  "parking": [
    {
      "building_type": "SmallOffice",
      "building_area_per_spot": 250.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "MediumOffice",
      "building_area_per_spot": 250.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "LargeOffice",
      "building_area_per_spot": 620.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "Retail",
      "building_area_per_spot": 285.7,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "StripMall",
      "building_area_per_spot": 215.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "PrimarySchool",
      "building_area_per_spot": null,
      "units_per_spot": null,
      "students_per_spot": 17.0,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "SecondarySchool",
      "building_area_per_spot": null,
      "units_per_spot": null,
      "students_per_spot": 8.0,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "Outpatient",
      "building_area_per_spot": 200.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "Hospital",
      "building_area_per_spot": null,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": 0.83,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "SmallHotel",
      "building_area_per_spot": null,
      "units_per_spot": 1.0,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "LargeHotel",
      "building_area_per_spot": null,
      "units_per_spot": 1.0,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "Warehouse",
      "building_area_per_spot": 1000.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "QuickServiceRestaurant",
      "building_area_per_spot": 100.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "FullServiceRestaurant",
      "building_area_per_spot": 100.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "MidriseApartment",
      "building_area_per_spot": null,
      "units_per_spot": 0.45,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "HighriseApartment",
      "building_area_per_spot": null,
      "units_per_spot": 0.45,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "Based on Table 4.17 Illuminated Parking Area from Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010"
    },
    {
      "building_type": "SuperMarket",
      "building_area_per_spot": 285.7,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": "From NREL Reference Building (45002 ft^2 building/63810 ft^2 parking area at 405 per spot 157 spots)"
    },
    {
      "building_type": "Parking surface",
      "building_area_per_spot": null,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 405.0,
      "notes": null
    },
    {
      "building_type": "Parking garage",
      "building_area_per_spot": null,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": 486,
      "notes": null
    },
    {
      "building_type": "Courthouse",
      "building_area_per_spot": null,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": null,
      "notes": null
    },
    {
      "building_type": "SmallDataCenterLowITE",
      "building_area_per_spot": 0.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": null,
      "notes": null
    },
    {
      "building_type": "SmallDataCenterHighITE",
      "building_area_per_spot": 0.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": null,
      "notes": null
    },
    {
      "building_type": "LargeDataCenterLowITE",
      "building_area_per_spot": 0.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": null,
      "notes": null
    },
    {
      "building_type": "LargeDataCenterHighITE",
      "building_area_per_spot": 0.0,
      "units_per_spot": null,
      "students_per_spot": null,
      "beds_per_spot": null,
      "parking_area_per_spot": null,
      "notes": null
    }
  ]
}