adjust_thermostat_setpoints_by_degrees_for_peak_hours
06ca2e04-87a2-4a83-b90a-fcc308a0b5a6
ff156dd5-add7-46c8-9a3f-10ed96273fdd
20210406T072941Z
4F7846F2
AdjustThermostatSetpointsByDegreesForPeakHours
Adjust thermostat setpoint by degrees for peak hours
This measure adjusts heating and cooling setpoints by a user-specified number of degrees and a user-specified time period. This is applied throughout the entire building.
This measure will clone all of the schedules that are used as heating and cooling setpoints for thermal zones. The clones are hooked up to the thermostat in place of the original schedules. Then the schedules are adjusted by the specified values during a specified time period. There is a checkbox to determine if the thermostat for design days should be altered.
cooling_adjustment
Degrees Fahrenheit to Adjust Cooling Setpoint By
Double
true
false
2
cooling_daily_starttime
Daily Start Time for Cooling Adjustment
String
false
false
16:01:00
cooling_daily_endtime
Daily End Time for Cooling Adjustment
String
false
false
20:00:00
cooling_startdate
Start Date for Cooling Adjustment
String
false
false
2009-Jun-01
cooling_enddate
End Date for Cooling Adjustment
String
false
false
2009-Sep-30
heating_adjustment
Degrees Fahrenheit to Adjust heating Setpoint By
Double
true
false
-2
heating_daily_starttime
Start Time for Heating Adjustment
String
false
false
18:01:00
heating_daily_endtime
End Time for Heating Adjustment
String
false
false
22:00:00
heating_startdate_1
Start Date for Heating Adjustment
String
false
false
2009-Jan-01
heating_enddate_1
End Date for Heating Adjustment
String
false
false
2009-May-31
heating_startdate_2
Start Date for Heating Adjustment
String
false
false
2009-Oct-01
heating_enddate_2
End Date for Heating Adjustment
String
false
false
2009-Dec-31
alter_design_days
Alter Design Day Thermostats
Boolean
false
false
false
true
true
false
false
auto_date
Enable Climate-specific Periods Setting?
Boolean
false
false
true
true
true
false
false
alt_periods
Alternate Peak and Take Periods
Boolean
false
false
false
true
true
false
false
HVAC.HVAC Controls
Measure Type
ModelMeasure
string
Measure Function
Measure
string
Requires EnergyPlus Results
false
boolean
Uses SketchUp API
false
boolean