This measure extracts key simulation results and performs basic model QAQC checks. Each category of checks provides a description of the source of the check. In some cases the target standards and tollerances are adjustable.
Reads the model and sql file to pull out the necessary information and run the model checks. The check results show up as warning messages in the measure's output on the PAT run tab.
template
Target ASHRAE Standard
This used to set the target standard for most checks.
Choice
true
false
90.1-2013
DOE Ref Pre-1980
DOE Ref Pre-1980
DOE Ref 1980-2004
DOE Ref 1980-2004
90.1-2004
90.1-2004
90.1-2007
90.1-2007
90.1-2010
90.1-2010
90.1-2013
90.1-2013
90.1-2016
90.1-2016
90.1-2019
90.1-2019
ComStock DOE Ref Pre-1980
ComStock DOE Ref Pre-1980
ComStock DOE Ref 1980-2004
ComStock DOE Ref 1980-2004
ComStock 90.1-2004
ComStock 90.1-2004
ComStock 90.1-2007
ComStock 90.1-2007
ComStock 90.1-2010
ComStock 90.1-2010
ComStock 90.1-2013
ComStock 90.1-2013
check_eui_reasonableness
EUI Reasonableness (General)
Check model EUI against selected ASHRAE standard DOE prototype building.
Boolean
true
false
true
true
true
false
false
check_eui_reasonableness_tol
EUI Reasonableness Tolerance
Double
fraction
true
false
0.1
check_eui_by_end_use
End Use by Category (General)
Check model consumption by end use against selected ASHRAE standard DOE prototype building.
Boolean
true
false
true
true
true
false
false
check_eui_by_end_use_tol
End Use by Category Tolerance
Double
fraction
true
false
0.25
check_mech_sys_part_load_eff
Mechanical System Part Load Efficiency (General)
Check 40% and 80% part load efficency against selected ASHRAE standard for the following compenent types: ChillerElectricEIR, CoilCoolingDXSingleSpeed, CoilCoolingDXTwoSpeed, CoilHeatingDXSingleSpeed. Checking EIR Function of Part Load Ratio curve for chiller and EIR Function of Flow Fraction for DX coils.
Boolean
true
false
true
true
true
false
false
check_mech_sys_part_load_eff_tol
Mechanical System Part Load Efficiency Tolerance
Double
fraction
true
false
0.05
check_mech_sys_capacity
Mechanical System Capacity (General)
Check HVAC capacity against ASHRAE rules of thumb for chiller max flow rate, air loop max flow rate, air loop cooling capciaty, and zone heating capcaity. Zone heating check will skip thermal zones without any exterior exposure, and thermal zones that are not conditioned.
Boolean
true
false
true
true
true
false
false
check_simultaneous_heating_and_cooling
Simultaneous Heating and Cooling (General)
Check for simultaneous heating and cooling by looping through all Single Duct VAV Reheat Air Terminals and analyzing hourly data when there is a cooling load.
Boolean
true
false
true
true
true
false
false
check_simultaneous_heating_and_cooling_max_tol
Simultaneous Heating and Cooling Max Tolerance
Double
fraction
true
false
0.05
check_internal_loads
Internal Loads (Baseline)
Check LPD, ventilation rates, occupant density, plug loads, and equipment loads against selected ASHRAE standard DOE Prototype buildings.
Boolean
true
false
true
true
true
false
false
check_internal_loads_tol
Internal Loads Tolerance
Double
fraction
true
false
0.1
check_schedules
Schedules (Baseline)
Check schedules for lighting, ventilation, occupant density, plug loads, and equipment based on DOE reference building schedules in terms of full load hours per year.
Boolean
true
false
true
true
true
false
false
check_schedules_tol
Schedules Tolerance
Double
fraction
true
false
0.05
check_envelope_conductance
Envelope R-Value (Baseline)
Check envelope against selected ASHRAE standard. Roof reflectance of 55%, wall relfectance of 30%.
Boolean
true
false
true
true
true
false
false
check_envelope_conductance_tol
Envelope R-Value Tolerance
Double
fraction
true
false
0.1
check_domestic_hot_water
Domestic Hot Water (Baseline)
Check against the 2011 ASHRAE Handbook - HVAC Applications, Table 7 section 50.14.
Boolean
true
false
true
true
true
false
false
check_domestic_hot_water_tol
Domestic Hot Water Tolerance
Double
fraction
true
false
0.25
check_mech_sys_efficiency
Mechanical System Efficiency (Baseline)
Check against selected ASHRAE standard for the following component types: ChillerElectricEIR, CoilCoolingDXSingleSpeed, CoilCoolingDXTwoSpeed, CoilHeatingDXSingleSpeed, BoilerHotWater, FanConstantVolume, FanVariableVolume, PumpConstantSpeed, PumpVariableSpeed.
Boolean
true
false
true
true
true
false
false
check_mech_sys_efficiency_tol
Mechanical System Efficiency Tolerance
Double
fraction
true
false
0.1
check_mech_sys_type
Baseline Mechanical System Type (Baseline)
Check against ASHRAE 90.1. Infers the baseline system type based on the equipment serving the zone and their heating/cooling fuels. Only does a high-level inference; does not look for the presence/absence of required controls, etc.
Boolean
true
false
true
true
true
false
false
check_supply_air_and_thermostat_temp_difference
Supply and Zone Air Temperature (Baseline)
Check if fans modeled to ASHRAE 90.1 2013 Section G3.1.2.9 requirements. Compare the supply air temperature for each thermal zone against the thermostat setpoints. Throw flag if temperature difference excedes threshold of 20.0F plus the selected tolerance.
Boolean
true
false
true
true
true
false
false
check_supply_air_and_thermostat_temp_difference_tol
Supply and Zone Air Temperature Tolerance
Double
F
true
false
0.5
use_upstream_args
Use Upstream Argument Values
When true this will look for arguments or registerValues in upstream measures that match arguments from this measure, and will use the value from the upstream measure in place of what is entered for this measure.
Boolean
true
false
true
true
true
false
false
Reporting.QAQC
Uses SketchUp API
false
boolean
Intended Software Tool
OpenStudio Application
string
Intended Software Tool
Parametric Analysis Tool
string
Intended Use Case
Automatic Report Generation
string
Measure Type
ReportingMeasure
string
Intended Software Tool
OpenStudio Application
string
Intended Software Tool
Parametric Analysis Tool
string
Intended Use Case
Automatic Report Generation
string
USA_CO_Golden-NREL.724666_TMY3.epw
epw
test
BDF687C1
USA_TX_Austin-Camp.Mabry.722544_TMY3.epw
epw
test
FB60E24C
USA_TX_Austin-Mueller.Muni.AP.722540_TMY3.epw
epw
test
B5BB1762
design_doc.txt
txt
resource
779C47A4
BasicOfficeTest.osm
osm
test
75942985
BasicOfficeTest_Mueller_altHVAC_a.osm
osm
test
2B03A487
BasicOfficeTest_Mabry.osm
osm
test
601A4415
BasicOfficeTest_Mueller.osm
osm
test
C57E800F
BasicOfficeTest_Mueller_altHVAC_b.osm
osm
test
F12AB925
0422_test_b_sm_off.osm
osm
test
E797C12A
LICENSE.md
md
license
A21A3ED2
check_plant_cap.rb
rb
resource
5808A837
check_part_loads.rb
rb
resource
C56D1570
check_fan_pwr.rb
rb
resource
F32BF92B
check_placeholder.rb
rb
resource
C9561EBD
check_plenum_loads.rb
rb
resource
46981891
check_sch_coord.rb
rb
resource
B17FFC25
check_air_sys_temps.rb
rb
resource
C76C4A0C
check_plant_temps.rb
rb
resource
A659EBCD
check_pump_pwr.rb
rb
resource
4B6EC8EA
check_weather_files.rb
rb
resource
85CA2E26
check_calibration.rb
rb
resource
8D1854A4
CreateResults.rb
rb
resource
D38441F3
README.md.erb
erb
readmeerb
3AFCE991
generic_qaqc_summary.jpg
jpg
doc
45ABEE68
generic_qaqc_detailed.jpg
jpg
doc
92EA3F5C
OpenStudio
2.0.0
3.1.0
measure.rb
rb
script
9482E15C
fsr.osm
osm
test
D2A4E538
uo_blend.osm
osm
test
605CDF17
uo_strip_mall.osm
osm
test
95EBB09E
uo_lg_hotel.osm
osm
test
B8033381
USA_NY_Buffalo-Greater.Buffalo.Intl.AP.725280_TMY3.epw
epw
test
6B50E0FF
uo_mixed.osm
osm
test
1874C555
check_mech_sys_type.rb
rb
resource
2B4C8CB1
check_supply_air_and_thermostat_temp_difference.rb
rb
resource
245963C6
check_simultaneous_heating_and_cooling.rb
rb
resource
FAEFC26D
check_cond_zns.rb
rb
resource
35AF3348
check_mech_sys_capacity.rb
rb
resource
D4C11C12
check_mech_sys_efficiency.rb
rb
resource
5239DDEA
check_schedules.rb
rb
resource
4381DA3F
check_internal_loads.rb
rb
resource
8770A7D0
check_domestic_hot_water.rb
rb
resource
43606255
check_mech_sys_part_load_eff.rb
rb
resource
87A54A27
os_lib_reporting_qaqc.rb
rb
resource
579D7C6B
check_eui_reasonableness.rb
rb
resource
E6A6A3EB
check_eui_by_end_use.rb
rb
resource
3CB3F8D4
README.md
md
readme
11DDEADA
measure_Test.rb
rb
test
EA00F910
MidRiseApt.osm
osm
test
8316418F
check_envelope_conductance.rb
rb
resource
3346FDCD
report.html.erb
erb
resource
6F54D1FE