# ******************************************************************************* # OpenStudio(R), Copyright (c) 2008-2019, Alliance for Sustainable Energy, LLC. # All rights reserved. # Redistribution and use in source and binary forms, with or without # modification, are permitted provided that the following conditions are met: # # (1) Redistributions of source code must retain the above copyright notice, # this list of conditions and the following disclaimer. # # (2) Redistributions in binary form must reproduce the above copyright notice, # this list of conditions and the following disclaimer in the documentation # and/or other materials provided with the distribution. # # (3) Neither the name of the copyright holder nor the names of any contributors # may be used to endorse or promote products derived from this software without # specific prior written permission from the respective party. # # (4) Other than as required in clauses (1) and (2), distributions in any form # of modifications or other derivative works may not use the "OpenStudio" # trademark, "OS", "os", or any other confusingly similar designation without # specific prior written permission from Alliance for Sustainable Energy, LLC. # # THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) AND ANY CONTRIBUTORS # "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, # THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE # ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S), ANY CONTRIBUTORS, THE # UNITED STATES GOVERNMENT, OR THE UNITED STATES DEPARTMENT OF ENERGY, NOR ANY OF # THEIR EMPLOYEES, BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, # EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT # OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS # INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, # STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY # OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. # ******************************************************************************* module OsLib_QAQC # Check the plant loop operational vs. sizing temperatures # and make sure everything is coordinated. This identifies problems # caused by sizing to one set of conditions and operating at a different set. def check_plant_temps(category, target_standard, max_sizing_temp_delta = 0.1, name_only = false) # summary of the check check_elems = OpenStudio::AttributeVector.new check_elems << OpenStudio::Attribute.new('name', 'Plant Loop Temperatures') check_elems << OpenStudio::Attribute.new('category', category) check_elems << OpenStudio::Attribute.new('description', 'Check that plant loop sizing and operation temperatures are coordinated.') # stop here if only name is requested this is used to populate display name for arguments if name_only == true results = [] check_elems.each do |elem| results << elem.valueAsString end return results end std = Standard.build(target_standard) begin # Check each plant loop in the model @model.getPlantLoops.sort.each do |plant_loop| loop_name = plant_loop.name.to_s # Get the central heating and cooling SAT for sizing sizing_plant = plant_loop.sizingPlant loop_siz_f = OpenStudio.convert(sizing_plant.designLoopExitTemperature, 'C', 'F').get # Determine the min and max operational temperatures loop_op_min_f = nil loop_op_max_f = nil plant_loop.supplyOutletNode.setpointManagers.each do |spm| obj_type = spm.iddObjectType.valueName.to_s case obj_type when 'OS_SetpointManager_Scheduled' sch = spm.to_SetpointManagerScheduled.get.schedule if sch.to_ScheduleRuleset.is_initialized min_c = std.schedule_ruleset_annual_min_max_value(sch.to_ScheduleRuleset.get)['min'] max_c = std.schedule_ruleset_annual_min_max_value(sch.to_ScheduleRuleset.get)['max'] elsif sch.to_ScheduleConstant.is_initialized min_c = std.schedule_constant_annual_min_max_value(sch.to_ScheduleConstant.get)['min'] max_c = std.schedule_constant_annual_min_max_value(sch.to_ScheduleConstant.get)['max'] else next end loop_op_min_f = OpenStudio.convert(min_c, 'C', 'F').get loop_op_max_f = OpenStudio.convert(max_c, 'C', 'F').get when 'OS_SetpointManager_Scheduled_DualSetpoint' spm = spm.to_SetpointManagerSingleZoneReheat.get # Lowest setpoint is minimum of low schedule low_sch = spm.to_SetpointManagerScheduled.get.lowSetpointSchedule next if low_sch.empty? low_sch = low_sch.get if low_sch.to_ScheduleRuleset.is_initialized min_c = std.schedule_ruleset_annual_min_max_value(low_sch.to_ScheduleRuleset.get)['min'] max_c = std.schedule_ruleset_annual_min_max_value(low_sch.to_ScheduleRuleset.get)['max'] elsif low_sch.to_ScheduleConstant.is_initialized min_c = std.schedule_constant_annual_min_max_value(low_sch.to_ScheduleConstant.get)['min'] max_c = std.schedule_constant_annual_min_max_value(low_sch.to_ScheduleConstant.get)['max'] else next end loop_op_min_f = OpenStudio.convert(min_c, 'C', 'F').get # Highest setpoint it maximum of high schedule high_sch = spm.to_SetpointManagerScheduled.get.highSetpointSchedule next if high_sch.empty? high_sch = high_sch.get if high_sch.to_ScheduleRuleset.is_initialized min_c = std.schedule_ruleset_annual_min_max_value(high_sch.to_ScheduleRuleset.get)['min'] max_c = std.schedule_ruleset_annual_min_max_value(high_sch.to_ScheduleRuleset.get)['max'] elsif high_sch.to_ScheduleConstant.is_initialized min_c = std.schedule_constant_annual_min_max_value(high_sch.to_ScheduleConstant.get)['min'] max_c = std.schedule_constant_annual_min_max_value(high_sch.to_ScheduleConstant.get)['max'] else next end loop_op_max_f = OpenStudio.convert(max_c, 'C', 'F').get when 'OS_SetpointManager_OutdoorAirReset' spm = spm.to_SetpointManagerOutdoorAirReset.get temp_1_f = OpenStudio.convert(spm.setpointatOutdoorHighTemperature, 'C', 'F').get temp_2_f = OpenStudio.convert(spm.setpointatOutdoorLowTemperature, 'C', 'F').get loop_op_min_f = [temp_1_f, temp_2_f].min loop_op_max_f = [temp_1_f, temp_2_f].max else next # Only check the commonly used setpoint managers end end # Compare plant loop sizing temperatures to operational temperatures case sizing_plant.loopType when 'Heating' if loop_op_max_f if ((loop_op_max_f - loop_siz_f) / loop_op_max_f).abs > max_sizing_temp_delta check_elems << OpenStudio::Attribute.new('flag', "For #{plant_loop.name}, the sizing is done with a supply water temp of #{loop_siz_f.round(2)}F, but the setpoint manager controlling the loop operates up to #{loop_op_max_f.round(2)}F. These are farther apart than the acceptable #{(max_sizing_temp_delta * 100.0).round(2)}% difference.") end end when 'Cooling' if loop_op_min_f if ((loop_op_min_f - loop_siz_f) / loop_op_min_f).abs > max_sizing_temp_delta check_elems << OpenStudio::Attribute.new('flag', "For #{plant_loop.name}, the sizing is done with a supply water temp of #{loop_siz_f.round(2)}F, but the setpoint manager controlling the loop operates down to #{loop_op_min_f.round(2)}F. These are farther apart than the acceptable #{(max_sizing_temp_delta * 100.0).round(2)}% difference.") end end when 'Condenser' # Not checking sizing of condenser loops end end rescue StandardError => e # brief description of ruby error check_elems << OpenStudio::Attribute.new('flag', "Error prevented QAQC check from running (#{e}).") # backtrace of ruby error for diagnostic use if @error_backtrace then check_elems << OpenStudio::Attribute.new('flag', e.backtrace.join("\n").to_s) end end # add check_elms to new attribute check_elem = OpenStudio::Attribute.new('check', check_elems) return check_elem # note: registerWarning and registerValue will be added for checks downstream using os_lib_reporting_qaqc.rb end end