{ "boilers": [ { "template": "DOE Ref Pre-1980", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 0.0, "maximum_capacity": 299999.0, "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.73, "minimum_combustion_efficiency": null, "efffplr": "Boiler Constant Efficiency Curve", "notes": "From DOE Reference Buildings" }, { "template": "DOE Ref Pre-1980", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 300000.0, "maximum_capacity": "9.999999999E9", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.74, "minimum_combustion_efficiency": null, "efffplr": "Boiler Constant Efficiency Curve", "notes": "From DOE Reference Buildings" }, { "template": "DOE Ref Pre-1980", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": "2.5E8", "maximum_capacity": "9.999999999E9", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.76, "minimum_combustion_efficiency": null, "efffplr": "Boiler Constant Efficiency Curve", "notes": "From DOE Reference Buildings" }, { "template": "DOE Ref 1980-2004", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 0.0, "maximum_capacity": 299999.0, "minimum_annual_fuel_utilization_efficiency": 0.8, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": null, "efffplr": "Boiler Constant Efficiency Curve", "notes": "From 90.1-1989" }, { "template": "DOE Ref 1980-2004", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 300000.0, "maximum_capacity": "2.49999999E8", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": 0.8, "efffplr": "Boiler Constant Efficiency Curve", "notes": "From 90.1-1989" }, { "template": "90.1-2004", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 0.0, "maximum_capacity": 299999.0, "minimum_annual_fuel_utilization_efficiency": 0.8, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2004" }, { "template": "90.1-2004", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 300000.0, "maximum_capacity": "2.49999999E8", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.75, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2004" }, { "template": "90.1-2004", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": "2.5E8", "maximum_capacity": "9.999999999E9", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": 0.8, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2004" }, { "template": "90.1-2007", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 0.0, "maximum_capacity": 299999.0, "minimum_annual_fuel_utilization_efficiency": 0.8, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2007" }, { "template": "90.1-2007", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 300000.0, "maximum_capacity": "2.49999999E8", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.8, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2007" }, { "template": "90.1-2007", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": "2.5E8", "maximum_capacity": "9.999999999E9", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": 0.82, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2007" }, { "template": "90.1-2010", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 0.0, "maximum_capacity": 299999.0, "minimum_annual_fuel_utilization_efficiency": 0.8, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2010" }, { "template": "90.1-2010", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 300000.0, "maximum_capacity": "2.49999999E8", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.8, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2010" }, { "template": "90.1-2010", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": "2.5E8", "maximum_capacity": "9.999999999E9", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": 0.82, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2010" }, { "template": "90.1-2013", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 0.0, "maximum_capacity": 299999.0, "minimum_annual_fuel_utilization_efficiency": 0.8, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2013" }, { "template": "90.1-2013", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 300000.0, "maximum_capacity": 999999.0, "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.8, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2013" }, { "template": "90.1-2013", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 1000000.0, "maximum_capacity": "2.49999999E8", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.8, "minimum_combustion_efficiency": null, "efffplr": "Boiler with Minimum Turndown", "notes": "From 90.1-2013" }, { "template": "90.1-2013", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": "2.5E8", "maximum_capacity": "9.999999999E9", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": 0.82, "efffplr": "Boiler with Minimum Turndown", "notes": "From 90.1-2013" }, { "template": "NECB 2011", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": "-", "maximum_capacity": 299999.0, "minimum_annual_fuel_utilization_efficiency": 0.85, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": null, "efffplr": "BOILER-EFFFPLR-NECB2011", "notes": "From NECB 2011" }, { "template": "NECB 2011", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 300000.0, "maximum_capacity": 2499999.0, "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.83, "minimum_combustion_efficiency": null, "efffplr": "BOILER-EFFFPLR-NECB2011", "notes": "From NECB 2011" }, { "template": "NECB 2011", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 2500000.0, "maximum_capacity": "###########", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": 0.833, "efffplr": "BOILER-EFFFPLR-NECB2011", "notes": "From NECB 2011" }, { "template": "NECB 2011", "fluid_type": "Hot Water", "fuel_type": "Electric", "minimum_capacity": "-", "maximum_capacity": "###########", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 1.0, "minimum_combustion_efficiency": null, "efffplr": "BOILER-EFFFPLR-NECB2011", "notes": "From NECB 2011" }, { "template": "NECB 2011", "fluid_type": "Hot Water", "fuel_type": "Oil", "minimum_capacity": "-", "maximum_capacity": 299999.0, "minimum_annual_fuel_utilization_efficiency": 0.8, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": null, "efffplr": "BOILER-EFFFPLR-NECB2011", "notes": "From NECB 2011" }, { "template": "NECB 2011", "fluid_type": "Hot Water", "fuel_type": "Oil", "minimum_capacity": 300000.0, "maximum_capacity": 2499999.0, "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.834, "minimum_combustion_efficiency": null, "efffplr": "BOILER-EFFFPLR-NECB2011", "notes": "From NECB 2011" }, { "template": "NECB 2011", "fluid_type": "Hot Water", "fuel_type": "Oil", "minimum_capacity": 2500000.0, "maximum_capacity": "9.999999999E9", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": 0.858, "efffplr": "BOILER-EFFFPLR-NECB2011", "notes": "From NECB 2011" }, { "template": "OEESC 2014", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 0.0, "maximum_capacity": 299999.0, "minimum_annual_fuel_utilization_efficiency": 0.8, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2013" }, { "template": "OEESC 2014", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 300000.0, "maximum_capacity": 999999.0, "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.8, "minimum_combustion_efficiency": null, "efffplr": "Boiler with No Minimum Turndown", "notes": "From 90.1-2013" }, { "template": "OEESC 2014", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": 1000000.0, "maximum_capacity": "2.49999999E8", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": 0.8, "minimum_combustion_efficiency": null, "efffplr": "Boiler with Minimum Turndown", "notes": "From 90.1-2013" }, { "template": "OEESC 2014", "fluid_type": "Hot Water", "fuel_type": "Gas", "minimum_capacity": "2.5E8", "maximum_capacity": "9.999999999E9", "minimum_annual_fuel_utilization_efficiency": null, "minimum_thermal_efficiency": null, "minimum_combustion_efficiency": 0.82, "efffplr": "Boiler with Minimum Turndown", "notes": "From 90.1-2013" } ] }