  "prototype_inputs": [
    {
      "template": "CBES T24 1978",
      "building_type": "MediumOffice",
      "hvac_system": null,
      "geometry_osm": "CBESMediumOffice.osm",
      "hvac_json": "CBESMediumOffice.json",
      "chw_pumping_type": null,
      "chiller_cooling_type": null,
      "chiller_condenser_type": null,
      "chiller_compressor_type": null,
      "chiller_capacity_guess": null,
      "pszac_cooling_type": "Two Speed DX AC",
      "pszac_heating_type": "Gas",
      "pszac_fan_type": "ConstantVolume",
      "pszac_supplemental_heating_type": null,
      "pszac_operation_schedule": "OfficeHVACAvail",
      "pszac_oa_damper_schedule": "OfficeOACtrl Schedule",
      "pszac_operation_schedule_2": null,
      "pszac_oa_damper_schedule_2": null,
      "pszac_operation_schedule_3": null,
      "pszac_oa_damper_schedule_3": null,
      "occ_sensing_exterior_lighting_power": null,
      "occ_sensing_exterior_lighting_schedule": null,
      "nondimming_exterior_lighting_power": null,
      "nondimming_exterior_lighting_schedule": null,
      "exterior_fuel_equipment1_power": null,
      "exterior_fuel_equipment1_schedule": null,
      "exterior_fuel_equipment2_power": null,
      "exterior_fuel_equipment2_schedule": null,
      "main_water_heater_volume": 100.0,
      "main_water_heater_fuel": "Natural Gas",
      "main_water_heater_capacity": 64851.0,
      "main_service_water_temperature": 135.0,
      "main_service_water_flowrate_schedule": "OfficeServiceHotWater",
      "main_water_heater_space_name": null,
      "main_service_water_peak_flowrate": null,
      "main_off_cycle_parasitic_heat_fraction_to_tank": null,
      "other_off_cycle_parasitic_heat_fraction_to_tank": null,
      "main_water_use_temperature": 140.0,
      "main_service_water_temperature_at_fixture": 110.0,
      "main_service_water_pump_head": 240925.11,
      "main_service_water_pump_motor_efficiency": 0.875,
      "main_service_water_parasitic_fuel_consumption_rate": 700.0,
      "laundry_water_heater_volume": null,
      "laundry_water_heater_fuel": null,
      "laundry_water_heater_capacity": null,
      "laundry_service_water_temperature": null,
      "laundry_service_water_flowrate_schedule": null,
      "laundry_service_water_peak_flowrate": null,
      "laundry_water_use_temperature": null,
      "laundry_service_water_temperature_at_fixture": null,
      "laundry_service_water_pump_head": null,
      "laundry_service_water_pump_motor_efficiency": null,
      "laundry_service_water_parasitic_fuel_consumption_rate": null,
      "booster_water_heater_volume": null,
      "booster_water_heater_fuel": null,
      "booster_water_heater_capacity": null,
      "booster_inlet_water_temperature": null,
      "booster_service_water_flowrate_schedule": null,
      "booster_water_heater_space_name": null,
      "booster_service_water_peak_flowrate": null,
      "booster_water_use_temperature": null,
      "booster_water_temperature": null,
      "booster_service_water_parasitic_fuel_consumption_rate": null,
      "typical_heating_setpoint": "OfficeHtgSetpt",
      "typical_cooling_setpoint": "OfficeClgSetpt",
      "ptac_cooling_type": null,
      "ptac_heating_type": null,
      "ptac_fan_type": null,
      "ptac_operation_schedule": null,
      "ptac_oa_damper_schedule": null,
      "sac_cooling_type": null,
      "sac_heating_type": null,
      "sac_fan_type": null,
      "sac_operation_schedule": null,
      "sac_operation_schedule_meeting": null,
      "sac_oa_damper_schedule": null,
      "unitheater_heating_type": null,
      "unitheater_fan_type": null,
      "unitheater_fan_control_type": null,
      "unitheater_fan_static_pressure": null,
      "unitheater_operation_schedule": null,
      "vav_operation_schedule": "OfficeHVACAvail",
      "vav_oa_damper_schedule": "OfficeOACtrl Schedule",
      "vav_fan_efficiency": 0.568,
      "vav_fan_pressure_rise": 996.36,
      "vav_fan_motor_efficiency": 0.875,
      "doas_fan_maximum_flow_rate": null,
      "doas_oa_damper_schedule": null,
      "doas_economizer_control_type": null,
      "elevator_type": "Hydraulic",
      "number_of_elevators": 2.0,
      "elevator_schedule": "Medium Office BLDG ELEVATORS",
      "elevator_fan_schedule": "OfficeMedium ELEV_LIGHT_FAN_SCH_24_7",
      "nonmetal_framing": null,
      "crac_cooling_type": null,
      "crac_fan_type": null,
      "crac_operation_schedule": null,
      "crac_oa_damper_schedule": null
    },
    {
      "template": "CBES T24 1978",
      "building_type": "RetailStandalone",
      "hvac_system": null,
      "geometry_osm": "CBESRetailStandalone.osm",
      "hvac_json": "CBESRetailStandalone.json",
      "chw_pumping_type": null,
      "chiller_cooling_type": null,
      "chiller_condenser_type": null,
      "chiller_compressor_type": null,
      "chiller_capacity_guess": null,
      "pszac_cooling_type": "Two Speed DX AC",
      "pszac_heating_type": "Gas",
      "pszac_fan_type": "ConstantVolume",
      "pszac_supplemental_heating_type": null,
      "pszac_operation_schedule": "RetailStandalone HVACOperationSchd",
      "pszac_oa_damper_schedule": "RetailOACtrl Schedule",
      "pszac_operation_schedule_2": null,
      "pszac_oa_damper_schedule_2": null,
      "pszac_operation_schedule_3": null,
      "pszac_oa_damper_schedule_3": null,
      "occ_sensing_exterior_lighting_power": null,
      "occ_sensing_exterior_lighting_schedule": null,
      "nondimming_exterior_lighting_power": null,
      "nondimming_exterior_lighting_schedule": null,
      "exterior_fuel_equipment1_power": null,
      "exterior_fuel_equipment1_schedule": null,
      "exterior_fuel_equipment2_power": null,
      "exterior_fuel_equipment2_schedule": null,
      "main_water_heater_volume": 100.0,
      "main_water_heater_fuel": "Natural Gas",
      "main_water_heater_capacity": 83215.0,
      "main_service_water_temperature": 135.0,
      "main_service_water_flowrate_schedule": "RetailServiceHotWater",
      "main_water_heater_space_name": null,
      "main_service_water_peak_flowrate": null,
      "main_off_cycle_parasitic_heat_fraction_to_tank": null,
      "other_off_cycle_parasitic_heat_fraction_to_tank": null,
      "main_water_use_temperature": 140.0,
      "main_service_water_temperature_at_fixture": 110.0,
      "main_service_water_pump_head": 0.001,
      "main_service_water_pump_motor_efficiency": 0.875,
      "main_service_water_parasitic_fuel_consumption_rate": 700.0,
      "laundry_water_heater_volume": null,
      "laundry_water_heater_fuel": null,
      "laundry_water_heater_capacity": null,
      "laundry_service_water_temperature": null,
      "laundry_service_water_flowrate_schedule": null,
      "laundry_service_water_peak_flowrate": null,
      "laundry_water_use_temperature": null,
      "laundry_service_water_temperature_at_fixture": null,
      "laundry_service_water_pump_head": null,
      "laundry_service_water_pump_motor_efficiency": null,
      "laundry_service_water_parasitic_fuel_consumption_rate": null,
      "booster_water_heater_volume": null,
      "booster_water_heater_fuel": null,
      "booster_water_heater_capacity": null,
      "booster_inlet_water_temperature": null,
      "booster_service_water_flowrate_schedule": null,
      "booster_water_heater_space_name": null,
      "booster_service_water_peak_flowrate": null,
      "booster_water_use_temperature": null,
      "booster_water_temperature": null,
      "booster_service_water_parasitic_fuel_consumption_rate": null,
      "typical_heating_setpoint": "RetailHtgSetpt",
      "typical_cooling_setpoint": "RetailClgSetpt",
      "ptac_cooling_type": null,
      "ptac_heating_type": null,
      "ptac_fan_type": null,
      "ptac_operation_schedule": null,
      "ptac_oa_damper_schedule": null,
      "sac_cooling_type": null,
      "sac_heating_type": null,
      "sac_fan_type": null,
      "sac_operation_schedule": null,
      "sac_operation_schedule_meeting": null,
      "sac_oa_damper_schedule": null,
      "unitheater_heating_type": "Gas",
      "unitheater_fan_type": "ConstantVolume",
      "unitheater_fan_control_type": "OnOff",
      "unitheater_fan_static_pressure": 4.4584,
      "unitheater_operation_schedule": "RetailStandalone FrontEntry_FanSched",
      "vav_operation_schedule": "RetailStandalone HVACOperationSchd",
      "vav_oa_damper_schedule": "RetailOACtrl Schedule",
      "vav_fan_efficiency": 0.568,
      "vav_fan_pressure_rise": 996.36,
      "vav_fan_motor_efficiency": 0.875,
      "doas_fan_maximum_flow_rate": null,
      "doas_oa_damper_schedule": null,
      "doas_economizer_control_type": null,
      "elevator_type": null,
      "number_of_elevators": null,
      "elevator_schedule": null,
      "elevator_fan_schedule": null,
      "nonmetal_framing": null,
      "crac_cooling_type": null,
      "crac_fan_type": null,
      "crac_operation_schedule": null,
      "crac_oa_damper_schedule": null
    },
    {
      "template": "CBES T24 1978",
      "building_type": "SmallOffice",
      "hvac_system": null,
      "geometry_osm": "CBESSmallOffice.osm",
      "hvac_json": "CBESSmallOffice.json",
      "chw_pumping_type": null,
      "chiller_cooling_type": null,
      "chiller_condenser_type": null,
      "chiller_compressor_type": null,
      "chiller_capacity_guess": null,
      "pszac_cooling_type": "Single Speed DX AC",
      "pszac_heating_type": "Gas",
      "pszac_fan_type": "ConstantVolume",
      "pszac_supplemental_heating_type": null,
      "pszac_operation_schedule": "OfficeHVACAvail",
      "pszac_oa_damper_schedule": "OfficeOACtrl Schedule",
      "pszac_operation_schedule_2": null,
      "pszac_oa_damper_schedule_2": null,
      "pszac_operation_schedule_3": null,
      "pszac_oa_damper_schedule_3": null,
      "occ_sensing_exterior_lighting_power": null,
      "occ_sensing_exterior_lighting_schedule": null,
      "nondimming_exterior_lighting_power": null,
      "nondimming_exterior_lighting_schedule": null,
      "exterior_fuel_equipment1_power": null,
      "exterior_fuel_equipment1_schedule": null,
      "exterior_fuel_equipment2_power": null,
      "exterior_fuel_equipment2_schedule": null,
      "main_water_heater_volume": 40.0,
      "main_water_heater_fuel": "Natural Gas",
      "main_water_heater_capacity": 6650.0,
      "main_service_water_temperature": 135.0,
      "main_service_water_flowrate_schedule": "OfficeServiceHotWater",
      "main_water_heater_space_name": null,
      "main_service_water_peak_flowrate": null,
      "main_off_cycle_parasitic_heat_fraction_to_tank": null,
      "other_off_cycle_parasitic_heat_fraction_to_tank": null,
      "main_water_use_temperature": 140.0,
      "main_service_water_temperature_at_fixture": 110.0,
      "main_service_water_pump_head": 0.001,
      "main_service_water_pump_motor_efficiency": 0.875,
      "main_service_water_parasitic_fuel_consumption_rate": 700.0,
      "laundry_water_heater_volume": null,
      "laundry_water_heater_fuel": null,
      "laundry_water_heater_capacity": null,
      "laundry_service_water_temperature": null,
      "laundry_service_water_flowrate_schedule": null,
      "laundry_service_water_peak_flowrate": null,
      "laundry_water_use_temperature": null,
      "laundry_service_water_temperature_at_fixture": null,
      "laundry_service_water_pump_head": null,
      "laundry_service_water_pump_motor_efficiency": null,
      "laundry_service_water_parasitic_fuel_consumption_rate": null,
      "booster_water_heater_volume": null,
      "booster_water_heater_fuel": null,
      "booster_water_heater_capacity": null,
      "booster_inlet_water_temperature": null,
      "booster_service_water_flowrate_schedule": null,
      "booster_water_heater_space_name": null,
      "booster_service_water_peak_flowrate": null,
      "booster_water_use_temperature": null,
      "booster_water_temperature": null,
      "booster_service_water_parasitic_fuel_consumption_rate": null,
      "typical_heating_setpoint": "OfficeHtgSetpt",
      "typical_cooling_setpoint": "OfficeClgSetpt",
      "ptac_cooling_type": null,
      "ptac_heating_type": null,
      "ptac_fan_type": null,
      "ptac_operation_schedule": null,
      "ptac_oa_damper_schedule": null,
      "sac_cooling_type": null,
      "sac_heating_type": null,
      "sac_fan_type": null,
      "sac_operation_schedule": null,
      "sac_operation_schedule_meeting": null,
      "sac_oa_damper_schedule": null,
      "unitheater_heating_type": null,
      "unitheater_fan_type": null,
      "unitheater_fan_control_type": null,
      "unitheater_fan_static_pressure": null,
      "unitheater_operation_schedule": null,
      "vav_operation_schedule": null,
      "vav_oa_damper_schedule": null,
      "vav_fan_efficiency": null,
      "vav_fan_pressure_rise": null,
      "vav_fan_motor_efficiency": null,
      "doas_fan_maximum_flow_rate": null,
      "doas_oa_damper_schedule": null,
      "doas_economizer_control_type": null,
      "elevator_type": null,
      "number_of_elevators": null,
      "elevator_schedule": null,
      "elevator_fan_schedule": null,
      "nonmetal_framing": null,
      "crac_cooling_type": null,
      "crac_fan_type": null,
      "crac_operation_schedule": null,
      "crac_oa_damper_schedule": null
    }
  ]
}