  "construction_properties": [
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.45,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.35,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.35,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.35,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.282,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.282,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.282,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.074,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.614,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.074,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.074,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.151,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.113,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.352,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.292,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.16,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.34,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 1",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.35,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.282,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.081,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.34,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.151,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.15,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.113,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.15,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.15,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.15,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.352,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.15,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.15,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.292,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.39 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.35,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.282,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.046,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.081,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.046,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.046,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.41,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.151,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.24,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.113,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.24,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.24,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.24,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.352,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.24,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.24,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.292,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.98 SHGC 0.19 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.90 SHGC 0.34 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.90 SHGC 0.27 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 1.36 SHGC 0.19 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 2B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.282,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.081,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.29,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.123,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.113,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.352,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.72 SHGC 0.25 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.72,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.143,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.143,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.17 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.34,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.30 SHGC 0.27 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.69 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.282,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.048,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.081,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.048,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.048,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.29,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.123,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.16,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.113,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.16,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.16,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.16,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.352,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.16,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.16,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.25 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.25,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.17 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.30 SHGC 0.27 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.69 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.65,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.282,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.088,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.081,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.088,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.088,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.49,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.123,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.113,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.352,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.13,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.72 SHGC 0.39 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.72,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.61 Sgl Green 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.61 Sgl Green 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.61 Sgl Green 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 1.22 SHGC 0.61 Sgl Green 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.61 Sgl Green 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 1.22 SHGC 0.61 Sgl Green 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.143,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.143,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.98 SHGC 0.61 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.98 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.90 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.90 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.36 SHGC 0.61 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 1.36 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 3C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.058,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.081,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.058,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.058,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.086,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.086,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.12,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.104,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.113,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.59 SHGC 0.36 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.59,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.95,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.111,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.111,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 0.98 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.30 SHGC 0.62 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.65,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.58 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.059,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.081,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.059,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.059,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.19,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.104,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.113,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.72 SHGC 0.36 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.72,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.95,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.125,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.125,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 0.98 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.30 SHGC 0.62 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.65,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.58 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.064,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.081,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.064,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.064,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.085,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.085,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.104,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.092,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.113,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.092,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.092,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.092,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.092,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.092,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.72 SHGC 0.39 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.72,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.95,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.111,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.111,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 0.98 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.30 SHGC 0.62 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.65,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.58 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 4C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.053,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.053,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.053,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.053,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.09,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.057,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.59 SHGC 0.39 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.59,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.053,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.076,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.076,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.14,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.09,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.057,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.59 SHGC 0.39 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.59,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.7,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.053,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.076,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.076,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.14,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.09,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.057,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.082,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.59 SHGC 0.39 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.59,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 1.14,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 5C",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.053,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.071,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.09,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.057,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.52 SHGC 0.39 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.52,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.78,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.083,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 0.119,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.083,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 0.98 SHGC 0.45 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.65,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.87 SHGC 0.71 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.87,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.65,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 0.74 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.74,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.34,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6A",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.322,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.069,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.0066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.049,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.053,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.049,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.049,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.049,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.049,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.079,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.09,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.057,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.072,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.52 SHGC 0.39 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.52,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.39 Dbl Ref-D Clr 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.78,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.091,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 0.119,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.091,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 0.98 SHGC 0.45 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.65,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.87 SHGC 0.71 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.87,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.65,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 0.74 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.74,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.34,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.49 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.61,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 6B",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.39,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.137,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.066,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.04,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.053,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.04,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.04,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.04,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.065,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.04,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.061,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.08,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.058,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.057,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.058,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.058,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.058,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.058,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.058,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.52 SHGC 0.49 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.52,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.57,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.84,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.78,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 1.02,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.54,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.077,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 0.119,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.077,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 1.17 SHGC 0.68 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 1.17 SHGC 0.64 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.17,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.98 SHGC 0.36 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.87 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.87,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.61,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.90 SHGC 0.39 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.9,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.69 SHGC 0.68 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.69 SHGC 0.64 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.69,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 7",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 1.36 SHGC 0.36 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.36,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.65,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Nonresidential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Residential",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "NonSwinging",
      "building_category": "Semiheated",
      "construction": "Typical Overhead Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.5,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorDoor",
      "standards_construction_type": "Swinging",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Door",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic ExteriorFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.137,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.038,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.032,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.052,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.033,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorFloor",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.051,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Nonresidential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.031,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Residential",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.027,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Attic and Other",
      "building_category": "Semiheated",
      "construction": "Typical Wood Joist Attic Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.034,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Nonresidential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.031,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Residential",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.031,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "IEAD",
      "building_category": "Semiheated",
      "construction": "Typical IEAD Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.031,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.049,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorRoof",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Roof",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.031,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Adiabatic",
      "construction": "Adiabatic Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.047,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.071,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Exterior Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.151,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Residential",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.057,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "Metal Building",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Metal Building Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "SteelFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Steel Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.124,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Residential",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.045,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWall",
      "standards_construction_type": "WoodFramed",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Wood Framed Exterior Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.089,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Nonresidential",
      "construction": "U 0.52 SHGC 0.615 Simple Glazing Window",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.52,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Residential",
      "construction": "U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.46,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (all other)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Nonresidential",
      "construction": "U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.46,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Residential",
      "construction": "U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.46,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Metal framing (curtainwall/storefront)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Nonresidential",
      "construction": "U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.46,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Residential",
      "construction": "U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.46,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "ExteriorWindow",
      "standards_construction_type": "Nonmetal framing (all)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Nonresidential",
      "construction": "U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Residential",
      "construction": "U 0.46 SHGC 0.45 Dbl Grey 6mm/13mm Air",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.46,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GlassDoor",
      "standards_construction_type": "Metal framing (entrance door)",
      "building_category": "Semiheated",
      "construction": "U 1.22 SHGC 0.25 Sgl Elec Ref Colored 6mm",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 1.22,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.78,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.78,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Heated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.95,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Adiabatic",
      "construction": "Adiabatic GroundContactFloor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": 0.0,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": null,
      "u_value_includes_exterior_film_coefficient": null,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.54,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Residential",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.52,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactFloor",
      "standards_construction_type": "Unheated",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Carpeted 6in Slab Floor",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": 0.73,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Nonresidential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.063,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Residential",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": null,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": 0.119,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "GroundContactWall",
      "standards_construction_type": "Mass",
      "building_category": "Semiheated",
      "construction": "Typical Insulated Basement Mass Wall",
      "orientation": null,
      "minimum_percent_of_surface": null,
      "maximum_percent_of_surface": null,
      "assembly_maximum_u_value": 0.063,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.98 SHGC 0.45 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.62,
      "assembly_minimum_vt_shgc": null,
      "notes": "same as 90.1-2004"
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Residential",
      "construction": "U 0.98 SHGC 0.45 Sgl Ref-B-H Clr 6mm",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.98,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.27,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Glass with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.30 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.3,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.61,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Residential",
      "construction": "U 0.61 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.61,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.49,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Plastic with Curb",
      "building_category": "Semiheated",
      "construction": "U 1.10 SHGC 0.77 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 1.1,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.36,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Nonresidential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": 0.19,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Residential",
      "construction": "U 0.57 SHGC 0.49 Dbl Blue 6mm/6mm Air",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.58,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    },
    {
      "template": "DOE Ref 1980-2004",
      "climate_zone_set": "ClimateZone 8",
      "operation_type": null,
      "intended_surface_type": "Skylight",
      "standards_construction_type": "Without Curb",
      "building_category": "Semiheated",
      "construction": "U 0.81 SHGC 0.65 Simple Glazing Skylight",
      "orientation": null,
      "minimum_percent_of_surface": 0.0,
      "maximum_percent_of_surface": 2.0,
      "assembly_maximum_u_value": 0.81,
      "u_value_includes_interior_film_coefficient": true,
      "u_value_includes_exterior_film_coefficient": true,
      "assembly_maximum_f_factor": null,
      "assembly_maximum_c_factor": null,
      "assembly_maximum_solar_heat_gain_coefficient": null,
      "assembly_minimum_vt_shgc": null,
      "notes": null
    }
  ]
}