COMMAND COSMOS STARTLOGGING BIG_ENDIAN "Starts logging both commands and telemetry for an interface" APPEND_PARAMETER SYNC 32 UINT 0x1ACFFC1D 0x1ACFFC1D 0x1ACFFC1D "COSMOS Command Sync Pattern" APPEND_ID_PARAMETER OPCODE 32 UINT 2 2 2 "COSMOS Command Opcode" APPEND_PARAMETER LENGTH 32 UINT 0 65536 3 "COSMOS Command Length of Command Data in Bytes" APPEND_PARAMETER INTERFACE 256 STRING "ALL" "Interface to start logging on - ALL starts logging on all interfaces" APPEND_PARAMETER LABEL 0 STRING "" "Optional label to place on log files" COMMAND COSMOS STARTCMDLOG BIG_ENDIAN "Starts logging commands for an interface" APPEND_PARAMETER SYNC 32 UINT 0x1ACFFC1D 0x1ACFFC1D 0x1ACFFC1D "COSMOS Command Sync Pattern" APPEND_ID_PARAMETER OPCODE 32 UINT 3 3 3 "COSMOS Command Opcode" APPEND_PARAMETER LENGTH 32 UINT 0 65536 3 "COSMOS Command Length of Command Data in Bytes" APPEND_PARAMETER INTERFACE 256 STRING "ALL" "Interface to start logging on - ALL starts logging on all interfaces" APPEND_PARAMETER LABEL 0 STRING "" "Optional label to place on log files" COMMAND COSMOS STARTTLMLOG BIG_ENDIAN "Starts logging telemetry for an interface" APPEND_PARAMETER SYNC 32 UINT 0x1ACFFC1D 0x1ACFFC1D 0x1ACFFC1D "COSMOS Command Sync Pattern" APPEND_ID_PARAMETER OPCODE 32 UINT 4 4 4 "COSMOS Command Opcode" APPEND_PARAMETER LENGTH 32 UINT 0 65536 3 "COSMOS Command Length of Command Data in Bytes" APPEND_PARAMETER INTERFACE 256 STRING "ALL" "Interface to start logging on - ALL starts logging on all interfaces" APPEND_PARAMETER LABEL 0 STRING "" "Optional label to place on log files" COMMAND COSMOS STOPLOGGING BIG_ENDIAN "Stops logging both commands and telemetry for an interface" APPEND_PARAMETER SYNC 32 UINT 0x1ACFFC1D 0x1ACFFC1D 0x1ACFFC1D "COSMOS Command Sync Pattern" APPEND_ID_PARAMETER OPCODE 32 UINT 5 5 5 "COSMOS Command Opcode" APPEND_PARAMETER LENGTH 32 UINT 0 65536 3 "COSMOS Command Length of Command Data in Bytes" APPEND_PARAMETER INTERFACE 256 STRING "ALL" "Interface to stop logging on - ALL stops logging on all interfaces" APPEND_PARAMETER LABEL 0 STRING "" "Optional label to place on log files" COMMAND COSMOS STOPCMDLOG BIG_ENDIAN "Stops logging commands for an interface" APPEND_PARAMETER SYNC 32 UINT 0x1ACFFC1D 0x1ACFFC1D 0x1ACFFC1D "COSMOS Command Sync Pattern" APPEND_ID_PARAMETER OPCODE 32 UINT 6 6 6 "COSMOS Command Opcode" APPEND_PARAMETER LENGTH 32 UINT 0 65536 3 "COSMOS Command Length of Command Data in Bytes" APPEND_PARAMETER INTERFACE 256 STRING "ALL" "Interface to stop logging on - ALL stops logging on all interfaces" APPEND_PARAMETER LABEL 0 STRING "" "Optional label to place on log files" COMMAND COSMOS STOPTLMLOG BIG_ENDIAN "Stops logging telemetry for an interface" APPEND_PARAMETER SYNC 32 UINT 0x1ACFFC1D 0x1ACFFC1D 0x1ACFFC1D "COSMOS Command Sync Pattern" APPEND_ID_PARAMETER OPCODE 32 UINT 7 7 7 "COSMOS Command Opcode" APPEND_PARAMETER LENGTH 32 UINT 0 65536 3 "COSMOS Command Length of Command Data in Bytes" APPEND_PARAMETER INTERFACE 256 STRING "ALL" "Interface to stop logging on - ALL stops logging on all interfaces" APPEND_PARAMETER LABEL 0 STRING "" "Optional label to place on log files"