3.0
aedg_k_12_swh
081b3ccb-fc4a-48f7-ad50-87c90c20f9f9
9bcc8b96-2012-4fd4-ad4e-21623d84182c
20200401T014104Z
9882CBDB
AedgK12Swh
AedgK12Swh
Measure replaces existing swh equipment (if any) with the swh equipment recommendations of the 50% K-12 AEDG.
Measure is applied to restroom and kitchen space types for both primary and secondary schools, and to gyms for secondary schools. All existing swh systems are deleted. The largest kitchen and gym spaces are selected as representative spaces, to which the corresponding AEDG recommended swh loads are applied. For restrooms, the total SWH load is divided evenly among the restroom spaces in the model. Loads are applied on a per student basis. The user can input number of students manually. Otherwise, the measure will calculate the number of students from the classroom floor area. If there is no classroom floor area, the user wil be required to specify a number of students.
costTotalSwhSystem
Total Cost for Kitchen System ($).
Double
true
false
0
numberOfStudents
Total Number of Students.
Integer
true
false
Service Water Heating.Water Heating