# frozen_string_literal: true # ******************************************************************************* # OpenStudio(R), Copyright (c) 2008-2021, Alliance for Sustainable Energy, LLC. # All rights reserved. # Redistribution and use in source and binary forms, with or without # modification, are permitted provided that the following conditions are met: # # (1) Redistributions of source code must retain the above copyright notice, # this list of conditions and the following disclaimer. # # (2) Redistributions in binary form must reproduce the above copyright notice, # this list of conditions and the following disclaimer in the documentation # and/or other materials provided with the distribution. # # (3) Neither the name of the copyright holder nor the names of any contributors # may be used to endorse or promote products derived from this software without # specific prior written permission from the respective party. # # (4) Other than as required in clauses (1) and (2), distributions in any form # of modifications or other derivative works may not use the "OpenStudio" # trademark, "OS", "os", or any other confusingly similar designation without # specific prior written permission from Alliance for Sustainable Energy, LLC. # # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, # THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE # UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF # THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, # EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT # OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, # STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY # OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. # ******************************************************************************* # see the URL below for information on how to write OpenStuido measures # http://openstudio.nrel.gov/openstudio-measure-writing-guide # see the URL below for access to C++ documentation on mondel objects (click on "model" in the main window to view model objects) # http://openstudio.nrel.gov/sites/openstudio.nrel.gov/files/nv_data/cpp_documentation_it/model/html/namespaces.html # start the measure class GLHEProSetupExportLoadsforGroundHeatExchangerSizing < OpenStudio::Measure::ModelMeasure # define the name that a user will see, this method may be deprecated as # the display name in PAT comes from the name field in measure.xml def name return 'GLHEProSetupExportLoadsforGroundHeatExchangerSizing' end # define the arguments that the user will input def arguments(model) args = OpenStudio::Measure::OSArgumentVector.new return args end # define what happens when the measure is run def run(model, runner, user_arguments) super(model, runner, user_arguments) # use the built-in error checking if !runner.validateUserArguments(arguments(model), user_arguments) return false end # Define the reporting frequency reporting_frequency = 'hourly' # Define the variables to report variable_names = [] variable_names << 'District Heating Rate' variable_names << 'District Cooling Rate' # Request each output variable variable_names.each do |variable_name| output_variable = OpenStudio::Model::OutputVariable.new(variable_name, model) output_variable.setReportingFrequency(reporting_frequency) runner.registerInfo("Requested output for '#{output_variable.variableName}' at the #{output_variable.reportingFrequency} timestep.") end # Report the outlet node conditions for each plant loop in the model # Rename the outlet node so that it makes sense in the report outlet_node_variable_names = [] outlet_node_variable_names << 'System Node Temperature' outlet_node_variable_names << 'System Node Setpoint Temperature' outlet_node_variable_names << 'System Node Mass Flow Rate' model.getPlantLoops.each do |plant_loop| outlet_node = plant_loop.supplyOutletNode outlet_node_name = "#{plant_loop.name} Supply Outlet Node" outlet_node.setName(outlet_node_name) outlet_node_variable_names.each do |outlet_node_variable_name| output_variable = OpenStudio::Model::OutputVariable.new(outlet_node_variable_name, model) output_variable.setKeyValue(outlet_node_name) output_variable.setReportingFrequency(reporting_frequency) end end return true end end # this allows the measure to be use by the application GLHEProSetupExportLoadsforGroundHeatExchangerSizing.new.registerWithApplication