{ "construction_sets": [ { "template": "DOE Ref Pre-1980", "building_type": "Any", "space_type": "Attic", "is_residential": "No", "exterior_wall_standards_construction_type": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "WoodFramed", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Attic and Other", "exterior_roof_building_category": "Nonresidential", "interior_walls": null, "interior_floors": "Plenum Acoustical Tile", "interior_ceilings": null, "ground_contact_wall_standards_construction_type": null, "ground_contact_wall_building_category": null, "ground_contact_floor_standards_construction_type": null, "ground_contact_floor_building_category": null, "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": null, "exterior_fixed_window_standards_construction_type": null, "exterior_fixed_window_building_category": null, "exterior_operable_window_standards_construction_type": null, "exterior_operable_window_building_category": null, "exterior_door_standards_construction_type": null, "exterior_door_building_category": null, "exterior_glass_door_standards_construction_type": null, "exterior_glass_door_building_category": null, "exterior_overhead_door_standards_construction_type": null, "exterior_overhead_door_building_category": null, "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": null, "tubular_daylight_diffusers": null, "interior_fixed_windows": null, "interior_operable_windows": null, "interior_doors": null, "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": null, "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Any", "space_type": "Plenum", "is_residential": "No", "exterior_wall_standards_construction_type": null, "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": null, "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": null, "exterior_roof_building_category": "Nonresidential", "interior_walls": null, "interior_floors": "Plenum Acoustical Tile", "interior_ceilings": null, "ground_contact_wall_standards_construction_type": null, "ground_contact_wall_building_category": null, "ground_contact_floor_standards_construction_type": null, "ground_contact_floor_building_category": null, "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": null, "exterior_fixed_window_standards_construction_type": null, "exterior_fixed_window_building_category": null, "exterior_operable_window_standards_construction_type": null, "exterior_operable_window_building_category": null, "exterior_door_standards_construction_type": null, "exterior_door_building_category": null, "exterior_glass_door_standards_construction_type": null, "exterior_glass_door_building_category": null, "exterior_overhead_door_standards_construction_type": null, "exterior_overhead_door_building_category": null, "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": null, "tubular_daylight_diffusers": null, "interior_fixed_windows": null, "interior_operable_windows": null, "interior_doors": null, "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": null, "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Courthouse", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "FullServiceRestaurant", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": "PatRoom", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Residential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Residential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Hospital", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": "GuestRoom", "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Residential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Residential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeHotel", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": "listed as \"Crawl\" (crawlspace) in DEER" }, { "template": "DOE Ref Pre-1980", "building_type": "LargeOffice", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "LargeOfficeDetailed", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "MediumOffice", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "MediumOfficeDetailed", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "MidriseApartment", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Residential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Residential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Office", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Outpatient", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "SteelFramed", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "PrimarySchool", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "QuickServiceRestaurant", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Retail", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": "Note \"occupied' as default spacetype" }, { "template": "DOE Ref Pre-1980", "building_type": "SecondarySchool", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallHotel", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "Attic and Other", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallOffice", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Residential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "SmallOfficeDetailed", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Residential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Mass", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "StripMall", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "SteelFramed", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "SuperMarket", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "Mass", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Nonresidential", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Nonresidential", "exterior_glass_door_standards_construction_type": "Metal framing (entrance door)", "exterior_glass_door_building_category": "Nonresidential", "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Nonresidential", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Warehouse", "space_type": "Bulk", "is_residential": "No", "exterior_wall_standards_construction_type": "Metal Building", "exterior_wall_building_category": "Semiheated", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Semiheated", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Semiheated", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Semiheated", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Semiheated", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Semiheated", "exterior_glass_door_standards_construction_type": null, "exterior_glass_door_building_category": null, "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Semiheated", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Warehouse", "space_type": "Fine", "is_residential": "No", "exterior_wall_standards_construction_type": "Metal Building", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Semiheated", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Semiheated", "exterior_glass_door_standards_construction_type": null, "exterior_glass_door_building_category": null, "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Semiheated", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Warehouse", "space_type": "Office", "is_residential": "No", "exterior_wall_standards_construction_type": "Metal Building", "exterior_wall_building_category": "Nonresidential", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Nonresidential", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Semiheated", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Semiheated", "exterior_glass_door_standards_construction_type": null, "exterior_glass_door_building_category": null, "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Semiheated", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null }, { "template": "DOE Ref Pre-1980", "building_type": "Warehouse", "space_type": null, "is_residential": "No", "exterior_wall_standards_construction_type": "Metal Building", "exterior_wall_building_category": "Semiheated", "exterior_floor_standards_construction_type": "Mass", "exterior_floor_building_category": "Nonresidential", "exterior_roof_standards_construction_type": "IEAD", "exterior_roof_building_category": "Semiheated", "interior_walls": "Typical Interior Wall", "interior_floors": "Typical Interior Floor", "interior_ceilings": "Typical Interior Ceiling", "ground_contact_wall_standards_construction_type": "Mass", "ground_contact_wall_building_category": "Nonresidential", "ground_contact_floor_standards_construction_type": "Unheated", "ground_contact_floor_building_category": "Semiheated", "ground_contact_ceiling_standards_construction_type": null, "ground_contact_ceiling_building_category": "Nonresidential", "exterior_fixed_window_standards_construction_type": "Metal framing (all other)", "exterior_fixed_window_building_category": "Nonresidential", "exterior_operable_window_standards_construction_type": "Metal framing (all other)", "exterior_operable_window_building_category": "Nonresidential", "exterior_door_standards_construction_type": "Swinging", "exterior_door_building_category": "Semiheated", "exterior_glass_door_standards_construction_type": null, "exterior_glass_door_building_category": null, "exterior_overhead_door_standards_construction_type": "NonSwinging", "exterior_overhead_door_building_category": "Semiheated", "exterior_skylight_standards_construction_type": null, "exterior_skylight_building_category": null, "tubular_daylight_domes": "Typical Interior Window", "tubular_daylight_diffusers": "Typical Interior Window", "interior_fixed_windows": "Typical Interior Window", "interior_operable_windows": "Typical Interior Window", "interior_doors": "Typical Interior Door", "space_shading": null, "building_shading": null, "site_shading": null, "interior_partitions": "Typical Interior Partition", "notes": null } ] }