{ "space_types": [ { "template": "CBES T24 2001", "building_type": "Office", "space_type": "Attic", "lighting_standard": null, "lighting_primary_space_type": null, "lighting_secondary_space_type": null, "lighting_per_area": null, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": null, "lighting_fraction_radiant": null, "lighting_fraction_visible": null, "lighting_fraction_replaceable": null, "lpd_fraction_linear_fluorescent": null, "lpd_fraction_compact_fluorescent": null, "lpd_fraction_high_bay": null, "lpd_fraction_specialty_lighting": null, "lpd_fraction_exit_lighting": null, "lighting_schedule": null, "compact_fluorescent_lighting_schedule": null, "high_bay_lighting_schedule": null, "specialty_lighting_schedule": null, "exit_lighting_schedule": null, "target_illuminance_setpoint": null, "psa_nongeometry_fraction": null, "ssa_nongeometry_fraction": null, "notes": null, "ventilation_standard": null, "ventilation_primary_space_type": null, "ventilation_secondary_space_type": null, "ventilation_per_area": null, "ventilation_per_person": null, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": null, "occupancy_schedule": null, "occupancy_activity_schedule": null, "is_residential": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": null, "infiltration_air_changes": null, "infiltration_schedule": null, "infiltration_schedule_perimeter": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": null, "electric_equipment_fraction_latent": null, "electric_equipment_fraction_radiant": null, "electric_equipment_fraction_lost": null, "electric_equipment_schedule": null, "additional_electric_equipment_schedule": null, "additional_gas_equipment_schedule": null, "heating_setpoint_schedule": null, "cooling_setpoint_schedule": null, "service_water_heating_peak_flow_rate": null, "service_water_heating_area": null, "service_water_heating_peak_flow_per_area": null, "service_water_heating_system_type": null, "booster_water_heater_fraction": null, "service_water_heating_target_temperature": null, "booster_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": null, "service_water_heating_fraction_latent": null, "service_water_heating_schedule": null, "exhaust_per_area": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_availability_schedule": null, "exhaust_flow_fraction_schedule": null, "balanced_exhaust_fraction_schedule": null }, { "template": "CBES T24 2001", "building_type": "Office", "space_type": "WholeBuilding - Md Office", "lighting_standard": "CBES T24 2001", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "WholeBuilding - Md Office", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_fraction_replaceable": null, "lpd_fraction_linear_fluorescent": 1.0, "lpd_fraction_compact_fluorescent": null, "lpd_fraction_high_bay": null, "lpd_fraction_specialty_lighting": null, "lpd_fraction_exit_lighting": null, "lighting_schedule": "OfficeLights", "compact_fluorescent_lighting_schedule": null, "high_bay_lighting_schedule": null, "specialty_lighting_schedule": null, "exit_lighting_schedule": null, "target_illuminance_setpoint": null, "psa_nongeometry_fraction": null, "ssa_nongeometry_fraction": null, "notes": null, "ventilation_standard": "CBES T24 2001", "ventilation_primary_space_type": "Office", "ventilation_secondary_space_type": "WholeBuilding - Md Office", "ventilation_per_area": 0.15, "ventilation_per_person": 15.0, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeOccupancy", "occupancy_activity_schedule": "OfficePeopleActivityLevel", "is_residential": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.22, "infiltration_air_changes": null, "infiltration_schedule": "OfficeInfiltration", "infiltration_schedule_perimeter": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.18, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeReceptacle", "additional_electric_equipment_schedule": null, "additional_gas_equipment_schedule": null, "heating_setpoint_schedule": "OfficeHtgSetpt", "cooling_setpoint_schedule": "OfficeClgSetpt", "service_water_heating_peak_flow_rate": 51.0, "service_water_heating_area": 53628.0, "service_water_heating_peak_flow_per_area": 0.000950996, "service_water_heating_system_type": "Shared", "booster_water_heater_fraction": null, "service_water_heating_target_temperature": 110.0, "booster_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeServiceHotWater", "exhaust_per_area": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_availability_schedule": null, "exhaust_flow_fraction_schedule": null, "balanced_exhaust_fraction_schedule": null }, { "template": "CBES T24 2001", "building_type": "Office", "space_type": "WholeBuilding - Sm Office", "lighting_standard": "CBES T24 2001", "lighting_primary_space_type": "Office", "lighting_secondary_space_type": "WholeBuilding - Sm Office", "lighting_per_area": 1.17, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_fraction_replaceable": null, "lpd_fraction_linear_fluorescent": 1.0, "lpd_fraction_compact_fluorescent": null, "lpd_fraction_high_bay": null, "lpd_fraction_specialty_lighting": null, "lpd_fraction_exit_lighting": null, "lighting_schedule": "OfficeLights", "compact_fluorescent_lighting_schedule": null, "high_bay_lighting_schedule": null, "specialty_lighting_schedule": null, "exit_lighting_schedule": null, "target_illuminance_setpoint": null, "psa_nongeometry_fraction": null, "ssa_nongeometry_fraction": null, "notes": null, "ventilation_standard": "CBES T24 2001", "ventilation_primary_space_type": "Office", "ventilation_secondary_space_type": "WholeBuilding - Sm Office", "ventilation_per_area": 0.15, "ventilation_per_person": 15.0, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": 10.0, "occupancy_schedule": "OfficeOccupancy", "occupancy_activity_schedule": "OfficePeopleActivityLevel", "is_residential": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.22, "infiltration_air_changes": null, "infiltration_schedule": "OfficeInfiltration", "infiltration_schedule_perimeter": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.18, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "OfficeReceptacle", "additional_electric_equipment_schedule": null, "additional_gas_equipment_schedule": null, "heating_setpoint_schedule": "OfficeHtgSetpt", "cooling_setpoint_schedule": "OfficeClgSetpt", "service_water_heating_peak_flow_rate": 3.0, "service_water_heating_area": 5502.0, "service_water_heating_peak_flow_per_area": 0.000545256, "service_water_heating_system_type": "Shared", "booster_water_heater_fraction": null, "service_water_heating_target_temperature": 110.0, "booster_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "OfficeServiceHotWater", "exhaust_per_area": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_availability_schedule": null, "exhaust_flow_fraction_schedule": null, "balanced_exhaust_fraction_schedule": null }, { "template": "CBES T24 2001", "building_type": "Retail", "space_type": "Back_Space", "lighting_standard": "CBES T24 2001", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Back_Space", "lighting_per_area": 0.6, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_fraction_replaceable": null, "lpd_fraction_linear_fluorescent": 1.0, "lpd_fraction_compact_fluorescent": null, "lpd_fraction_high_bay": null, "lpd_fraction_specialty_lighting": null, "lpd_fraction_exit_lighting": null, "lighting_schedule": "RetailLights", "compact_fluorescent_lighting_schedule": null, "high_bay_lighting_schedule": null, "specialty_lighting_schedule": null, "exit_lighting_schedule": null, "target_illuminance_setpoint": null, "psa_nongeometry_fraction": null, "ssa_nongeometry_fraction": null, "notes": null, "ventilation_standard": "CBES T24 2001", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Back_Space", "ventilation_per_area": 0.2, "ventilation_per_person": 15.0, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": 3.0, "occupancy_schedule": "RetailOccupancy", "occupancy_activity_schedule": "RetailPeopleActivityLevel", "is_residential": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.22, "infiltration_air_changes": null, "infiltration_schedule": "RetailInfiltration", "infiltration_schedule_perimeter": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 0.2, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailReceptacle", "additional_electric_equipment_schedule": null, "additional_gas_equipment_schedule": null, "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": 51.0, "service_water_heating_area": 18844.0, "service_water_heating_peak_flow_per_area": 0.000950996, "service_water_heating_system_type": "Shared", "booster_water_heater_fraction": null, "service_water_heating_target_temperature": 110.0, "booster_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RetailServiceHotWater", "exhaust_per_area": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_availability_schedule": null, "exhaust_flow_fraction_schedule": null, "balanced_exhaust_fraction_schedule": null }, { "template": "CBES T24 2001", "building_type": "Retail", "space_type": "Entry", "lighting_standard": "CBES T24 2001", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Entry", "lighting_per_area": 2.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_fraction_replaceable": null, "lpd_fraction_linear_fluorescent": 1.0, "lpd_fraction_compact_fluorescent": null, "lpd_fraction_high_bay": null, "lpd_fraction_specialty_lighting": null, "lpd_fraction_exit_lighting": null, "lighting_schedule": "RetailLights", "compact_fluorescent_lighting_schedule": null, "high_bay_lighting_schedule": null, "specialty_lighting_schedule": null, "exit_lighting_schedule": null, "target_illuminance_setpoint": null, "psa_nongeometry_fraction": null, "ssa_nongeometry_fraction": null, "notes": null, "ventilation_standard": "CBES T24 2001", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Entry", "ventilation_per_area": 0.2, "ventilation_per_person": 15.0, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": 33.01, "occupancy_schedule": "RetailOccupancy", "occupancy_activity_schedule": "RetailPeopleActivityLevel", "is_residential": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.22, "infiltration_air_changes": null, "infiltration_schedule": "RetailInfiltration", "infiltration_schedule_perimeter": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailReceptacle", "additional_electric_equipment_schedule": null, "additional_gas_equipment_schedule": null, "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail FRONT ENTRY COOLING_CBES", "service_water_heating_peak_flow_rate": 51.0, "service_water_heating_area": 129.0, "service_water_heating_peak_flow_per_area": 0.000950996, "service_water_heating_system_type": "Shared", "booster_water_heater_fraction": null, "service_water_heating_target_temperature": 110.0, "booster_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RetailServiceHotWater", "exhaust_per_area": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_availability_schedule": null, "exhaust_flow_fraction_schedule": null, "balanced_exhaust_fraction_schedule": null }, { "template": "CBES T24 2001", "building_type": "Retail", "space_type": "Point_of_Sale", "lighting_standard": "CBES T24 2001", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Point_of_Sale", "lighting_per_area": 2.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_fraction_replaceable": null, "lpd_fraction_linear_fluorescent": 1.0, "lpd_fraction_compact_fluorescent": null, "lpd_fraction_high_bay": null, "lpd_fraction_specialty_lighting": null, "lpd_fraction_exit_lighting": null, "lighting_schedule": "RetailLights", "compact_fluorescent_lighting_schedule": null, "high_bay_lighting_schedule": null, "specialty_lighting_schedule": null, "exit_lighting_schedule": null, "target_illuminance_setpoint": null, "psa_nongeometry_fraction": null, "ssa_nongeometry_fraction": null, "notes": null, "ventilation_standard": "CBES T24 2001", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Point_of_Sale", "ventilation_per_area": 0.2, "ventilation_per_person": 15.0, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": 33.01, "occupancy_schedule": "RetailOccupancy", "occupancy_activity_schedule": "RetailPeopleActivityLevel", "is_residential": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.22, "infiltration_air_changes": null, "infiltration_schedule": "RetailInfiltration", "infiltration_schedule_perimeter": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailReceptacle", "additional_electric_equipment_schedule": null, "additional_gas_equipment_schedule": null, "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": 51.0, "service_water_heating_area": 1623.0, "service_water_heating_peak_flow_per_area": 0.000950996, "service_water_heating_system_type": "Shared", "booster_water_heater_fraction": null, "service_water_heating_target_temperature": 110.0, "booster_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RetailServiceHotWater", "exhaust_per_area": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_availability_schedule": null, "exhaust_flow_fraction_schedule": null, "balanced_exhaust_fraction_schedule": null }, { "template": "CBES T24 2001", "building_type": "Retail", "space_type": "Retail", "lighting_standard": "CBES T24 2001", "lighting_primary_space_type": "Retail", "lighting_secondary_space_type": "Retail", "lighting_per_area": 2.0, "lighting_per_person": null, "additional_lighting_per_area": null, "lighting_fraction_to_return_air": 0.0, "lighting_fraction_radiant": 0.0, "lighting_fraction_visible": 0.0, "lighting_fraction_replaceable": null, "lpd_fraction_linear_fluorescent": 1.0, "lpd_fraction_compact_fluorescent": null, "lpd_fraction_high_bay": null, "lpd_fraction_specialty_lighting": null, "lpd_fraction_exit_lighting": null, "lighting_schedule": "RetailLights", "compact_fluorescent_lighting_schedule": null, "high_bay_lighting_schedule": null, "specialty_lighting_schedule": null, "exit_lighting_schedule": null, "target_illuminance_setpoint": null, "psa_nongeometry_fraction": null, "ssa_nongeometry_fraction": null, "notes": null, "ventilation_standard": "CBES T24 2001", "ventilation_primary_space_type": "Retail", "ventilation_secondary_space_type": "Retail", "ventilation_per_area": 0.2, "ventilation_per_person": 15.0, "ventilation_air_changes": null, "minimum_total_air_changes": null, "occupancy_per_area": 33.01, "occupancy_schedule": "RetailOccupancy", "occupancy_activity_schedule": "RetailPeopleActivityLevel", "is_residential": null, "infiltration_per_exterior_area": null, "infiltration_per_exterior_wall_area": 0.22, "infiltration_air_changes": null, "infiltration_schedule": "RetailInfiltration", "infiltration_schedule_perimeter": null, "gas_equipment_per_area": null, "gas_equipment_fraction_latent": null, "gas_equipment_fraction_radiant": null, "gas_equipment_fraction_lost": null, "gas_equipment_schedule": null, "electric_equipment_per_area": 1.0, "electric_equipment_fraction_latent": 0.0, "electric_equipment_fraction_radiant": 0.2, "electric_equipment_fraction_lost": 0.0, "electric_equipment_schedule": "RetailReceptacle", "additional_electric_equipment_schedule": null, "additional_gas_equipment_schedule": null, "heating_setpoint_schedule": "Retail HtgSetp", "cooling_setpoint_schedule": "Retail ClgSetp", "service_water_heating_peak_flow_rate": 51.0, "service_water_heating_area": 18844.0, "service_water_heating_peak_flow_per_area": 0.000950996, "service_water_heating_system_type": "Shared", "booster_water_heater_fraction": null, "service_water_heating_target_temperature": 110.0, "booster_water_heating_target_temperature": null, "service_water_heating_fraction_sensible": 0.2, "service_water_heating_fraction_latent": 0.05, "service_water_heating_schedule": "RetailServiceHotWater", "exhaust_per_area": null, "exhaust_fan_efficiency": null, "exhaust_fan_power": null, "exhaust_fan_pressure_rise": null, "exhaust_fan_maximum_flow_rate": null, "exhaust_availability_schedule": null, "exhaust_flow_fraction_schedule": null, "balanced_exhaust_fraction_schedule": null } ] }