3.0
aedg_small_to_medium_office_fenestration_and_daylighting_controls
4252d6c7-ccd5-4cae-b55e-8d7b1dfcc717
530b1402-2908-4a5c-90b5-f8212508977d
20210429T165036Z
6FAFA9DE
AedgSmallToMediumOfficeFenestrationAndDaylightingControls
AedgSmallToMediumOfficeFenestrationAndDaylightingControls
This measure will remove all existing exterior windows, glass doors, and skylights from your model. They will be replaced with view and daylight windows as recommended by the Small to Medium Office AEDG recommendations. Windows on the south facade will have a exterior shading or light shelf surfaces depending on if they are view or daylight windows. East and west view windows will have internal shading controls. In spaces with daylighting controls daylight sensor will be added. The modeler should inspect where the sensors were placed, the recommended illuminance setpoint, and the fraction of the zones lighting controlled by the sensor.
This measure is intended for use in models created form space types defined in the office building types. Fenestration will be added to all spaces with exterior walls except for spaces not included in the floor area. This should include attic and plenum spaces. Daylighting will only be added to north and south facades. North and south facades can be +/- 30 degrees of north and south. East and west facades will only receive view windows. The daylight sensor's depth in from the wall will typically be the same as the height of the wall that the daylight windows is on. This depth is also what is used to calculate the daylight fraction of the space. In spaces that are non convex, such as an L shaped space, we may not be able to place a sensor, if that happens a warning will be issued.
cost_daylight_glazing
Cost per Area for Proposed Daylighting Window Constructions ($/ft^2).
Double
true
false
0
cost_view_glazing
Cost per Area for Proposed View Window Constructions ($/ft^2).
Double
true
false
0
cost_skylight
Cost per Area for Proposed Skylight Construction ($/ft^2).
Double
true
false
0
cost_shading_surface
Cost per Area for Proposed Exterior Shading Surface Construction ($/ft^2).
Double
true
false
0
cost_light_shelf
Cost per Area for Proposed Light Shelf Construction ($/ft^2).
Double
true
false
0
Envelope.Fenestration
Measure Type
ModelMeasure
string
Uses SketchUp API
false
boolean
BasicOfficeWithOnePlenumFloor.osm
osm
test
00CA6E96
README.md.erb
erb
readmeerb
703C9964
README.md
md
readme
7E1CCC62
AedgSmallToMediumOfficeFenestrationAndDaylightingControls_Test.rb
rb
test
61D49491
LICENSE.md
md
license
A21A3ED2
OpenStudio
2.0.0
2.8.0
measure.rb
rb
script
53BDDDE0
OsLib_AedgMeasures.rb
rb
resource
BA9FA6C6