3.0 aedg_office_hvac_fan_coil_doas 298c5638-bd9d-4d6a-9c8a-e0514df4db4a fa0c503a-e8b0-4cc1-975a-d83aecf5603b 20200319T195611Z 4435983D AedgOfficeHvacFanCoilDoas AedgOfficeHvacFanCoilDoas Measure replaces existing HVAC system (if any) with a Fan Coil with DOAS HVAC system (one DOAS per floor). The fan coil with DOAS system (centralized DOAS, with zone level conditioning) is applied to all space types. In select cases, the user is given the option to preserve existing HVAC schedules. In other cases, new schedules are generated that align with AEDG recommendations. The resulting HVAC system reflects the HVAC recommendations of the 50% Small and Medium Office AEDG. Airloops are dedicated to ventilation (DOAS) and have constant speed fan operation and hot and chilled water coils. Conditioning is provided at the zone level with four pipe fan coils with cycling fan operation. Chiller for DOAS and fan coils is air-cooled. ceilingReturnPlenumSpaceType This space type should be part of a ceiling return air plenum. Choice false false costTotalHVACSystem Total Cost for HVAC System ($). Double true false 0 remake_schedules Apply recommended availability and ventilation schedules for air handlers? Boolean true false true true true false false HVAC.Whole System Measure Type ModelMeasure string Uses SketchUp API false boolean AEDG_HVAC_GenericTestModel_0225_a.osm osm test ED45BF2B README.md.erb erb readmeerb 703C9964 README.md md readme DF10EF4E OsLib_AedgMeasures.rb rb resource EDB45706 AedgOfficeHvacFanCoilDoas_Test.rb rb test 76BBCFD4 LICENSE.md md license E0468DD6 OpenStudio 2.0.0 2.0.0 measure.rb rb script 384CCB2E os_lib_constructions.rb rb resource E1FA367A os_lib_helper_methods.rb rb resource 07B01D67 os_lib_lighting_and_equipment.rb rb resource 6CE32103 os_lib_hvac.rb rb resource 0F8A06F5 os_lib_schedules.rb rb resource B38668F5 os_lib_geometry.rb rb resource 674C561A