850.0,
      "service_water_heating_peak_flow_per_area": 0.000701754386,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "Lobby",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.09999999999999999,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 2.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 3,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 600.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.99,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "PatCorridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "PatRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Nursing",
      "ventilation_secondary_space_type": "Patient Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 280.0,
      "service_water_heating_peak_flow_per_area": 0.003571428571,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "PhysTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5280.0,
      "service_water_heating_peak_flow_per_area": 0.0001893939394,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Hospital",
      "space_type": "Radiology",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Medical procedure",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5250.0,
      "service_water_heating_peak_flow_per_area": 0.0001904761905,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Banquet",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "HotelLarge MeetingRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.301,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Basement",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Basement",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Multipurpose assembly",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Corridor2",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.627,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom2",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.977,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.004734848485,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom3",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0566608,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.627,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom4",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.050904,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.977,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.004734848485,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": 767.0,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH",
      "electric_equipment_per_area": 47.2,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1112.0,
      "service_water_heating_peak_flow_per_area": 0.1196043165,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.16,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 4000.0,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Dry Cleaners, Laundries",
      "ventilation_secondary_space_type": "Commercial Laundry",
      "ventilation_per_area": 0,
      "ventilation_per_person": 25,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.0,
      "occupancy_schedule": "HotelLarge LaundryRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": 170.0,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 5.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 156.6,
      "service_water_heating_area": 840.0,
      "service_water_heating_peak_flow_per_area": 0.1864285714,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 0.16,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 500.0,
      "exhaust_schedule": "HotelLarge Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelLarge Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.7500000000000001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Retail2",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "LargeHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Shipping and receiving",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.24999999999999997,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "MidriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "MidriseApartment",
      "space_type": "Apartment_topfloor_NS",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0575970048,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "MidriseApartment",
      "space_type": "Apartment_topfloor_WE",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0803777592,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "MidriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_COR_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "MidriseApartment",
      "space_type": "Corridor_topfloor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0234460331,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_COR_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "MidriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": 1.1,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedrooms",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2004_2007",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_No_Setback",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "BreakRoom",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.58,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Classroom",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Classroom",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 35.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "ClosedOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.75,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.87,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.29,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Dining",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "OfficeLarge Data Center",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "OfficeLarge",
      "lighting_secondary_space_type": "Data Center",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 20.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge ALWAYS_ON",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "OfficeLarge Main Data Center",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "OfficeLarge",
      "lighting_secondary_space_type": "Data Center",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 45.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge ALWAYS_ON",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "OpenOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Open Plan",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.25,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.96,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "PrintRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Stairs-Active",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "Vending",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.85,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "WholeBuilding - Lg Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.201599,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.74973447,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 27.7,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0005165212203,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "WholeBuilding - Md Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 51.0,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0009509957485,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Office",
      "space_type": "WholeBuilding - Sm Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.6,
      "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.63,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 3.0,
      "service_water_heating_area": 5502.0,
      "service_water_heating_peak_flow_per_area": 0.0005452562704,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Anesthesia",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Treatment / Examination",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 8.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.01851851852,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.3333346236599153,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 54.520672421626536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "BioHazard",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Bedpan Room",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 99.89,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "CleanWork",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Utility / Workroom",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 4.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 49.95,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "DressingRoom",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "ElevatorPumpRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.1,
      "electric_equipment_fraction_lost": 0.9,
      "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_24_7",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Exam",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Hall",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Hall_infil",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Telecommunication centers and data entry areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Janitor",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Bathroom/ Public",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "LockerRoom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Lounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "MRI",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 440.0,
      "service_water_heating_peak_flow_per_area": 0.004545454545,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 166.5909435105255,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "MRI_Control",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 168.0,
      "service_water_heating_peak_flow_per_area": 0.0119047619,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 63.6074511585643,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "MedGas",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "NurseStation",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 2.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Operating rooms outpatient",
      "ventilation_per_area": 0.5,
      "ventilation_per_person": 30,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 20.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": 23.87,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.0,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH",
      "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 12.0,
      "service_water_heating_area": 472.0,
      "service_water_heating_peak_flow_per_area": 0.02542372881,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "PACU",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 316.0,
      "service_water_heating_peak_flow_per_area": 0.006329113924,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "PhysicalTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 946,
      "service_water_heating_peak_flow_per_area": 0.002114164905,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "PreOp",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 263.5,
      "service_water_heating_peak_flow_per_area": 0.007590132827,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "ProcedureRoom",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Procedure Room Outpatient",
      "ventilation_per_area": 0.8,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 15.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 285.0,
      "service_water_heating_peak_flow_per_area": 0.00701754386,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Reception",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 29.97,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Soil Work",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Medical Supply",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Linen Storage",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748944,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 79.50931394820536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Toilet",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748942,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 34.075420263516584,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Undeveloped",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Bathroom/ Public",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Outpatient",
      "space_type": "Xray",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 900.0,
      "service_water_heating_peak_flow_per_area": 0.002222222222,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Classroom",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 25.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Gymnasium/Exercise Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 453.7,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 17.7,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 100.0,
      "service_water_heating_area": 1808.0,
      "service_water_heating_peak_flow_per_area": 0.05530973451,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 572.9644137011418,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolPrimary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Libraries",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 0.0,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "PrimarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 56.5,
      "service_water_heating_area": 2045.0,
      "service_water_heating_peak_flow_per_area": 0.02762836186,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.293378304967726,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 104.17534794566214,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2016,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.85,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2016,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": 250.86,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 25.166,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.3,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 40.0,
      "service_water_heating_area": 1250.0,
      "service_water_heating_peak_flow_per_area": 0.032,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 575.7279076578998,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantFastFood Hours_of_operation",
      "balanced_exhaust_fraction_schedule": "RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Retail",
      "space_type": "Back_Space",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Retail",
      "space_type": "Entry",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Retail",
      "space_type": "Point_of_Sale",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Retail",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Clothiers, furniture",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Auditorium",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Audience/Seating Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Auditorium",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 150.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 7.15,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Classroom",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 35.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Gymnasium/Exercise Center",
      "lighting_secondary_space_type": "Playing Area",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.23,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 532.1,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 20.65,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 2325.0,
      "service_water_heating_peak_flow_per_area": 0.05720430108,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolSecondary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Libraries",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SecondarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": 52.2,
      "service_water_heating_area": 2260.0,
      "service_water_heating_peak_flow_per_area": 0.02309734513,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.2812153843741127,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 110.36763444376396,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Corridor4",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0258,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_174",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 198.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore",
      "rgb": "41_31_174",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore4",
      "rgb": "41_31_174",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.05042,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Exercise",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Gymnasium/Exercise Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Spectator areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 19.94,
      "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "GuestLounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.42,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel GuestRoom Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedrooms",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedrooms",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel GuestRoom Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedrooms",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0504,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedrooms",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0504,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Dry Cleaners, Laundries",
      "ventilation_secondary_space_type": "Commercial Laundry",
      "ventilation_per_area": 0,
      "ventilation_per_person": 25,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": 129.9,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch",
      "electric_equipment_per_area": 2.57,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 67.5,
      "service_water_heating_area": 1053.0,
      "service_water_heating_peak_flow_per_area": 0.0641025641,
      "service_water_heating_target_temperature": 82.2,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.574,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Office Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "HotelSmall Office_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.28,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "PublicRestroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.85,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.139566144206643,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 69.45023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "StaffLounge",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 51.28,
      "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Stairs-Active",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Stair4",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Stairs-Active",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.1196,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Storage Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Storage4Front",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Storage Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0504,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SmallHotel",
      "space_type": "Storage4Rear",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Storage Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.1196,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 1",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.95,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type1_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0891675017,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type1_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 2",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.375,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type2_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0628789142,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type2_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 3",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type3_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0628789142,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type3_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": 5.0,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 2.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Deli",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": 2.5,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Deli/Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": 8.53,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Dining",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.6,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "DryStorage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Shipping and receiving",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 1.04,
      "ventilation_per_person": 0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Sales/Produce",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "SuperMarket",
      "space_type": "Vestibule",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil New",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip New",
      "heating_setpoint_schedule": "SuperMarket Vestibule HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket Vestibule ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Warehouse",
      "space_type": "Bulk",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Medium/Bulky Material Storage",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0444,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse Bulk Infil Schedule",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.237684638,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Warehouse",
      "space_type": "Fine",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Fine Material Storage",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0444,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse Fine Infil Schedule",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2004",
      "building_type": "Warehouse",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.96,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0433,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse Office Infil Schedule",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Office_Plug_SCH",
      "heating_setpoint_schedule": "Warehouse HtgSetp",
      "cooling_setpoint_schedule": "Warehouse ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "FullServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "FullServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Restaurant dining rooms",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2016,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.032,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "FullServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2016,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": 205.81,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 37.53,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1501.0,
      "service_water_heating_peak_flow_per_area": 0.08860759494,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "RestaurantSitDown Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "HighriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "HighriseApartment",
      "space_type": "Apartment_topfloor_NS",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0575970048,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "HighriseApartment",
      "space_type": "Apartment_topfloor_WE",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0803777592,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "HighriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "HighriseApartment",
      "space_type": "Corridor_topfloor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0234460331,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "HighriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": 1.1,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Living rooms",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2004_2007",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Basement",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Basement",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_BSMT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Basement",
      "ventilation_secondary_space_type": "For Hospital",
      "ventilation_per_area": 0.072495,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.5,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "ER_Exam",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "ER_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "ER_Trauma",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "ER_Triage",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "ICU_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "ICU_Open",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Newborn Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "ICU_PatRm",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Newborn Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": 51.16,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 7.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 150.0,
      "service_water_heating_area": 10000.0,
      "service_water_heating_peak_flow_per_area": 0.015,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 229133.6778,
      "exhaust_fan_pressure_rise": 124.5,
      "exhaust_fan_maximum_flow_rate": 7200.0,
      "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Lab",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Medical Supply",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Science laboratories",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 2850.0,
      "service_water_heating_peak_flow_per_area": 0.000701754386,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Lobby",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.33,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Lobby",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.33,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.04,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 2.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 3,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 600.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 2.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 3,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.92,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 600.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.99,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "PatCorridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "PatCorridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "PatRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Nursing",
      "ventilation_secondary_space_type": "Patient Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 280.0,
      "service_water_heating_peak_flow_per_area": 0.003571428571,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "PhysTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5280.0,
      "service_water_heating_peak_flow_per_area": 0.0001893939394,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Hospital",
      "space_type": "Radiology",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Medical procedure",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5250.0,
      "service_water_heating_peak_flow_per_area": 0.0001904761905,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Banquet",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Multipurpose assembly",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "HotelLarge MeetingRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.301,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Basement",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Multipurpose assembly",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Corridor2",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.627,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom2",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.977,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.004734848485,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom3",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0566608,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.627,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom4",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.050904,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.977,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.004734848485,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": 767.0,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH",
      "electric_equipment_per_area": 47.2,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1112.0,
      "service_water_heating_peak_flow_per_area": 0.1196043165,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.16,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 4000.0,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Coinoperated laundries",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.0,
      "occupancy_schedule": "HotelLarge LaundryRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": 170.0,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 5.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 156.6,
      "service_water_heating_area": 840.0,
      "service_water_heating_peak_flow_per_area": 0.1864285714,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 0.16,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 500.0,
      "exhaust_schedule": "HotelLarge Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelLarge Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Retail2",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "LargeHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.25,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "MidriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "MidriseApartment",
      "space_type": "Apartment_topfloor_NS",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0575970048,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "MidriseApartment",
      "space_type": "Apartment_topfloor_WE",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0803777592,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "MidriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_COR_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "MidriseApartment",
      "space_type": "Corridor_topfloor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0234460331,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_COR_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "MidriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": 1.1,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Living rooms",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2004_2007",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_No_Setback",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "BreakRoom",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Classroom",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (age 9 plus)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 35.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "ClosedOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.75,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.64,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.16,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Dining",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Reception areas",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Telephone/data entry",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.56,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "OfficeLarge Data Center",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "OfficeLarge",
      "lighting_secondary_space_type": "Data Center",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 20.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge ALWAYS_ON",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "OfficeLarge Main Data Center",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "OfficeLarge",
      "lighting_secondary_space_type": "Data Center",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 45.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge ALWAYS_ON",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "OpenOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Open Plan",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.25,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.71,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "PrintRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.79,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Stairs-Active",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "Vending",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.85,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "WholeBuilding - Lg Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.201599,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.74973447,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 27.7,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0005165212203,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "WholeBuilding - Md Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2004",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2004",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 51.0,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0009509957485,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Office",
      "space_type": "WholeBuilding - Sm Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.6,
      "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.63,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 3.0,
      "service_water_heating_area": 5502.0,
      "service_water_heating_peak_flow_per_area": 0.0005452562704,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Anesthesia",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Treatment / Examination",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 8.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.01851851852,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.3333346236599153,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 54.520672421626536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "BioHazard",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 99.89,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "CleanWork",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Utility / Workroom",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 4.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 49.95,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "DressingRoom",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "ElevatorPumpRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.1,
      "electric_equipment_fraction_lost": 0.9,
      "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_24_7",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Exam",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Hall",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Hall_infil",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Telephone/data entry",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Janitor",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "LockerRoom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Lounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "MRI",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 440.0,
      "service_water_heating_peak_flow_per_area": 0.004545454545,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 166.5909435105255,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "MRI_Control",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 168.0,
      "service_water_heating_peak_flow_per_area": 0.0119047619,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 63.6074511585643,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "MedGas",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "NurseStation",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 2.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Operating rooms outpatient",
      "ventilation_per_area": 0.5,
      "ventilation_per_person": 30,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 20.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": 23.87,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.0,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH",
      "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 12.0,
      "service_water_heating_area": 472.0,
      "service_water_heating_peak_flow_per_area": 0.02542372881,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "PACU",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 316.0,
      "service_water_heating_peak_flow_per_area": 0.006329113924,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "PhysicalTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 946,
      "service_water_heating_peak_flow_per_area": 0.002114164905,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "PreOp",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 263.5,
      "service_water_heating_peak_flow_per_area": 0.007590132827,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "ProcedureRoom",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Procedure Room Outpatient",
      "ventilation_per_area": 0.8,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 15.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 285.0,
      "service_water_heating_peak_flow_per_area": 0.00701754386,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Reception",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 29.97,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Soil Work",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Linen Storage",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748944,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 79.50931394820536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Toilet",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748942,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 34.075420263516584,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Undeveloped",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Outpatient",
      "space_type": "Xray",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 0.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 900.0,
      "service_water_heating_peak_flow_per_area": 0.002222222222,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (ages 5-8)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 25.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Gymnasium/Exercise Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Gym, stadium (play area)",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 453.7,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 17.7,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 100.0,
      "service_water_heating_area": 1808.0,
      "service_water_heating_peak_flow_per_area": 0.05530973451,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 572.9644137011418,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolPrimary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Media center",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "PrimarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 56.5,
      "service_water_heating_area": 2045.0,
      "service_water_heating_peak_flow_per_area": 0.02762836186,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.293378304967726,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 104.17534794566214,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2016,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.85,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2004_2007",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2016,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": 250.86,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 25.166,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.3,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 40.0,
      "service_water_heating_area": 1250.0,
      "service_water_heating_peak_flow_per_area": 0.032,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 575.7279076578998,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantFastFood Hours_of_operation",
      "balanced_exhaust_fraction_schedule": "RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Retail",
      "space_type": "Back_Space",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Retail",
      "space_type": "Entry",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Retail",
      "space_type": "Point_of_Sale",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Retail",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Auditorium",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Audience/Seating Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Public Assembly Spaces",
      "ventilation_secondary_space_type": "Auditorium seating area",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 150.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 7.15,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (age 9 plus)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 35.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Gymnasium/Exercise Center",
      "lighting_secondary_space_type": "Playing Area",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Gym, stadium (play area)",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.23,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 532.1,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 20.65,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 2325.0,
      "service_water_heating_peak_flow_per_area": 0.05720430108,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolSecondary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Media center",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SecondarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": 52.2,
      "service_water_heating_area": 2260.0,
      "service_water_heating_peak_flow_per_area": 0.02309734513,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.2812153843741127,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 110.36763444376396,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Corridor4",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0258,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_173",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 198.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore",
      "rgb": "41_31_173",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore4",
      "rgb": "41_31_173",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.05042,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Exercise",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Gymnasium/Exercise Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Health club/weight rooms",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 19.94,
      "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "GuestLounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.42,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel GuestRoom Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel GuestRoom Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0504,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Base_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Base_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hotel/Motel",
      "lighting_secondary_space_type": "Guest Rooms",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0504,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Coinoperated laundries",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": 129.9,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch",
      "electric_equipment_per_area": 2.57,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 67.5,
      "service_water_heating_area": 1053.0,
      "service_water_heating_peak_flow_per_area": 0.0641025641,
      "service_water_heating_target_temperature": 82.2,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.574,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Office Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "HotelSmall Office_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.28,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "PublicRestroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.85,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.139566144206643,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 69.45023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "StaffLounge",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 51.28,
      "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Stairs-Active",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Stair4",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Stairs-Active",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.1196,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Storage Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.2016,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Storage4Front",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Storage Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0504,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SmallHotel",
      "space_type": "Storage4Rear",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Storage Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.1196,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 1",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.72,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type1_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0891675017,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type1_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 2",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.5,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type2_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0628789142,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type2_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 3",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.07,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type3_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0628789142,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type3_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": "#N/A",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": 5.0,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 2.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Deli",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": "#N/A",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": 2.5,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Deli/Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": 6.25,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 3.6400015672260313,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Dining",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining rooms",
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.6,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "DryStorage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Active Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": "#N/A",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 1.04,
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Sales/Produce",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Retail (not including accent lighting)",
      "lighting_secondary_space_type": "Sales Area",
      "lighting_per_area": 1.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.36000015500037674,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "SuperMarket",
      "space_type": "Vestibule",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket Vestibule HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket Vestibule ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Warehouse",
      "space_type": "Bulk",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Medium/Bulky Material Storage",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Miscellaneous Spaces",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0444,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse Bulk Infil Schedule",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.237684638,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Warehouse",
      "space_type": "Fine",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Fine Material Storage",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Miscellaneous Spaces",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0444,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse Fine Infil Schedule",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2007",
      "building_type": "Warehouse",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2007",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.96,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0433,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse Office Infil Schedule",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Office_Plug_SCH",
      "heating_setpoint_schedule": "Warehouse HtgSetp",
      "cooling_setpoint_schedule": "Warehouse ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "FullServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "FullServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_DINING_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Restaurant dining rooms",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.032,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "FullServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": 205.81,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 37.53,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1501.0,
      "service_water_heating_peak_flow_per_area": 0.08860759494,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "RestaurantSitDown Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "HighriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "HighriseApartment",
      "space_type": "Apartment_topfloor_NS",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.031998336,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "HighriseApartment",
      "space_type": "Apartment_topfloor_WE",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0446543107,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "HighriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "HighriseApartment",
      "space_type": "Corridor_topfloor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0130255739,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "HighriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": 1.11,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Living rooms",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2010_2013",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "Basement",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Basement",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_BSMT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Basement",
      "ventilation_secondary_space_type": "For Hospital",
      "ventilation_per_area": 0.072495,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.5,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "ER_Exam",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "ER_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.87,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.33,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "ER_Trauma",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "ER_Triage",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "ICU_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.87,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.33,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "ICU_Open",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 1.15,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Newborn Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "ICU_PatRm",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.62,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Newborn Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": 51.16,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 7.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 150.0,
      "service_water_heating_area": 10000.0,
      "service_water_heating_peak_flow_per_area": 0.015,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.16,
      "exhaust_fan_power": 924.6539122990511,
      "exhaust_fan_pressure_rise": 124.5,
      "exhaust_fan_maximum_flow_rate": 7200.0,
      "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "Lab",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Laboratory",
      "lighting_secondary_space_type": "For Medical/Industrial/Research",
      "lighting_per_area": 1.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Science laboratories",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 2850.0,
      "service_water_heating_peak_flow_per_area": 0.000701754386,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "Lobby",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.33,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.87,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.33,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.04,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 1.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 3,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 600.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "PatCorridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "PatRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.62,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Nursing",
      "ventilation_secondary_space_type": "Patient Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 280.0,
      "service_water_heating_peak_flow_per_area": 0.003571428571,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "PhysTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5280.0,
      "service_water_heating_peak_flow_per_area": 0.0001893939394,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Hospital",
      "space_type": "Radiology",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 1.32,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Medical procedure",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5250.0,
      "service_water_heating_peak_flow_per_area": 0.0001904761905,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Banquet",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Multipurpose assembly",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0254576,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.301,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 1.0,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 0.0,
      "exhaust_fan_maximum_flow_rate": 1017.43109,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Basement",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Multipurpose assembly",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH_2010",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0192416,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Corridor2",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.627,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": "\n",
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom2",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.977,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.004734848485,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom3",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0566608,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.627,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom4",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.050904,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.977,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.004734848485,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0513,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": 767.0,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH",
      "electric_equipment_per_area": 47.2,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1112.0,
      "service_water_heating_peak_flow_per_area": 0.1196043165,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.16,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 4000.0,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Coinoperated laundries",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": 170.0,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 5.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 156.6,
      "service_water_heating_area": 840.0,
      "service_water_heating_peak_flow_per_area": 0.1864285714,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 0.16,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 500.0,
      "exhaust_schedule": "HotelLarge Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.06,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Retail2",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "LargeHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.25,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "MidriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "MidriseApartment",
      "space_type": "Apartment_topfloor_NS",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.031998336,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "MidriseApartment",
      "space_type": "Apartment_topfloor_WE",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0446543107,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "MidriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_COR_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "MidriseApartment",
      "space_type": "Corridor_topfloor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0130255739,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_COR_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "MidriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": 1.11,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Living rooms",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2010_2013",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_No_Setback",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "BreakRoom",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Classroom",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.24,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (age 9 plus)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 35.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "ClosedOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.75,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.64,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.23,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.16,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Dining",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Reception areas",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Telephone/data entry",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.56,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "OfficeLarge Data Center",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "OfficeLarge",
      "lighting_secondary_space_type": "Data Center",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 20.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge ALWAYS_ON",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "OfficeLarge Main Data Center",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "OfficeLarge",
      "lighting_secondary_space_type": "Data Center",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 45.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge ALWAYS_ON",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "OpenOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Open Plan",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.25,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.71,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "PrintRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.79,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Stairway",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.69,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "Vending",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.85,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "WholeBuilding - Lg Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.111999776,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.74973447,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 27.7,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0005165212203,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "WholeBuilding - Md Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2010",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 51.0,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0009509957485,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Office",
      "space_type": "WholeBuilding - Sm Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.6,
      "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.63,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 3.0,
      "service_water_heating_area": 5502.0,
      "service_water_heating_peak_flow_per_area": 0.0005452562704,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Anesthesia",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Treatment / Examination",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 8.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.01851851852,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.3333346236599153,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 54.520672421626536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "BioHazard",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 99.89,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "CleanWork",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Utility / Workroom",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 4.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.23,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 49.95,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "DressingRoom",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "ElevatorPumpRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.1,
      "electric_equipment_fraction_lost": 0.9,
      "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_ADD_DF",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Exam",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Hall",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Hall_infil",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Telephone/data entry",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Janitor",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH_20102013",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "LockerRoom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1.07,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Lounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1.07,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "MRI",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 1.32,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 440.0,
      "service_water_heating_peak_flow_per_area": 0.004545454545,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 166.5909435105255,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "MRI_Control",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 1.32,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 168.0,
      "service_water_heating_peak_flow_per_area": 0.0119047619,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 63.6074511585643,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "MedGas",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "NurseStation",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.87,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 1.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Operating rooms outpatient",
      "ventilation_per_area": 0.5,
      "ventilation_per_person": 30,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 20.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": 23.87,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.0,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH",
      "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 12.0,
      "service_water_heating_area": 472.0,
      "service_water_heating_peak_flow_per_area": 0.02542372881,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH_20102013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "PACU",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 1.15,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 316.0,
      "service_water_heating_peak_flow_per_area": 0.006329113924,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "PhysicalTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 946.0,
      "service_water_heating_peak_flow_per_area": 0.002114164905,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "PreOp",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.62,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 263.5,
      "service_water_heating_peak_flow_per_area": 0.007590132827,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "ProcedureRoom",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Procedure Room Outpatient",
      "ventilation_per_area": 0.8,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 15.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 285.0,
      "service_water_heating_peak_flow_per_area": 0.00701754386,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Reception",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 29.97,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Soil Work",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Linen Storage",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748944,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 79.50931394820536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Toilet",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748942,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 34.075420263516584,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Undeveloped",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Outpatient",
      "space_type": "Xray",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 1.32,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 900.0,
      "service_water_heating_peak_flow_per_area": 0.002222222222,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.24,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (ages 5-8)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 25.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Gymnasium/Fitness Center",
      "lighting_secondary_space_type": "Fitness Area",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Gym, stadium (play area)",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 453.7,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 17.7,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 100.0,
      "service_water_heating_area": 1808.0,
      "service_water_heating_peak_flow_per_area": 0.05530973451,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 572.9644137011418,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolPrimary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.18,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Media center",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "PrimarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 56.5,
      "service_water_heating_area": 2045.0,
      "service_water_heating_peak_flow_per_area": 0.02762836186,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.293378304967726,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 104.17534794566214,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.85,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": 250.86,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 25.166,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.3,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 40.0,
      "service_water_heating_area": 1250.0,
      "service_water_heating_peak_flow_per_area": 0.032,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 575.7279076578998,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantFastFood Hours_of_operation",
      "balanced_exhaust_fraction_schedule": "RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Retail",
      "space_type": "Back_Space",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Retail",
      "space_type": "Entry",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Retail",
      "space_type": "Point_of_Sale",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Sales Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.68,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Retail",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Sales Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.68,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Auditorium",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Audience/Seating Area",
      "lighting_secondary_space_type": "For Auditorium",
      "lighting_per_area": 0.79,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Public Assembly Spaces",
      "ventilation_secondary_space_type": "Auditorium seating area",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 150.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 7.15,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.24,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (age 9 plus)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 35.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Gymnasium/Fitness Center",
      "lighting_secondary_space_type": "Fitness Area",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Gym, stadium (play area)",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.23,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 532.1,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 20.65,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 2325.0,
      "service_water_heating_peak_flow_per_area": 0.05720430108,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolSecondary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.18,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Media center",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SecondarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": 52.2,
      "service_water_heating_area": 2260.0,
      "service_water_heating_peak_flow_per_area": 0.02309734513,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.2812153843741127,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 110.36763444376396,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Corridor4",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0143,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_175",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 198.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore",
      "rgb": "41_31_175",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore4",
      "rgb": "41_31_175",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.02801,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Exercise",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Gymnasium/Fitness Center",
      "lighting_secondary_space_type": "Fitness Area",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Health club/weight rooms",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 19.94,
      "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "GuestLounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.42,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Highway Lodging",
      "lighting_per_area": 0.75,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Highway Lodging",
      "lighting_per_area": 0.75,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Highway Lodging",
      "lighting_per_area": 0.75,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.028,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Highway Lodging",
      "lighting_per_area": 0.75,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.028,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Coinoperated laundries",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": 129.9,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch",
      "electric_equipment_per_area": 2.57,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 67.5,
      "service_water_heating_area": 1053.0,
      "service_water_heating_peak_flow_per_area": 0.0641025641,
      "service_water_heating_target_temperature": 82.2,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.23,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.574,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "HotelSmall Office_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.28,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "PublicRestroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_RESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.85,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.139566144206643,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 69.45023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "StaffLounge",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 51.28,
      "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Stairway",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.69,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Stair4",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Stairway",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.69,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0664,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Storage4Front",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.028,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SmallHotel",
      "space_type": "Storage4Rear",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.06644,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 1",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.42,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type1_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0495376,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type1_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 2",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.22,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type2_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0349328,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type2_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 3",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.07,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type3_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0349328,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type3_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SuperMarket",
      "space_type": "Deli/Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Sales Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.68,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": 6.25,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 3.6400015672260313,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SuperMarket",
      "space_type": "DryStorage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SuperMarket",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "SuperMarket",
      "space_type": "Sales/Produce",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Sales Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.68,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.36000015500037674,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Warehouse",
      "space_type": "Bulk",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Medium/Bulky Material Storage",
      "lighting_per_area": 0.58,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Miscellaneous Spaces",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0444,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse Bulk Infil Schedule",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.237684638,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.0,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Warehouse",
      "space_type": "Fine",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Fine Material Storage",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Miscellaneous Spaces",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0444,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse Fine Infil Schedule",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.0,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2010",
      "building_type": "Warehouse",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.96,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0433,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse Office Infil Schedule",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.0,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Office_Plug_SCH",
      "heating_setpoint_schedule": "Warehouse HtgSetp",
      "cooling_setpoint_schedule": "Warehouse ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "FullServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "FullServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_DINING_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Restaurant dining rooms",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.032,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "FullServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.21,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": 205.81,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 37.53,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1501.0,
      "service_water_heating_peak_flow_per_area": 0.08860759494,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "RestaurantSitDown Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "HighriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "HighriseApartment",
      "space_type": "Apartment_topfloor_NS",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.031998336,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "HighriseApartment",
      "space_type": "Apartment_topfloor_WE",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0446543107,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentHighRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "HighriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "HighriseApartment",
      "space_type": "Corridor_topfloor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_COR_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0130255739,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "HighriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentHighRise LTG_OFF_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Living rooms",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "ApartmentHighRise OCC_OFF_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentHighRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentHighRise EQP_OFF_SCH_2010_2013",
      "heating_setpoint_schedule": "ApartmentHighRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentHighRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "Basement",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Basement",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_BSMT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Basement",
      "ventilation_secondary_space_type": "For Hospital",
      "ventilation_per_area": 0.072495,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.5,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "ER_Exam",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "ER_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.71,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "ER_Trauma",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 2.48,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "ER_Triage",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 2.48,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "ICU_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.71,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "ICU_Open",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 1.15,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Newborn Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "ICU_PatRm",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.62,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Newborn Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.21,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": 51.16,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 7.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 150.0,
      "service_water_heating_area": 10000.0,
      "service_water_heating_peak_flow_per_area": 0.015,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 924.6539122990511,
      "exhaust_fan_pressure_rise": 124.5,
      "exhaust_fan_maximum_flow_rate": 7200.0,
      "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "Lab",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Laboratory",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Science laboratories",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 2850.0,
      "service_water_heating_peak_flow_per_area": 0.000701754386,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "Lobby",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.71,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.04,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 2.48,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 3,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 600.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.99,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "PatCorridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "PatRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.62,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Nursing",
      "ventilation_secondary_space_type": "Patient Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 280.0,
      "service_water_heating_peak_flow_per_area": 0.003571428571,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "PhysTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5280.0,
      "service_water_heating_peak_flow_per_area": 0.0001893939394,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Hospital",
      "space_type": "Radiology",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 1.51,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Medical procedure",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5250.0,
      "service_water_heating_peak_flow_per_area": 0.0001904761905,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Banquet",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Multipurpose assembly",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0254576,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.301,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 1.0,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 0.0,
      "exhaust_fan_maximum_flow_rate": 2000.0,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Basement",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Multipurpose assembly",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH_2010",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0192416,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Corridor2",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.627,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": "\n",
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom2",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.977,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.004734848485,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom3",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0566608,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.627,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom4",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.050904,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.977,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.004734848485,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.21,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0513,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": 767.0,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH",
      "electric_equipment_per_area": 47.2,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1112.0,
      "service_water_heating_peak_flow_per_area": 0.1196043165,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.385,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 4000.0,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Coinoperated laundries",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": 170.0,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 5.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 156.6,
      "service_water_heating_area": 840.0,
      "service_water_heating_peak_flow_per_area": 0.1864285714,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Post2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 0.385,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 500.0,
      "exhaust_schedule": "HotelLarge Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.06,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Retail2",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "LargeHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.25,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "MidriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "MidriseApartment",
      "space_type": "Apartment_topfloor_NS",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.031998336,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "MidriseApartment",
      "space_type": "Apartment_topfloor_WE",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.0446543107,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "MidriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_COR_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "MidriseApartment",
      "space_type": "Corridor_topfloor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.0130255739,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_COR_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "MidriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Living rooms",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2010_2013",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "BreakRoom",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Classroom",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.24,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (age 9 plus)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 35.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "ClosedOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.75,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.64,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.23,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.16,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Dining",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Reception areas",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.42,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Telephone/data entry",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.56,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "OfficeLarge Data Center",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "OfficeLarge",
      "lighting_secondary_space_type": "Data Center",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 20.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge ALWAYS_ON",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "OfficeLarge Main Data Center",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "OfficeLarge",
      "lighting_secondary_space_type": "Data Center",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 45.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge ALWAYS_ON",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_DC_SCH",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_DC_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "OpenOffice",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Open Plan",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.25,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.71,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "PrintRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.79,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Stairway",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.69,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "Vending",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.85,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "WholeBuilding - Lg Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeLarge INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.74973447,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 27.7,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0005165212203,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "WholeBuilding - Md Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2013",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 51.0,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0009509957485,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Office",
      "space_type": "WholeBuilding - Sm Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.6,
      "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.63,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 3.0,
      "service_water_heating_area": 5502.0,
      "service_water_heating_peak_flow_per_area": 0.0005452562704,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Anesthesia",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Treatment / Examination",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 8.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.01851851852,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.3333346236599153,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 54.520672421626536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "BioHazard",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 99.89,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "CleanWork",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Utility / Workroom",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 4.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.23,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 49.95,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "DressingRoom",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "ElevatorPumpRoom",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.1,
      "electric_equipment_fraction_lost": 0.9,
      "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_ADD_DF",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Exam",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Hall",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Hall_infil",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Telephone/data entry",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Janitor",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH_20102013",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "LockerRoom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Healthcare Facility",
      "lighting_per_area": 0.92,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Lounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Healthcare Facility",
      "lighting_per_area": 0.92,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "MRI",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 1.51,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 440.0,
      "service_water_heating_peak_flow_per_area": 0.004545454545,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 166.5909435105255,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "MRI_Control",
      "rgb": "136_78_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 1.51,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 168.0,
      "service_water_heating_peak_flow_per_area": 0.0119047619,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 63.6074511585643,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "MedGas",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "NurseStation",
      "rgb": "31_162_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.71,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 2.48,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Operating rooms outpatient",
      "ventilation_per_area": 0.5,
      "ventilation_per_person": 30,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 20.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": 23.87,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.0,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH",
      "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 12.0,
      "service_water_heating_area": 472.0,
      "service_water_heating_peak_flow_per_area": 0.02542372881,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH_20102013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "PACU",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 1.15,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 316.0,
      "service_water_heating_peak_flow_per_area": 0.006329113924,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "PhysicalTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 946.0,
      "service_water_heating_peak_flow_per_area": 0.002114164905,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "PreOp",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.62,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 263.5,
      "service_water_heating_peak_flow_per_area": 0.007590132827,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "ProcedureRoom",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Emergency",
      "lighting_per_area": 2.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Procedure Room Outpatient",
      "ventilation_per_area": 0.8,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 15.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 285.0,
      "service_water_heating_peak_flow_per_area": 0.00701754386,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Reception",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 29.97,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Soil Work",
      "rgb": "204_120_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Linen Storage",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748944,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 79.50931394820536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.792,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Toilet",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748942,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 34.075420263516584,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Undeveloped",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2010",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Outpatient",
      "space_type": "Xray",
      "rgb": "169_31_159",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 1.51,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 900.0,
      "service_water_heating_peak_flow_per_area": 0.002222222222,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.24,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (ages 5-8)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 25.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Gymnasium/Fitness Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Gym, stadium (play area)",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.21,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 453.7,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 17.7,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 100.0,
      "service_water_heating_area": 1808.0,
      "service_water_heating_peak_flow_per_area": 0.05530973451,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 572.9644137011418,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolPrimary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.19,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Media center",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.42,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "PrimarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 56.5,
      "service_water_heating_area": 2045.0,
      "service_water_heating_peak_flow_per_area": 0.02762836186,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.293378304967726,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 104.17534794566214,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.85,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.21,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": 250.86,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 25.166,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.3,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 40.0,
      "service_water_heating_area": 1250.0,
      "service_water_heating_peak_flow_per_area": 0.032,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 575.7279076578998,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantFastFood Hours_of_operation",
      "balanced_exhaust_fraction_schedule": "RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Retail",
      "space_type": "Back_Space",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Retail",
      "space_type": "Entry",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Retail",
      "space_type": "Point_of_Sale",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Sales Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.44,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Retail",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Sales Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.44,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Auditorium",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Audience/Seating Area",
      "lighting_secondary_space_type": "For Auditorium",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Public Assembly Spaces",
      "ventilation_secondary_space_type": "Auditorium seating area",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 150.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 7.15,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.24,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (age 9 plus)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 35.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Gymnasium/Fitness Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Gym, stadium (play area)",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.21,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.23,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 532.1,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 20.65,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 2325.0,
      "service_water_heating_peak_flow_per_area": 0.05720430108,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolSecondary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.19,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Media center",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.42,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SecondarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": 52.2,
      "service_water_heating_area": 2260.0,
      "service_water_heating_peak_flow_per_area": 0.02309734513,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.2812153843741127,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 110.36763444376396,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Corridor4",
      "rgb": "169_31_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Corridor",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0143,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_175",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 198.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore",
      "rgb": "41_31_175",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore4",
      "rgb": "41_31_175",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.02801,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Exercise",
      "rgb": "154_230_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Gymnasium/Fitness Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Health club/weight rooms",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 19.94,
      "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "GuestLounge",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.42,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.028,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.028,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Laundry/Washing Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Coinoperated laundries",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": 129.9,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch",
      "electric_equipment_per_area": 2.57,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 67.5,
      "service_water_heating_area": 1053.0,
      "service_water_heating_peak_flow_per_area": 0.0641025641,
      "service_water_heating_target_temperature": 82.2,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.42,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.23,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.574,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "HotelSmall Office_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.28,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "PublicRestroom",
      "rgb": "169_169_31",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_RESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.85,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.139566144206643,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 69.45023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "StaffLounge",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 51.28,
      "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Stairway",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.69,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Stair4",
      "rgb": "230_157_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Stairway",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.69,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0664,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Storage4Front",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.028,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SmallHotel",
      "space_type": "Storage4Rear",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.06644,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 1",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.38346,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type1_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0495376,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type1_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 2",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.18346,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type2_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0349328,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type2_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 3",
      "rgb": "171_222_78",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.0336,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type3_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0349328,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type3_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SuperMarket",
      "space_type": "Deli/Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Sales Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.44,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": 6.25,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 3.6400015672260313,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SuperMarket",
      "space_type": "DryStorage",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SuperMarket",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "SuperMarket",
      "space_type": "Sales/Produce",
      "rgb": "230_196_120",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Sales Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.44,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.36000015500037674,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Warehouse",
      "space_type": "Bulk",
      "rgb": "41_31_169",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Medium/Bulky Material Storage",
      "lighting_per_area": 0.58,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Miscellaneous Spaces",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse ALWAYS_ON",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.237684638,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Warehouse",
      "space_type": "Fine",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Fine Material Storage",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Miscellaneous Spaces",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse ALWAYS_ON",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "90.1-2013",
      "building_type": "Warehouse",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.96,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse ALWAYS_ON",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Office_Plug_SCH",
      "heating_setpoint_schedule": "Warehouse HtgSetp",
      "cooling_setpoint_schedule": "Warehouse ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "ASHRAE ",
      "building_type": null,
      "space_type": null,
      "rgb": null,
      "lighting_standard": null,
      "lighting_primary_space_type": null,
      "lighting_secondary_space_type": null,
      "lighting_per_area": null,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.22,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.22,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Office - 1 story",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Office - 1 story",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Office - 1 story",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Office - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Office - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Office - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Office -2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Office -2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Office -2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Retail medium",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Retail medium",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.22,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Retail small",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1978",
      "building_type": "Retail small",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 1978",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1978",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.22,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.25,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.05,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.21,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.25,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.05,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.21,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Office - 1 story",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Office - 1 story",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Office - 1 story",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.25,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Office - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Office - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Office - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.25,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Office -2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Office -2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Office -2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.25,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Retail medium",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.05,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Retail medium",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.21,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Retail small",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.05,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 1992",
      "building_type": "Retail small",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 1992",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 1992",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.21,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Office - 1 story",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Office - 1 story",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Office - 1 story",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Office - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Office - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Office - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Office -2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Office -2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Office -2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Retail medium",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Retail medium",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Retail small",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2001",
      "building_type": "Retail small",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2001",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2001",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Office - 1 story",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Office - 1 story",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Office - 1 story",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Office - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Office - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Office - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Office -2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Office -2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Office -2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Retail medium",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Retail medium",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Retail small",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2005",
      "building_type": "Retail small",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2005",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2005",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Office - 1 story",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Office - 1 story",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Office - 1 story",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Office - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Office - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Office - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Office -2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Office -2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Office -2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.18,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Retail medium",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Retail medium",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Retail small",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES 2008",
      "building_type": "Retail small",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES 2008",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES 2008",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.06,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.15,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Mixed use - 2 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Mixed use - 2 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Mixed use - 2 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.23,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.15,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Mixed use - 3 stories",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Mixed use - 3 stories",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Mixed use - 3 stories",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.23,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Office - 1 story",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Office - 1 story",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Office - 1 story",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Office - 3 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Office - 3 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Office - 3 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Office -2 stories",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Office -2 stories",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Office -2 stories",
      "ventilation_secondary_space_type": "Office",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeOccupancy",
      "occupancy_activity_schedule": "OfficePeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeReceptacle",
      "heating_setpoint_schedule": "OfficeHtgSetpt",
      "cooling_setpoint_schedule": "OfficeClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Retail medium",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.15,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Retail medium",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Retail medium",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Retail medium",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.23,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Retail small",
      "space_type": "Sales/Produce",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 3.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Sales/Produce",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 33.01,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.15,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "CEC CBES Pre-1978",
      "building_type": "Retail small",
      "space_type": "Storage",
      "rgb": null,
      "lighting_standard": "CEC CBES Pre-1978",
      "lighting_primary_space_type": "Retail small",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailLights",
      "ventilation_standard": "CEC CBES Pre-1978",
      "ventilation_primary_space_type": "Retail small",
      "ventilation_secondary_space_type": "Storage",
      "ventilation_per_area": 0.2,
      "ventilation_per_person": 15.0,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.0,
      "occupancy_schedule": "RetailOccupancy",
      "occupancy_activity_schedule": "RetailPeopleActivityLevel",
      "infiltration_per_exterior_area": 0.22,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailInfiltration",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.23,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailReceptacle",
      "heating_setpoint_schedule": "RetailHtgSetpt",
      "cooling_setpoint_schedule": "RetailClgSetpt",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "FullServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": 1.0,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "FullServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "FullServiceRestaurant",
      "lighting_secondary_space_type": "Dining",
      "lighting_per_area": 2.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "FullServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining Rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "FullServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "FullServiceRestaurant Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "FullServiceRestaurant Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.6,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp",
      "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "FullServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "FullServiceRestaurant",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.52,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "FullServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "FullServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "FullServiceRestaurant Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "FullServiceRestaurant Infil Half On",
      "gas_equipment_per_area": 378.75,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "FullServiceRestaurant Gas Equip",
      "electric_equipment_per_area": 35.0,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp Kitchen",
      "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp Kitchen",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1501.0,
      "service_water_heating_peak_flow_per_area": 0.08860759494,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "FullServiceRestaurant Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "RestaurantSitDown Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "Basement",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Basement",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Basement",
      "ventilation_secondary_space_type": "For Hospital",
      "ventilation_per_area": "",
      "ventilation_per_person": 21.186,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.5,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.749,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 1.355,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Dining",
      "lighting_per_area": 2.575,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining Rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "ER_Exam",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ER_Exam",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5000000000000002,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "ER_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ER_NurseStn",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.25,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "ER_Trauma",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ER_Trauma",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "ER_Triage",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ER_Triage",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "ICU_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ICU_NurseStn",
      "lighting_per_area": 1.71,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "ICU_Open",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ICU_Open",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": "#N/A",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0000000000000004,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "ICU_PatRm",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ICU_PatRm",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.69,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.42,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Kitchen",
      "ventilation_per_area": 0.371,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": 96.7,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "Hospital Kitchen Gas",
      "electric_equipment_per_area": 7.5,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "Hospital Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 150.0,
      "service_water_heating_area": 10000.0,
      "service_water_heating_peak_flow_per_area": 0.015,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 924.6539123,
      "exhaust_fan_pressure_rise": 0.5024115756,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Hospital Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "Lab",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Lab",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Laboratories",
      "ventilation_per_area": 1.4,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 2850.0,
      "service_water_heating_peak_flow_per_area": 0.000701754386,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "Lobby",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1.03,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.09999999999999999,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "NurseStn",
      "lighting_per_area": 1.458,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.04,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "OR",
      "lighting_per_area": 9.745,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Operating rooms",
      "ventilation_per_area": 0.7,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical ClgSetp",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 600.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 2.395,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.99,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "PatCorridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "PatCorridor",
      "lighting_per_area": 1.32,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "PatRoom",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "PatRoom",
      "lighting_per_area": 2.188,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Patient rooms",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 280.0,
      "service_water_heating_peak_flow_per_area": 0.003571428571,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "PhysTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "PhysTherapy",
      "lighting_per_area": 2.51,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5000000000000002,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5280.0,
      "service_water_heating_peak_flow_per_area": 0.0001893939394,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Hospital",
      "space_type": "Radiology",
      "rgb": "136_78_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 2.21,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Radiology",
      "ventilation_per_area": 0.7,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5250.0,
      "service_water_heating_peak_flow_per_area": 0.0001904761905,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Banquet",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Banquet",
      "lighting_per_area": 2.56,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dining rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 21.2,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 1.0,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 1.0e-05,
      "exhaust_fan_maximum_flow_rate": 2000.0,
      "exhaust_schedule": "Always On",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Basement",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Basement",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.5,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Cafe",
      "lighting_per_area": 1.46,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 1.22,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Corridor2",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 1.22,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "LargeHotel GuestRoom Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel GuestRoom Equip",
      "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom2",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "LargeHotel GuestRoom Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel GuestRoom Equip",
      "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp",
      "service_water_heating_peak_flow_rate": 23.743,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.08993560606,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom3",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "LargeHotel GuestRoom Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel GuestRoom Equip",
      "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom4",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "LargeHotel GuestRoom Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel GuestRoom Equip",
      "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp",
      "service_water_heating_peak_flow_rate": 11.247,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.04260227273,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.56,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": 511.0,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "LargeHotel Kitchen Gas",
      "electric_equipment_per_area": 47.1989,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "LargeHotel Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "LargeHotel Kitchen HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel Kitchen ClgSetp",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1112.0,
      "service_water_heating_peak_flow_per_area": 0.1196043165,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 1.0,
      "exhaust_fan_power": 689.0,
      "exhaust_fan_pressure_rise": 1.0e-05,
      "exhaust_fan_maximum_flow_rate": 94.2477825,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Laundry",
      "lighting_per_area": 1.14,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Dry Cleaners, Laundries",
      "ventilation_secondary_space_type": "Commercial Laundry",
      "ventilation_per_area": 0,
      "ventilation_per_person": 25,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": 170.0,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "LargeHotel LaundryRoom Gas",
      "electric_equipment_per_area": 5.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel LaundryRoom Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": 156.6,
      "service_water_heating_area": 840.0,
      "service_water_heating_peak_flow_per_area": 0.1864285714,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 0.34,
      "exhaust_fan_power": 87.0,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 500.0,
      "exhaust_schedule": "Always On",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.7500000000000001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Mechanical",
      "lighting_per_area": 0.8000000000000002,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 3.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Retail2",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 3.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "LargeHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.37,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Shipping and receiving",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.24999999999999997,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "MidriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36000000000000004,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "MidriseApartment Apartment Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 36,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "MidriseApartment Apartment Occ",
      "occupancy_activity_schedule": "MidriseApartment Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "MidriseApartment Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "MidriseApartment Apartment HtgSetp",
      "cooling_setpoint_schedule": "MidriseApartment Apartment ClgSetp",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "MidriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.92,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "MidriseApartment Corridor Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "MidriseApartment Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS Pre2004",
      "heating_setpoint_schedule": "MidriseApartment UnitHeater HtgSP Sch",
      "cooling_setpoint_schedule": "MidriseApartment UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "MidriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 2.04,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "MidriseApartment Office Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "MidriseApartment Office Occ",
      "occupancy_activity_schedule": "MidriseApartment Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "MidriseApartment OFFICE Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_Pre2004",
      "heating_setpoint_schedule": "MidriseApartment Office HtgSetp",
      "cooling_setpoint_schedule": "MidriseApartment Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": null,
      "lighting_primary_space_type": null,
      "lighting_secondary_space_type": null,
      "lighting_per_area": null,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": "#N/A",
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Small Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "BreakRoom",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "BreakRoom",
      "lighting_per_area": 1.884,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.63,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "ClosedOffice",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "ClosedOffice",
      "lighting_per_area": 1.727,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.75,
      "occupancy_schedule": "Office Work Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.87,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Conference",
      "lighting_per_area": 1.84,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.785,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Office Work Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.29,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 2.355,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "IT_Room",
      "lighting_per_area": 1.55,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 2.04,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "OpenOffice",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "OpenOffice",
      "lighting_per_area": 1.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.25,
      "occupancy_schedule": "Office Work Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.96,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "PrintRoom",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "PrintRoom",
      "lighting_per_area": 1.55,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Restroom",
      "lighting_per_area": 1.41,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Medium Office Bldg Occ",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Stair",
      "lighting_per_area": 0.942,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 1.27,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "Vending",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Vending",
      "lighting_per_area": 1.57,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.85,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "WholeBuilding - Lg Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "WholeBuilding - Lg Office",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Large Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Large Office Bldg Occ",
      "occupancy_activity_schedule": "Large Office Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Large Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Large Office Bldg Equip",
      "heating_setpoint_schedule": "Large Office HtgSetp",
      "cooling_setpoint_schedule": "Large Office ClgSetp",
      "service_water_heating_peak_flow_rate": 63.9,
      "service_water_heating_area": 498588.0,
      "service_water_heating_peak_flow_per_area": 0.0001281619293,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Office SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "WholeBuilding - Md Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "WholeBuilding - Md Office",
      "lighting_per_area": 1.57,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Medium Office Bldg Occ",
      "occupancy_activity_schedule": "Medium Office Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Medium Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Medium Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": 29.67,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0005532557619,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Medium Office Bldg Swh",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Office",
      "space_type": "WholeBuilding - Sm Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "WholeBuilding - Sm Office",
      "lighting_per_area": 1.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Small Office Bldg Occ",
      "occupancy_activity_schedule": "Small Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Small Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Small Office Bldg Equip",
      "heating_setpoint_schedule": "Small Office HtgSetp",
      "cooling_setpoint_schedule": "Small Office ClgSetp",
      "service_water_heating_peak_flow_rate": 3.0,
      "service_water_heating_area": 5502.0,
      "service_water_heating_peak_flow_per_area": 0.0005452562704,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Office SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Anesthesia",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Anesthesia",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Nursery, Exam",
      "ventilation_per_area": 0.45,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 8.0,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.009259259259,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": 1.3333346236599153,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 54.520672421626536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "BioHazard",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "BioHazard",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Bedpan Room",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Cafe",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 92.9,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "CleanWork",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "CleanWork",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Utility / Workroom",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 4.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Conference",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 46.45,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "DressingRoom",
      "rgb": "136_78_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "DressingRoom",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "ElevatorPumpRoom",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.1,
      "electric_equipment_fraction_lost": 0.9,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Exam",
      "rgb": "136_78_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Exam",
      "lighting_per_area": 1.6000000000000003,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Hall",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Hall",
      "lighting_per_area": 0.8000000000000002,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Hall_infil",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Hall",
      "lighting_per_area": 0.8000000000000002,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "IT_Room",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Telecommunication centers and data entry areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Janitor",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Janitor",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.9,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "LockerRoom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "LockerRoom",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Lounge",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Lounge",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "MRI",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "MRI",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 53.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Radiology Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 440.0,
      "service_water_heating_peak_flow_per_area": 0.002272727273,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 166.5909435105255,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "MRI_Control",
      "rgb": "136_78_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "MRI_Control",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 168.0,
      "service_water_heating_peak_flow_per_area": 0.005952380952,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 63.6074511585643,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "MedGas",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "MedGas",
      "lighting_per_area": 1.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "NurseStation",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "NurseStation",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "OR",
      "lighting_per_area": 7.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Patient rooms",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 15.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": 23.87,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.0,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "Outpatient Bldg Equip",
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient OR HtgSetp",
      "cooling_setpoint_schedule": "Outpatient OR ClgSetp",
      "service_water_heating_peak_flow_rate": 6.0,
      "service_water_heating_area": 472.0,
      "service_water_heating_peak_flow_per_area": 0.01271186441,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "PACU",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "PACU",
      "lighting_per_area": 2.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.333,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 316.0,
      "service_water_heating_peak_flow_per_area": 0.003164556962,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "PhysicalTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "PhysicalTherapy",
      "lighting_per_area": 1.6000000000000003,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 946,
      "service_water_heating_peak_flow_per_area": 0.001057082452,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "PreOp",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "PreOp",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.333,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 263.5,
      "service_water_heating_peak_flow_per_area": 0.003795066414,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "ProcedureRoom",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "ProcedureRoom",
      "lighting_per_area": 1.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Patient rooms",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 15.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 285.0,
      "service_water_heating_peak_flow_per_area": 0.00350877193,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Reception",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.9,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Soil Work",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Soil Work",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Soil work Outpatient",
      "ventilation_per_area": 0.556,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748944,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 79.50931394820536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Stair",
      "lighting_per_area": 0.8000000000000002,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": 1.0,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Toilet",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Toilet",
      "lighting_per_area": 0.8000000000000002,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.7,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748942,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 34.075420263516584,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Undeveloped",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-1999",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Outpatient",
      "space_type": "Xray",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Xray",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Radiology Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 900.0,
      "service_water_heating_peak_flow_per_area": 0.001111111111,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Cafeteria",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 66.67,
      "occupancy_schedule": "PrimarySchool Cafeteria Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Classroom",
      "lighting_per_area": 2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Classroom",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 23.22,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Gym",
      "lighting_per_area": 1.07,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.9,
      "occupancy_schedule": "PrimarySchool Gym Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": 302.6,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "PrimarySchool Kitchen Gas",
      "electric_equipment_per_area": 17.7,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "PrimarySchool Kitchen Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": 100.0,
      "service_water_heating_area": 1808.0,
      "service_water_heating_peak_flow_per_area": 0.05530973451,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "PrimarySchool SWH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 572.9644137011418,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "PrimarySchool Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "SchoolPrimary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 2.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Libraries",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 21.36,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1.14,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Mechanical",
      "lighting_per_area": 0.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "PrimarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Restroom",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": 56.5,
      "service_water_heating_area": 2045.0,
      "service_water_heating_peak_flow_per_area": 0.02762836186,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "PrimarySchool SWH",
      "exhaust_per_area": 0.293378304967726,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 104.17534794566214,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": 1.0,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "QuickServiceRestaurant",
      "lighting_secondary_space_type": "Dining",
      "lighting_per_area": 1.44,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "QuickServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "QuickServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "QuickServiceRestaurant Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "QuickServiceRestaurant Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 12.0,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp",
      "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "QuickServiceRestaurant",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.55,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "QuickServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "QuickServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "QuickServiceRestaurant Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "QuickServiceRestaurant Infil Half On",
      "gas_equipment_per_area": 409.6,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "QuickServiceRestaurant Gas Equip",
      "electric_equipment_per_area": 28.0,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.3,
      "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp Kitchen",
      "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp Kitchen",
      "service_water_heating_peak_flow_rate": 40.0,
      "service_water_heating_area": 1250.0,
      "service_water_heating_peak_flow_per_area": 0.032,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "QuickServiceRestaurant Bldg Swh",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 575.7279076578998,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "QuickServiceRestaurant Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Retail",
      "space_type": "Back_Space",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "Back_Space",
      "lighting_per_area": 1.16593,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Retail",
      "space_type": "Entry",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "Entry",
      "lighting_per_area": 3.36774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail FRONT ENTRY COOLING",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Retail",
      "space_type": "Point_of_Sale",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "Point_of_Sale",
      "lighting_per_area": 3.36774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Retail",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 3.36774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Clothiers, furniture",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Auditorium",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Auditorium",
      "lighting_per_area": 1.12,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Auditorium",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 92.94,
      "occupancy_schedule": "SecondarySchool Auditorium Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Cafeteria",
      "lighting_per_area": 1.34,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 66.84,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.79,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Kitchen Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Classroom",
      "lighting_per_area": 2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Classroom",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 23.22,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.86,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.31,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Gym",
      "lighting_per_area": 1.06,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 92.94,
      "occupancy_schedule": "SecondarySchool Gym Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Gym - audience",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Gym",
      "lighting_per_area": 1.06,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.9,
      "occupancy_schedule": "SecondarySchool Gym Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.56,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.48,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": 354.9,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SecondarySchool Kitchen Gas",
      "electric_equipment_per_area": 20.65,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SecondarySchool Kitchen Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 2325.0,
      "service_water_heating_peak_flow_per_area": 0.05720430108,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SecondarySchool Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "SchoolSecondary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.52,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Libraries",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 21.34,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Mechanical",
      "lighting_per_area": 0.75,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.87,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "SecondarySchool Office Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SecondarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Restroom",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": 52.2,
      "service_water_heating_area": 2260.0,
      "service_water_heating_peak_flow_per_area": 0.02309734513,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.2812153843741127,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 110.36763444376396,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Attic",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.86,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 198.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Exercise",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Exercise",
      "lighting_per_area": 1.37,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Exercise Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 31.33,
      "occupancy_schedule": "SmallHotel Exercise Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.07,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Exercise Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "GuestLounge",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "GuestLounge",
      "lighting_per_area": 1.31,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel StaffLounge Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.43,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.74,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel GuestRoom Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Living rooms",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.97,
      "occupancy_schedule": "SmallHotel GuestRoom Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel GuestRoom Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": 1.75,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.004985754986,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Laundry",
      "lighting_per_area": 1.04,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Laundry Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Dry Cleaners, Laundries",
      "ventilation_secondary_space_type": "Commercial Laundry",
      "ventilation_per_area": 0,
      "ventilation_per_person": 25,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SmallHotel Laundry Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": 58.4,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "SmallHotel Laundry Gas",
      "electric_equipment_per_area": 2.03,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Laundry Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": 67.5,
      "service_water_heating_area": 1053.0,
      "service_water_heating_peak_flow_per_area": 0.0641025641,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Mechanical",
      "lighting_per_area": 0.96,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Meeting",
      "lighting_per_area": 2.13,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Meeting Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "SmallHotel Meeting Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Meeting Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 2.01,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Office Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "SmallHotel Office Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Office Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "PublicRestroom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "PublicRestroom",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.85,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.139566144206643,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 69.45023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "StaffLounge",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "StaffLounge",
      "lighting_per_area": 1.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel StaffLounge Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 31.34,
      "occupancy_schedule": "SmallHotel StaffLounge Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 7.17,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel StaffLounge Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Stair",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SmallHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.45,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Storage Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 1",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "StripMall",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 5.5983371904,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "StripMall Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "StripMall Bldg Occ",
      "occupancy_activity_schedule": "StripMall Activity",
      "infiltration_per_exterior_area": 0.22303105,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "StripMall Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "StripMall Bldg Equip",
      "heating_setpoint_schedule": "StripMall HtgSetp",
      "cooling_setpoint_schedule": "StripMall ClgSetp",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 2",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "StripMall",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 3.2989869504,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "StripMall Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "StripMall Bldg Occ",
      "occupancy_activity_schedule": "StripMall Activity",
      "infiltration_per_exterior_area": 0.22303105,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "StripMall Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "StripMall Bldg Equip",
      "heating_setpoint_schedule": "StripMall HtgSetp",
      "cooling_setpoint_schedule": "StripMall ClgSetp",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 3",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "StripMall",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 2.698833312,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "StripMall Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "StripMall Bldg Occ",
      "occupancy_activity_schedule": "StripMall Activity",
      "infiltration_per_exterior_area": 0.22303105,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "StripMall Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "StripMall Bldg Equip",
      "heating_setpoint_schedule": "StripMall HtgSetp",
      "cooling_setpoint_schedule": "StripMall ClgSetp",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SuperMarket",
      "space_type": "Deli/Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SuperMarket",
      "lighting_secondary_space_type": "Deli/Bakery",
      "lighting_per_area": 2.78,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": 8.53,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SuperMarket",
      "space_type": "DryStorage",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SuperMarket",
      "lighting_secondary_space_type": "DryStorage",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Shipping and receiving",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SuperMarket",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SuperMarket",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.98,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "SuperMarket",
      "space_type": "Sales/Produce",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SuperMarket",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 2.78,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Warehouse",
      "space_type": "Bulk",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Bulk",
      "lighting_per_area": 0.3102962,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Warehouse Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse Bldg Occ",
      "occupancy_activity_schedule": "Warehouse Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2378318,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse HtgSetp BulkStorage",
      "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Warehouse",
      "space_type": "Fine",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Fine",
      "lighting_per_area": 1.0813914,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Warehouse Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse Bldg Occ",
      "occupancy_activity_schedule": "Warehouse Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse HtgSetp FineStorage",
      "cooling_setpoint_schedule": "Warehouse ClgSetp FineStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "building_type": "Warehouse",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 2.0150669,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Warehouse Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.96,
      "occupancy_schedule": "Warehouse Bldg Occ",
      "occupancy_activity_schedule": "Warehouse Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.7497275,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse HtgSetp",
      "cooling_setpoint_schedule": "Warehouse Cooling Setpoint",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "FullServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "FullServiceRestaurant",
      "lighting_secondary_space_type": "Dining",
      "lighting_per_area": 2.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "FullServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining Rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "FullServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "FullServiceRestaurant Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "FullServiceRestaurant Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.6,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp",
      "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "FullServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "FullServiceRestaurant",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.52,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "FullServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "FullServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "FullServiceRestaurant Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "FullServiceRestaurant Infil Half On",
      "gas_equipment_per_area": 378.75,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "FullServiceRestaurant Gas Equip",
      "electric_equipment_per_area": 35.0,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "FullServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "FullServiceRestaurant HtgSetp Kitchen",
      "cooling_setpoint_schedule": "FullServiceRestaurant ClgSetp Kitchen",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1501.0,
      "service_water_heating_peak_flow_per_area": 0.08860759494,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "FullServiceRestaurant Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "RestaurantSitDown Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "Basement",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Basement",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Basement",
      "ventilation_secondary_space_type": "For Hospital",
      "ventilation_per_area": "",
      "ventilation_per_person": 21.186,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.5,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.749,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 1.355,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Dining",
      "lighting_per_area": 2.575,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Dining Rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "ER_Exam",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ER_Exam",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5000000000000002,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "ER_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ER_NurseStn",
      "lighting_per_area": 1.66,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.25,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "ER_Trauma",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ER_Trauma",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "ER_Triage",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ER_Triage",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.67,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "ICU_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ICU_NurseStn",
      "lighting_per_area": 1.71,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "ICU_Open",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ICU_Open",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0000000000000004,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "ICU_PatRm",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "ICU_PatRm",
      "lighting_per_area": 3.841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Recovery and ICU",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0000000000000004,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical HtgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.42,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Kitchen",
      "ventilation_per_area": 0.371,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": 96.7,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "Hospital Kitchen Gas",
      "electric_equipment_per_area": 7.5,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "Hospital Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 150.0,
      "service_water_heating_area": 10000.0,
      "service_water_heating_peak_flow_per_area": 0.015,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 924.6539123,
      "exhaust_fan_pressure_rise": 0.5024115756,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Hospital Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "Lab",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Lab",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Laboratories",
      "ventilation_per_area": 1.4,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 2850.0,
      "service_water_heating_peak_flow_per_area": 0.000701754386,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "Lobby",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1.03,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.09999999999999999,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "NurseStn",
      "lighting_per_area": 1.458,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.04,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "OR",
      "lighting_per_area": 9.745,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Operating rooms",
      "ventilation_per_area": 0.7,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical ClgSetp",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 600.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 2.395,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.99,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "PatCorridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "PatCorridor",
      "lighting_per_area": 1.32,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "PatRoom",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "PatRoom",
      "lighting_per_area": 2.188,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Critical Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Patient rooms",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Critical Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Critical Equip",
      "heating_setpoint_schedule": "Hospital Critical HtgSetp",
      "cooling_setpoint_schedule": "Hospital Critical ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 280.0,
      "service_water_heating_peak_flow_per_area": 0.003571428571,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "PhysTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "PhysTherapy",
      "lighting_per_area": 2.51,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5280.0,
      "service_water_heating_peak_flow_per_area": 0.0001893939394,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Hospital",
      "space_type": "Radiology",
      "rgb": "136_78_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Radiology",
      "lighting_per_area": 2.21,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital Admin Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Radiology",
      "ventilation_per_area": 0.7,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital Bldg Occ",
      "occupancy_activity_schedule": "Hospital Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital Admin Equipment",
      "heating_setpoint_schedule": "Hospital Bldg HtgSetp",
      "cooling_setpoint_schedule": "Hospital Bldg ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5250.0,
      "service_water_heating_peak_flow_per_area": 0.0001904761905,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital SWH Extd",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Banquet",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Banquet",
      "lighting_per_area": 2.56,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dining rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 21.2,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 1.0,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 1.0e-05,
      "exhaust_fan_maximum_flow_rate": 2000.0,
      "exhaust_schedule": "Always On",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Basement",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Basement",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.5,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Cafe",
      "lighting_per_area": 2.56,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 67.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 1.22,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Corridor2",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 1.22,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel Corridor HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel Corridor ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "LargeHotel GuestRoom Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel GuestRoom Equip",
      "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom2",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "LargeHotel GuestRoom Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel GuestRoom Equip",
      "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp",
      "service_water_heating_peak_flow_rate": 23.743,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.08993560606,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom3",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "LargeHotel GuestRoom Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel GuestRoom Equip",
      "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom4",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel GuestRoom_Ltg_Sch_Base",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Dormitory sleeping areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.68,
      "occupancy_schedule": "LargeHotel GuestRoom Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel GuestRoom Equip",
      "heating_setpoint_schedule": "LargeHotel GuestRoom HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel GuestRoom ClgSetp",
      "service_water_heating_peak_flow_rate": 11.247,
      "service_water_heating_area": 264.0,
      "service_water_heating_peak_flow_per_area": 0.04260227273,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.56,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": 511.0,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "LargeHotel Kitchen Gas",
      "electric_equipment_per_area": 47.1989,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "LargeHotel Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "LargeHotel Kitchen HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel Kitchen ClgSetp",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1112.0,
      "service_water_heating_peak_flow_per_area": 0.1196043165,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 1.0,
      "exhaust_fan_power": 698.0,
      "exhaust_fan_pressure_rise": 1.0e-05,
      "exhaust_fan_maximum_flow_rate": 94.2477825,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Laundry",
      "lighting_per_area": 1.14,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Dry Cleaners, Laundries",
      "ventilation_secondary_space_type": "Commercial Laundry",
      "ventilation_per_area": 0,
      "ventilation_per_person": 25,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": 170.0,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "LargeHotel LaundryRoom Gas",
      "electric_equipment_per_area": 5.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel LaundryRoom Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": 156.6,
      "service_water_heating_area": 840.0,
      "service_water_heating_peak_flow_per_area": 0.1864285714,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch_Pre2004",
      "exhaust_per_area": 0.5952276390725688,
      "exhaust_fan_efficiency": 0.34,
      "exhaust_fan_power": 87.0,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 500.055681,
      "exhaust_schedule": "Always On",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1.88,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.7500000000000001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Mechanical",
      "lighting_per_area": 0.8000000000000002,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 3.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Retail2",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 3.54,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "LargeHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "LargeHotel",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.37,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "LargeHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Shipping and receiving",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.0,
      "occupancy_schedule": "LargeHotel Common Occ",
      "occupancy_activity_schedule": "LargeHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "LargeHotel Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.24999999999999997,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "LargeHotel Bldg Equip",
      "heating_setpoint_schedule": "LargeHotel HtgSetp",
      "cooling_setpoint_schedule": "LargeHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "MidriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "MidriseApartment Apartment Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 36,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "MidriseApartment Apartment Occ",
      "occupancy_activity_schedule": "MidriseApartment Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "MidriseApartment Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "MidriseApartment Apartment HtgSetp",
      "cooling_setpoint_schedule": "MidriseApartment Apartment ClgSetp",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "MidriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.92,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "MidriseApartment Corridor Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "MidriseApartment Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS Pre2004",
      "heating_setpoint_schedule": "MidriseApartment UnitHeater HtgSP Sch",
      "cooling_setpoint_schedule": "MidriseApartment UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "MidriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 2.04,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "MidriseApartment Office Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "MidriseApartment Office Occ",
      "occupancy_activity_schedule": "MidriseApartment Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "MidriseApartment OFFICE Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_Pre2004",
      "heating_setpoint_schedule": "MidriseApartment Office HtgSetp",
      "cooling_setpoint_schedule": "MidriseApartment Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": null,
      "lighting_primary_space_type": null,
      "lighting_secondary_space_type": null,
      "lighting_per_area": null,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": "#N/A",
      "ventilation_per_person": "#N/A",
      "ventilation_air_changes": "#N/A",
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Small Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "BreakRoom",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "BreakRoom",
      "lighting_per_area": 2.28,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.63,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "ClosedOffice",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "ClosedOffice",
      "lighting_per_area": 2.09,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.75,
      "occupancy_schedule": "Office Work Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.87,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Conference",
      "lighting_per_area": 2.47,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Office Work Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.29,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 2.85,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "IT_Room",
      "lighting_per_area": 2.09,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 2.47,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Reception Areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "OpenOffice",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "OpenOffice",
      "lighting_per_area": 2.09,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.25,
      "occupancy_schedule": "Office Work Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.96,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "PrintRoom",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "PrintRoom",
      "lighting_per_area": 1.881,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Restroom",
      "lighting_per_area": 1.71,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Medium Office Bldg Occ",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Stair",
      "lighting_per_area": 1.14,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 1.539,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "Vending",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "Vending",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Office Misc Occ",
      "occupancy_activity_schedule": "Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.85,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "WholeBuilding - Lg Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "WholeBuilding - Lg Office",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Large Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Large Office Bldg Occ",
      "occupancy_activity_schedule": "Large Office Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Large Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Large Office Bldg Equip",
      "heating_setpoint_schedule": "Large Office HtgSetp",
      "cooling_setpoint_schedule": "Large Office ClgSetp",
      "service_water_heating_peak_flow_rate": 63.9,
      "service_water_heating_area": 498588.0,
      "service_water_heating_peak_flow_per_area": 0.0001281619293,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Office SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "WholeBuilding - Md Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "WholeBuilding - Md Office",
      "lighting_per_area": 1.57,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Medium Office Bldg Occ",
      "occupancy_activity_schedule": "Medium Office Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Medium Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Medium Office Bldg Equip",
      "heating_setpoint_schedule": "Medium Office HtgSetp",
      "cooling_setpoint_schedule": "Medium Office ClgSetp",
      "service_water_heating_peak_flow_rate": 29.67,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0005532557619,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Medium Office Bldg Swh",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Office",
      "space_type": "WholeBuilding - Sm Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "WholeBuilding - Sm Office",
      "lighting_per_area": 1.81,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Office Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Small Office Bldg Occ",
      "occupancy_activity_schedule": "Small Office Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Small Office Infil Quarter On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Small Office Bldg Equip",
      "heating_setpoint_schedule": "Small Office HtgSetp",
      "cooling_setpoint_schedule": "Small Office ClgSetp",
      "service_water_heating_peak_flow_rate": 3.0,
      "service_water_heating_area": 5502.0,
      "service_water_heating_peak_flow_per_area": 0.0005452562704,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Office SWH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Anesthesia",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Anesthesia",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Nursery, Exam",
      "ventilation_per_area": 0.45,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 8.0,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.009259259259,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": 1.3333346236599153,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 54.520672421626536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "BioHazard",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "BioHazard",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Bedpan Room",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Cafe",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 92.9,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "CleanWork",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "CleanWork",
      "lighting_per_area": 1.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Utility / Workroom",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 4.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Conference",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 46.45,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "DressingRoom",
      "rgb": "136_78_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "DressingRoom",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "ElevatorPumpRoom",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.1,
      "electric_equipment_fraction_lost": 0.9,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Exam",
      "rgb": "136_78_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Exam",
      "lighting_per_area": 1.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Hall",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Hall",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Hall_infil",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Hall",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "IT_Room",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Telecommunication centers and data entry areas",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Janitor",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Janitor",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.9,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "LockerRoom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "LockerRoom",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Lounge",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Lounge",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "MRI",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "MRI",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 53.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Radiology Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 440.0,
      "service_water_heating_peak_flow_per_area": 0.002272727273,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 166.5909435105255,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "MRI_Control",
      "rgb": "136_78_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "MRI_Control",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 168.0,
      "service_water_heating_peak_flow_per_area": 0.005952380952,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 63.6074511585643,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "MedGas",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "MedGas",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "NurseStation",
      "rgb": "31_162_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "NurseStation",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "OR",
      "lighting_per_area": 7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Patient rooms",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 15.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": 23.87,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.0,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "Outpatient Bldg Equip",
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient OR HtgSetp",
      "cooling_setpoint_schedule": "Outpatient OR ClgSetp",
      "service_water_heating_peak_flow_rate": 6.0,
      "service_water_heating_area": 472.0,
      "service_water_heating_peak_flow_per_area": 0.01271186441,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "PACU",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "PACU",
      "lighting_per_area": 2.3,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.333,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 316.0,
      "service_water_heating_peak_flow_per_area": 0.003164556962,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "PhysicalTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "PhysicalTherapy",
      "lighting_per_area": 1.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 946,
      "service_water_heating_peak_flow_per_area": 0.001057082452,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "PreOp",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "PreOp",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.333,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 6.0,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 263.5,
      "service_water_heating_peak_flow_per_area": 0.003795066414,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "ProcedureRoom",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "ProcedureRoom",
      "lighting_per_area": 1.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Patient rooms",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 15.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 285.0,
      "service_water_heating_peak_flow_per_area": 0.00350877193,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Reception",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.9,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Soil Work",
      "rgb": "204_120_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Soil Work",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Soil work Outpatient",
      "ventilation_per_area": 0.556,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": 10.0,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748944,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 79.50931394820536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Stair",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": 1.0,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Toilet",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Toilet",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.7,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748942,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 34.075420263516584,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Outpatient_FirstFlr_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Undeveloped",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 90.1-1999",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "Outpatient Bldg Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Outpatient",
      "space_type": "Xray",
      "rgb": "169_31_159",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Outpatient",
      "lighting_secondary_space_type": "Xray",
      "lighting_per_area": 2.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Outpatient Bldg Light",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "Outpatient Bldg Occ",
      "occupancy_activity_schedule": "Outpatient Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Outpatient Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Outpatient Radiology Equip",
      "heating_setpoint_schedule": "Outpatient HtgSetp",
      "cooling_setpoint_schedule": "Outpatient ClgSetp",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 900.0,
      "service_water_heating_peak_flow_per_area": 0.001111111111,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH_Pre2004",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Cafeteria",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 66.67,
      "occupancy_schedule": "PrimarySchool Cafeteria Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Classroom",
      "lighting_per_area": 2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Classroom",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 23.22,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Gym",
      "lighting_per_area": 1.07,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.9,
      "occupancy_schedule": "PrimarySchool Gym Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.6,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": 302.6,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "PrimarySchool Kitchen Gas",
      "electric_equipment_per_area": 17.7,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "PrimarySchool Kitchen Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": 100.0,
      "service_water_heating_area": 1808.0,
      "service_water_heating_peak_flow_per_area": 0.05530973451,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "PrimarySchool SWH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 572.9644137011418,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "PrimarySchool Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "SchoolPrimary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 2.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Libraries",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 21.36,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1.14,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Mechanical",
      "lighting_per_area": 0.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "PrimarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "PrimarySchool",
      "lighting_secondary_space_type": "Restroom",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "PrimarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "PrimarySchool Bldg Occ",
      "occupancy_activity_schedule": "PrimarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "PrimarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "PrimarySchool Bldg Equip",
      "heating_setpoint_schedule": "PrimarySchool BathCorrMechKitchen HtgSetp",
      "cooling_setpoint_schedule": "PrimarySchool BathCorrMechKitchen ClgSetp",
      "service_water_heating_peak_flow_rate": 56.5,
      "service_water_heating_area": 2045.0,
      "service_water_heating_peak_flow_per_area": 0.02762836186,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "PrimarySchool SWH",
      "exhaust_per_area": 0.293378304967726,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 104.17534794566214,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "QuickServiceRestaurant",
      "lighting_secondary_space_type": "Dining",
      "lighting_per_area": 3.7,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "QuickServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "QuickServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "QuickServiceRestaurant Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "QuickServiceRestaurant Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 12.0,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp",
      "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "QuickServiceRestaurant",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 2.24,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "QuickServiceRestaurant Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "QuickServiceRestaurant Bldg Occ",
      "occupancy_activity_schedule": "QuickServiceRestaurant Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.223,
      "infiltration_air_changes": null,
      "infiltration_schedule": "QuickServiceRestaurant Infil Half On",
      "gas_equipment_per_area": 409.6,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "QuickServiceRestaurant Gas Equip",
      "electric_equipment_per_area": 28.0,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.3,
      "electric_equipment_schedule": "QuickServiceRestaurant Bldg Equip",
      "heating_setpoint_schedule": "QuickServiceRestaurant HtgSetp Kitchen",
      "cooling_setpoint_schedule": "QuickServiceRestaurant ClgSetp Kitchen",
      "service_water_heating_peak_flow_rate": 40.0,
      "service_water_heating_area": 1250.0,
      "service_water_heating_peak_flow_per_area": 0.032,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "QuickServiceRestaurant Bldg Swh",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 575.7279076578998,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "QuickServiceRestaurant Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Retail",
      "space_type": "Back_Space",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "Back_Space",
      "lighting_per_area": 1.16593,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Retail",
      "space_type": "Entry",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "Entry",
      "lighting_per_area": 3.36774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail FRONT ENTRY COOLING",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Retail",
      "space_type": "Point_of_Sale",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "Point_of_Sale",
      "lighting_per_area": 3.36774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Retail",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 3.36774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Retail Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Clothiers, furniture",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "Retail Bldg Occ",
      "occupancy_activity_schedule": "Retail Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Retail Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Retail Bldg Equip",
      "heating_setpoint_schedule": "Retail HtgSetp",
      "cooling_setpoint_schedule": "Retail ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Auditorium",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Auditorium",
      "lighting_per_area": 1.12,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Auditorium",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 92.94,
      "occupancy_schedule": "SecondarySchool Auditorium Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Cafeteria",
      "lighting_per_area": 1.34,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria, fast food",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 66.84,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.79,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Kitchen Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Classroom",
      "lighting_per_area": 2,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Classroom",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 23.22,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.86,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.31,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Gym",
      "lighting_per_area": 1.06,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 92.94,
      "occupancy_schedule": "SecondarySchool Gym Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Gym - audience",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Gym",
      "lighting_per_area": 1.06,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 27.9,
      "occupancy_schedule": "SecondarySchool Gym Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Kitchen",
      "lighting_per_area": 1.56,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Kitchens (cooking)",
      "ventilation_per_area": 0.47,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.48,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": 354.9,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SecondarySchool Kitchen Gas",
      "electric_equipment_per_area": 20.65,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SecondarySchool Kitchen Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 2325.0,
      "service_water_heating_peak_flow_per_area": 0.05720430108,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SecondarySchool Kitchen Exhaust",
      "balanced_exhaust_fraction_schedule": "SchoolSecondary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.52,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Libraries",
      "ventilation_per_area": 0,
      "ventilation_per_person": 16.95,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 21.34,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Lobby",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Education",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.1,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Mechanical",
      "lighting_per_area": 0.75,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 1.87,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "SecondarySchool Office Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SecondarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SecondarySchool",
      "lighting_secondary_space_type": "Restroom",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SecondarySchool Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms (Assume 12 toilet/625 ft^2)",
      "ventilation_per_area": 0.96,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "SecondarySchool Bldg Occ",
      "occupancy_activity_schedule": "SecondarySchool Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SecondarySchool Infil",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SecondarySchool Bldg Equip",
      "heating_setpoint_schedule": "SecondarySchool HtgSetp BathCorrMechKitchen",
      "cooling_setpoint_schedule": "SecondarySchool ClgSetp BathCorrMechKitchen",
      "service_water_heating_peak_flow_rate": 52.2,
      "service_water_heating_area": 2260.0,
      "service_water_heating_peak_flow_per_area": 0.02309734513,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.2812153843741127,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 110.36763444376396,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref 1980-2004",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Attic",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Corridor",
      "lighting_per_area": 0.86,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_172",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Elec/MechRoom",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 198.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "ElevatorCore",
      "rgb": "41_31_172",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "ElevatorCore",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel BLDG ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Exercise",
      "rgb": "154_230_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Exercise",
      "lighting_per_area": 1.37,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Exercise Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Sports and Amusement",
      "ventilation_secondary_space_type": "Playing floors (gymnasium)",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 31.33,
      "occupancy_schedule": "SmallHotel Exercise Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.07,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Exercise Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "GuestLounge",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "GuestLounge",
      "lighting_per_area": 1.31,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel StaffLounge Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.43,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "GuestRoom",
      "lighting_per_area": 1.74,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel GuestRoom Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Living rooms",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.97,
      "occupancy_schedule": "SmallHotel GuestRoom Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.33,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel GuestRoom Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": 1.75,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.004985754986,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Laundry",
      "lighting_per_area": 1.04,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Laundry Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Dry Cleaners, Laundries",
      "ventilation_secondary_space_type": "Commercial Laundry",
      "ventilation_per_area": 0,
      "ventilation_per_person": 25,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SmallHotel Laundry Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": 58.4,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "SmallHotel Laundry Gas",
      "electric_equipment_per_area": 2.03,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Laundry Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": 67.5,
      "service_water_heating_area": 1053.0,
      "service_water_heating_peak_flow_per_area": 0.0641025641,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Mechanical",
      "lighting_per_area": 0.96,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Corridors and utilities",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Meeting",
      "lighting_per_area": 2.13,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Meeting Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Conference rooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "SmallHotel Meeting Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Meeting Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 2.01,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Office Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "SmallHotel Office Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Office Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "PublicRestroom",
      "rgb": "169_169_31",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "PublicRestroom",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.85,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.139566144206643,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 69.45023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "StaffLounge",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "StaffLounge",
      "lighting_per_area": 1.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel StaffLounge Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 31.34,
      "occupancy_schedule": "SmallHotel StaffLounge Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 7.17,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel StaffLounge Equip",
      "heating_setpoint_schedule": "SmallHotel HtgSetp",
      "cooling_setpoint_schedule": "SmallHotel ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Stair",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Always On",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SmallHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SmallHotel",
      "lighting_secondary_space_type": "Storage",
      "lighting_per_area": 0.45,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SmallHotel Storage Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SmallHotel Bldg Occ",
      "occupancy_activity_schedule": "SmallHotel Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SmallHotel Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SmallHotel Bldg Equip",
      "heating_setpoint_schedule": "SmallHotel UnitHeater HtgSP Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 1",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "StripMall",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 5.5983371904,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "StripMall Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "StripMall Bldg Occ",
      "occupancy_activity_schedule": "StripMall Activity",
      "infiltration_per_exterior_area": 0.22303105,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "StripMall Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "StripMall Bldg Equip",
      "heating_setpoint_schedule": "StripMall HtgSetp",
      "cooling_setpoint_schedule": "StripMall ClgSetp",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 2",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "StripMall",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 3.2989869504,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "StripMall Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "StripMall Bldg Occ",
      "occupancy_activity_schedule": "StripMall Activity",
      "infiltration_per_exterior_area": 0.22303105,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "StripMall Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "StripMall Bldg Equip",
      "heating_setpoint_schedule": "StripMall HtgSetp",
      "cooling_setpoint_schedule": "StripMall ClgSetp",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 3",
      "rgb": "171_222_78",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "StripMall",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 2.698833312,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "StripMall Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Basement and street",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "StripMall Bldg Occ",
      "occupancy_activity_schedule": "StripMall Activity",
      "infiltration_per_exterior_area": 0.22303105,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "StripMall Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "StripMall Bldg Equip",
      "heating_setpoint_schedule": "StripMall HtgSetp",
      "cooling_setpoint_schedule": "StripMall ClgSetp",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SuperMarket",
      "space_type": "Deli/Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SuperMarket",
      "lighting_secondary_space_type": "Deli/Bakery",
      "lighting_per_area": 5.04,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": 8.53,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SuperMarket",
      "space_type": "DryStorage",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SuperMarket",
      "lighting_secondary_space_type": "DryStorage",
      "lighting_per_area": 0.77,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Shipping and receiving",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SuperMarket",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SuperMarket",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 2.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "SuperMarket",
      "space_type": "Sales/Produce",
      "rgb": "230_196_120",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "SuperMarket",
      "lighting_secondary_space_type": "Sales/Produce",
      "lighting_per_area": 5.04,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Specialty Shops",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0,
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.2232,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Warehouse",
      "space_type": "Bulk",
      "rgb": "41_31_169",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Bulk",
      "lighting_per_area": 0.3102962,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Warehouse Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse Bldg Occ",
      "occupancy_activity_schedule": "Warehouse Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.2378318,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse HtgSetp BulkStorage",
      "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Warehouse",
      "space_type": "Fine",
      "rgb": "120_149_230",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Fine",
      "lighting_per_area": 1.0813914,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Warehouse Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Retail Stores, Sales Floors, and Show Room Floors",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.05,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse Bldg Occ",
      "occupancy_activity_schedule": "Warehouse Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse HtgSetp FineStorage",
      "cooling_setpoint_schedule": "Warehouse ClgSetp FineStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "DOE Ref Pre-1980",
      "building_type": "Warehouse",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "DOE Ref Pre-1980",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 2.0150669,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Warehouse Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Offices",
      "ventilation_secondary_space_type": "Office Space",
      "ventilation_per_area": 0,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.96,
      "occupancy_schedule": "Warehouse Bldg Occ",
      "occupancy_activity_schedule": "Warehouse Activity",
      "infiltration_per_exterior_area": 0.2232,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.7497275,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse HtgSetp",
      "cooling_setpoint_schedule": "Warehouse Cooling Setpoint",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "ICC IECC 2015",
      "building_type": "MidriseApartment",
      "space_type": "Apartment",
      "rgb": null,
      "lighting_standard": null,
      "lighting_primary_space_type": null,
      "lighting_secondary_space_type": null,
      "lighting_per_area": null,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "ICC IECC 2015",
      "building_type": "MidriseApartment",
      "space_type": "Corridor",
      "rgb": null,
      "lighting_standard": null,
      "lighting_primary_space_type": null,
      "lighting_secondary_space_type": null,
      "lighting_per_area": null,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "ICC IECC 2015",
      "building_type": "MidriseApartment",
      "space_type": "Office",
      "rgb": null,
      "lighting_standard": null,
      "lighting_primary_space_type": null,
      "lighting_secondary_space_type": null,
      "lighting_per_area": null,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "NECB 2011",
      "building_type": "Automotive facility",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Automotive facility",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.817539948,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Automotive facility",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.226,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002137,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Automotive Area",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Convention centre",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Convention centre",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.077666295,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Convention centre",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.147,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 11.61,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001781,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Courthouse",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Courthouse",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.049795615,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Courthouse",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.091,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.19,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0019,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Dining - bar/lounge",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Dining - bar/lounge",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.994054255,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Dining - bar/lounge",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.005462,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Dining - cafeteria",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Dining - cafeteria",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.901151988,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Dining - cafeteria",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.005462,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Dining - family",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Dining - family",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Dining - family",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.005462,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Dormitory",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Dormitory",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.613154961,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Dormitory",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.075,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.007915,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Sleeping Area",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Exercise centre",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Exercise centre",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.882571535,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Exercise centre",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.246,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004274,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Fire station",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Fire station",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.706057228,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Fire station",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.148,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.007599,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Automotive Area",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Gymnasium",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Gymnasium",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.003344482,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Gymnasium",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.246,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004274,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Health-care clinic",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Health-care clinic",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.873281308,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Health-care clinic",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.45,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002137,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Hospital",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.207729469,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Hospital",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.45,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002137,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Hotel",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Hotel",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.003344482,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Hotel",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.079,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.009498,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Residential/Accomodation Area",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Library",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Library",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.179858789,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Library",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.143,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002137,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Historical Collections Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Manufacturing facility",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Manufacturing facility",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.105536975,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Manufacturing facility",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.211,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Industrial Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Motel",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Motel",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.882571535,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Motel",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.079,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.009498,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Residential/Accomodation Area",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Motion picture theatre",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Motion picture theatre",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.826830175,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Motion picture theatre",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.118,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 11.61,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001781,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Multi-unit residential",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Multi-unit residential",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.603864734,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Multi-unit residential",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.068,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.55,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.003958,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Residential/Accomodation Area",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Museum",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Museum",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.059085842,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Museum",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.095,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Historical Collections Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Office",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Office",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.901151988,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Office",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.079,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00171,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Parking garage",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Parking garage",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.25083612,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Parking garage",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.061,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.09,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Automotive Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Penitentiary",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Penitentiary",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.966183575,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Penitentiary",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.075,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.006332,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Sleeping Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Performing arts theatre",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Performing arts theatre",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.393534002,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Performing arts theatre",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.118,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 11.61,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001781,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Police station",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Police station",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.956893348,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Police station",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.079,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00171,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Post office",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Post office",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.873281308,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Post office",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.148,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00171,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Religious",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Religious",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.049795615,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Religious",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.153,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Retail",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.402824229,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.083,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000633,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "School/university",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "School/university",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.994054255,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "School/university",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.147,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 11.61,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.003562,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "- undefined -",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "- undefined -",
      "lighting_per_area": 0.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "- undefined -",
      "necb_schedule_type": "- undefined -"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Atrium - H < 13m",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Atrium - H < 13m",
      "lighting_per_area": 0.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Atrium - H < 13m",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Atrium - H > 13m",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Atrium - H > 13m",
      "lighting_per_area": 0.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Atrium - H > 13m",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Audience - auditorium",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Audience - auditorium",
      "lighting_per_area": 0.789669268,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Audience - auditorium",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002839298,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Audience - motion picture",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Audience - motion picture",
      "lighting_per_area": 1.142697882,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Audience - motion picture",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002839298,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Audience - performance arts",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Audience - performance arts",
      "lighting_per_area": 2.434039391,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Audience - performance arts",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 12.39,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001893375,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Automotive - repair",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Automotive - repair",
      "lighting_per_area": 0.668896321,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Automotive - repair",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Automotive Area",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Bank - banking and offices",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Bank - banking and offices",
      "lighting_per_area": 1.384243776,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Bank - banking and offices",
      "ventilation_per_area": 0.173,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001142515,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Classroom/lecture/training",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Classroom/lecture/training",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Classroom/lecture/training",
      "ventilation_per_area": 0.548,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 12.39,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004120874,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Conf./meet./multi-purpose",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Conf./meet./multi-purpose",
      "lighting_per_area": 1.226309922,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Conf./meet./multi-purpose",
      "ventilation_per_area": 0.31,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004286783,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Convention centre - audience",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Convention centre - audience",
      "lighting_per_area": 0.817539948,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Convention centre - audience",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002839298,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Convention centre - exhibit",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Convention centre - exhibit",
      "lighting_per_area": 1.449275362,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Convention centre - exhibit",
      "ventilation_per_area": 0.17,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002839298,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. < 2.4m wide-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-A",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. < 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. < 2.4m wide-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-B",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. < 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. < 2.4m wide-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-C",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. < 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. < 2.4m wide-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-D",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. < 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. < 2.4m wide-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-E",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. < 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. < 2.4m wide-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-F",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. < 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. < 2.4m wide-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-G",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. < 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. < 2.4m wide-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-H",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. < 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. < 2.4m wide-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-I",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. < 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. >= 2.4m wide-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-A",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. >= 2.4m wide-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-B",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. >= 2.4m wide-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-C",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. >= 2.4m wide-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-D",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. >= 2.4m wide-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-E",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. >= 2.4m wide-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-F",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. >= 2.4m wide-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-G",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. >= 2.4m wide-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-H",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Corr. >= 2.4m wide-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-I",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Courthouse - cell",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Courthouse - cell",
      "lighting_per_area": 1.365663322,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Courthouse - cell",
      "ventilation_per_area": 0.245,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.006180727,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Sleeping Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Courthouse - chambers",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Courthouse - chambers",
      "lighting_per_area": 1.170568562,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Courthouse - chambers",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Courthouse - courtroom",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Courthouse - courtroom",
      "lighting_per_area": 1.718691936,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Courthouse - courtroom",
      "ventilation_per_area": 0.41,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002839298,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Dining - bar lounge/leisure",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Dining - bar lounge/leisure",
      "lighting_per_area": 1.309921962,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Dining - bar lounge/leisure",
      "ventilation_per_area": 0.705,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004272865,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Dining - family space",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Dining - family space",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Dining - family space",
      "ventilation_per_area": 0.705,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.005692514,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Dining - other",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Dining - other",
      "lighting_per_area": 0.650315868,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Dining - other",
      "ventilation_per_area": 0.705,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.005692514,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Dormitory - living quarters",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Dormitory - living quarters",
      "lighting_per_area": 0.380899294,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Dormitory - living quarters",
      "ventilation_per_area": 0.11,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.009507954,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Sleeping Area",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Dress./fitt. - performance arts",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Dress./fitt. - performance arts",
      "lighting_per_area": 0.399479747,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Dress./fitt. - performance arts",
      "ventilation_per_area": 0.233,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000631634,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Dwelling Unit(s)",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Dwelling Unit(s)",
      "lighting_per_area": 0.464511334,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Dwelling Unit(s)",
      "ventilation_per_area": 0.068,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.55,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.003961647,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Residential/Accomodation Area",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Electrical/Mechanical-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Electrical/Mechanical-sch-A",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Electrical/Mechanical",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Electrical/Mechanical-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Electrical/Mechanical-sch-B",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Electrical/Mechanical",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Electrical/Mechanical-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Electrical/Mechanical-sch-C",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Electrical/Mechanical",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Electrical/Mechanical-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Electrical/Mechanical-sch-D",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Electrical/Mechanical",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Electrical/Mechanical-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Electrical/Mechanical-sch-E",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Electrical/Mechanical",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Electrical/Mechanical-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Electrical/Mechanical-sch-F",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Electrical/Mechanical",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Electrical/Mechanical-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Electrical/Mechanical-sch-G",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Electrical/Mechanical",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Electrical/Mechanical-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Electrical/Mechanical-sch-H",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Electrical/Mechanical",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Electrical/Mechanical-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Electrical/Mechanical-sch-I",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Electrical/Mechanical",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Fire station - engine room",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Fire station - engine room",
      "lighting_per_area": 0.557413601,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Fire station - engine room",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.006180727,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Automotive Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Fire station - quarters",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Fire station - quarters",
      "lighting_per_area": 0.315867707,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Fire station - quarters",
      "ventilation_per_area": 0.16,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.009507954,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Residential/Accomodation Area",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Food preparation",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Food preparation",
      "lighting_per_area": 0.994054255,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Food preparation",
      "ventilation_per_area": 0.27,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002849321,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Food preparation - vented",
      "rgb": "255_255_256",
      "lighting_standard": "NECB 2012",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Food preparation",
      "lighting_per_area": 0.994054255,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2012",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Food preparation",
      "ventilation_per_area": 0.27,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002849321,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area - vented",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Gym - audience",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Gym - audience",
      "lighting_per_area": 0.427350427,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Gym - audience",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002839298,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Gym - fitness",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Gym - fitness",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Gym - fitness",
      "ventilation_per_area": 0.86,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00854573,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Gym - play",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Gym - play",
      "lighting_per_area": 1.198439242,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Gym - play",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1393534,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00854573,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - emergency",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - emergency",
      "lighting_per_area": 2.257525084,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - emergency",
      "ventilation_per_area": 0.6,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004277465,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - exam",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - exam",
      "lighting_per_area": 1.662950576,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - exam",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - laundry/washing",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - laundry/washing",
      "lighting_per_area": 0.743218135,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - laundry/washing",
      "ventilation_per_area": 0.45,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.858045336,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001428144,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - lounge/recreation",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - lounge/recreation",
      "lighting_per_area": 1.068376068,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - lounge/recreation",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002853216,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - medical supply",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - medical supply",
      "lighting_per_area": 1.272761055,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - medical supply",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - nursery",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - nursery",
      "lighting_per_area": 0.882571535,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - nursery",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - nurses' station",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - nurses' station",
      "lighting_per_area": 0.873281308,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - nurses' station",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001072849,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - operating room",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - operating room",
      "lighting_per_area": 1.885916016,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - operating room",
      "ventilation_per_area": 0.9,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.007133752,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - patient room",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - patient room",
      "lighting_per_area": 0.622445188,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - patient room",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - pharmacy",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - pharmacy",
      "lighting_per_area": 1.142697882,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - pharmacy",
      "ventilation_per_area": 0.45,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001072849,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - physical therapy",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - physical therapy",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - physical therapy",
      "ventilation_per_area": 0.45,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001072849,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - radiology/imaging",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - radiology/imaging",
      "lighting_per_area": 1.319212189,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - radiology/imaging",
      "ventilation_per_area": 0.45,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital - recovery",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital - recovery",
      "lighting_per_area": 1.151988109,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital - recovery",
      "ventilation_per_area": 0.9,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004277465,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. < 2.4m-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-A",
      "lighting_per_area": 1.086956522,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. < 2.4m-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-B",
      "lighting_per_area": 1.086956522,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. < 2.4m-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-C",
      "lighting_per_area": 1.086956522,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. < 2.4m-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-D",
      "lighting_per_area": 1.086956522,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. < 2.4m-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-E",
      "lighting_per_area": 1.086956522,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. < 2.4m-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-F",
      "lighting_per_area": 1.086956522,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. < 2.4m-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-G",
      "lighting_per_area": 1.086956522,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. < 2.4m-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-H",
      "lighting_per_area": 1.086956522,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. < 2.4m-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-I",
      "lighting_per_area": 1.086956522,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. >= 2.4m-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-A",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. >= 2.4m-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-B",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. >= 2.4m-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-C",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. >= 2.4m-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-D",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. >= 2.4m-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-E",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. >= 2.4m-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-F",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. >= 2.4m-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-G",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. >= 2.4m-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-H",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hospital corr. >= 2.4m-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-I",
      "lighting_per_area": 0.891861761,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
      "ventilation_per_area": 0.15,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hotel/Motel - dining",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hotel/Motel - dining",
      "lighting_per_area": 0.817539948,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hotel/Motel - dining",
      "ventilation_per_area": 0.705,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.005455906,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hotel/Motel - lobby",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hotel/Motel - lobby",
      "lighting_per_area": 1.059085842,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hotel/Motel - lobby",
      "ventilation_per_area": 0.285,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001419649,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hotel/Motel - rooms",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hotel/Motel - rooms",
      "lighting_per_area": 1.105536975,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hotel/Motel - rooms",
      "ventilation_per_area": 0.11,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.01140843,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Residential/Accomodation Area",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hway lodging - dining",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hway lodging - dining",
      "lighting_per_area": 0.882571535,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hway lodging - dining",
      "ventilation_per_area": 0.705,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.005455906,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Hway lodging - rooms",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Hway lodging - rooms",
      "lighting_per_area": 0.752508361,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Hway lodging - rooms",
      "ventilation_per_area": 0.11,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.01140843,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Residential/Accomodation Area",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Lab - classrooms",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Lab - classrooms",
      "lighting_per_area": 1.597918989,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Lab - classrooms",
      "ventilation_per_area": 0.43,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004277465,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Lab - research",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Lab - research",
      "lighting_per_area": 2.192493497,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Lab - research",
      "ventilation_per_area": 0.43,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004277465,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Hospital Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Library - cataloging",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Library - cataloging",
      "lighting_per_area": 0.724637681,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Library - cataloging",
      "ventilation_per_area": 0.17,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Library - reading",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Library - reading",
      "lighting_per_area": 0.929022668,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Library - reading",
      "ventilation_per_area": 0.17,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Library - stacks",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Library - stacks",
      "lighting_per_area": 2.12746191,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Library - stacks",
      "ventilation_per_area": 0.17,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Lobby - elevator",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Lobby - elevator",
      "lighting_per_area": 0.641025641,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Lobby - elevator",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Lobby - motion picture",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Lobby - motion picture",
      "lighting_per_area": 0.520252694,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Lobby - motion picture",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Lobby - other",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Lobby - other",
      "lighting_per_area": 0.901151988,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Lobby - other",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Lobby - performance arts",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Lobby - performance arts",
      "lighting_per_area": 1.997398737,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Lobby - performance arts",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-*-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-*-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-*-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-*-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-*-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-*-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-*-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "*"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room-sch-A",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room-sch-B",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room-sch-C",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room-sch-D",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room-sch-E",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room-sch-F",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room-sch-G",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room-sch-H",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Locker room-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Locker room-sch-I",
      "lighting_per_area": 0.910442215,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Locker room",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Lounge/recreation",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Lounge/recreation",
      "lighting_per_area": 0.873281308,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Lounge/recreation",
      "ventilation_per_area": 0.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002853216,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - 7.5 <= bay H <= 15m",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - 7.5 <= bay H <= 15m",
      "lighting_per_area": 1.226309922,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - 7.5 <= bay H <= 15m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425822,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Industrial Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - bay H < 7.5m",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - bay H < 7.5m",
      "lighting_per_area": 1.189149015,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - bay H < 7.5m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425822,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Industrial Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - bay H > 15m",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - bay H > 15m",
      "lighting_per_area": 1.049795615,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - bay H > 15m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425822,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Industrial Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. < 2.4m-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-A",
      "lighting_per_area": 0.510962467,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. < 2.4m-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-B",
      "lighting_per_area": 0.510962467,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. < 2.4m-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-C",
      "lighting_per_area": 0.510962467,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. < 2.4m-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-D",
      "lighting_per_area": 0.510962467,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. < 2.4m-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-E",
      "lighting_per_area": 0.510962467,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. < 2.4m-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-F",
      "lighting_per_area": 0.510962467,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. < 2.4m-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-G",
      "lighting_per_area": 0.510962467,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. < 2.4m-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-H",
      "lighting_per_area": 0.510962467,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. < 2.4m-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-I",
      "lighting_per_area": 0.510962467,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. >= 2.4m-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-A",
      "lighting_per_area": 0.408769974,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. >= 2.4m-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-B",
      "lighting_per_area": 0.408769974,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. >= 2.4m-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-C",
      "lighting_per_area": 0.408769974,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. >= 2.4m-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-D",
      "lighting_per_area": 0.408769974,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. >= 2.4m-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-E",
      "lighting_per_area": 0.408769974,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. >= 2.4m-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-F",
      "lighting_per_area": 0.408769974,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. >= 2.4m-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-G",
      "lighting_per_area": 0.408769974,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. >= 2.4m-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-H",
      "lighting_per_area": 0.408769974,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - corr. >= 2.4m-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-I",
      "lighting_per_area": 0.408769974,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - detailed",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - detailed",
      "lighting_per_area": 1.291341509,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - detailed",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425822,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Industrial Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Mfg - equipment",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Mfg - equipment",
      "lighting_per_area": 1.235600149,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Mfg - equipment",
      "ventilation_per_area": 0.25,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425822,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Industrial Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Museum - exhibition",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Museum - exhibition",
      "lighting_per_area": 1.049795615,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Museum - exhibition",
      "ventilation_per_area": 0.36,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.005706432,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Historical Collections Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Museum - restoration",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Museum - restoration",
      "lighting_per_area": 1.021924935,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Museum - restoration",
      "ventilation_per_area": 0.17,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001191281,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Historical Collections Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Office - enclosed",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Office - enclosed",
      "lighting_per_area": 1.105536975,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Office - enclosed",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Office - enclosed - occsens",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Office - enclosed",
      "lighting_per_area": 0.994983278,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Office - enclosed",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Office - open plan",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Office - open plan",
      "lighting_per_area": 1.021924935,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Office - open plan",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Parking garage space",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Parking garage space",
      "lighting_per_area": 0.185804534,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Parking garage space",
      "ventilation_per_area": 0.5,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.09,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Automotive Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Penitentiary - audience",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Penitentiary - audience",
      "lighting_per_area": 0.427350427,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Penitentiary - audience",
      "ventilation_per_area": 0.41,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002839298,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Penitentiary - classroom",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Penitentiary - classroom",
      "lighting_per_area": 1.337792642,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Penitentiary - classroom",
      "ventilation_per_area": 0.548,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 12.39,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.464511334,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004120874,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Penitentiary - dining",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Penitentiary - dining",
      "lighting_per_area": 1.068376068,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Penitentiary - dining",
      "ventilation_per_area": 0.705,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.005692514,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Post office sorting",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Post office sorting",
      "lighting_per_area": 0.938312895,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Post office sorting",
      "ventilation_per_area": 0.173,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002138732,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Religious - audience",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Religious - audience",
      "lighting_per_area": 1.690821256,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Religious - audience",
      "ventilation_per_area": 0.66,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001419649,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Religious - fellowship hall",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Religious - fellowship hall",
      "lighting_per_area": 0.641025641,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Religious - fellowship hall",
      "ventilation_per_area": 0.66,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004286783,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Religious - pulpit/choir",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Religious - pulpit/choir",
      "lighting_per_area": 1.690821256,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Religious - pulpit/choir",
      "ventilation_per_area": 0.66,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001419649,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Retail - dressing/fitting",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Retail - dressing/fitting",
      "lighting_per_area": 0.873281308,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Retail - dressing/fitting",
      "ventilation_per_area": 0.233,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000631634,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Retail - mall concourse",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Retail - mall concourse",
      "lighting_per_area": 1.096246748,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Retail - mall concourse",
      "ventilation_per_area": 0.36,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000710589,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Retail - sales",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Retail - sales",
      "lighting_per_area": 1.681531029,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Retail - sales",
      "ventilation_per_area": 0.233,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000631634,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Sales area",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Sales area",
      "lighting_per_area": 1.681531029,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Sales area",
      "ventilation_per_area": 0.233,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000631634,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Sports arena - audience",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Sports arena - audience",
      "lighting_per_area": 0.427350427,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Sports arena - audience",
      "ventilation_per_area": 1.185,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002839298,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Sports arena - court c1",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Sports arena - court c1",
      "lighting_per_area": 3.010033445,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Sports arena - court c1",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1393534,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00854573,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Sports arena - court c2",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Sports arena - court c2",
      "lighting_per_area": 1.923076923,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Sports arena - court c2",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1393534,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00854573,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Sports arena - court c3",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Sports arena - court c3",
      "lighting_per_area": 1.198439242,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Sports arena - court c3",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1393534,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00854573,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Sports arena - court c4",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Sports arena - court c4",
      "lighting_per_area": 0.724637681,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Sports arena - court c4",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1393534,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00854573,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Sports arena - ring",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Sports arena - ring",
      "lighting_per_area": 2.675585284,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Sports arena - ring",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 18.58,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1393534,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00854573,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Stairway-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Stairway-sch-A",
      "lighting_per_area": 0.687476774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Stairway",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Stairway-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Stairway-sch-B",
      "lighting_per_area": 0.687476774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Stairway",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Stairway-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Stairway-sch-C",
      "lighting_per_area": 0.687476774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Stairway",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Stairway-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Stairway-sch-D",
      "lighting_per_area": 0.687476774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Stairway",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Stairway-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Stairway-sch-E",
      "lighting_per_area": 0.687476774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Stairway",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Stairway-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Stairway-sch-F",
      "lighting_per_area": 0.687476774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Stairway",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Stairway-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Stairway-sch-G",
      "lighting_per_area": 0.687476774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Stairway",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Stairway-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Stairway-sch-H",
      "lighting_per_area": 0.687476774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Stairway",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Stairway-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Stairway-sch-I",
      "lighting_per_area": 0.687476774,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Stairway",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.46,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Storage area",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Storage area",
      "lighting_per_area": 0.631735414,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Storage area",
      "ventilation_per_area": 0.07,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00142675,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Storage area - occsens",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Storage area",
      "lighting_per_area": 0.568561873,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Storage area",
      "ventilation_per_area": 0.07,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00142675,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Storage area - refrigerated",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Storage area",
      "lighting_per_area": 0.631735414,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Storage area",
      "ventilation_per_area": 0.07,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00142675,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Storage area - refrigerated - occsens",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Storage area",
      "lighting_per_area": 0.568561873,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Storage area",
      "ventilation_per_area": 0.07,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00142675,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Transp. baggage",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Transp. baggage",
      "lighting_per_area": 0.761798588,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Transp. baggage",
      "ventilation_per_area": 0.173,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001546575,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Transp. concourse",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Transp. concourse",
      "lighting_per_area": 0.362318841,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Transp. concourse",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.65,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.003089824,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Transp. counter",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Transp. counter",
      "lighting_per_area": 1.077666295,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Transp. counter",
      "ventilation_per_area": 0.173,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.232255667,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.003089824,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Transp. seating",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Transp. seating",
      "lighting_per_area": 0.538833148,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Transp. seating",
      "ventilation_per_area": 0.81,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001546575,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Warehouse - fine",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Warehouse - fine",
      "lighting_per_area": 0.947603122,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Warehouse - fine",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.86,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00061863,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Warehouse - fine - refrigerated",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Warehouse - fine",
      "lighting_per_area": 0.947603122,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Warehouse - fine",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.86,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00061863,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Warehouse - med/blk",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Warehouse - med/blk",
      "lighting_per_area": 0.594574508,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Warehouse - med/blk",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000309315,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Warehouse - med/blk - refrigerated",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Warehouse - med/blk",
      "lighting_per_area": 0.594574508,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Warehouse - med/blk",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000309315,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Warehouse - med/blk2",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Warehouse - med/blk2",
      "lighting_per_area": 0.947603122,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Warehouse - med/blk2",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000309315,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Warehouse - med/blk2 - refrigerated",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Warehouse - med/blk2",
      "lighting_per_area": 0.947603122,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Warehouse - med/blk2",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.93,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.000309315,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Washroom-sch-A",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Washroom-sch-A",
      "lighting_per_area": 0.975473802,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Washroom",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Washroom-sch-B",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Washroom-sch-B",
      "lighting_per_area": 0.975473802,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Washroom",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Washroom-sch-C",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Washroom-sch-C",
      "lighting_per_area": 0.975473802,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-C-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Washroom",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-C-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-C-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-C-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-C-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "C"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Washroom-sch-D",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Washroom-sch-D",
      "lighting_per_area": 0.975473802,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Washroom",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Washroom-sch-E",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Washroom-sch-E",
      "lighting_per_area": 0.975473802,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-E-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Washroom",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-E-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-E-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-E-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-E-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "E"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Washroom-sch-F",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Washroom-sch-F",
      "lighting_per_area": 0.975473802,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-F-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Washroom",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-F-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-F-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-F-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-F-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "F"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Washroom-sch-G",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Washroom-sch-G",
      "lighting_per_area": 0.975473802,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-G-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Washroom",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-G-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-G-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-G-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-G-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "G"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Washroom-sch-H",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Washroom-sch-H",
      "lighting_per_area": 0.975473802,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Washroom",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Washroom-sch-I",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Washroom-sch-I",
      "lighting_per_area": 0.975473802,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-I-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Washroom",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-I-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-I-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-I-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-I-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Wildcard",
      "necb_schedule_type": "I"
    },
    {
      "template": "NECB 2011",
      "building_type": "Space Function",
      "space_type": "Workshop space",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "Workshop space",
      "lighting_per_area": 1.588628763,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Space Function",
      "ventilation_secondary_space_type": "Workshop space",
      "ventilation_per_area": 0.38,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425822,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Industrial Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Sports arena",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Sports arena",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.780379041,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-B-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Sports arena",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.13,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 9.29,
      "occupancy_schedule": "NECB-B-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-B-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.004274,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-B-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-B-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "B"
    },
    {
      "template": "NECB 2011",
      "building_type": "Town hall",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Town hall",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.919732441,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-D-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Town hall",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.079,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.72,
      "occupancy_schedule": "NECB-D-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.696767001,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-D-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.00171,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-D-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-D-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Assembly Area",
      "necb_schedule_type": "D"
    },
    {
      "template": "NECB 2011",
      "building_type": "Transportation",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Transportation",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.771088815,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-H-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Transportation",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.106,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.19,
      "occupancy_schedule": "NECB-H-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-H-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.002058,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-H-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-H-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "General Area",
      "necb_schedule_type": "H"
    },
    {
      "template": "NECB 2011",
      "building_type": "Warehouse",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Warehouse",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.061,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.06,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 9.5e-05,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Warehouse - refrigerated",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 0.659606094,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Warehouse",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.061,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.06,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.092902267,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 9.5e-05,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2011",
      "building_type": "Workshop",
      "space_type": "WholeBuilding",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2011",
      "lighting_primary_space_type": "Workshop",
      "lighting_secondary_space_type": "WholeBuilding",
      "lighting_per_area": 1.198439242,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.5,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "NECB-A-Lighting",
      "ventilation_standard": "NECB 2011",
      "ventilation_primary_space_type": "Workshop",
      "ventilation_secondary_space_type": "WholeBuilding",
      "ventilation_per_area": 0.211,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.1,
      "occupancy_schedule": "NECB-A-Occupancy",
      "occupancy_activity_schedule": "NECB-Activity",
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929022668,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "NECB-A-Electric-Equipment",
      "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
      "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.001425,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": "NECB-A-Service Water Heating",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "NECB-A-FAN",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "Industrial Area",
      "necb_schedule_type": "A"
    },
    {
      "template": "NECB 2012",
      "building_type": "Space Function",
      "space_type": "Return Plenum",
      "rgb": "255_255_255",
      "lighting_standard": "NECB 2012",
      "lighting_primary_space_type": "Space Function",
      "lighting_secondary_space_type": "- undefined -",
      "lighting_per_area": 0.0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.049225,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": 0.0,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": 0.0,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": "- undefined -",
      "necb_schedule_type": "- undefined -"
    },
    {
      "template": "OEESC 2014",
      "building_type": "FullServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "FullServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_DINING_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Restaurant dining rooms",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.032,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "FullServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantSitDown BLDG_LIGHT_KITCHEN_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantSitDown BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantSitDown ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantSitDown INFIL_HALF_ON_SCH",
      "gas_equipment_per_area": 205.81,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantSitDown Rest_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 37.53,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "RestaurantSitDown BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantSitDown HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantSitDown CLGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1501.0,
      "service_water_heating_peak_flow_per_area": 0.08860759494,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantSitDown BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantSitDown Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "RestaurantSitDown Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.94,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "ER_Exam",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "ER_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.85,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR1_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "ER_Trauma",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 0.192,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "ER_Triage",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 0.192,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "ER Waiting Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 300.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "ICU_NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.85,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Critical and Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "ICU_Open",
      "rgb": "78_167_222",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 0.74,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Critical and Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "ICU_PatRm",
      "rgb": "78_167_222",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.59,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Critical and Intensive Care",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": 51.16,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 7.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 150.0,
      "service_water_heating_area": 10000.0,
      "service_water_heating_peak_flow_per_area": 0.015,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 924.6539122990511,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "Hospital Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "Hospital Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "Lab",
      "rgb": "204_120_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Laboratory",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.4,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Science laboratories",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 2850.0,
      "service_water_heating_peak_flow_per_area": 0.000701754386,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "Lobby",
      "rgb": "31_162_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "NurseStn",
      "rgb": "31_162_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.85,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_NURSEFLR234_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.333,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 0.192,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_EXTD_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Surgery and Critical Care",
      "ventilation_secondary_space_type": "Operating/Surgical Cystoscopic Rooms",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 3,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.92,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_EXTD_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 600.0,
      "service_water_heating_peak_flow_per_area": 0.003333333333,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 6.99,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "PatCorridor",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.94,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "PatRoom",
      "rgb": "78_167_222",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.59,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "AIA 2001",
      "ventilation_primary_space_type": "Nursing",
      "ventilation_secondary_space_type": "Patient Room",
      "ventilation_per_area": "",
      "ventilation_per_person": "",
      "ventilation_air_changes": 2,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_EXTD_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 280.0,
      "service_water_heating_peak_flow_per_area": 0.003571428571,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "PhysTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5280.0,
      "service_water_heating_peak_flow_per_area": 0.0001893939394,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Hospital",
      "space_type": "Radiology",
      "rgb": "136_78_222",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 0.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "Hospital BLDG_LIGHT_RADIOLOGY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Medical procedure",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "Hospital BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Hospital ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Hospital INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Hospital BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "Hospital HTGSETP_SCH",
      "cooling_setpoint_schedule": "Hospital CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 1.0,
      "service_water_heating_area": 5250.0,
      "service_water_heating_peak_flow_per_area": 0.0001904761905,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "Hospital BLDG_SWH_EXTD_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Banquet",
      "rgb": "230_196_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Multipurpose assembly",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0254576,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 6.301,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 1.0,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 0.0,
      "exhaust_fan_maximum_flow_rate": 2000.0,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Basement",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_OFFICE_BSMT_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Multipurpose assembly",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH_2010",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.41,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_CORRIDOR_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0192416,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "GuestRoom",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_GUESTROOM_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.57,
      "occupancy_schedule": "HotelLarge GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.627,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge GuestRoom_Eqp_Sch_Adva",
      "heating_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelLarge Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 1.25,
      "service_water_heating_area": 420.0,
      "service_water_heating_peak_flow_per_area": 0.002976190476,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge GuestRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": "\n",
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0513,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": 767.0,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "HotelLarge Kitchen_Gas_Equip_SCH",
      "electric_equipment_per_area": 47.2,
      "electric_equipment_fraction_latent": 0.2,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.1,
      "electric_equipment_schedule": "HotelLarge Kitchen_Elec_Equip_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 1112.0,
      "service_water_heating_peak_flow_per_area": 0.1196043165,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.385,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 4000.0,
      "exhaust_schedule": "HotelLarge Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "HotelLarge Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.52,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Coinoperated laundries",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": 170.0,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.5,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 5.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 156.6,
      "service_water_heating_area": 840.0,
      "service_water_heating_peak_flow_per_area": 0.1864285714,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelLarge LaundryRoom_SWH_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": 0.385,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": 125.0,
      "exhaust_fan_maximum_flow_rate": 500.0,
      "exhaust_schedule": "HotelLarge Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 1.1,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "LargeHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelLarge BLDG_LIGHT_STORAGE_SCH_2010",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "HotelLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelLarge INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.25,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelLarge BASEMENT_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelLarge HTGSETP_SCH",
      "cooling_setpoint_schedule": "HotelLarge CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "MidriseApartment",
      "space_type": "Apartment",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2004",
      "lighting_primary_space_type": "MidriseApartment",
      "lighting_secondary_space_type": "Apartment",
      "lighting_per_area": 0.36,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.09,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_APT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Apartment",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": 0.35,
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.63,
      "occupancy_schedule": "ApartmentMidRise OCC_APT_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_APT_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_APT_SCH",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": 3.48,
      "service_water_heating_area": 950.0,
      "service_water_heating_peak_flow_per_area": 0.003663157895,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "ApartmentMidRise APT_DHW_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "MidriseApartment",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.41,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_COR_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "ApartmentMidRise All Off",
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_COR_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise BLDG_ELEVATORS",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_APT_SCH",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_APT_SCH",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "MidriseApartment",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": 1.11,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.0,
      "lighting_fraction_visible": 0.0,
      "lighting_schedule": "ApartmentMidRise LTG_OFF_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Living rooms",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.11,
      "occupancy_schedule": "ApartmentMidRise OCC_OFF_SCH",
      "occupancy_activity_schedule": "ApartmentMidRise Activity Schedule",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "ApartmentMidRise INF_OFF_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.6196632768,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "ApartmentMidRise EQP_OFF_SCH_2010_2013",
      "heating_setpoint_schedule": "ApartmentMidRise HTGSETP_OFF_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "ApartmentMidRise CLGSETP_OFF_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "BreakRoom",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 4.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "ClosedOffice",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.75,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.64,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.41,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.16,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.27,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Telephone/data entry",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.56,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07000000000000005,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "OpenOffice",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Open Plan",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.93,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.25,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.71,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "PrintRoom",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.79,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.07,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Stairway",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.49,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "Vending",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.41,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.4,
      "lighting_fraction_radiant": 0.4,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.85,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "WholeBuilding - Lg Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeLarge BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeLarge BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeLarge ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.74973447,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeLarge BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeLarge HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeLarge CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 27.7,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0005165212203,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeLarge BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "WholeBuilding - Md Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeMedium BLDG_LIGHT_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OfficeMedium BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeMedium ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0595,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeMedium INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeMedium BLDG_EQUIP_SCH_2013",
      "heating_setpoint_schedule": "OfficeMedium HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeMedium CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 27.7,
      "service_water_heating_area": 53628.0,
      "service_water_heating_peak_flow_per_area": 0.0005165212203,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeMedium BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Office",
      "space_type": "WholeBuilding - Sm Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Office",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OfficeSmall BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Whole Building",
      "ventilation_per_area": 0.085,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.6,
      "occupancy_schedule": "OfficeSmall BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OfficeSmall ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OfficeSmall INFIL_QUARTER_ON_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.63,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OfficeSmall BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "OfficeSmall HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "OfficeSmall CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 3.0,
      "service_water_heating_area": 5502.0,
      "service_water_heating_peak_flow_per_area": 0.0005452562704,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OfficeSmall BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Anesthesia",
      "rgb": "204_120_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Treatment / Examination",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.01851851852,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.3333346236599153,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 54.520672421626536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "BioHazard",
      "rgb": "204_120_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Cafe",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 99.89,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "CleanWork",
      "rgb": "204_120_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Utility / Workroom",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Conference",
      "rgb": "230_196_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 49.95,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "DressingRoom",
      "rgb": "136_78_222",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 5.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "ElevatorPumpRoom",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.1,
      "electric_equipment_fraction_lost": 0.9,
      "electric_equipment_schedule": "OutPatientHealthCare ELEV_LIGHT_FAN_SCH_ADD_DF",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Exam",
      "rgb": "136_78_222",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Special Procedure Room, Diagnostic",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Hall",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "For Hospital",
      "lighting_per_area": 0.94,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "IT_Room",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Telephone/data entry",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Janitor",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH_20102013",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "LockerRoom",
      "rgb": "169_169_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Healthcare Facility",
      "lighting_per_area": 0.71,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Lounge",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "For Healthcare Facility",
      "lighting_per_area": 0.71,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.01,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "MRI",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 0.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 440.0,
      "service_water_heating_peak_flow_per_area": 0.004545454545,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 166.5909435105255,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "MRI_Control",
      "rgb": "136_78_222",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 0.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 168.0,
      "service_water_heating_peak_flow_per_area": 0.0119047619,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": 1.0000009677449364,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 63.6074511585643,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "MedGas",
      "rgb": "204_120_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "NurseStation",
      "rgb": "31_162_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Nurse Station",
      "lighting_per_area": 0.85,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "OR",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Operating Room",
      "lighting_per_area": 0.192,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Operating rooms outpatient",
      "ventilation_per_area": 0.5,
      "ventilation_per_person": 30,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": 23.87,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.0,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH",
      "electric_equipment_per_area": 4.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare OR_HTGSETP_SCH",
      "cooling_setpoint_schedule": "OutPatientHealthCare OR_CLGSETP_SCH",
      "service_water_heating_peak_flow_rate": 12.0,
      "service_water_heating_area": 472.0,
      "service_water_heating_peak_flow_per_area": 0.02542372881,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_OFFICE_SCH_20102013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "PACU",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Recovery",
      "lighting_per_area": 0.74,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 108.0,
      "service_water_heating_peak_flow_per_area": 0.01851851852,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "PhysicalTherapy",
      "rgb": "154_230_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Physical Therapy",
      "lighting_per_area": 0.8,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Physical therapy",
      "ventilation_per_area": "",
      "ventilation_per_person": 15,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.5,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 946.0,
      "service_water_heating_peak_flow_per_area": 0.002114164905,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "PreOp",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Patient Room",
      "lighting_per_area": 0.59,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "PACU/Pre-Op Outpatient",
      "ventilation_per_area": 0.533,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 263.5,
      "service_water_heating_peak_flow_per_area": 0.007590132827,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "ProcedureRoom",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Hospitals, Nursing and Convalescent Homes",
      "ventilation_secondary_space_type": "Procedure Room Outpatient",
      "ventilation_per_area": 0.8,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 3.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 285.0,
      "service_water_heating_peak_flow_per_area": 0.00701754386,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Reception",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Main entry lobbies",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 29.97,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Soil Work",
      "rgb": "204_120_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Exam/Treatment",
      "lighting_per_area": 1.26,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "Clean Linen Storage",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748944,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 79.50931394820536,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Stairway",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.49,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Toilet",
      "rgb": "169_169_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-1999",
      "ventilation_primary_space_type": "Public Spaces",
      "ventilation_secondary_space_type": "Public restrooms",
      "ventilation_per_area": 0,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.6666682795748942,
      "exhaust_fan_efficiency": 0.31,
      "exhaust_fan_power": 34.075420263516584,
      "exhaust_fan_pressure_rise": 1.0,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "OutPatientHealthCare Hours_of_operation",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Undeveloped",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2004",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.7,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Outpatient",
      "space_type": "Xray",
      "rgb": "169_31_159",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Healthcare Facility",
      "lighting_secondary_space_type": "Radiology/Imaging",
      "lighting_per_area": 0.35,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "OutPatientHealthCare BLDG_LIGHT_EXAM_SCH",
      "ventilation_standard": "GGHC v2.2",
      "ventilation_primary_space_type": "Health Care",
      "ventilation_secondary_space_type": "X-ray, Diagnostic and Treatment",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 20.02,
      "occupancy_schedule": "OutPatientHealthCare BLDG_OCC_SCH",
      "occupancy_activity_schedule": "OutPatientHealthCare ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "OutPatientHealthCare INFIL_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "OutPatientHealthCare BLDG_EQUIP_SCH_BASE",
      "heating_setpoint_schedule": "OutPatientHealthCare HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "OutPatientHealthCare CLGSETP_SCH_YES_OPTIMUM",
      "service_water_heating_peak_flow_rate": 2.0,
      "service_water_heating_area": 900.0,
      "service_water_heating_peak_flow_per_area": 0.002222222222,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "OutPatientHealthCare BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.36,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.23,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (ages 5-8)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 25.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.41,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Gymnasium/Fitness Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Gym, stadium (play area)",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 13.93,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 453.7,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolPrimary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 17.7,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolPrimary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 100.0,
      "service_water_heating_area": 1808.0,
      "service_water_heating_peak_flow_per_area": 0.05530973451,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 572.9644137011418,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolPrimary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolPrimary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Media center",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.39,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "PrimarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolPrimary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolPrimary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolPrimary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolPrimary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolPrimary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolPrimary HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolPrimary CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 56.5,
      "service_water_heating_area": 2045.0,
      "service_water_heating_peak_flow_per_area": 0.02762836186,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolPrimary BLDG_SWH_SCH",
      "exhaust_per_area": 0.293378304967726,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 104.17534794566214,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Attic",
      "rgb": "120_149_230",
      "lighting_standard": "ASHRAE 189.1-2009",
      "lighting_primary_space_type": "Attics",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": null,
      "lighting_fraction_radiant": null,
      "lighting_fraction_visible": null,
      "lighting_schedule": null,
      "ventilation_standard": null,
      "ventilation_primary_space_type": null,
      "ventilation_secondary_space_type": null,
      "ventilation_per_area": null,
      "ventilation_per_person": null,
      "ventilation_air_changes": null,
      "minimum_total_air_changes": null,
      "occupancy_per_area": null,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": null,
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": null,
      "electric_equipment_fraction_latent": null,
      "electric_equipment_fraction_radiant": null,
      "electric_equipment_fraction_lost": null,
      "electric_equipment_schedule": null,
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Dining",
      "rgb": "31_169_34",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "For Family Dining",
      "lighting_per_area": 0.89,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_DINING_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 70.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 10.85,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "QuickServiceRestaurant",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RestaurantFastFood BLDG_LIGHT_KITCHEN_SCH_2010_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "RestaurantFastFood BLDG_OCC_SCH",
      "occupancy_activity_schedule": "RestaurantFastFood ACTIVITY_SCH",
      "infiltration_per_exterior_area": null,
      "infiltration_per_exterior_wall_area": 0.112,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RestaurantFastFood INFIL_SCH_PNNL",
      "gas_equipment_per_area": 250.86,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "RestaurantFastFood FF_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 25.166,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.3,
      "electric_equipment_schedule": "RestaurantFastFood BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RestaurantFastFood HTGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RestaurantFastFood CLGSETP_KITCHEN_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 40.0,
      "service_water_heating_area": 1250.0,
      "service_water_heating_peak_flow_per_area": 0.032,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RestaurantFastFood BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 575.7279076578998,
      "exhaust_fan_pressure_rise": 0.502411575562701,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "RestaurantFastFood Hours_of_operation",
      "balanced_exhaust_fraction_schedule": "RestaurantFastFood Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule_2004",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Retail",
      "space_type": "Back_Space",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_BACK_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Retail",
      "space_type": "Entry",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_ENTRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone FRONT_ENTRY_COOLING",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Retail",
      "space_type": "Point_of_Sale",
      "rgb": "171_222_78",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_FRONT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Retail",
      "space_type": "Retail",
      "rgb": "171_222_78",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStandalone BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.0,
      "occupancy_schedule": "RetailStandalone BLDG_OCC_SCH_2010",
      "occupancy_activity_schedule": "RetailStandalone ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStandalone INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.3,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStandalone BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStandalone HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStandalone CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Auditorium",
      "rgb": "230_196_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Audience/Seating Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.79,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Public Assembly Spaces",
      "ventilation_secondary_space_type": "Auditorium seating area",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 150.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Auditorium",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Cafeteria",
      "rgb": "31_169_34",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Dining Area",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.65,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 100.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Cafeteria",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 7.15,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Classroom",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Classroom/Lecture/Training",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.23,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CLASSROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Classrooms (age 9 plus)",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 35.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.929,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.41,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_CORRIDOR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Gym",
      "rgb": "154_230_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Gymnasium/Fitness Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_GYM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Gym, stadium (play area)",
      "ventilation_per_area": 0.3,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Gym",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.46,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 159.5,
      "service_water_heating_area": 21269.0,
      "service_water_heating_peak_flow_per_area": 0.007499177206,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Kitchen",
      "rgb": "78_222_133",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Food Preparation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.99,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Food and Beverage Service",
      "ventilation_secondary_space_type": "Cafeteria/fast food dining",
      "ventilation_per_area": 0.18,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 15.23,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": 532.1,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SchoolSecondary KITCHEN_GAS_EQUIP_SCH",
      "electric_equipment_per_area": 20.65,
      "electric_equipment_fraction_latent": 0.25,
      "electric_equipment_fraction_radiant": 0.3,
      "electric_equipment_fraction_lost": 0.2,
      "electric_equipment_schedule": "SchoolSecondary KITCHEN_ELEC_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_PSZ_AC",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": 133.0,
      "service_water_heating_area": 2325.0,
      "service_water_heating_peak_flow_per_area": 0.05720430108,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.7,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 694.5023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SchoolSecondary Kitchen_Exhaust_SCH",
      "balanced_exhaust_fraction_schedule": "SchoolSecondary Kitchen Exhaust Fan Balanced Exhaust Fraction Schedule",
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Library",
      "rgb": "230_196_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Library",
      "lighting_per_area": 1.17,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LIBRARY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Educational Facilities",
      "ventilation_secondary_space_type": "Media center",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": 10,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.93,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Lobby",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lobby",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.9,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_LOBBYFLR1_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH_Offices",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_YES_OPTIMUM",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_NO_SETBACK",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SecondarySchool",
      "space_type": "Restroom",
      "rgb": "169_169_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SchoolSecondary BLDG_LIGHT_BATH_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "SchoolSecondary BLDG_OCC_SCH",
      "occupancy_activity_schedule": "SchoolSecondary ACTIVITY_SCH",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SchoolSecondary INFIL_SCH_PNNL",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.37,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SchoolSecondary BLDG_EQUIP_SCH",
      "heating_setpoint_schedule": "SchoolSecondary HTGSETP_SCH_Setback",
      "cooling_setpoint_schedule": "SchoolSecondary CLGSETP_SCH_Setback",
      "service_water_heating_peak_flow_rate": 52.2,
      "service_water_heating_area": 2260.0,
      "service_water_heating_peak_flow_per_area": 0.02309734513,
      "service_water_heating_target_temperature": 43.3,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SchoolSecondary BLDG_SWH_SCH",
      "exhaust_per_area": 0.2812153843741127,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 110.36763444376396,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "Corridor",
      "rgb": "169_31_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Corridor/Transition",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.41,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_CORRIDOR_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "Elec/MechRoom",
      "rgb": "41_31_175",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": null,
      "occupancy_activity_schedule": null,
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 198.2,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall BLDG_ELEVATORS",
      "heating_setpoint_schedule": null,
      "cooling_setpoint_schedule": null,
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "Exercise",
      "rgb": "154_230_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Gymnasium/Fitness Center",
      "lighting_secondary_space_type": "Exercise Area",
      "lighting_per_area": 0.72,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EXERCENTER_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Sports and Entertainment",
      "ventilation_secondary_space_type": "Health club/weight rooms",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 20,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 19.94,
      "occupancy_schedule": "HotelSmall ExerciseCenter_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.73,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall ExerciseCenter_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "GuestLounge",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_FRONTLOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 30.0,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.42,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom123Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Occ",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_GUESTROOM_SCH_2013",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall GuestRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.028,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall GuestRoom_Eqp_Sch_Base",
      "heating_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall Adva_OccGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall GuestRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "GuestRoom4Vac",
      "rgb": "78_167_222",
      "lighting_standard": "ASHRAE 90.1-2013",
      "lighting_primary_space_type": "Guest Room",
      "lighting_secondary_space_type": "For Hotel",
      "lighting_per_area": 0.91,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall AlwaysOff",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Bedroom/living Room",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 4.27,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.028,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall GuestRoom_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.1,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall VacGuestRoom_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall VacGuestRoom_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 2.22,
      "service_water_heating_area": 351.0,
      "service_water_heating_peak_flow_per_area": 0.006324786325,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall AlwaysOff",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "Yes",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "Laundry",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Hospital",
      "lighting_secondary_space_type": "Laundry-Washing",
      "lighting_per_area": 0.52,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_LAUNDRY_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Coinoperated laundries",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 10.0,
      "occupancy_schedule": "HotelSmall LaundryRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": 129.9,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.0,
      "gas_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Gas_Sch",
      "electric_equipment_per_area": 2.57,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall LaundryRoom_Eqp_Elec_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": 123.0,
      "service_water_heating_area": 1053.0,
      "service_water_heating_peak_flow_per_area": 0.1168091168,
      "service_water_heating_target_temperature": 82.2,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "HotelSmall LaundryRoom_SHW_Sch",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "Mechanical",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Electrical/Mechanical",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MECHROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": 0.0,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.5,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.2,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "Meeting",
      "rgb": "230_196_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Conference/Meeting/Multipurpose",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.11,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_MEETINGROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Conference/meeting",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 50.0,
      "occupancy_schedule": "HotelSmall MeetingRoom_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.574,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall MeetingRoom_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 7.14,
      "occupancy_schedule": "HotelSmall Office_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 1.28,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall OFF_EQUIP_SCH",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "PublicRestroom",
      "rgb": "169_169_31",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Restrooms",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_RESTROOM_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 2.85,
      "occupancy_schedule": "HotelSmall Lobby_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall Lobby_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": 1.139566144206643,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 69.45023196377475,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "StaffLounge",
      "rgb": "31_169_34",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Lounge/Recreation",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.73,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_EMPLOYEELOUNGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Hotels, Motels, Resorts, Dormitories",
      "ventilation_secondary_space_type": "Lobbies/prefunction",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 51.28,
      "occupancy_schedule": "HotelSmall EmployeeLounge_Occ_Sch",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "HotelSmall CommonArea_Infil_Sch",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 2.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall EmployeeLounge_Eqp_Sch",
      "heating_setpoint_schedule": "HotelSmall CommonArea_HtgSP_Sch",
      "cooling_setpoint_schedule": "HotelSmall CommonArea_ClgSP_Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "Stair",
      "rgb": "230_157_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Stairway",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.49,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STAIR_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Corridors",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SmallHotel",
      "space_type": "Storage",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "HotelSmall BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "HotelSmall AlwaysOff",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.112,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Always On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "HotelSmall AlwaysOff",
      "heating_setpoint_schedule": "HotelSmall SemiHeated_HtgSP_Sch",
      "cooling_setpoint_schedule": "SmallHotel UnitHeater ClgSP Sch",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": "No",
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 1",
      "rgb": "171_222_78",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.32,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.38346,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type1_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type1_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0495376,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type1_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type1_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type1_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type1_CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type1_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 2",
      "rgb": "171_222_78",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.32,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.18346,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type2_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type2_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0349328,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type2_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type2_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type2_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type2_CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type2_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "StripMall",
      "space_type": "Strip mall - type 3",
      "rgb": "171_222_78",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Whole Building",
      "lighting_secondary_space_type": "Retail",
      "lighting_per_area": 1.32,
      "lighting_per_person": null,
      "additional_lighting_per_area": 0.0336,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "RetailStripmall Type3_LIGHT_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "General Sales combined by area",
      "ventilation_per_area": 0.2325,
      "ventilation_per_person": 0,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "RetailStripmall Type3_OCC_SCH",
      "occupancy_activity_schedule": "HotelSmall Activity_Sch",
      "infiltration_per_exterior_area": 0.0349328,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "RetailStripmall Type3_Infil_SCH",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.4,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "RetailStripmall Type3_EQUIP_SCH",
      "heating_setpoint_schedule": "RetailStripmall Type3_HTGSETP_SCH_NO_OPTIMUM",
      "cooling_setpoint_schedule": "RetailStripmall Type3_CLGSETP_SCH_NO_OPTIMUM",
      "service_water_heating_peak_flow_rate": 1.8,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": null,
      "service_water_heating_target_temperature": 60.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "RetailStripmall Type3_SWH_SCH",
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SuperMarket",
      "space_type": "Deli/Bakery",
      "rgb": "31_169_34",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": 6.25,
      "gas_equipment_fraction_latent": 0.1,
      "gas_equipment_fraction_radiant": 0.2,
      "gas_equipment_fraction_lost": 0.7,
      "gas_equipment_schedule": "SuperMarket Gas Equip New",
      "electric_equipment_per_area": 3.6400015672260313,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": 5.0,
      "service_water_heating_area": 2334.5,
      "service_water_heating_peak_flow_per_area": 0.00214178625,
      "service_water_heating_target_temperature": 49.0,
      "service_water_heating_fraction_sensible": 0.2,
      "service_water_heating_fraction_latent": 0.05,
      "service_water_heating_schedule": "SuperMarket SWH",
      "exhaust_per_area": 1.2402518232437685,
      "exhaust_fan_efficiency": 0.338,
      "exhaust_fan_power": 520.8767397283107,
      "exhaust_fan_pressure_rise": 0.5,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": "SuperMarket_Deli_Exhaust",
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SuperMarket",
      "space_type": "DryStorage",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Storage",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.63,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "General",
      "ventilation_secondary_space_type": "Storage rooms",
      "ventilation_per_area": 0.12,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 3.33,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SuperMarket",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.97,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 5.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.5400002325005652,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "SuperMarket",
      "space_type": "Sales/Produce",
      "rgb": "230_196_120",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Retail",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 1.5,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.7,
      "lighting_fraction_visible": 0.2,
      "lighting_schedule": "SuperMarket Bldg Light",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Retail",
      "ventilation_secondary_space_type": "Supermarket",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 7.5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 8.0,
      "occupancy_schedule": "SuperMarket Bldg Occ",
      "occupancy_activity_schedule": "SuperMarket Activity",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "SuperMarket Infil Half On",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.36000015500037674,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "SuperMarket Bldg Equip",
      "heating_setpoint_schedule": "SuperMarket HtgSetp",
      "cooling_setpoint_schedule": "SuperMarket ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Warehouse",
      "space_type": "Bulk",
      "rgb": "41_31_169",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Medium/Bulky Material Storage",
      "lighting_per_area": 0.58,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Miscellaneous Spaces",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse ALWAYS_ON",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.237684638,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Bulk Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse ClgSetp BulkStorage",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Warehouse",
      "space_type": "Fine",
      "rgb": "120_149_230",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Warehouse",
      "lighting_secondary_space_type": "Fine Material Storage",
      "lighting_per_area": 0.95,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.42,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_STORAGE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Miscellaneous Spaces",
      "ventilation_secondary_space_type": "Warehouses",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": "",
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 0.0,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse ALWAYS_ON",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.0,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Bldg Equip",
      "heating_setpoint_schedule": "Warehouse Fine Storage Heating Setpoint Schedule",
      "cooling_setpoint_schedule": "Warehouse Fine Storage Cooling Setpoint Schedule",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    },
    {
      "template": "OEESC 2014",
      "building_type": "Warehouse",
      "space_type": "Office",
      "rgb": "120_230_199",
      "lighting_standard": "OEESC 2014",
      "lighting_primary_space_type": "Office-Enclosed",
      "lighting_secondary_space_type": "General",
      "lighting_per_area": 0.82,
      "lighting_per_person": null,
      "additional_lighting_per_area": null,
      "lighting_fraction_to_return_air": 0.0,
      "lighting_fraction_radiant": 0.37,
      "lighting_fraction_visible": 0.18,
      "lighting_schedule": "Warehouse BLDG_LIGHT_OFFICE_SCH",
      "ventilation_standard": "ASHRAE 62.1-2007",
      "ventilation_primary_space_type": "Office Buildings",
      "ventilation_secondary_space_type": "Office space",
      "ventilation_per_area": 0.06,
      "ventilation_per_person": 5,
      "ventilation_air_changes": "",
      "minimum_total_air_changes": null,
      "occupancy_per_area": 1.96,
      "occupancy_schedule": "Warehouse BLDG_OCC_SCH",
      "occupancy_activity_schedule": "Warehouse Office Activity Schedule",
      "infiltration_per_exterior_area": 0.0446,
      "infiltration_per_exterior_wall_area": null,
      "infiltration_air_changes": null,
      "infiltration_schedule": "Warehouse ALWAYS_ON",
      "gas_equipment_per_area": null,
      "gas_equipment_fraction_latent": null,
      "gas_equipment_fraction_radiant": null,
      "gas_equipment_fraction_lost": null,
      "gas_equipment_schedule": null,
      "electric_equipment_per_area": 0.75,
      "electric_equipment_fraction_latent": 0.0,
      "electric_equipment_fraction_radiant": 0.5,
      "electric_equipment_fraction_lost": 0.0,
      "electric_equipment_schedule": "Warehouse Office_Plug_SCH",
      "heating_setpoint_schedule": "Warehouse HtgSetp",
      "cooling_setpoint_schedule": "Warehouse ClgSetp",
      "service_water_heating_peak_flow_rate": null,
      "service_water_heating_area": null,
      "service_water_heating_peak_flow_per_area": "",
      "service_water_heating_target_temperature": null,
      "service_water_heating_fraction_sensible": null,
      "service_water_heating_fraction_latent": null,
      "service_water_heating_schedule": null,
      "exhaust_per_area": null,
      "exhaust_fan_efficiency": null,
      "exhaust_fan_power": null,
      "exhaust_fan_pressure_rise": null,
      "exhaust_fan_maximum_flow_rate": null,
      "exhaust_schedule": null,
      "balanced_exhaust_fraction_schedule": null,
      "is_residential": null,
      "necb_hvac_system_selection_type": null,
      "necb_schedule_type": null
    }
  ]
}