  "tables": {
    "space_types": {
      "data_type": "table",
      "refs": [
        "assumption"
      ],
      "table": [
        {
          "building_type": "Automotive facility",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Automotive facility",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.817539948,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Automotive facility",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002137,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Automotive Area",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 4.65,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Convention centre",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Convention centre",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.077666295,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 300,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Convention centre",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 11.61,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001781,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 11.61,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Conference rooms"
        },
        {
          "building_type": "Courthouse",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Courthouse",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.049795615,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Courthouse",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 6.19,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0019,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 6.19,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Offices-Conference rooms"
        },
        {
          "building_type": "Dining - bar/lounge",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Dining - bar/lounge",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.994054255,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 125,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Dining - bar/lounge",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 30,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.005462,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 9.29,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Food and Beverage Service-Bars, coctail lounges"
        },
        {
          "building_type": "Dining - cafeteria",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Dining - cafeteria",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.901151988,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 300,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Dining - cafeteria",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.005462,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 9.29,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Food and Beverage Service-Cafeteria, fast food"
        },
        {
          "building_type": "Dining - family",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Dining - family",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 300,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Dining - family",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.005462,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 9.29,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Food and Beverage Service-Dining rooms"
        },
        {
          "building_type": "Dormitory",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Dormitory",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.613154961,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Dormitory",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.007915,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Sleeping Area",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.1,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Dormitory sleeping areas"
        },
        {
          "building_type": "Exercise centre",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Exercise centre",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.882571535,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Exercise centre",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 25,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004274,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 9.29,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Sports and Amusement-Game rooms"
        },
        {
          "building_type": "Fire station",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Fire station",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.706057228,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Fire station",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.007599,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Automotive Area",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.72,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Enclosed parking garage"
        },
        {
          "building_type": "Gymnasium",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Gymnasium",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.003344482,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Gymnasium",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 25,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004274,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 9.29,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Sports and Amusement-Game rooms"
        },
        {
          "building_type": "Health-care clinic",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Health-care clinic",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.873281308,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 600,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Health-care clinic",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002137,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 4.65,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Hopital, Nursing and Convalescent Homes-Medical procedure"
        },
        {
          "building_type": "Hospital",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Hospital",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.207729469,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Hospital",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002137,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 4.65,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Hopital, Nursing and Convalescent Homes-Medical procedure"
        },
        {
          "building_type": "Hotel",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Hotel",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.003344482,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Hotel",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0.091,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.009498,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Residential/Accomodation Area",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.72,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Bedrooms (assume avg. bedroom is 330 ft2)"
        },
        {
          "building_type": "Library",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Library",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.179858789,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Library",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002137,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Historical Collections Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 4.65,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Education-Libraries"
        },
        {
          "building_type": "Manufacturing facility",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Manufacturing facility",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.105536975,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 450,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Manufacturing facility",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Industrial Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.1,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Motel",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Motel",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.882571535,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Motel",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0.091,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.009498,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Residential/Accomodation Area",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.72,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Bedrooms (assume avg. bedroom is 330 ft2)"
        },
        {
          "building_type": "Motion picture theatre",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Motion picture theatre",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.826830175,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Motion picture theatre",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 11.61,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001781,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 11.61,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Theaters-Auditorium"
        },
        {
          "building_type": "Multi-unit residential",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Multi-unit residential",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.603864734,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 125,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Multi-unit residential",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0.06,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 1.55,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.003958,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Residential/Accomodation Area",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 1.55,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Living areas (Table 2, assume 10 ft ceiling)"
        },
        {
          "building_type": "Museum",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Museum",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.059085842,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Museum",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Historical Collections Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 4.65,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Theaters-Lobbies"
        },
        {
          "building_type": "Office",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Office",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.901151988,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Office",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00171,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.72,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Offices-Office space"
        },
        {
          "building_type": "Parking garage",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Parking garage",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.25083612,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 75,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Parking garage",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.09,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Automotive Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0.09,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Enclosed parking garage"
        },
        {
          "building_type": "Penitentiary",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Penitentiary",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.966183575,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Penitentiary",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.006332,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Sleeping Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.1,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Correctional Facilities-Cells"
        },
        {
          "building_type": "Performing arts theatre",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Performing arts theatre",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.393534002,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Performing arts theatre",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 11.61,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001781,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 11.61,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Theaters-Auditorium"
        },
        {
          "building_type": "Police station",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Police station",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.956893348,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Police station",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00171,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.72,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Offices-Conference rooms"
        },
        {
          "building_type": "Post office",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Post office",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.873281308,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Post office",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00171,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.72,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Offices-Conference rooms"
        },
        {
          "building_type": "Religious",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Religious",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.049795615,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Religious",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 18.58,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Theaters-Auditorium"
        },
        {
          "building_type": "Retail",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Retail",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.402824229,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 450,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Retail",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0.3,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000633,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.1,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Basement and street"
        },
        {
          "building_type": "School/university",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "School/university",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.994054255,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "School/university",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 11.61,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.003562,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 11.61,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Education-Classrooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "- undefined -",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "- undefined -",
          "lighting_per_area": 0.0,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": null,
          "lighting_fraction_radiant": null,
          "lighting_fraction_visible": null,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": null,
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": null,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "N/A",
          "ventilation_primary_space_type": null,
          "ventilation_secondary_space_type": null,
          "ventilation_per_area": 0,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": null,
          "occupancy_schedule": null,
          "occupancy_activity_schedule": null,
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": null,
          "electric_equipment_fraction_latent": null,
          "electric_equipment_fraction_radiant": null,
          "electric_equipment_fraction_lost": null,
          "electric_equipment_schedule": null,
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": null,
          "cooling_setpoint_schedule": null,
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": null,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": null,
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": null,
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "- undefined -",
          "necb_schedule_type": "- undefined -",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "N/A",
          "ventilation_standard_space_type": "N/A"
        },
        {
          "building_type": "Space Function",
          "space_type": "Atrium - H < 13m",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Atrium - H < 13m",
          "lighting_per_area": 0.0,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Atrium - H < 13m",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Atrium - H > 13m",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Atrium - H > 13m",
          "lighting_per_area": 0.0,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Atrium - H > 13m",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Audience - auditorium",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Audience - auditorium",
          "lighting_per_area": 0.789669268,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Audience - auditorium",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002839298,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Theaters-Auditorium"
        },
        {
          "building_type": "Space Function",
          "space_type": "Audience - motion picture",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Audience - motion picture",
          "lighting_per_area": 1.142697882,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Audience - motion picture",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002839298,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Theaters-Auditorium"
        },
        {
          "building_type": "Space Function",
          "space_type": "Audience - performance arts",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Audience - performance arts",
          "lighting_per_area": 2.434039391,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Audience - performance arts",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 12.39,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001893375,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Theaters-Auditorium"
        },
        {
          "building_type": "Space Function",
          "space_type": "Automotive - repair",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Automotive - repair",
          "lighting_per_area": 0.668896321,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Automotive - repair",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Automotive Area",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Bank - banking and offices",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Bank - banking and offices",
          "lighting_per_area": 1.384243776,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Bank - banking and offices",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001142515,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 15,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Offices-Office space"
        },
        {
          "building_type": "Space Function",
          "space_type": "Classroom/lecture/training",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Classroom/lecture/training",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Classroom/lecture/training",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 12.39,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004120874,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 65,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Education-Classrooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Conf./meet./multi-purpose",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Conf./meet./multi-purpose",
          "lighting_per_area": 1.226309922,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Conf./meet./multi-purpose",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004286783,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 50,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Offices-Conference rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Convention centre - audience",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Convention centre - audience",
          "lighting_per_area": 0.817539948,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Convention centre - audience",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002839298,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Conference rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Convention centre - exhibit",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Convention centre - exhibit",
          "lighting_per_area": 1.449275362,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Convention centre - exhibit",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002839298,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Assembly rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. < 2.4m wide-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-A",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. < 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. < 2.4m wide-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-B",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. < 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. < 2.4m wide-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-C",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. < 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. < 2.4m wide-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-D",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. < 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. < 2.4m wide-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-E",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. < 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. < 2.4m wide-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-F",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. < 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. < 2.4m wide-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-G",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. < 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. < 2.4m wide-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-H",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. < 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. < 2.4m wide-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. < 2.4m wide-sch-I",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. < 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. >= 2.4m wide-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-A",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. >= 2.4m wide-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-B",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. >= 2.4m wide-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-C",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. >= 2.4m wide-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-D",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. >= 2.4m wide-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-E",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. >= 2.4m wide-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-F",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. >= 2.4m wide-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-G",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. >= 2.4m wide-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-H",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Corr. >= 2.4m wide-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Corr. >= 2.4m wide-sch-I",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Corr. >= 2.4m wide",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Courthouse - cell",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Courthouse - cell",
          "lighting_per_area": 1.365663322,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Courthouse - cell",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.006180727,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Sleeping Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 25,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Correctional Facilities-Cells"
        },
        {
          "building_type": "Space Function",
          "space_type": "Courthouse - chambers",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Courthouse - chambers",
          "lighting_per_area": 1.170568562,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Courthouse - chambers",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 5,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Offices-Office space"
        },
        {
          "building_type": "Space Function",
          "space_type": "Courthouse - courtroom",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Courthouse - courtroom",
          "lighting_per_area": 1.718691936,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Courthouse - courtroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002839298,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 70,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Offices-Conference rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Dining - bar lounge/leisure",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Dining - bar lounge/leisure",
          "lighting_per_area": 1.309921962,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Dining - bar lounge/leisure",
          "ventilation_per_area": 0,
          "ventilation_per_person": 30,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004272865,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 100,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Food and Beverage Service-Bars, coctail lounges"
        },
        {
          "building_type": "Space Function",
          "space_type": "Dining - family space",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Dining - family space",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Dining - family space",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.005692514,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 70,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Food and Beverage Service-Dining rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Dining - other",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Dining - other",
          "lighting_per_area": 0.650315868,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Dining - other",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.005692514,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 70,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Food and Beverage Service-Dining rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Dormitory - living quarters",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Dormitory - living quarters",
          "lighting_per_area": 0.380899294,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 125,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Dormitory - living quarters",
          "ventilation_per_area": 0.091,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.009507954,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Sleeping Area",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Bedrooms (assume avg. bedroom is 330 ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Dress./fitt. - performance arts",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Dress./fitt. - performance arts",
          "lighting_per_area": 0.399479747,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Dress./fitt. - performance arts",
          "ventilation_per_area": 0.2,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000631634,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Dwelling Unit(s)",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Dwelling Unit(s)",
          "lighting_per_area": 0.464511334,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 125,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Dwelling Unit(s)",
          "ventilation_per_area": 0.06,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 1.55,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.003961647,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Residential/Accomodation Area",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Living areas (Table 2, assume 10 ft ceiling)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Electrical/Mechanical-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Electrical/Mechanical-sch-A",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Electrical/Mechanical",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Electrical/Mechanical-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Electrical/Mechanical-sch-B",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Electrical/Mechanical",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Electrical/Mechanical-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Electrical/Mechanical-sch-C",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Electrical/Mechanical",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Electrical/Mechanical-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Electrical/Mechanical-sch-D",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Electrical/Mechanical",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Electrical/Mechanical-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Electrical/Mechanical-sch-E",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Electrical/Mechanical",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Electrical/Mechanical-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Electrical/Mechanical-sch-F",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Electrical/Mechanical",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Electrical/Mechanical-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Electrical/Mechanical-sch-G",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Electrical/Mechanical",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Electrical/Mechanical-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Electrical/Mechanical-sch-H",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Electrical/Mechanical",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Electrical/Mechanical-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Electrical/Mechanical-sch-I",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Electrical/Mechanical",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Fire station - engine room",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Fire station - engine room",
          "lighting_per_area": 0.557413601,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Fire station - engine room",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.006180727,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Automotive Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Enclosed parking garage"
        },
        {
          "building_type": "Space Function",
          "space_type": "Fire station - quarters",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Fire station - quarters",
          "lighting_per_area": 0.315867707,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Fire station - quarters",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.009507954,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Residential/Accomodation Area",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Hotel, Models, Resorts-Dormotory sleeping areas"
        },
        {
          "building_type": "Space Function",
          "space_type": "Food preparation",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Food preparation",
          "lighting_per_area": 0.994054255,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Food preparation",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002849321,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Food and Beverage Serices-Kitchens (cooking)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Food preparation - vented",
          "rgb": "255_255_256",
          "lighting_standard": "NECB 2012",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Food preparation",
          "lighting_per_area": 0.994054255,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Food preparation",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002849321,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area - vented",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Food and Beverage Serices-Kitchens (cooking)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Gym - audience",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Gym - audience",
          "lighting_per_area": 0.427350427,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Gym - audience",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002839298,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Sports and Amusement-Spectator areas"
        },
        {
          "building_type": "Space Function",
          "space_type": "Gym - fitness",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Gym - fitness",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Gym - fitness",
          "ventilation_per_area": 0,
          "ventilation_per_person": 25,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00854573,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 40,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Sports and Amusement-Game rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Gym - play",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Gym - play",
          "lighting_per_area": 1.198439242,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Gym - play",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.1393534,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00854573,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Sports and Amusement-Playing floors (gymnasium)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - emergency",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - emergency",
          "lighting_per_area": 2.257525084,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 600,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - emergency",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004277465,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Hopital, Nursing and Convalescent Homes-Medical procedure"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - exam",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - exam",
          "lighting_per_area": 1.662950576,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 600,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - exam",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Hopital, Nursing and Convalescent Homes-Medical procedure"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - laundry/washing",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - laundry/washing",
          "lighting_per_area": 0.743218135,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - laundry/washing",
          "ventilation_per_area": 0,
          "ventilation_per_person": 25,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 1.858045336,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001428144,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Dry Cleaners, Laundries-Commercial laundry"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - lounge/recreation",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - lounge/recreation",
          "lighting_per_area": 1.068376068,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - lounge/recreation",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002853216,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 120,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Assembly rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - medical supply",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - medical supply",
          "lighting_per_area": 1.272761055,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - medical supply",
          "ventilation_per_area": 0.15,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 15,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Storage rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - medical supply - occsens",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - medical supply",
          "lighting_per_area": 1.14548495,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - medical supply",
          "ventilation_per_area": 0.15,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 15,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Storage rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - nursery",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - nursery",
          "lighting_per_area": 0.882571535,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - nursery",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Hospitals, Nursing and Convalescent Homes-Recovery and ICU"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - nurses station",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - nurses station",
          "lighting_per_area": 0.873281308,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - nurses station",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001072849,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 60,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Offices-Reception areas"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - operating room",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - operating room",
          "lighting_per_area": 1.885916016,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 1000,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - operating room",
          "ventilation_per_area": 0,
          "ventilation_per_person": 30,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.007133752,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Hospitals, Nursing and Convalescent Homes-Operating rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - patient room",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - patient room",
          "lighting_per_area": 0.622445188,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - patient room",
          "ventilation_per_area": 0,
          "ventilation_per_person": 25,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Hospitals, Nursing and Convalescent Homes-Patient rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - pharmacy",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - pharmacy",
          "lighting_per_area": 1.142697882,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - pharmacy",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001072849,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Workrooms-Pharmacy"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - physical therapy",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - physical therapy",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - physical therapy",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001072849,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Hospitals, Nursing and Convalescent Homes->Physical therapy"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - radiology/imaging",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - radiology/imaging",
          "lighting_per_area": 1.319212189,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 225,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - radiology/imaging",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Workrooms-Darkrooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital - recovery",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital - recovery",
          "lighting_per_area": 1.151988109,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital - recovery",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004277465,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Hospitals, Nursing and Convalescent Homes-Recovery and ICU"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. < 2.4m-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-A",
          "lighting_per_area": 1.086956522,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. < 2.4m-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-B",
          "lighting_per_area": 1.086956522,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. < 2.4m-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-C",
          "lighting_per_area": 1.086956522,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. < 2.4m-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-D",
          "lighting_per_area": 1.086956522,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. < 2.4m-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-E",
          "lighting_per_area": 1.086956522,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. < 2.4m-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-F",
          "lighting_per_area": 1.086956522,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. < 2.4m-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-G",
          "lighting_per_area": 1.086956522,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. < 2.4m-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-H",
          "lighting_per_area": 1.086956522,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. < 2.4m-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. < 2.4m-sch-I",
          "lighting_per_area": 1.086956522,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. < 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. >= 2.4m-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-A",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. >= 2.4m-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-B",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. >= 2.4m-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-C",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. >= 2.4m-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-D",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. >= 2.4m-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-E",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. >= 2.4m-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-F",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. >= 2.4m-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-G",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. >= 2.4m-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-H",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hospital corr. >= 2.4m-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hospital corr. >= 2.4m-sch-I",
          "lighting_per_area": 0.891861761,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hospital corr. >= 2.4m",
          "ventilation_per_area": 0.1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Education-Corridors"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hotel/Motel - dining",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hotel/Motel - dining",
          "lighting_per_area": 0.817539948,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hotel/Motel - dining",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.005455906,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 70,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Food and Beverage Service-Dining rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hotel/Motel - lobby",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hotel/Motel - lobby",
          "lighting_per_area": 1.059085842,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hotel/Motel - lobby",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001419649,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Lobbies"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hotel/Motel - rooms",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hotel/Motel - rooms",
          "lighting_per_area": 1.105536975,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hotel/Motel - rooms",
          "ventilation_per_area": 0.091,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.01140843,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Residential/Accomodation Area",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Bedrooms (assume avg. bedroom is 330 ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hway lodging - dining",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hway lodging - dining",
          "lighting_per_area": 0.882571535,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hway lodging - dining",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.005455906,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 70,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Food and Beverage Service-Dining rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Hway lodging - rooms",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Hway lodging - rooms",
          "lighting_per_area": 0.752508361,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Hway lodging - rooms",
          "ventilation_per_area": 0.091,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.01140843,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Residential/Accomodation Area",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Bedrooms (assume avg. bedroom is 330 ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Lab - classrooms",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Lab - classrooms",
          "lighting_per_area": 1.597918989,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Lab - classrooms",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004277465,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 25,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Education-Classrooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Lab - research",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Lab - research",
          "lighting_per_area": 2.192493497,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 650,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Lab - research",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004277465,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Hospital Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 25,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Education-Laboratories"
        },
        {
          "building_type": "Space Function",
          "space_type": "Library - cataloging",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Library - cataloging",
          "lighting_per_area": 0.724637681,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Library - cataloging",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Education-Libraries"
        },
        {
          "building_type": "Space Function",
          "space_type": "Library - reading",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Library - reading",
          "lighting_per_area": 0.929022668,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Library - reading",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Education-Libraries"
        },
        {
          "building_type": "Space Function",
          "space_type": "Library - stacks",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Library - stacks",
          "lighting_per_area": 2.12746191,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Library - stacks",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Education-Libraries"
        },
        {
          "building_type": "Space Function",
          "space_type": "Lobby - elevator",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Lobby - elevator",
          "lighting_per_area": 0.641025641,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Lobby - elevator",
          "ventilation_per_area": 1,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Elevators"
        },
        {
          "building_type": "Space Function",
          "space_type": "Lobby - motion picture",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Lobby - motion picture",
          "lighting_per_area": 0.520252694,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Lobby - motion picture",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Theaters-Lobbies"
        },
        {
          "building_type": "Space Function",
          "space_type": "Lobby - other",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Lobby - other",
          "lighting_per_area": 0.901151988,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Lobby - other",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Theaters-Lobbies"
        },
        {
          "building_type": "Space Function",
          "space_type": "Lobby - performance arts",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Lobby - performance arts",
          "lighting_per_area": 1.997398737,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Lobby - performance arts",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Theaters-Lobbies"
        },
        {
          "building_type": "Space Function",
          "space_type": "Locker room-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Locker room-sch-A",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Locker room",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Locker and dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Locker room-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Locker room-sch-B",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Locker room",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Locker and dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Locker room-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Locker room-sch-C",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Locker room",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Locker and dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Locker room-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Locker room-sch-D",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Locker room",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Locker and dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Locker room-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Locker room-sch-E",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Locker room",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Locker and dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Locker room-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Locker room-sch-F",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Locker room",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Locker and dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Locker room-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Locker room-sch-G",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Locker room",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Locker and dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Locker room-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Locker room-sch-H",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Locker room",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Locker and dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Locker room-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Locker room-sch-I",
          "lighting_per_area": 0.910442215,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Locker room",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Locker and dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Lounge/recreation",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Lounge/recreation",
          "lighting_per_area": 0.873281308,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Lounge/recreation",
          "ventilation_per_area": 0,
          "ventilation_per_person": 30,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002853216,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 25,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Food and Beverage Service-Bars, coctail lounges"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - 7.5 <= bay H <= 15m",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - 7.5 <= bay H <= 15m",
          "lighting_per_area": 1.226309922,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - 7.5 <= bay H <= 15m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425822,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Industrial Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - bay H < 7.5m",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - bay H < 7.5m",
          "lighting_per_area": 1.189149015,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - bay H < 7.5m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425822,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Industrial Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - bay H > 15m",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - bay H > 15m",
          "lighting_per_area": 1.049795615,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - bay H > 15m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425822,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Industrial Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. < 2.4m-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-A",
          "lighting_per_area": 0.510962467,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. < 2.4m-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-B",
          "lighting_per_area": 0.510962467,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. < 2.4m-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-C",
          "lighting_per_area": 0.510962467,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. < 2.4m-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-D",
          "lighting_per_area": 0.510962467,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. < 2.4m-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-E",
          "lighting_per_area": 0.510962467,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. < 2.4m-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-F",
          "lighting_per_area": 0.510962467,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. < 2.4m-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-G",
          "lighting_per_area": 0.510962467,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. < 2.4m-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-H",
          "lighting_per_area": 0.510962467,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. < 2.4m-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. < 2.4m-sch-I",
          "lighting_per_area": 0.510962467,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. < 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. >= 2.4m-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-A",
          "lighting_per_area": 0.408769974,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. >= 2.4m-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-B",
          "lighting_per_area": 0.408769974,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. >= 2.4m-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-C",
          "lighting_per_area": 0.408769974,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. >= 2.4m-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-D",
          "lighting_per_area": 0.408769974,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. >= 2.4m-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-E",
          "lighting_per_area": 0.408769974,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. >= 2.4m-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-F",
          "lighting_per_area": 0.408769974,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. >= 2.4m-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-G",
          "lighting_per_area": 0.408769974,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. >= 2.4m-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-H",
          "lighting_per_area": 0.408769974,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - corr. >= 2.4m-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - corr. >= 2.4m-sch-I",
          "lighting_per_area": 0.408769974,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - corr. >= 2.4m",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - detailed",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - detailed",
          "lighting_per_area": 1.291341509,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 600,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - detailed",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425822,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Industrial Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Mfg - equipment",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Mfg - equipment",
          "lighting_per_area": 1.235600149,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 600,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Mfg - equipment",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425822,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Industrial Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Auto repair rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Museum - exhibition",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Museum - exhibition",
          "lighting_per_area": 1.049795615,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Museum - exhibition",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.005706432,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Historical Collections Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 40,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Theaters-Lobbies"
        },
        {
          "building_type": "Space Function",
          "space_type": "Museum - restoration",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Museum - restoration",
          "lighting_per_area": 1.021924935,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 600,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Museum - restoration",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001191281,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Historical Collections Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 10,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Workrooms-Photo studios"
        },
        {
          "building_type": "Space Function",
          "space_type": "Office - enclosed",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Office - enclosed",
          "lighting_per_area": 1.105536975,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Office - enclosed",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 5,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Offices-Office space"
        },
        {
          "building_type": "Space Function",
          "space_type": "Office - enclosed - occsens",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Office - enclosed",
          "lighting_per_area": 0.994983278,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Office - enclosed",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 5,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Offices-Office space"
        },
        {
          "building_type": "Space Function",
          "space_type": "Office - open plan",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Office - open plan",
          "lighting_per_area": 1.021924935,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Office - open plan",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 5,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Offices-Office space"
        },
        {
          "building_type": "Space Function",
          "space_type": "Parking garage space",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Parking garage space",
          "lighting_per_area": 0.185804534,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 75,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Parking garage space",
          "ventilation_per_area": 1.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.09,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Automotive Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Garages, Repair, Service Stations-Enclosed parking garage"
        },
        {
          "building_type": "Space Function",
          "space_type": "Penitentiary - audience",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Penitentiary - audience",
          "lighting_per_area": 0.427350427,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Penitentiary - audience",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002839298,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 70,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Offices-Conference rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Penitentiary - classroom",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Penitentiary - classroom",
          "lighting_per_area": 1.337792642,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Penitentiary - classroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 12.39,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.464511334,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004120874,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 65,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Education-Classrooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Penitentiary - dining",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Penitentiary - dining",
          "lighting_per_area": 1.068376068,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Penitentiary - dining",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.005692514,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Supermarket/Food Services Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 70,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Correctional Facilities-Dinning halls"
        },
        {
          "building_type": "Space Function",
          "space_type": "Post office sorting",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Post office sorting",
          "lighting_per_area": 0.938312895,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Post office sorting",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002138732,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 7,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Offices-Conference rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Religious - audience",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Religious - audience",
          "lighting_per_area": 1.690821256,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Religious - audience",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001419649,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 120,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Theaters-Auditorium"
        },
        {
          "building_type": "Space Function",
          "space_type": "Religious - fellowship hall",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Religious - fellowship hall",
          "lighting_per_area": 0.641025641,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Religious - fellowship hall",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004286783,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 120,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Hotels, Motels, Resorts-Assembly rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Religious - pulpit/choir",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Religious - pulpit/choir",
          "lighting_per_area": 1.690821256,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Religious - pulpit/choir",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001419649,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 120,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Education-Music rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Retail - dressing/fitting",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Retail - dressing/fitting",
          "lighting_per_area": 0.873281308,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 350,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Retail - dressing/fitting",
          "ventilation_per_area": 0.2,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000631634,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Dressing rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Retail - mall concourse",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Retail - mall concourse",
          "lighting_per_area": 1.096246748,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Retail - mall concourse",
          "ventilation_per_area": 0.2,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000710589,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 40,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Malls and arcades"
        },
        {
          "building_type": "Space Function",
          "space_type": "Retail - sales",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Retail - sales",
          "lighting_per_area": 1.681531029,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Retail - sales",
          "ventilation_per_area": 0.3,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000631634,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 15,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Basement and street"
        },
        {
          "building_type": "Space Function",
          "space_type": "Sales area",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Sales area",
          "lighting_per_area": 1.681531029,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Sales area",
          "ventilation_per_area": 0.3,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000631634,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 15,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Basement and street"
        },
        {
          "building_type": "Space Function",
          "space_type": "Sports arena - audience",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Sports arena - audience",
          "lighting_per_area": 0.427350427,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Sports arena - audience",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002839298,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 150,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Sports and Amusement-Spectator areas"
        },
        {
          "building_type": "Space Function",
          "space_type": "Sports arena - court c1",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Sports arena - court c1",
          "lighting_per_area": 3.010033445,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 1600,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Sports arena - court c1",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.1393534,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00854573,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Sports and Amusement-Ice arenaes (playing areas)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Sports arena - court c2",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Sports arena - court c2",
          "lighting_per_area": 1.923076923,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 1000,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Sports arena - court c2",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.1393534,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00854573,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Sports and Amusement-Ice arenaes (playing areas)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Sports arena - court c3",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Sports arena - court c3",
          "lighting_per_area": 1.198439242,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 800,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Sports arena - court c3",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.1393534,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00854573,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Sports and Amusement-Ice arenaes (playing areas)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Sports arena - court c4",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Sports arena - court c4",
          "lighting_per_area": 0.724637681,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Sports arena - court c4",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.1393534,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00854573,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Sports and Amusement-Ice arenaes (playing areas)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Sports arena - ring",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Sports arena - ring",
          "lighting_per_area": 2.675585284,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Sports arena - ring",
          "ventilation_per_area": 0.5,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 18.58,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.1393534,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00854573,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Sports and Amusement-Ice arenaes (playing areas)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Stairway-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Stairway-sch-A",
          "lighting_per_area": 0.687476774,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Stairway",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Stairway-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Stairway-sch-B",
          "lighting_per_area": 0.687476774,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Stairway",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Stairway-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Stairway-sch-C",
          "lighting_per_area": 0.687476774,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Stairway",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Stairway-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Stairway-sch-D",
          "lighting_per_area": 0.687476774,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Stairway",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Stairway-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Stairway-sch-E",
          "lighting_per_area": 0.687476774,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Stairway",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Stairway-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Stairway-sch-F",
          "lighting_per_area": 0.687476774,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Stairway",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Stairway-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Stairway-sch-G",
          "lighting_per_area": 0.687476774,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Stairway",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Stairway-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Stairway-sch-H",
          "lighting_per_area": 0.687476774,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Stairway",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Stairway-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Stairway-sch-I",
          "lighting_per_area": 0.687476774,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Stairway",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.46,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Public Spaces-Corridors and utilities"
        },
        {
          "building_type": "Space Function",
          "space_type": "Storage area",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Storage area",
          "lighting_per_area": 0.631735414,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Storage area",
          "ventilation_per_area": 0.15,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00142675,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 2,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Storage rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Storage area - occsens",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Storage area",
          "lighting_per_area": 0.568561873,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Storage area",
          "ventilation_per_area": 0.15,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00142675,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 2,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Storage rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Storage area - refrigerated",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Storage area",
          "lighting_per_area": 0.631735414,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Storage area",
          "ventilation_per_area": 0.15,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00142675,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 2,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Storage rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Storage area - refrigerated - occsens",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Storage area",
          "lighting_per_area": 0.568561873,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 100,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Storage area",
          "ventilation_per_area": 0.15,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00142675,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 2,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales Floors, and Show Room Floors-Storage rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Transp. baggage",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Transp. baggage",
          "lighting_per_area": 0.761798588,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Transp. baggage",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001546575,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 7,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Transportation-Platforms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Transp. concourse",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Transp. concourse",
          "lighting_per_area": 0.362318841,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Transp. concourse",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 4.65,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.003089824,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 100,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Transportation-Platforms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Transp. counter",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Transp. counter",
          "lighting_per_area": 1.077666295,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 250,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Transp. counter",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.232255667,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.003089824,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Transportation-Platforms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Transp. seating",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Transp. seating",
          "lighting_per_area": 0.538833148,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Transp. seating",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.0,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001546575,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 100,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Transportation-Waiting rooms"
        },
        {
          "building_type": "Space Function",
          "space_type": "Warehouse - fine",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Warehouse - fine",
          "lighting_per_area": 0.947603122,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 300,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Warehouse - fine",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 1.86,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00061863,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales floors, and Show Room Floors-Warehouses"
        },
        {
          "building_type": "Space Function",
          "space_type": "Warehouse - fine - refrigerated",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Warehouse - fine",
          "lighting_per_area": 0.947603122,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 300,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Warehouse - fine",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 1.86,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00061863,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales floors, and Show Room Floors-Warehouses"
        },
        {
          "building_type": "Space Function",
          "space_type": "Warehouse - med/blk",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Warehouse - med/blk",
          "lighting_per_area": 0.594574508,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Warehouse - med/blk",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000309315,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales floors, and Show Room Floors-Warehouses"
        },
        {
          "building_type": "Space Function",
          "space_type": "Warehouse - med/blk - refrigerated",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Warehouse - med/blk",
          "lighting_per_area": 0.594574508,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Warehouse - med/blk",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000309315,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales floors, and Show Room Floors-Warehouses"
        },
        {
          "building_type": "Space Function",
          "space_type": "Warehouse - med/blk2",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Warehouse - med/blk2",
          "lighting_per_area": 0.947603122,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Warehouse - med/blk2",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000309315,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales floors, and Show Room Floors-Warehouses"
        },
        {
          "building_type": "Space Function",
          "space_type": "Warehouse - med/blk2 - refrigerated",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Warehouse - med/blk2",
          "lighting_per_area": 0.947603122,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 200,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Warehouse - med/blk2",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.93,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.000309315,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Retail Stores, Sales floors, and Show Room Floors-Warehouses"
        },
        {
          "building_type": "Space Function",
          "space_type": "Washroom-sch-A",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Washroom-sch-A",
          "lighting_per_area": 0.975473802,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Washroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 50,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy (assumed)",
          "ventilation_standard_space_type": "Public Spaces-Public restroom (assume 30 people/1000ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Washroom-sch-B",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Washroom-sch-B",
          "lighting_per_area": 0.975473802,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Washroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 50,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy (assumed)",
          "ventilation_standard_space_type": "Public Spaces-Public restroom (assume 30 people/1000ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Washroom-sch-C",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Washroom-sch-C",
          "lighting_per_area": 0.975473802,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-C-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Washroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 50,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-C-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-C-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-C-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-C-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-C-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-C-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "C",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy (assumed)",
          "ventilation_standard_space_type": "Public Spaces-Public restroom (assume 30 people/1000ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Washroom-sch-D",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Washroom-sch-D",
          "lighting_per_area": 0.975473802,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Washroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 50,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy (assumed)",
          "ventilation_standard_space_type": "Public Spaces-Public restroom (assume 30 people/1000ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Washroom-sch-E",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Washroom-sch-E",
          "lighting_per_area": 0.975473802,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-E-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Washroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 50,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-E-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-E-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-E-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-E-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-E-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-E-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "E",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy (assumed)",
          "ventilation_standard_space_type": "Public Spaces-Public restroom (assume 30 people/1000ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Washroom-sch-F",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Washroom-sch-F",
          "lighting_per_area": 0.975473802,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-F-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Washroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 50,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-F-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-F-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-F-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-F-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-F-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-F-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "F",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy (assumed)",
          "ventilation_standard_space_type": "Public Spaces-Public restroom (assume 30 people/1000ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Washroom-sch-G",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Washroom-sch-G",
          "lighting_per_area": 0.975473802,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-G-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Washroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 50,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-G-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-G-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-G-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-G-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-G-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-G-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "G",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy (assumed)",
          "ventilation_standard_space_type": "Public Spaces-Public restroom (assume 30 people/1000ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Washroom-sch-H",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Washroom-sch-H",
          "lighting_per_area": 0.975473802,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Washroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 50,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy (assumed)",
          "ventilation_standard_space_type": "Public Spaces-Public restroom (assume 30 people/1000ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Washroom-sch-I",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Washroom-sch-I",
          "lighting_per_area": 0.975473802,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-I-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Washroom",
          "ventilation_per_area": 0,
          "ventilation_per_person": 50,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-I-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-I-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-I-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-I-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": 0.0,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.0,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-I-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-I-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Wildcard",
          "necb_schedule_type": "I",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 30,
          "ventilation_occupancy_standard": "ASHRAE 62-1999 Occupancy (assumed)",
          "ventilation_standard_space_type": "Public Spaces-Public restroom (assume 30 people/1000ft2)"
        },
        {
          "building_type": "Space Function",
          "space_type": "Workshop space",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Space Function",
          "lighting_secondary_space_type": "Workshop space",
          "lighting_per_area": 1.588628763,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Space Function",
          "ventilation_secondary_space_type": "Workshop space",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425822,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Industrial Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 20,
          "ventilation_occupancy_standard": "ASHRAE 62.1-2010 Occupancy (See NECB2011 ASHRAE Space Types)",
          "ventilation_standard_space_type": "Education-Traning shop"
        },
        {
          "building_type": "Sports arena",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Sports arena",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.780379041,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-B-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Sports arena",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 9.29,
          "occupancy_schedule": "NECB-B-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-B-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-B-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-B-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.004274,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-B-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-B-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "B",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.1,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Sports and Amusement-Spectator areas"
        },
        {
          "building_type": "Town hall",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Town hall",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.919732441,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-D-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 400,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Town hall",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.72,
          "occupancy_schedule": "NECB-D-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.696767001,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-D-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-D-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-D-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.00171,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-D-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-D-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Assembly Area",
          "necb_schedule_type": "D",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 9.29,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Offices-Conference rooms"
        },
        {
          "building_type": "Transportation",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Transportation",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.771088815,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-H-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 225,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Transportation",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 15,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 6.19,
          "occupancy_schedule": "NECB-H-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-H-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-H-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-H-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.002058,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-H-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-H-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "General Area",
          "necb_schedule_type": "H",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 3.72,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Transportation-Platforms"
        },
        {
          "building_type": "Warehouse",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Warehouse",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Warehouse",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.06,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 9.5e-05,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 6.19,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Retail Stores, Sales floors, and Show Room Floors-Warehouses"
        },
        {
          "building_type": "Warehouse - refrigerated",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Warehouse",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 0.659606094,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 150,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Warehouse",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0.05,
          "ventilation_per_person": 0,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 0.06,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.092902267,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 9.5e-05,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Warehouse Area - refrigerated",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0.06,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Retail Stores, Sales floors, and Show Room Floors-Warehouses"
        },
        {
          "building_type": "Workshop",
          "space_type": "WholeBuilding",
          "rgb": "255_255_255",
          "lighting_standard": "NECB2011",
          "lighting_primary_space_type": "Workshop",
          "lighting_secondary_space_type": "WholeBuilding",
          "lighting_per_area": 1.198439242,
          "lighting_per_person": null,
          "additional_lighting_per_area": null,
          "lighting_fraction_to_return_air": 0.0,
          "lighting_fraction_radiant": 0.5,
          "lighting_fraction_visible": 0.2,
          "lighting_fraction_replaceable": null,
          "lpd_fraction_linear_fluorescent": 1.0,
          "lpd_fraction_compact_fluorescent": null,
          "lpd_fraction_high_bay": null,
          "lpd_fraction_specialty_lighting": null,
          "lpd_fraction_exit_lighting": null,
          "lighting_schedule": "NECB-A-Lighting",
          "compact_fluorescent_lighting_schedule": null,
          "high_bay_lighting_schedule": null,
          "specialty_lighting_schedule": null,
          "exit_lighting_schedule": null,
          "target_illuminance_setpoint": 500,
          "target_illuminance_setpoint_ref": "IES 2011 Lighting Handbook",
          "psa_nongeometry_fraction": null,
          "ssa_nongeometry_fraction": null,
          "ventilation_standard": "ASHRAE 62-1999",
          "ventilation_primary_space_type": "Workshop",
          "ventilation_secondary_space_type": "WholeBuilding",
          "ventilation_per_area": 0,
          "ventilation_per_person": 20,
          "ventilation_air_changes": 0,
          "minimum_total_air_changes": null,
          "occupancy_per_area": 3.1,
          "occupancy_schedule": "NECB-A-Occupancy",
          "occupancy_activity_schedule": "NECB-Activity",
          "infiltration_per_exterior_area": 0.049225,
          "infiltration_per_exterior_wall_area": null,
          "infiltration_air_changes": null,
          "infiltration_schedule": "Always On",
          "infiltration_schedule_perimeter": null,
          "gas_equipment_per_area": null,
          "gas_equipment_fraction_latent": null,
          "gas_equipment_fraction_radiant": null,
          "gas_equipment_fraction_lost": null,
          "gas_equipment_schedule": null,
          "electric_equipment_per_area": 0.929022668,
          "electric_equipment_fraction_latent": 0.0,
          "electric_equipment_fraction_radiant": 0.5,
          "electric_equipment_fraction_lost": 0.0,
          "electric_equipment_schedule": "NECB-A-Electric-Equipment",
          "additional_electric_equipment_schedule": null,
          "additional_gas_equipment_schedule": null,
          "heating_setpoint_schedule": "NECB-A-Thermostat Setpoint-Heating",
          "cooling_setpoint_schedule": "NECB-A-Thermostat Setpoint-Cooling",
          "service_water_heating_peak_flow_rate": null,
          "service_water_heating_area": null,
          "service_water_heating_peak_flow_per_area": 0.001425,
          "service_water_heating_target_temperature": 60.0,
          "service_water_heating_fraction_sensible": null,
          "service_water_heating_fraction_latent": null,
          "service_water_heating_schedule": "NECB-A-Service Water Heating",
          "exhaust_per_area": null,
          "exhaust_fan_efficiency": null,
          "exhaust_fan_power": null,
          "exhaust_fan_pressure_rise": null,
          "exhaust_fan_maximum_flow_rate": null,
          "exhaust_schedule": "NECB-A-FAN",
          "balanced_exhaust_fraction_schedule": null,
          "is_residential": null,
          "necb_hvac_system_selection_type": "Industrial Area",
          "necb_schedule_type": "A",
          "notes": null,
          "ventilation_occupancy_rate_people_per_1000ft2": 0.06,
          "ventilation_occupancy_standard": "NECB Occupancy",
          "ventilation_standard_space_type": "Education-Traning shop"
        }
      ]
    }
  }
}