Sha256: 0dccc8f509cae4647166a6bfd1901f134a47558c85fe580b59068354250ce440

Contents?: true

Size: 1.27 KB

Versions: 12

Compression:

Stored size: 1.27 KB

Contents

class ASHRAE9012019 < ASHRAE901
  # @!group AirTerminalSingleDuctVAVReheat
  # Set the initial minimum damper position based on OA rate of the space and the template.
  # Zones with low OA per area get lower initial guesses.
  # Final position will be adjusted upward as necessary by Standards.AirLoopHVAC.apply_minimum_vav_damper_positions
  #
  # @param air_terminal_single_duct_vav_reheat [OpenStudio::Model::AirTerminalSingleDuctVAVReheat] the air terminal object
  # @param zone_oa_per_area [Double] the zone outdoor air per area in m^3/s*m^2
  # @return [Bool] returns true if successful, false if not
  def air_terminal_single_duct_vav_reheat_apply_initial_prototype_damper_position(air_terminal_single_duct_vav_reheat, zone_oa_per_area)
    min_damper_position = case air_terminal_single_duct_vav_reheat_reheat_type(air_terminal_single_duct_vav_reheat)
                          when 'HotWater'
                            0.2
                          when 'Electricity', 'NaturalGas'
                            0.3
                          else
                            0.2
                          end

    # Set the minimum flow fraction
    air_terminal_single_duct_vav_reheat.setConstantMinimumAirFlowFraction(min_damper_position)

    return true
  end
end

Version data entries

12 entries across 12 versions & 1 rubygems

Version Path
openstudio-standards-0.4.0 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.3.1.rc2 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.3.1.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.3.0 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.2.17.rc2 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.2.17.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.2.16 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.2.16.rc2 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.2.16.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.2.15 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.2.15.pre.rc2 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb
openstudio-standards-0.2.15.pre.rc1 lib/openstudio-standards/prototypes/ashrae_90_1/ashrae_90_1_2019/ashrae_90_1_2019.AirTerminalSingleDuctVAVReheat.rb